余吾煤业N1203综采工作面综合灭火措施

余吾煤业N1203综采工作面综合灭火措施

贾文安

(潞安集团余吾煤业有限责任公司,山西长治046103)

摘要:通过对余吾煤业N1203综采工作面发火原因的分析,制定了综采工作面的综合灭火方

案,详细阐述了火区封闭与惰化,从地表施工钻孔注CO

2

、注氮,注凝胶封堵和气体监测等综合防灭火技术在此灭火实例中的运用,为防治综采工作面的重大火灾事故提供宝贵的经验。

关键词:综采工作面;防灭火;封闭;注惰

中图分类号:TD75+2.2文献标志码:B文章编号:1003-496X(2012)01-0080-04

The Comprehensive Fire Extinguishing of N1203Fully Mechanized Working Face in Yuwu Coal Industry

JIA Wen-an

(Lu'a n Group Yuwu Coal Industry Co.,Ltd.,Changzhi046103,China)

Abstract:Through the analysis of the fire causes in N1203fully mechanizd working face of Yuwu coal industry,a comprehensive fire extinguishing program was developed.The paper elaborated on the fire area closure and inerting.The comprehensive fire extinguishing

methods of injecting CO

2

,nitrogen,gelatin from surface drilling and gas monitoring were used in fire extinguishing instance,which provide valuable experience for controlling fire diaster in fully mechanized working face.

Key words:fully mechanized working face;fire extinguishing;closed;injecting inert gas

1工作面概况

余吾煤业公司矿井设计生产能力为600万t/a,属高瓦斯矿井,通风方式为分区式通风。发生事故的N1203综采工作面位于北一采区,工作面采用走向长壁、后退式大采高低位放顶煤一次采全高全部垮落式综合机械化采煤法。工作面走向长1024m,切眼长度300m,可采储量263万t。该工作面2010年7月开始回采,至2011年6月22日发生事故时,剩余可采长度80m。

工作面采用两进、两回双“U”型通风系统,工作面总风量为5592m3/min,其中回风顺槽回风1420 m3/min,瓦排巷回风4172m3/min。N1203工作面自2009年5月份开始掘进顺槽,此过程严格执行“边掘边抽和采前预抽”,工作面采取了采前预抽、边采边抽和采空区抽采等综合抽采方式,抽采后N1203工作面煤层瓦斯解析量为6.72m3/t,目前,绝对瓦斯涌出量为44.2m3/min。

2发火过程及原因分析

2011年6月22日零点班生产时,7:50左右,N1203综采工作面机头方向49#支架附近突然有较大的顶板来压声,工作面局部出现片帮漏矸,与此同时支架前梁附近煤墙顶板处发生着火,着火瞬间工作面出现较大烟雾。烟雾过后,立即组织人员用灭火器进行灭火,并同时向调度室进行了汇报。由于着火点位置位于支架前梁顶部,灭火器无法有效灭火,遂命令现场人员撤离,矿调度室接到汇报,迅速启动火灾应急预案,将北翼采区全部人员迅速撤离升井,无人员伤亡。

发生着火前,工作面有明显的顶板来压声响,同时工作面煤墙有片帮漏矸现象。经相关专家初步分析认为,顶板来压造成工作面机组后滚筒附近顶梁上部瓦斯突然大量涌出,同时顶部煤矸冒落摩擦支架前梁或采煤机割底板产生火花,引起局部瓦斯爆燃。

3综合灭火措施

经救灾人员到井下进一步探查,现场发现着火点范围较大且位置处于支架逼帮板上下,火焰呈蓝色火苗,现场已不具备直接灭火条件。抢险救灾指挥部通过对火情的分析和判断,确定采用“封闭火区、惰化火区和打钻灭火”综合防灭火方案,并且迅速成立了专家技术、钻孔施工、惰化施工等9个抢险小组,明确了各小组成员职责和工作任务,严格按照封闭、惰化、灭火程序开展救灾,具体实施步骤流程

·08