雨水管道设计说明书

雨水管道设计说明书
雨水管道设计说明书

雨水管渠系统设计

一、设计资料与要求

试进行某研究所西南区雨水管道(包括生产废水在内)的设计和计算。并绘制该区的雨水管道平面图。已知条件:

(1) 如图2-1所示该区总平面图;

(2) 当地暴雨强度公式为)10/()

lg 81.01(7002

45

.0m s L t

P q ??+=

(3) 采用设计重现期P=1a,地面集水时间min 101=t (4) 厂区道路主干道宽6m,支干道宽3.5m,均为沥青路面; (5) 各试验室生产废水量见表2-1,排水管出口位置见图2-1;

(6) 生产废水允许直接排入雨水道,各车间生产废水管出口埋深均为1.50m(指室内地

面至管内底的高度);

(7) 厂区各车间及试验室均无室内雨水道;

(8) 厂区地质条件良好,冰冻深度较小,可不予考虑;

(9)出去的雨水口接入城市雨水道,接管点位置在厂南面,坐标为x=722.50,y=520.00,

城市雨水道为砖砌拱形方沟,沟宽1.2m,沟高(至拱内顶)1.8m,改点处的沟内底标高为37.70,地面标高为41.10m.

表2-1 各车间生产废水量表

(1)设计说明书一份;

(2)管道平面布置图一张(A3);

(3)管道水力计算图一张(A3);

(4)管段水力计算表一份。

二、划分排水流域及管道定线

根据厂区的总平面布置图,可知该厂地形平坦,雨水和生产废水就近排入各雨水口。厂区内建筑较多,相应的交通量会比较大,故雨水管道采取暗管。雨水出口接入城市雨水道,城市雨水道为砖砌拱形方。

根据总平面图给出的标高绘制等高线,可知厂区西北高,东南低,局部有高地。再根据等高线合理布置雨水口,适当划分排水区域。根据地形、雨水口分布定管线,使绝大部分雨水以最短的距离排入街道低侧的雨水管道。拟将该厂区划分为16个流域。如图2-2所示。

图2-2

三、划分设计管段

根据管道的具体位置,在管道转弯处、管径或坡度改变出,有支管接入出或两条以上管道交汇处以及超过一定距离的直线管端上都应该设置检查井。把两个检查井之间流量没有变化且预计管径和坡度也没有变化的管段定位设计管段。并从管段从下游往下游按循序进行检查井的编号。

四、划分并计算各设计管段的汇水面积

各设计管段汇水面积的划分应结合地形坡度、汇水面积的大小以及雨水管道布置等情况而划定。地形较平坦时,可按就近排入附近雨水管道的原则划分汇水面积;地形坡度较大时,应按地面雨水径流的水流方向划分汇水面积。并将每块面积进行编号,计算其面积的数值。经简化,厂区的流水区域如图2-3所示,图中每一区域已包含街道及绿地在内,不仅仅是建筑面积。表2-1为地面标高表。表2-2为管道长度表。表2-3为汇水面积计算表。

图2-3

表2-1 图2-3中地面标高表

表2-3 汇水面积计算表

五、确定平均径流系数

沥青路面,径流系数90.0=l

ψ

路面面积2

3200m f l =;建筑物径流系数90.0=j

ψ;

建筑物面积2

7780m f j =;绿地径流系数15.0=ld

ψ;绿地面积2

25120m f ld =。

38.036100

25120

15.0778090.0320090.0=?+?+?=

=

F

f i

i P

ψψ

六、水力计算

本设计中地形坡度较大,地面集水时间采用t 1=10min.设计重现期选用P=1a.管道起点埋深根据支管的接入标高等条件,采用2.0m.

列表进行干管的水力计算。

表2-4 水力计算表

水力计算说明:

1. 从表2-4中第1项为需要机算的设计管段,从上游至下游依次写出。第2、3、13、

14项从表2-1、2-2、2-3中去的。其余各项经计算得到。

2. 当有支管与干管相接的检查井处,必然会有两个甚至多个∑2t 值和两个甚至多个

的管底标高值。再继续计算相交后的下一个管段时,应采用大的那一个∑2t 值和小的那个管底标高值。如管段1~2,是干管的其实管段,但是由于有支管的接入,支管之前有汇入区域1的的雨水以及y406出口的废水,所以∑2t =1min.而对于11~1段∑2t =0,将此值列于表2-4中第4项。

3. 根据确定的设计参数,求单位面积径流量q 0

设计径流量公式:5

.025

.02)

210(266)210(38.0700t F t F qF Q ∑+=

∑+?=

单位面积径流量公式:5

.020)

210(266t q ∑+=

4. q 0为管内雨水流行时间∑2t 的函数,只要知道各设计管段内雨水流行时间∑2t ,

即可求出该设计管段的单位面积径流量q 0。如管段1~2的∑2t =1min,代入

79.76)

1*210(2665

.00=+=

q (L(s*ha)),将q 0列入表中第6项。

5.用各设计管段的单位面积径流量乘以该管段的总汇水面积得到雨水设计流量Q1,

再加上集中流量Q2,可得到总设计流量Q。如管段1~2的雨水设计流量Q1=76.79*0.3736=28.65L/s. Q=Q1+Q2=28.69+15=43.65 L/s. 可将Q1,Q2,Q分别列入表中的第7.8.9项

6.在求得设计流量后,即可进行水力计算,求管径,管道坡度和流速。在查水力计算

图或表时,Q,v,I,D,4个水力因素可以相互适当调整,式计算结果既要符合水力计算设计数据的规定,又经济合理。将确定的管径,坡度,流速各值列入表中第10,11,12项。第13项管道输水能力Q’是指在水力计算中管段在确定的管径,坡度,流速的条件下,实际通过的流量。该值等于或略大于设计流量Q。

7.根据设计管段的设计流速求本关断的馆内雨水流行时间t2.例如管段1~2的管内雨

水流行时间t2=L1~2/v1~2=40/(0.75*60)=0.89min.将该值列入表中的第5项。

8.根据冰冻情况,雨水管道衔接要求及承受荷载的要求,确定管道起点的埋深或管底

标高。本设计中,厂区雨水出口接入城市雨水道,接管点处的沟内底标高为

37.70m,地面标高为41.10m,则得:沟底深41.10-37.70=3.40m; 覆土高

3.40-1.80=1.60m. 起点埋深设定为2.0m,即管段1~2的起点埋深为2.0m,由水力计

算的9—城市雨水接管点的末端埋深为1.683,符合条件,可接入城市雨水道。

雨水管道各设计管段在搞成上采用管顶平接。

9.在划分各设计管段的汇水面积时,应尽可能使各设计管段的汇水面积均匀增加,否

则会出现下游管段的设计流量小于上一管段设计流量的情况。如管段9~城市雨水接管点的设计流量小于8~9的设计流量,这是因为下游管段的集水时间大于上游管段的集水时间,故下游管段的设计暴雨强度小于上一管段的暴雨强度,而总的汇水面积又没有增加,出现这种情况,应取上一管段的设计流量作为下一管段的设计流量。

