1. Specifications ....我规格........................................... 1

2. Composition ....组成............................................7

3. preventive Maintenance ...预防性维修...................................8

4. Calibration .....校准.............................................10 4.1 Calibration Interval ....校准间隔.......................................10

4.2 Test Equipment Required ...测试所需设备...............................10 4.3 preliminary procedure ....初步程序..................................10

4.4 preliminary Control Settings...初步控制设置...............................12

4.5 Initial Starting procedure ....初始启动程序..............................12

power Supply System ......供电系统...............................13

Display .....显示..............................................14

Horizontal System ....横向系统............................................16

Vertical System .....垂直系统.............................................20

Triggering System & X—Y Operation ...触发系统和XY操作........................24

Calibrator ......校准..................................................28

5. Disassembly Illustration .....拆卸.插图.................................29 6. Circuit Board Illustration (with Adjustment Locations) ..电路板图(与调整位置)......31

7. Diagram ......图...............................................39

(1) Schematic Diagram (Vertical preamplifier) .示意图(垂直前置放大器)...................41

(2) Schematic Diagram (Vertical Output Amplifier & Channel Switch) 示意图(垂直输出放大器与通道开关)............................................43

Schematic Diagram (Trigger 1/2) ......示意图(触发1/2)...........................45

Schematic Diagram (Trigger 2/2) ....示意图(触发2/2)........................... 47

Schematic Diagram (Sweep Generator) ......示意图(扫描发生器)........................49

Schematic Diagram (Calibrator & Front panel Controls..原理图(校准与前面板控制.............51

Schematic Diagram (Horizontal Amplifier, Z—Axis Amplifier & High Voltage Circuits).(水平Z轴放大器,示意图高电压放大器电路).................................53

Schematic Diagram (Power Supply) .....示意图(供电)...........................55 Schematic Diagram (Connectors) ......示意图(连接器)..............................57 8. parts list ......零件清单..................................................59 Electrical Replaceable parts List ....电器更换零件清单...........................59 Mechanical Replaceable parts list ...机械更换零件清单............................118

1.SPECIFICATIONS 规格

CRT 阴极射线管

Type 型号

Hitachi 150BNB3l rectangular mesh type tube With 20 KV --日立150BNB3l矩形网格型管20KV acceleration potential and metal backed phosphor 加速电位及金属磷

Screen type 屏幕类型

P3l phosphor Standard p31荧光粉标准

Usefu1 Screen area 有效屏幕面积

8 X 10 div (div :10mm) 8×10(分度值:10毫米)

Graticule 基线

Internal graticule With Centimeter divisions and 2mm内部网格划分2毫米

Subdivisions along the centeral axis 10%and 90%lines are 分支沿中心轴10%和90%线indicated.illumination Continuously Variable.照明连续变量表示

Focussing 聚焦

possible (With automatic focus correction circuit) 可能的(自动聚焦校正电路)

Trace rotation present 前置微调旋钮

Scale illumination Variable 规模照明变量

Brightness adjustment possible 亮度调整可能

●Z—AXIS Z轴

●DC—coupled,positive—going Signal decreases intensity:5Vp—p

●正向信号耦合,降低强度:5vp-p

●Signal causes noticeable modulation at normal intensity:信号导致明显的调节在正常强度:●DC to 3.5MHZ.直流3.5MHz。

●Input impedance Approximately 15 k Ohm 输入阻抗约15欧姆

●Maximum input voltage 20 V (DC + AC peak) 最大输入电压20伏(直流+交流峰值)

Coupling DC 直流耦合

VERTICAL DEFLECTION (2 Identical Channels) 垂直偏转(2通道)

Bandwidth and Rise time 带宽与上升时间

DC to at 1eaSt 100MHZ and rise time 3.5nS Or less,直流到至少100 MHz和上升时间3.5ns或更少,

DC to at leaSt 5MHZ and riSe time 70nS or less at magni fier extends,Lower -3dB point,AC coupling 10Hz or less.

直流至少5兆赫和上升时间70ns或更少的延伸率,低点-3dB,交流耦合10 Hz或更少。

DefleCtiOn Factor 偏转因子

5mV/div to 5V/div in 10 calibrated Steps,l-2-5 Sequence.

