盐雾测试报告 中英文对照全面

盐雾测试报告 中英文对照全面

1. Test diagram & test method 测试图示和方法

2. Test result 测试结果

5PCS

/

2014-9-21

Salt spray test machine DJS-EN61盐雾试验机:DJS-GU-358Test environment 测试环境Drawing NO.

工程图号HDMI M/M Ni Plated 30AWG OD:5.0 L=1.5/2.0M Black

/Sample Q'ty 样品数量

Part/No.产品料号Test machine 测试设备温度:28℃/湿度:75%

SHENZHEN EAST-TOPTECH ELECTRONIC TECHNOLOGY CO.,LTD

深圳市东景盛电子技术有限公司

Salt spray Test Report 盐 雾 测 试 报 告

Product name 产品名称

Product spec.

产品规格

HDMI AM TO AM 30AWG 1.4REV. OD :5.0mm Length :1.5/2.0M

Customer 客户名称/

Test date 测试日期

Note 备注

According to GB/T10125-1997OK Sample No.

OK Test result description 结果描述

Judgement 综合判定

2#3#4#Test Item 测试项目

Salt spray test 盐水喷雾试验

Result of measurement 测 试 结 果

Test Requirement 测 试 要 求

6.8Reference 参考

6.5~

7.235±2℃35±2℃1.0-2.0ml(80cm 2

/H)

5#■ PASS 合格 □ NG 不合格

After ( 24 ) hours, test surface has no red phenomenon such as corrosion, bubble, crack After ( 24 ) hours, test surface has no red phenomenon such as corrosion, bubble, crack After ( 24 ) hours, test surface has no red phenomenon such as corrosion, bubble, crack

OK OK OK

Judgement 判定

35℃35℃1.00KG/CM 2

25°GB/T10125-1997

1.5ml 24H

After the test, take out the sample on the interior, natural drying 0.5 1 h, and then use clean flow of temperature is not higher than 35 ℃ water gently cleaning to remove the sample surface residual salt spray solution, then blow dry.试验结束后,取出试样放在室内,自然干燥0.5-1H,然后用温度不高于35℃的清洁流动水轻轻清洗以除去试样表面残留的盐雾溶液,再用吹风机吹干。

To 20 times a magnifying glass to observe, the surface has no red

phenomenon such as corrosion, bubble, crack, Judged to be qualified 。以20倍放大镜观察,表面无红色腐蚀物、气泡、裂纹等现象,即判定合格.After ( 24 ) hours, test surface has no red phenomenon such as corrosion, bubble, crack After ( 24 ) hours, test surface has no red phenomenon such as corrosion, bubble, crack Actual record 实际记录值

5%1#47℃85﹪RH

Collected volume of salt spray 盐雾收集量Test time 试验时间

2014-9-21 : 8:00

~2014-9-22 :8:00

Saturated air barrel temperature 饱和压力桶温度Test room relative humidity 试验室相对湿度Pressure of compressed air 压缩空气压力Sample place angle 样品放置角度47±1℃85±2%RH 1.00±0.01KG/CM

2

15~30°Salt solution barrel temperature 盐水桶温度Setting 设置5±1%Condition items 条件项目

Concentration of salt solution 盐水浓度PH of salt solution PH 值

Test room Temperature 试验室温度 表单编号:DJS-QR-045