排水管网设计说明书

排水管网设计说明 书

环境工程设计 大作业 题目城市污水管网的设计姓名姜晨旭 学号 指导教师王庆宏 成绩 二○一七年六月

目录 (一)设计概要 (2) 1.1设计题目 (2) 1.2设计内容 (2) 1.3设计资料 (3) 1.4设计参考资料 (3) (二)排水系统 (3) 2.1排水体制 (3) 2.2排水体制的选择 (4) (三)管网设计 (5) 3.1管道定线 (5) 3.1.1排水管网布置原则 (5) (4)规划时要考虑到使渠道的施工、运行和维护方便; (5) 3.1.2排水管网定线考虑因素 (5) 3.1.3污水主干管定线 (6) 3.1.4污水干管定线 (6) 3.2水量计算 (7) 3.3水力学计算 (9) 3.3.1水力学计算要求 (9) 3.3.2水力学计算过程 (11) (四)图形绘制 (13) (五)管材设计 (14)

(一)设计概要 1.1设计题目 1.2设计内容 (1)绘制CAD图并计算小区面积、布设管道、测量出地面标高;(2)完成流量计算并列出污水干管设计流量计算表; (3)完成水力计算,经过查阅水力计算图,完成污水干管水力计算表; (4)绘制主干管的纵剖图并进行标注。

1.3设计资料 (1)人口密度为400cap/ha; (2)生活污水定额140L/cap·d; (3)工厂的生活污水和淋浴污水设计流量分别是8.24L/s和6.84L/s,生产污水设计流量为26.4L/s, 工厂排水口地面标高为43.5m,管底埋深不小于2m,土壤冰冻深度为0.8m; (4)沿河岸堤坝顶标高40m。 1.4设计参考资料 1.《排水工程》(上册)(第四版),中国建筑工业出版社,1999 2.《环境工程设计》赵立军陈进富主编,中国石化出版社(二)排水系统 2.1排水体制 废水分为生活污水、工业废水和雨水三种类型,它们能 够采用一个排水管网系统来排除,也能够采用各自独立的分 质排水管网系统来排除。排水体制主要有合流制和分流制两 种。其中合流制又分为直排式合流制与截流式合流制两种。 前者是将排除的混合污水不经处理直接就进排入水体;后者 则是在合流干管与截流干管交接处设置溢流井,超出处理能

(完整版)室外管网设计说明

1. 设计说明: 1.1 设计依据: 1.1.1 《室外给水设计规范》GB 50013-2006; 1.1.2 《室外排水设计规范》GB 50014-2006(2014年版); 1.1.3 《建筑给水排水设计规范》GB50015-2003(2009年版); 1.1.4 《建筑设计防火规范》GB50016-2006; 1.1.5《建筑给水排水及采暖工程施工质量验收规范》GB50242-2002; 1.1.6 《自动喷水灭火系统设计规范》GB 50084-2001(2005年版)。 1.1.7 甲方提供的院区周围市政道路的给水排水管网现状图、设计委托书; 1.1.8 建筑专业提供的作业图及相关专业提供的设计资料。 1.2 工程概况: 本工程为卓达绿色建筑(新材料)海城产业园,工程位于辽宁省海城太湖路两侧西。建设单位 为卓达辽宁 1.3 设计范围: 1.3.1 卓达绿色建筑(新材料)海城产业园范围内生活给水管网、工艺给水管网(其中工艺给 水管网管径和用水量由甲方提供,本次设计只负责工艺用水管线位置的布置)消防管网、雨水管网、污水管网的设计,不包含生产和工艺排水管网、防洪设计。 1.4 管道系统: 本工程设有给水管网、雨水管网、污水管网。 1.4.1 给水系统: 1.4.1.1 生活和消防用水水源来自市政管网,由北侧太湖路接入一条dn180给水管接入厂区内作为生活和消防用水;管道覆土 1.35m。根据甲方提供的资料,市政管网水量、水质满足 使用要求,太湖路市政绝对水压0.20MPa,只能满足厂房和动力中心补水要求,不能满足厂 前区使用要求,厂前区供水需要在动力中心加压后供给厂前区单体,供水压力为0.35MPa;生产用水水源为市政管网直接供水;绿化用水水源为厂区内的自挖井(水量和水质由甲方负 责满足现行绿化用水水质要求);总入口处的计量装置由市政部门负责。 1.4.3 污水设计: 厂区内污水收集后,经化粪池处理之后分别接入西侧经七路和北侧东湖路的市政污水管网中。 1.4.4 雨水设计: 雨水暴雨强度公式采用辽宁鞍山暴雨强度公式i= ,设计重现期为2年;区域内雨水收集后,排入北侧太湖路雨水管网中。 2 施工说明: 2.1 市政接管经标高确认: 2.1.1 建筑室外雨水管道,在施工前应对本工程允许接入西侧河道水面标高进行实测确认与 设计标高无误 差后,再进行施工。 2.1.2 如河道水面、市政污水管道管底实测标高与设计标高有误差时,应通知设计院,设计 院按实测标高对设计标高进行调整修改,以修改后的管道标高进行施工。 2.2 管材及接口: 2.2.1 埋地给水管采用PE100管(公称压力 1.25MPa),采用热熔连接,过路部分增加钢套管, 延出道路两侧各0.5m。 2.2.2 埋地消防给水管采用PE100管(公称压力 1.60MPa),热熔连接;连接室外消火栓支管,