5mv/分区/分区10个校准步骤,l-2-5序列。

Uncalibrated continuous control extends deflection factor 标定连续控制延伸偏转因子

to at least 12.5 volts per division in the 5 volts/div position.至少12.5伏特每部5伏特/格位置。×10 magnifier increases sensitivity of each deflect- tion factor setting to 500 μV/div.

×10放大镜的敏感性增加每个转移化因子设置500μV/格。

Accuracy 精度

±2%(+10℃to +35℃)

±4%(0℃to +50℃)

Additional error for magnifier ±l%附加误差放大±1%

DiSplay modes 显示模式

CH1,CH2 (normal or invert),Alternate,Chopped (250kHz rate),Added Input Impedance

CH1,CH 2(正常或倒置),互生,切碎(250 kHz速率),添加输入阻抗

lM Ohm ±1.5%in parallel with 28pF ± 3pF.长征1.5%欧姆±平行28pf±3pf。

Maximum Input voltage 最大输入电压

250V (DC + AC peak) or 500Vp-p AC at 1KHz or less

250 V(直流+交流峰值)或500vp-p交流在1 kHz以内

Input coupling 输入耦合

AC—GND—DC

Delay Line 延迟线

permitS viewing 1eading edge of display waveform.允许查看1eading边缘显示波形。

Four-trace Display (TRIG VIEW) four-trace显示(触发视图)

Display simultaneously channel 1,Channel 2,Channel 3 同时显示通道1,通道2,通道3

(A EXT TRIG Signal) Channel 4 (B EXT TRIG signal)(一个外部触发信号),4频道(二外部触发信号)。The deflection factor of Channel 3 and Channel 4 iS 偏转因子3通道和4通道

approximately 200 mV/div.约200毫伏/分格。

Sensitivjty INT:l/l ± 30%of screen area sensitivjty诠释:我/我±30%屏幕面积

EXT:0.2 V/div ± 30%分机:0.2伏/分区±30%

Frequency band EXT:DC to 70 MHz (-3dB) 频段内线:直流70兆赫(-3分贝)

position CH3:Horizontal 100%graticule line of 位置控制:卧式100%标线

screen ± ldiv (trigger level knob is Set at the center).屏幕±ldiv(触发电平旋钮设置在中心)。

CH4:Horizontal 0%graticule line of CH4:水平0%标线

screen ± 1div.±1div屏幕。

HORIZONTAL DEFLECTION

Time BaSe A

20nS/div to 0.5S/div in 23 calibrated Steps,l-2-5 Sequence.

Uncalibrated continuous control extendS deflection factor

to at leaSt 1.25 Seconds per division in the 0.5 Sec/div

position,x10 mag extends fastest sweep rate to 2nS/div.

Time BaSe B

20ns/div to 50ms/div in 20 calibrated steps l-2-5 sequence.x10 mag extends fastest sweep rate to 2ns/div.

Accuracy

±2%(±10℃to +35℃)

±4%(0℃to +50℃)

Additional error for magnifier ±2%

Horizontal DiSplay Modes

A only,A intensified,Alternate,

B delayed,X—Y operation.Delayed sweep position 1 div or less ~10 div or more

adjustment

Delay sweep variable present

Delay Time Jitter Better than l:20,000

TRIGGERING A AND B

A Trigger Modes

Automatic,Normal,Single sweep,TV (TV-H Or TV-V)

A Trigger Hold-off

Adjustable control permits a stable presentation of

repetitive complex waveform.

A Trigger source

Internal (Ch l,Ch 2),Line,External,External ÷10

A Trigger siope

+ or -

TV Sync polarity

TV(+) or TV (-)

Triggering 1evel For both A and B.Internal;±4div or more variable range External;approximately ±lV

External ÷10;approximately ±10V Triggering sensiti- For both A and B.However,( ) is only vity and frequency for B

Frequency Internal External External÷10

DC(30Hz) ~ 10MHz 0.3 div 50 mV 500 mV

10 MHz ~ 100MHz 1.5 div 150 mV 1.5 V

TV—V sensitivity:SYNC section less than 0.7div or 200mV

AUTO low band:Approximately 30Hz (When Time BaSe A

is 20ns/div to 2ms/div)

A Trigger Coupling

AC:30Hz to full bandwidth

HF REJ:attenuates Signals below approximately 4KHz

LF REJ:attenuates Signals above approximately 4KHz

DC:0 to full bandwidth

A External Trigger Inpt ImpedanCe

lM ohm ±20%in parallel with 28pF ±6pF (However,setting

HF REJ and LF REJ are not inciuded.)

