GRR标准型(公差)千分尺 13.35

上限値superior limit

value

下限値lower limit value 単位unit 規格

13.48

13.30

mm

測定回数numerical order

第-人First person 吴才跃Caiyue Wu

第二人Second person 李华Hua Li

No.

1次First time

2此Second time

3次Third time

範囲R value R

1次First time

2此Second time

3次Third time

範囲R value R

113.38713.38613.3850.00213.38513.38813.3870.003213.38313.38213.3820.00113.38313.38513.3850.002313.39513.39713.3960.00213.39713.39913.3980.002413.39013.39413.3940.00413.38613.39413.3950.009513.38913.38213.3830.00713.38413.38413.3840.000613.39113.38913.3930.00413.39013.39413.3920.004713.38413.37913.3830.00513.38513.38513.3850.000813.38813.38413.3840.00413.38913.38913.3880.001913.39213.39013.3900.00213.39413.39413.3940.0001013.384

13.382

13.385

0.003

13.385

13.385

13.383

0.002

平均ave

13.39

13.3913.39

13.39

13.3913.39

X A =13.3874

X B =

13.3889

R A =

0.0034

R B =

0.0023

R A 0.00X A 13.39UCL R = (R) * D 4

R B 0.00X B 13.39R C 0.01X C 13.38=

0.0094

R

0.0036

X diff

0.0051

解 析 (analysis)

EV = ( R ) * ( K 1 )

% EV = 100 *

=

0.01

測定回数checking times

K 1

=

3 3.05

AV = SQRT [{(Xdiff)*K 2 }^2 -{ (EV)^2/(n*r)}]

% AV = 100 *

=

0.01

測定者数checker acount

K 2

=

GAUGE R&R 評価表

GAUGE R&R evaluation sheet

brush holder 3134340238

13.35※ 仅在粗框内登录DATA

※ just register data in the sheet below

範囲R超出UCL R 时,需再測定.

Please check again when Value R goes beyond UCL R

千分尺micrometer 85009062

部品名

component name 測定項目measuring items 測定器

admeasurement instrument 計測器管理No.

No.of admeasurement instrument

对公percenta

解析和評価

analysis and evaluation

※ 全部計算将信頼区間5.15σ(=正規分布的99%的領域)作为基本。

※ All calculations are based on the trust region 5.15σ(=99% areas of bell curve of interm

反复性 EV ( =測定器引起的変動 )

repeatable EV(=changes caused by checking instruments)再現性 AV ( = 測定者引起的変動 )

reappearable AV(=changes caused by checkers)