排水管网设计说明书

环境工程设计 大作业 题目城市污水管网的设计姓名姜晨旭 学号2014010650 指导教师王庆宏 成绩 二○一七年六月

目录 (一)设计概要 (2) 1.1设计题目 (2) 1.2设计内容 (2) 1.3设计资料 (2) 1.4设计参考资料 (3) (二)排水系统 (3) 2.1排水体制 (3) 2.2排水体制的选择 (4) (三)管网设计 (4) 3.1管道定线 (4) 3.1.1排水管网布置原则 (4) (4)规划时要考虑到使渠道的施工、运行和维护方便; (4) 3.1.2排水管网定线考虑因素 (4) 3.1.3污水主干管定线 (5) 3.1.4污水干管定线 (5) 3.2水量计算 (6) 3.3水力学计算 (8) 3.3.1水力学计算要求 (8) 3.3.2水力学计算过程 (9) (四)图形绘制 (10) (五)管材设计 (11)

(一)设计概要 1.1设计题目 1.2设计内容 (1)绘制CAD图并计算小区面积、布设管道、测量出地面标高; (2)完成流量计算并列出污水干管设计流量计算表; (3)完成水力计算,通过查阅水力计算图,完成污水干管水力计算表; (4)绘制主干管的纵剖图并进行标注。 1.3设计资料 (1)人口密度为400cap/ha; (2)生活污水定额140L/cap·d; (3)工厂的生活污水和淋浴污水设计流量分别是8.24L/s和6.84L/s,生产污水设计流量为26.4L/s, 工厂排水口地面标高为43.5m,管底埋深不小于2m,土壤冰冻深度为0.8m; (4)沿河岸堤坝顶标高40m。

1.4设计参考资料 1.《排水工程》(上册)(第四版),中国建筑工业出版社,1999 2.《环境工程设计》赵立军陈进富主编,中国石化出版社 (二)排水系统 2.1排水体制 废水分为生活污水、工业废水和雨水三种类型,它们可以采用一个排水管网系统来排除,也可以采用各自独立的分质排水管网系统来排除。排水体制主要有合流制和分流制两种。其中合流制又分为直排式合流制与截流式合流制两种。前者是将排除的混合污水不经处理直接就进排入水体;后者则是在合流干管与截流干管交接处设置溢流井,超出处理能力的混合污水通过溢流井后直接排入水体,在截流主干管(渠)的末端修建污水处理厂。而分流制又分为完全分流制与不完全分流制两种。前者包括独立的污水排水系统和雨水排水系统;后者只有污水排水系统,未建立雨水排水系统。 合流制与分流制的优缺点如下表所示:

给水管网课程设计说明书

市政与环境工程系 MUNICIPAL AND ENVIRONMENTAL ENGINEERING DEPARTMENT 课程设计 说明书 姓名:陈启帆 学号:23 专业:环境工程 吉林建筑大学城建学院 2016年07月 - 1 -

市政与环境工程系 MUNICIPAL AND ENVIRONMENTAL ENGINEERING DEPARTMENT 课程设计说明书 (吉林省长春地区宽城区给水管网设计) 学生姓名:陈启帆 导师: 学科、专业:环境工程 所在系别:市政与环境工程系 日期:2016年07月 学校名称:吉林建筑大学城建学院 - 2 -

市政与环境工程系 MUNICIPAL AND ENVIRONMENTAL ENGINEERING DEPARTMENT 目录 1. 课程设计题目 (4) 2. 课程设计目的及要求 (4) 3. 设计任务 (5) 4. 原始资料 (5) 5. 基本要求 (8) 6. 设计成果 (8) 7. 设计步骤 (8) 8. 设计用水量计算 (9) 9. 确定给水管网定线方案 (11) 10. 设计流量分配与管径设计 (11) 11. 设计结束语与心得体会 (14) 12. 参考资料 (16) - 3 -

市政与环境工程系 MUNICIPAL AND ENVIRONMENTAL ENGINEERING DEPARTMENT 1. 课程设计题目 吉林省长春地区宽城区给水管网设计 2. 课程设计目的及要求 通过城镇给水管网设计管网的设计步骤和方法,为以后毕业设计及从事给水管网的工程设计打下初步基础。 (1)了解管网定线原则; (2)掌握经济管径选择要求; (3)掌握给水系统压力关系确定方法; (4)掌握管网水力计算。 - 4 -

污水排水管网设计

郑州大学水利与环境学院 《排水工程Ι》课程设计说明书题目:A城新区污水管网工程扩大初步设计 学生姓名 指导教师李桂荣 学号 专业环境工程2班 完成时间2012.3.3

目录 第一节设计说明书 (01) 第二节污水设计计算说明书 (04) 附录 附件一污水管道平面布置图 附件二污水管道各管段污水设计流量计算表 附件三城市污水主干管水力计算表 附件四污水主干管纵剖面图

第一节设计说明书 一、工程任务及设计范围 运用已学的排水管网的专业知识,进行A城新区污水管网工程的扩大初步设计。 设计主要内容如下: (1)设计基础数据的收集。 (2)确定设计方案,划分排水流域,进行污水管道的定线和平面布置。 (3)污水管网总设计流量及各管段设计流量计算。 (4)进行污水管道水力计算,确定管道断面尺寸、设计坡度、埋设深度等。 (5)污水确定污水管道在街道横断面上的位置。 (6)绘制污水管网平面图和纵剖面图。 二、设计原始资料 1. A城市平面规划图(1:1000) 该新城区的规划如图一所示。西部濒临白河,流向自北向南,主要的工业企业集中在城区的东南部,等高线较为平缓,自城区自东向西逐步降低,城区内无明显的起伏地势。 2.服务人口密度:350人/ha;生活污水量标准平均日120L/(cap·d) 3.主要的排污单位有如下工业企业和公共建筑,其位置如平面图所示: ①甲厂:最大班排水量20L/S。 ②乙厂:最大班排水量15 L/S。 ③公共建筑排水量(火车站):15 L/S。 (学校): 10 L/S。 上述工业企业所产生的废水经局部处理后,水质达到《污水综合排放标准》GB8978-1996所规定的三级排放标准后,排入城市污水管网,由污水管道统一收集后排入城市污水处理厂进行集中处理,达标排放。 各企业排水口的管底埋设深度不小于2.0米。设计街区的污水管道最小埋深不小于1.5米。火车站污水管道起端管道埋深为不小于1.5米。 4.自然状况:

