【摘要】给水除氧器系统是我厂二回路热力循环中的重要组成部分,同时也是二回路水

质控制的关键设备。该系统的正常运行对电厂的安全经济运行有着重大意义。本文对秦山第二核电厂给水除氧器的工作原理作了简要介绍;并阐述了在机组运行期间除氧器水位和压力的控制。

【关键词】给水除氧器;水位控制;压力控制

【Abstract】Feedwater deaerator system is an important part of our factory second loop hermodynamic cycle, and it is also the key equipment of the second loop water quality control . The normal operation of the system is of great significance to the safe and economic operation of the power plant. In this paper, the working principle of Qinshan Second Nuclear Power Plant feedwater deaerator were briefly introduced; and expounds the deaerator water level and pressure control in the operation of the unit.

【Key words】Feedwater deaerator; Control of water level; Pressure control

0 引言

秦山第二核电厂给水除氧器系统是二回路主要热力循环中的一个重要组成部分。该系统接收低压加热器系统供给的初步升温的给水,经本系统加热除氧后,送往主给水系统,再经高压加热器系统加热达到要求温度后,送往核岛蒸汽发生器。在机组正常运行时,本系统所需的加热蒸汽,由汽轮机 LP1 和LP2 低压缸第 2 级后抽汽供给。我厂采用的是基于热力方法分离活性气体的卧式喷雾淋水盘式热力除氧器。电厂实际运行经验表明,越是高参数、大容量机组,除氧设备及除氧效果要求越高。

1 给水除氧器系统结构及工作原理

我厂的除氧器采用了喷雾除氧段和淋水盘式深度除氧两段除氧结构,具体结构如图1和图2所示。当凝结水进入除氧器后,进水分两路均匀地进入除氧器上部的两个独立水室,在两进水室的长度方向各均匀布置了125只16T/h的恒速喷嘴。因凝结水的压力高于除氧器的汽侧压力,水汽两侧的压差△P作用在喷嘴上,使凝结水在喷嘴中喷出,呈现一个圆锥形水膜进入喷雾除氧段空间,在这个空间中逆向流动的过热蒸汽与圆锥形水膜充分接触,迅速把凝结水加热到除氧器压力下的饱和温度,绝大部分的非冷凝气体均在喷雾除氧段中被除去。穿过喷雾除氧空间的凝结水喷洒在淋水盘箱上的布水槽钢中,布水槽钢均匀地将水分配给淋水盘箱。淋水盘箱由多层一排排的小槽钢上下交错布置而成,凝结水从上层的槽钢两侧分别流入下层的槽钢中一层层地交错流下去,使凝结水在淋水盘中有足够停留时间且与蒸汽接触使热交换面积达到最