Maximum Input voltage

250V (DC + AC peak)

500Vp—p AC at lKHz or less

B Trigger Modes and Source

Automatic,Normal (Ch l,Ch 2,External)

B Trigger slope

+ or -

Trigger Coupling

AC oilly;30Hz to full bandwidth

●X—Y OPERA TION (CH l;Horiz,CH2;V ert)

Deflection Factor

Same as vertical deflection

Accuracy

Y:±2%(+10℃to +35℃),±4%(0℃to +50℃)

X:±5%(+10℃to +35℃),±7%(0℃to +50℃)

Additional error for magnifier ±2%

X—Baildwidth

DC to at least 2MHz

Phase Error

3°or less from DC to 2MHz

CALIBRA TOR

0.5V±l%Frequency lkHz±l%square wave

Rise time 5μs or less

●OUTPUT SIGNALS

A GA TE OUT TTL 0UTPUT(74LS00with OUTPUT series

resiStance 100Ω)

一 5 一

B GA TE OUT TTL OUTPUT (7400 with OUTPUT series

resiStance 100Ω)

●POWER SUPPLY

VOLTAGE (50/60Hz) FUSE

100 V ( 90 ~ 110 V) 2A

120 V (108 ~ 132 V) 2A

220 V (198 ~ 242 V) 1A

240 V (216 ~ 264 V) 1A

Nominal vo1tage ±5%at 400Hz

power supply frequency:50,60,400Hz

power consumption :Approximately 60W

●ENVIRONMENT

Limit of operation temperature 0℃~ 50℃

Limit of operation humidity 35%~ 85%

Rated range of use temperature 10℃~ 35℃

Rated range of use humidity 45%~ 85%

Strage afld transport -20℃~ 70℃

DIMENSION AND WEIGHT

310W ×180h ×410d mm

(12.2w x×7.1h ×16.1d in)

10.2kg (22.5 lbs)

2. COMPOSITION

(1) Model V-1050 oscilloscope unit........................ 1

(2) probe (A T-10AE 1.5)................................... 2

(3) Fuse (2A for 100V and 120V set

or lA for 220V and 240V set).................... 1

(4)Screw-driver.........................................1

(5)Dust proof cover......................................1

(6) power supply cord..................................1

(7)Operation Manual..................................1

3.PREVENTIVE MAINTENANCE

Preventive maintenance,when performed on a regular baSis,

can prevent instrument breakdown and may improve the reliability of the oscilloscope.The Severity of environment to which this instrument is subjected will determine the frequency of mainte—

nance.A convenient time to perform preventive maintenance is preceding recalibration of the inStrument.

Disassembly

Remove the 4 screws in the top cover of the instrument.Gently Separate the top cover from the inStrument and lay aside,Most of the internal parts of the inStrument are now accessible.if access to the front of the circuit boardS are necessary,remove the knobs from the external control shafts on the board.Remove the two screws Securing the Side panel to the Input

Circuit board and remove the inStrument Side panel.(See 5.DISASSEMBLY ILLUSTRA TION.)

Cleaning

The instrUment should be cleaned as often as operating con—ditions require.accumulation of dirt in the inStrument can

cause component breakdown,

The covers provide protection against dust in the interior

of the inStrument.Loose dust accumulated on these covers can

be removed with a soft cloth or small brush.

Dirt that remains can be removed with a soft cloth depended

in a mild detergent and water solution.Abrasive c1eaners should not be used.

Cleaning the interlor Should only be occaSionally necessary.

The best way to clean the interior is to blow off the dust with

a dry,low—velocity Stream of air.A soft—briStle brush or a cotton—tipped applicator is useful for cleaning in narrow Spaces

or for cleaning more delicate components.

Visual InSpection

The inStrument Should be inspected occaSionally for such

defects as broken connections,improperly Seated transistors,

damaged Circuit boards,and heat—damaged parts.The corrective procedure for most V iSible defects is apparent;however,parti—

cular care must be taken if heat—damaged components are found.overheating usually indicates other trouble in the instrument;therefore,correcting the cause of the overheating is important

to prevent recurrance of the damage.