污水管网的设计说明及设计计算

污水管网的设计说明及设计计算 1.设计城市概况 假设城市设计为某中小城市的排水管网设计,有明显的排水界限,分为区与区,坡度变化较大。河流为其城市的地面标高的最低点,由河流开始向南、向北地面标高均有不同程度的增加,且城市人口主要集中区,城区基本出去扩建状态中,发展空间巨大,需要结合城市的近远期规划进行管网布置。城市的布局还算合理,区域划分明显,交通发达,对于布管具有相当的简便性。 2.污水管道布管 (2).管道系统的布置形式 对比各种排水管道系统的布置形势,本设计的污水管铺设采用截留式,在地势向水体适当倾斜的地区,各排水区域的干管可以最短距离沿与水体垂直相较的方向布置,沿河堤低边在再敷设主干管,将各个干管的污水截留送至污水厂,截流式的管道布置系统简单经济,有利于污水和雨水的迅速排放,同时对减轻水体污染,改善和保护环境有重大作用,适用于分流制的排水系统,将生活污水、工业废水及初降废水经处理后排入水体。截流式管道系统布置示意图如下. (2).污水管道布管原则 a.按照城市总体规划,结合当地实际情况布置排水管道,并对多种方案进行技术经济比较; b.首先确定排水区界、排水流域和排水体制,然后布置排水管道,应按主干管、干管、支管 c.的顺序进行布置; 1—城镇边界 2—排水流域分界线 3—干管 4—主干管 5—污水厂 6—泵站 7—出水口

d.充分利用地形,尽量采用重力流排除污水,并力求使管线最短和埋深最小; e.协调好与其他地下管线和道路工程的关系,考虑好与企业部管网的衔接; f.规划时要考虑使管渠的施工、运行和维护方便; g.规划布置时应该近远期结合,考虑分期建设的可能性,并留有充分的发展余地。 (3).污水管道布管容 ①.确定排水区界、划分排水流域 本设计中有很明显的排水区界,一条河流自东向西流动,将整个城镇划分为区与区;同时降排水区域分为四个部分,分别有四条干管收集污水,同一进入位于河堤的主干管,送至污水处理厂。 ②.污水厂和出水口位置的选择 本设计中河流流向为自东向西,同时该城镇的夏季主导风向为南风,所以污水处理厂应该设置在城市的西北处河流下游,由于该城镇是中小型城市,所以一个污水处理厂足以实现污水的净化。 ③.污水管道的布置与定线 污水管道的平面布置,一般按照主干管、干管、支管的顺序进行。在总体规划中,只决定污水主干管、干管的走向和平面布置。 定线时,应该充分利用地形,使污水走向按照地面标高由高到低来进行,主干管敷设在地面标高较低的河堤处,管道敷设不宜设在交通繁忙的快车道和狭窄的道路下,一般设在两侧的人行道、绿化带或慢车带下。 支管的平面布置形式采用穿坊式,组成的一个污水排放系统可将该系统穿过其他街区并与所穿过的街区的污水管道相连接。管道的材料采用混凝土管。 ④.确定污水管道系统的控制点和泵站的设置地点 管道系统的控制点为两个工厂和每条管道的起点,这些点决定着管道的最小埋深,由于整个管道的敷设过程中,埋深一直满足最实用条件,且对于将来的发展留有空间,所以不需要提升泵站,全部依靠重力流排水。 ⑤.确定污水管道在街道下的具体位置 充分协调好与其他管段的关系,污水和雨水管道应该敷设在给水管道的下面,处理管道的原则为:未建让已建的,临时性管让永久性管,小管让大管,有压管让无压管,可弯管让不可弯管。 根据以上分析,对整个区域进行布管,干管尽量与等高线垂直,主干管沿河堤进行布置,基本上与等高线平行,整个城镇的管道系统呈现截流式布置,布管方式见附图。(污水管道系统的总体平面布置图)。 3. 管段设计计算:

城市给水管网设计说明

目录 (1) 第一章设计说明 (2) 1.1前言 (2) 1.2设计概况 (2) 第二章给水管网设计计算 (4) 2.1用水量计算 (4) 2.2清水池容积计算 (6) 2.3沿线流量和节点流量计算 (8) 第三章管网平差 (10) 3.1管网平差计算 (10) 3.2水泵扬程及泵机组选定 (10) 3.3等水压线图 (11) 3.4管网造价概算 (11) 附表一 (12) 附表二 (12) 附表三 (13) 附表四 (13) 附表五 (14) 附表六 (14) 附图一 (15)

一、设计说明 1.前言 设计项目性质:本给水管网设计为M市给水管网初步设计,设计水平年为2012年。主要服务对象为该县城镇人口生活用水和工业生产用水及职工生活用水,兼负消防功能,不考虑农业用水。该县城最高日用水量为29000m3,最高日最高时用水量为1982m3,流量550.46L/s,最大用水加消防流量为620.46L/s。 2.设计概况 (1)城市概况:该二区城市人口数为8.6万人,人口密度:239人/公顷,供水普及率100%。城区内建筑物按六层考虑。土壤冰冻深度在地面下1.2m。城市用水由水厂提供。综合生用水定额为160L/cap·d,主导风向是西北风。 表1.工业企业生产、生活用水资料: 企业名生产用水职工生活用水 日用水量 m3/d 逐时变 化 班制 冷车间 人数 热车间 人数 每班淋浴 人数 污染 程度 企业甲3200 均匀三班(8点起始) 1000 800 1600 一般 企业乙3200 均匀二班(8点起始) 800 700 1500 一般 表2.城市用水量变化曲线及时变化系数 时间占最高日用水量(%)时间占最高日用水量(%)时间占最高日用水量(%) 0~1 1.04 8~9 6.21 16~17 4.52 1~2 0.95 9~10 6.12 17~18 4.93 2~3 1.2 10~11 5.58 18~19 5.14 3~4 1.65 11~12 5.48 19~20 5.66 4~5 3.41 12~13 4.97 20~21 5.8 5~6 6.84 13~14 4.81 21~22 4.91 6~7 6.84 14~15 4.11 22~23 3.05 7~8 6.84 15~16 4.18 23~24 1.65 (3)给水系统选择

给排水管网课程设计

《给水排水管网系统》课程设计 计算说明书 题目:衡阳市给水排水管网工程 学院:市政与环境工程学院 专业:给排水科学与工程 姓名:孔庆培 学号:026413158 指导老师:谭水成 完成时间:2015年12月30日

前言 衡阳市给水排水管道工程设计,其市总人口54.32万左右,有一工厂A和火车站。总设计时间为2周,设计内容主要是给水管道的定线、水力计算及部分区域的污水、雨水设计,并作出平面图和纵剖面图。 设计过程中,先大致了解衡阳市地形分布后,决定通过分区供水满足整个城市的用水需求。定线,给水水力计算,确定管径,校核等等,把定下的管径标图并整理报告。考虑城市初步规划,以及资金投资问题,采用完全分流制排水系统。生活污水和工业废水通过污水排水系统送至污水处理厂,经处理后再排入水体。雨水是通过雨水排水系统直接排入水体。 课程设计让我们结合所学知识,运用CAD制图,画出衡阳市给水排水管道总平面分布图,部分污水干管剖面图,学会灵活运用知识。

Preface The design of water supply and drainage pipeline engineering of Hengyang city , the total population of the city is 543,200 around,there are a facto ry “A” and a train station in the city. The total time of the design for 2 weeks, the content of the design is mainly about the water supply pipeline alignment, hydraulic calculation and the sewage of part of area, rainwater design, and make the plane figure and profile. In the design process, first understand topographic distribution of Hengyang city roughly, decide to meet the whole city water demand by the district water supply. Fixed line, calculation, to determine the water hydraulic diameter, checking and so on, to set the diameter of plotting and finishing the report. Considering the preliminary planning of the city, and the problem of capital investment, using completely separate drainage system. Domestic sewage and industrial wastewater is sent to the sewage treatment plant through the sewage system, and then discharged into the water body after the theatment. The rain water is directly discharged into the water body through rainwater drainage system. Curriculum design allows us to combine the knowledge which we have learned, the use of CAD drawing, drawing a distribution map of general layout of water supply and drainage pipeline in Hengyang City, part of the sewage trunk pipe profile, learn to use knowledge flexibly.

排水雨水管网设计计算说明书

仲恺农业工程学院实践教学 给水排水管网工程综合设计 ——排水管网计算书 (2013—2014 学年第二学期) 班级给排1x1 姓名xxx 学号 设计时间~ 指导老师xxxxxxxxxxxxxxx 成绩 城市建设学院

目录

1 设计原始资料 城镇概况 A 城市位于我国华南地区,该城市是广东省辖县级市,自然资源丰富,交通便利。市区地势平坦,主要建在平原上,城市中间以铁路为界,分为两个生活区:Ⅰ区和Ⅱ区。均有给水排水设备,自来水普及率100%。 气候情况 ① 市内多年来的极端高温℃,每年6~8月份的气温最高。而到了冬季(12~2月)温度较低,多年来的极端低温为0℃。 ② 年平均相对湿度为65%,春季湿度大,约为65~90%; ③ 雨季集中在4~9月份,这段时间的降雨量占全年降雨量的80%以上,4~9月份为受热带气旋影响的主要时段,降雨量大,多出现暴雨,年平均降雨量为1930mm ,多集中在6-9月,占全年降雨量的70%。 排水情况 城市用水按19万人口设计,居民最高日用水量按210 (d cap L )。生活污水排水量按给水的90%计算。街坊污水排入区域排水管网,区域排水管网再将接入城市的排水管道系统,最后到污水处理厂进行处理。 2 排水管段设计流量计算 污水管道的布置 地形坡度 地势由西南方向东北方逐渐降低,但总体变化趋势不大。 河流流向 该城市沿市区南部有一条由北至南流向的河流,综合地势原因,污水厂设在地势较低处。

污水管道布置图 居民生活污水计算 查居民生活用水定额表,取居民平均日生活用水定额为210d L?,则居民生活污水量 cap 定额为d % 210 ?189 90 = cap L? 街坊面积总面积计算 根据城市人口为14万,根据草图对街坊区进行编号,得到各街坊面积和总面积,计算见下页表 街区编号 1 2 3 4 5 6 7 8 9 CAD面积 街区面积(ha) 街区编号15 16 17 18 19 20 21 22 23 CAD面积 街区面积(ha) 街区编号29 30 31 32 33 34 35 36 37 CAD面积 街区面积(ha) 街区编号43 44 45 46 47 48 49 50 51 CAD面积 街区面积(ha) 街区编号57 58 59 60 61 62 63 64 65 CAD面积 街区面积(ha) 街区编号71 72 73 74 75 76 77 78 79 CAD面积 街区面积(ha) 街区编号85 86 87 88 89 90 91 92 93 CAD面积 街区面积(ha) 街区编号99 100 101 102 103 104 105 106 107 CAD面积 街区面积(ha) 街区编号112 113 114 115 116 117 118 174 119 CAD面积 街区面积(ha) 街区编号125 126 127 128 129 130 131 132 133 CAD面积 街区面积(ha) 街区编号139 140 141 142 143 144 145 146 147

污水管网设计说明

设计总说明 第一章总论 1.1、前言 农村生活污水处理既是改善民生的重要内容,也是江油市新农村建设最急需、最迫切、最突出的问题之一,具有重要的现实意义。江油市高度重视农村环境整治,大力推进农村生活污水处理工作,以省委十三届四次全会作出的“五水共治”决策为契机,逐步解决农村的水环境污染问题,更好地优化农村水环境,推进转型升级,改善农民生活品质。通过领导重视、政策扶持、机制创新、督查推进等措施,加大工作力度,激发工作热情,深入开展村庄污水整治,不断夯实农村污水治理基础建设。根据省委、省政府关于治水攻坚的决策部署和《关于深化“千村示范万村整治”工程扎实推进农村生活污水治理的意见》(省委办发[2014]2号)文件精神,致力于建设资源节约和环境友好型社会,贯彻可持续发展战略,把农村生活污水处理与保护饮用水源、“五水共治”改善水环境相结合,统筹城乡资源,一体化改善全市水环境,建设农村生态文明。 1.2、规划目标 为贯彻落实科学发展观,稳步推进生态市和新农村建设,提高农村生活污水的收集处理率,实现天尊寺水库地段引用水 源质量的基本改善,有效恢复农村河网的自净能力,改善该人居环境,提升村民生活质量。 本工程设计污水收集率达到85%以上,农村生活污水治理农户受益率达到85%以上,满足规划目标要求。 1.3、工程概况 江油市新安镇天岭村共有村民62户,约208人。该村处于场镇附近山区,常住人口较多,本次污水收集处理从天岭村至新安中学段DN400双臂波纹管2300污水井检查井58座采用砖砌检查井。收集污水经检查井过滤后直接排放至新安镇污水处理厂。根据该村情况及要求,该村处理水排放标准需达到一级B标准。 第二章设计标准 2.1、设计依据及标准 (1)《中华人民共和国环境保护法》(1989年12月) (2)《中华人民共和国水污染防治法》(1996年5月修正) 1