4.CALIBRA TION.

Hitachi Denshi,Ltd.proyides complete instrument repair and recalibration at our overseaˊs office,and authorized dealer.Contact your local Hitach Denshi,Ltd.Office or representative.4.1 CALIBRA TION INTERV AL

TO maintain instrument accuracy,perform the calibration of

the V—1050 at least every 1000 hours of operations or every

Six month if used infrequently.

4.2 TEST EQUIPMENT REQUIRED

The folloWing test equipment and accessories,or equivalent,

are required for the complete calibration of the V—1050.The

giyen Specifications for the test equipment are the minimum

necessary for accurate calibration.Therefore,the Specifica-

tions of any test equipment used must meet or exceed the listed Specifications.All the test equipment is assumed to be cor-

rectly calibrated and operating within the liSted Specification.

Operating instructions for the test equipment are not given in

thiS procedure.Refer to the instruction manual for the test

equipment if more information is needed.‘

4.3 PRELIMINARY PROCEDURE

ThiS instrument Should be calibrated at an ambient temperature

of +20℃(±5℃) for best overall accuracy.

1.Corlrlect the instrument to AC line voltage,50/60/400 Hz 1ine source.

2.Set the ilistrument controlS as given in the preliminary Control Settings.Allow at least fifteen minutes of

warmup before proceeding.

3.See the Adjustment Locations in the pUllout pages.

Table 4-l

TEST EQUIPMENT REQUIRED

Description Minimum specification Usage Examples of

Applicable

Test Equipment

1.Constant Signal

Generator

Amplitude 50kHz reference

frequency;

maximum frequency

150MHz;

V ariable amplitude.

Check horizontal,

V ertical and

trigger bandwidth.

Hitachi Part

NO.4202

2.Standard

Amplitude

Calibrator AmplitUde accuracy:

0.25%,

V ariable amplitude;

5mV to 40 V;

frequency:l kHz

Square wave.

Check horizontal

and V ertical gain

Hitachi Part

NO.4202

3.Square—Wave

Cenerator V ariable frequency:10

Hz to 1 MHz;output

amplitude;

10mV to 100 V.

Check probe and

vertical

compenSation.

Hitachi Part

NO.4202

4.Digital

Multimeter 0.1% accuracy Check power

supply

Hitachi Part

NO.4202

5.Digital

Frequency

Counter 0.1% accuracy Check CAL

frequency.

Hitachi Part

NO.4202

6.Time Mark

Generator 0.1% accuracy Check horizontal

timing.

Hitachi Part

NO.4202

7.Cable Impedance,50 ohms;

type,RC-58/U;length,

42 inches,connectors,

BNC External trigger

operation Check.

Horizontal gain

Check and

adjustment.

Hitachi Part

NO.4202

8.Termination Imedance,50 ohms;V ertical Amplifier Hitachi Part

Type,RG-58/U;length,42in Ches, connectors,BNC compen—Sation

checks and adjust

ment

NO.4202

9.Attenuator Ratio,10X;connectors,

BNC;impedance,50

ohms.V ertical Amplifier

band—width

check.

Hitachi Part

NO.4202

10.T-connector Connectors,BNC.External trigger

operation Checks.Hitachi Part NO.1301

4.4 PRELIMINARY CONTROL SETTINGS

preset the inStrument controls to the settingS given below,

When Starting the calibration procedures.

FOCUS Midrange Midrange

TRACE

ROTA TION

As desired V AR HOLD 0FF Fully counterclockwise V.POSITION Midrange,push in Fully clockwise,push in V.V ARIABLE CAL,fully clockwise DISPLAY A

AC-GND-DC GND —B TRIC—

VOLTS/DIV 5mV/DIV SOURCE AUTO

V.MODE CH l LEVEL Midrange,push in TRIG VIEW Normal(Button out) —A TRIC—

INV Normal(Button out) LEVEL Midrange,push in SCALE ILLUM Fully

counterclockwise

RESET Normal H.POSITION Midrange MODE Auto

Midrange,push in COUPLING AC

TIME/DIV A lms SOURCE CH1

DLY TIME MULT Midrange

4.5 INITIAL STARTING PROCEDURE

1.Rotate POWER/INTENSITY comtrol to the midrange.