(建筑给排水工程)排水管网设计说明书、计算书

(建筑给排水工程)排水管网设计说明书、计算书

一排水管网设计说明书1 1总论1 1.1 设计依据1 1.2 城市概况原始资料1 1.3 设计原则3 1.4 设计范围和任务3 2方案选择和确定4 2.1 排水体制的确定4 2.2 工业废水与城市排水系统的关系选择5 2.3 污水处理方式的选择5 3污水管网工程设计8 3.1 污水管网定线8 3.2 污水设计流量10 3.3 污水管道的水力计算13 3.4 污水管道水力计算成果19 3.5 污水管网工程量统计20 4雨水管网工程设计21 4.1 雨水管网定线21 4.2 雨水设计流量22 4.3 雨水管道的水力计算24 4.4 雨水管道水力计算成果26 4.5 雨水管道工程量统计27

5结论28 附:一张A3总平面布置图29 二排水管网设计计算书30 1污水管道设计计算30 1.1 污水设计流量公式30 1.2 计算举例32 1.3 街区编号及面积计算32 1.4 居住区生活污水设计流量计算33 1.5 工业污水设计流量和工业企业生活污水及淋浴污水设计流量计算34 1.6 污水管道水力计算35 1.7 污水厂规模的确定43 2 雨水管水力计算44 2.1 暴雨强度公式44 2.2 雨水管渠设计重现期44 2.3 雨水管渠的降雨历时44 2.4 径流系数45 2.5 雨水管道一般规定46 2.6 划分设计管段和汇水面积、汇水面积编号46 2.7 雨水管道设计流量和水力计算47 三个人体会50 四参考书籍52

一排水管网设计说明书 1总论 1.1设计依据 1.1.1主要规范 (1)《城市排水工程规划规范》(GB50318-2000),国家质量技术监督局、建设部 (2)《室外排水设计规范》(GB50014-2006),国家计委、建设部 (3)《泵站设计规范》(GB/T50265-97),国家质量技术监督局、建设部 1.1.2主要标准 (1)《污水综合排放标准》(GB8978-1996) (2)《污水排入城市下水道水质标准》(CJ3082-1999) 1.1.3参考书籍 (1)《水泵机水泵站》(第四版)(1998年)中国建筑工业出版社姜乃昌主编 (2)《给水排水设计手册(1、5)》(第二版)(2000年)中国建筑工业出版社 (3)《给水排水工程快速设计手册(2、5)》(第一版)(1996年)中国建筑工业出版社 (4)《全国通用给水排水标准图集(S1、S2)》(1996年)中国建筑标准设计研究所 (5)《水工业工程设计手册水工业工程设备》(第一版)(2000年)聂梅生主编 (6)《排水工程》(上册,第四版)(1999年)中国建筑工业出版社孙慧修主编1.2城市概况原始资料 (1)城市(包括工业区)总平面图一张,比例为1:10000,等高线间距1m。

管网工艺设计说明

管网工艺设计说明

四川省南溪县城市生活污水处理工程 污水管网施工图设计说明书 1、工程概况 四川省南溪县城市生活污水处理工程污水管网工程服务范围包括:南溪县规划城区,服务区与《南溪县总体规划》(~2020)的远期面积相同,城市建设用地面积6.52平方公里,服务人口8万人。管网污水量总规模按2020年2万m3/d设计。 3月我院报出四川省南溪县城市生活污水处理工程初步设计,包括二条主干线(即主干1线、主干2线)。 根据南溪县发改局的意见,由我院进行的四川省南溪县城市生活污水处理工程污水管网工程施工图设计工作随南溪县建设计划分段实施。本册为主干1线、主干2线的部分施工图设计。 2、设计依据及主要设计设计规范 2.1设计依据文件 (1)《四川发展和改革委员会关于转下达四川省三峡影响区水污染治理新建项目核定概算的通知》川发改地区[ ]627号 (2)《四川省南溪县城市生活污水处理工程初步设计》北京市市政工程设计研究总院、 3月。 (3)《南溪县污水处理厂岩土工程勘察报告》(详勘)四川省泸州地质工程勘察院 10月10日。 (4)四川省南溪县城市生活污水处理工程1:1000地形图

(5)其它相关文件及会议纪要。 2.2设计采用的主要规范、标准 (1)《室外排水设计规范》(GB50014- )。 (2)《给水排水管道工程施工及验收规范》(GB50268-97)。 (3)《排水检查井》(02S515)。 (4)《给水排水制图标准》(GB/T 50106- )。 (5)排水工程强制性条文。 3、设计变更方面及需要说明的问题 本设计污水管线的管径、走向、平面位置等情况依据南溪县发改局提供的现况资料及地形图等进行了调整。 4、设计要点 4.1设计标准、参数与计算公式 4.1.1设计年限及规模 本设计管网污水量总规模按2020年远期设计。 本设计污水管网设计规模2万m3/d,最大污水量2.97万m3/d。 4.1.2模数确定 根据水量计算和分配,本工程服务范围内主要为城市居民生活污水和城区范围宾馆、学校、事业单位的办公生活污水及部分工业废水。因此污水计算模数均采用0.393升/秒·公顷。 4.1.3污水管道水力计算公式 流量公式

给水设计说明书

第一章设计资料 一、城市平面图一张,比例1:5000; 二、城市总人口:10.4万人;用水人口:100%; 三、城市平均房屋层数:5层; 四、工业企业情况,具体位置见平面图: 1、甲工厂: 生产用水量:1000吨/天 工作时间:第一班(0-8);第二班(8-16);第三班(16-24)热车间人数:5400人/天;一般车间人数:3600人/天 热车间淋浴人数:4860人/天;一般车间淋浴人数:360人/天 2、乙工厂: 生产用水量:500吨/天 工作时间:第一班(8-16);第二班(16-24) 热车间人数:5000人/天;一般车间人数:3000人/天 热车间淋浴人数:4500人/天;一般车间淋浴人数:300人/天五、该城市居住区每小时综合生活用水量变化曲线如下表:

六、该城市位于二区 七、投资偿还期:t=5年,折减系数:m=5.33,折旧系数:4%,重现期:P=3.6% 第二章设计要求 一、根据所给资料,确定取水建筑和净水建筑的地点。 二、分析全程用水量和一天内流量的变化情况。 三、计算界限流量和经济因素。 四、确定城市主要供水方向,并进行管网定线。 五、初步分配流量确定管径。 六、进行管网平差。 七、按平差结果确定水泵扬程。 八、消防校核和事故时,水泵流量扬程是否满足要求。 九、绘制管网平面图。 十、整理报告,装订成册,报告力求文字通畅,字迹清晰。 第三章用水量计算 一、居住区最高日生活用水量Q1 按居住条件,由课本附表1查得最高日生活用水量标准为150-240L/人·d,这里取200 L/人·d, 则Q1=200×0.001×104000×100%=20800L/人·d

雨水管道设计说明书

雨水管渠系统设计 一、设计资料与要求 试进行某研究所西南区雨水管道(包括生产废水在内)的设计和计算。并绘制该区的雨水管道平面图。已知条件: (1) 如图2-1所示该区总平面图; (2) 当地暴雨强度公式为)10/() lg 81.01(7002 45 .0m s L t P q ??+= (3) 采用设计重现期P=1a,地面集水时间min 101=t (4) 厂区道路主干道宽6m,支干道宽3.5m,均为沥青路面; (5) 各试验室生产废水量见表2-1,排水管出口位置见图2-1; (6) 生产废水允许直接排入雨水道,各车间生产废水管出口埋深均为1.50m(指室内地 面至管内底的高度); (7) 厂区各车间及试验室均无室内雨水道; (8) 厂区地质条件良好,冰冻深度较小,可不予考虑;

(9)出去的雨水口接入城市雨水道,接管点位置在厂南面,坐标为x=722.50,y=520.00, 城市雨水道为砖砌拱形方沟,沟宽1.2m,沟高(至拱内顶)1.8m,改点处的沟内底标高为37.70,地面标高为41.10m. 表2-1 各车间生产废水量表 (1)设计说明书一份; (2)管道平面布置图一张(A3); (3)管道水力计算图一张(A3); (4)管段水力计算表一份。

二、划分排水流域及管道定线 根据厂区的总平面布置图,可知该厂地形平坦,雨水和生产废水就近排入各雨水口。厂区内建筑较多,相应的交通量会比较大,故雨水管道采取暗管。雨水出口接入城市雨水道,城市雨水道为砖砌拱形方。 根据总平面图给出的标高绘制等高线,可知厂区西北高,东南低,局部有高地。再根据等高线合理布置雨水口,适当划分排水区域。根据地形、雨水口分布定管线,使绝大部分雨水以最短的距离排入街道低侧的雨水管道。拟将该厂区划分为16个流域。如图2-2所示。 图2-2 三、划分设计管段 根据管道的具体位置,在管道转弯处、管径或坡度改变出,有支管接入出或两条以上管道交汇处以及超过一定距离的直线管端上都应该设置检查井。把两个检查井之间流量没有变化且预计管径和坡度也没有变化的管段定位设计管段。并从管段从下游往下游按循序进行检查井的编号。 四、划分并计算各设计管段的汇水面积 各设计管段汇水面积的划分应结合地形坡度、汇水面积的大小以及雨水管道布置等情况而划定。地形较平坦时,可按就近排入附近雨水管道的原则划分汇水面积;地形坡度较大时,应按地面雨水径流的水流方向划分汇水面积。并将每块面积进行编号,计算其面积的数值。经简化,厂区的流水区域如图2-3所示,图中每一区域已包含街道及绿地在内,不仅仅是建筑面积。表2-1为地面标高表。表2-2为管道长度表。表2-3为汇水面积计算表。

城市给水管道工程设计说明书(DOC)

城市给水管道工程设计——某县城给水管网初步设计 课程名称: 专业名称: 班级: 学号: 姓名: 指导老师: 是否组长:

给水管网计算说明书 1 给水管网设计任务书 1.1 设计目的和要求 课程设计的目的,在于培养学生运用所学的理论知识,解决实际问题,进一步提高计算、制图和使用规范与技术资料的能力。 设计要注意贯彻国家有关的基本建设方针政策,做到技术上可能,经济上合理。为了达到这一目的,学生应该深入复习有关课程,充分理解它的原理,在此基础上,学会独立查阅技术文献,确定合理的技术方案,逐步树立正确的设计观点。通过技术能基本掌握给水管网的设计程序和方法,较熟练地进行管网平差,加强基本技能和运作技巧的训练。 1.2 设计题目 某县城给水管网初步设计 1.3 设计原始资料 1.3.1 概述 某县城位于我国的广东省,根据城市建设规划,市内建有居民区、公共建筑和工厂。详见规划地形图。 1.3.2 城市用水情况 城市用水按近期人口412000 万人口设计,远期(10年)人口增加10%,市区以5 层的多层建筑为主。 表1 生活用水变化规律表 时间企业用水变化 百分数% 居民用水变化百 分数% 时间 企业用水变化 百分数% 居民用水变化百 分数% 0-1 1.5 4.05 12-13 5.0 1.16 1-2 1.5 4.07 13-14 5.0 1.18 2-3 1.5 4.34 14-15 5.0 1.26 3-4 1.5 4.29 15-16 5.8 1.25 4-5 1.2 4.12 16-17 5.8 1.62 5-6 1.2 4.28 17-18 5.0 4.30 6-7 4.2 6.06 18-19 5.0 5.20 7-8 6.8 6.21 19-20 4.6 5.50 8-9 6.8 6.08 20-21 4.6 5.35 9-10 6.8 5.80 21-22 4.6 5.23 10-11 6.0 4.92 22-23 3.4 4.80 11-12 6.0 4.01 23-24 1.2 4.92

排水管网课程设计说明书

排水管网课程设计说明书学校: 姓名: 学院: 班级: 学号:

目录 第一章总论 (3) 1.1设计目的 (3) 1.2设计要求 (3) 1.3基本设计资料 (3) 第二章设计计算 (5) 2.1污水设计流量的计算 (5) 2.1.1城镇人口数计算 (5) 2.1.2设计流量的确定 (5) 第三章污水管网的布置 (11) 3.1划分排水区域与排水流域 (11) 3.2干管布置与定线 (11) 3.3管段设计流量计算 (12) 3.4街坊面积 (12) 第四章污水管网水利计算 (14) 第五章污水管网主干管纵剖面图 (18) 参考文献: (19)

第一章总论 1.1设计目的 通过运用课堂所学知识,完成某城镇排水管网的初步设计,以达到巩固基本理论,提高设计与绘图能力,熟悉查阅和使用技术资料,了解设计的方法与步骤,进一步使理论与实践相结合等教学要求。1.2设计要求 按完全分流制设计,达到初步设计程度,设计成果应为: 1.污水和雨水排水系统的总平面布置图各一张 2.污水总干管纵剖面图一张、某一雨水干管纵剖面图一张 3.设计计算与说明书 1.3基本设计资料 (一)城镇规划资料: 1.某城镇规划图 2.人口分布、房屋建筑、卫生状况:(见下表)

3. 各种性质地面所占百分比: (见下表) 4. 工、企业规划表:(见下表) 5. 工业企业的污水经局部处理后允许排入城镇下水道。 (二)气象资料: 1.土壤冰冻深度0.1m 左右; 2.年平均降雨量1400mm ; 3.暴雨公式: n b t p C A q )() lg 1(167++= ,其中A=20 , C=0.7 , b=19 , n=0.86 (三)水文及水文地质资料: 1. 河流水位:Max:101m , Min:95m , Average:97m . 2. 地下水位:离地面7-8m. 3. 地质:砂质粘土. (四)电力供应:有三相电源可供选择,电力供应正常。 (五)污水不用作农田灌溉。

给水管网课程设计计算说明书

《给水管网课程设计》 计算说明书 2012年 12月31日 目录

一、布置给水管网 (3) 二、设计用水量及流量计算 (5) 1、计算设计用水量 (5) 2、计算实际管长和有效管长 (5) 3、计算比流量、沿线流量、节点流量 (7) 三、管网平差计算 (9) 1、初步分配管段流量和设定水流方向 (9) 2、选择管径 (9) 3、初步分配各管段最高时流量以及管长、管径的选取 (9) 4、哈代-克罗斯法校核环状管网 (12) 5、确定水泵扬程H p并求出各节点水压和自由水头 (15) 四、管网核算 (17) 1、消防时的管网校核 (17) 2、确定消防校核后水泵扬程H p及各节点水压和自由水头··20 3、最不利管段发生故障时的管网校核 (21) 4、确定事故校核后水泵扬程H p及各节点水压和自由水头··24 五、成果图绘制 (26) 1、绘制给水管网平面布置图及节点详图和消火栓布置 (26) 2、绘制最高时给水管网平面布置图 (26) 3、绘制消防时给水管网平面布置图 (26) 4、绘制事故时管网平面布置图 (26) 六、总结 (27) 七、参考文献 (28) 一、布置给水管网

1、水源与取水点的选择 所选水源为D县南面的潇水河,取水点选在水质良好的河段即河流的上游,并且靠近用水区。 2、取水泵站和水厂厂址的选择: 取水泵站选在取水点附近,用以抽取原水。 水厂选在不受洪水威胁,卫生条件好的河段上游。由于取水点距离用水区较近,可以考虑水厂与取水泵站合建。 3、给水管网布置 (1)原则: 符合城市规划,考虑远期发展 保证供水安全、可靠 管网遍布整个供水区域 力求管线短捷 (2)布置形式: 该设计区域为D县中心城区,不允许间断供水,适宜布置成环状网,可靠性高,水锤危害小。 (3)选取控制点: 根据D县规划平面图,选择最高最远点最为控制点。 (4)定线: 干管:先布干管,延伸方向应和二级泵站输水到水池、水塔、大用户的水流方向一致,线路最短,遍布供水区域,干管平行间距为500—800m左右,沿规划道路,靠近大用户。 连接管:干管与干管之间用连接管连接形成环状网,连接管平行间距为800—1000m左右。 4、在规划平面图上布置给水管网(见下页,详图见图纸)

排水工程施工图设计说明文本资料讲解

排水工程施工图设计 说明文本

精品资料 仅供学习与交流,如有侵权请联系网站删除谢谢2 西南大学内部道路工程雨水排水工程竣工图说明 一、竣工依据及遵循的规范和设计原则: 1、建设方提供的该工程1:500现状地形图及综合管线物探资料 2、《西南大学内部道路施工图设计文件》(重庆市市政设计研究院) 3《西南大学内部道路工程管网综合规划》(重庆市规划设计研究院) 4、场踏勘的实际情况 5、家相关规范和标准 《室外排水设计规范》(GB50014-2006)(2014版) 《室外给水设计规范》(GB50013-2006) 《给水排水工程构筑物结构设计规范》(GB50069-2002) 《给水排水工程管道结构设计规范》(GB50332-2002) 《城市工程管线综合规划规范》(GB50289-98) 《给水排水管道工程施工及验收规范》(GB50268-2008) 《给水排水工程构筑物工程施工及验收规范》(GB50141-2008) 《埋地聚乙烯排水管管道工程技术规程》(CECS164-2004) 《重庆市市政公用工程初步设计文件编制技术规定》。 6、工程的竣工原则是: 1)执行国家关于环境的保护政策,符合国家的有关法规、规范及标准; 2)以城市总体规划和片区控制性详细规划及现状管线为指导,在道路设计的基础上,对该项目的排水进行系统的工程设计,为规划区内人口和经济增长提供安全的水环境。 3)排水管网设计应满足地区经济和社会长远发展的需要,同时注意远期发展与分期实施相结合的原则。排水管道均按远期设计,并能适应片区建设需要,考虑分期实施的可能性。 4)新建排水管网充分考虑区域排水现状及地块建设的情况,结合地块建设规划,在排水管道断面、平面布置、高程布置上适应功能的需要和接入的可能性、便利性。 5)排水管网设计注意技术性与经济性相结合。尊重事实,在满足设计标准的前提下,尽量考虑利用现有管网体系和排水设施,并将其整合以发挥功能。 6)施工选材在不断总结科研和工程实践的基础上,既考虑技术发展的趋势,积极推动新技术、新工艺、新材料的应用,同时又兼顾经济投入的合理性。不得使用淘汰产品及与国家产业政策不符的材料和产品。 7)排水管道的平面、高程布置充分考虑各种城市管线的敷设走廊,在考虑经济性的同时预留足够的空间,为管线综合提供条件。 二、工程概述: 本项目位于重庆市北碚区西南大学农林区校园内,道路起点位于西南大学3号门入口,连通现状天生路,道路向西北方向延伸与在建体育场后车行道出口相接,主路全长133.29m,设计车速20km/h,路幅宽度为20m,车行道宽12m,双侧人行道宽4m。 由于路幅宽度限制,本次综合管网横断面设计中各种管线均按照单侧敷设考虑。雨水管单侧布置在西南侧人行道下。 三、上阶段专家意见及执行情况:

相关文档
最新文档