2.Wait a few seconds for the cathode ray tube (CRT) to warm Up.A trace Should appear on the diSplay of the CRT.3.If trace disappears,increase (clockwise) the POWER/

INTENSITY comtrol setting until the trace is easily observed,

or ronghly check/adjust the DC balance to get a trace 15

4.Adjust FOCUS control for the best focused display.

5.Readjust POSITION comtrols if necessary,to center the trace.

POWER SUPPLY SYSTEM

NOTE

Before you begin,see ADJUSTMENT LOCA TIONS in the pullout pages.Control Settings

Preset the controls as giyen in the preliminary Control Setting.

1 check LOW—VOltage supply,if necessary

a.Connect the digital voltmeter (DVM) from the +12 volt line.

:+11.975 V to +12.025 V (pll04-3)

b.Connect the DVM from the —12 V line

:—11.75 V to —12,25 V (pll04-5)

C.Connect the DVM from the +5V line

:+4.75 V to +5.25 V (pll04—4)

d.Connect the DVM from the +55 V

:+53 V to 57 V (pll04—2)

e.Connect the DVM from the 100 V

:+98 V to +102 V (pll04一1) ,

2 Adjust LOW—voltage supply

Adjust the adjustment RV1112 for DVM reading of +12V (±0.025V).

3 check High voltage supply

a.Connect the DVM to the H.V test point (PEF─503—2) by High voltage probe.

b.Check for a reading if —1870 V ~ 一2030 V

DISPLAY

Contro1 Setting

preset the controls as given in the preliminary control Setting.

4 check/Adjust CRT Bias

DISPLAY switch to the position,and A TIME/DIV switch

to the l ms.

a.Rotate the POWER/INTENSITY to the “N”letter of the

“INTENSITY”as Shown.

b.Observe the trace of CRT.

c.Adjust Grid Bias Adjustment RVl040 for the trace makes an appear.5 check/Adjust Trace Rotation

a.Check that the trace is parallel to the cedter horizontal line.

b.Adjust TRACE ROTA TION for a trace that is paral1el with

the horizontal graticule lines.

6 Check/Adjust GEOMetry

a.Set the A TIME/DIV Switch to the lms,and AC—GND—DC to DC.

b. Connect the Constant Amplitude Signal Generator to the input.

c.Set the VOLTS/DIV Switch Setting for a full—screen (8

division) deflection.

d.Check that horizontal bowing is less than ±0.15 division.

e.Adjust the GEOM adjustment RVl035 for a display that is

parallel with top and bottom horizontal lines.

7 Check/ASTI Gmatism and FOCUS

a.V ertical Mode switch to the CH2 X-Y position and Display switch to

the X-Y position, and AC-GND-DC to DC

b.Set the POWER ON INTENSITY control for a small spot,as the

following figure, using position controls

c.Check that the Spot is round.

d.Adjust the FOCUS adjustment and the ASTIG adjustment RVl038

for a round Spot.

HORIZONTAL SYSTEM

Contro1 SettingS

preset the controls as giyen in the preliminary,coiltrol settings.

8 check/Adjust Delaytime

a.V ertica)- Mode switCh to the CHl position.

b.Set the A TIME/DIV switCh to the l mS.

c.Set the B TIME/DIV switCh to the 0.5 μS.

d.Set the input AC—GND—DC to DC,connect the cable to the output of the time mark generator,set the time mark

generator for l ms time marks.

e.Display switch to the INTEN.

f.Connect the cable to the output of the time mark generator.

g.Set the time mark generator for l mS time marks.

h.Set the DELAY TIME MULT dial to 1.00.

i.Check that intensified portion of the Sweep begins at the

second time marker (It may be necessary to readjust the

INTENSITY control,so that the intensified portion of the

sweep is visible.)

j.Adjust the RV562 so that the intensified portion of the

sweep begins at the start of the second time marker,k.Set the DELAY TIME MULT dial to 9.00.

1.Check that intensified portion of the sweep begins at the tenth time marker.

m.Adjust the RV560 so that the intensified portiOn of the

sweep begins at the start of the tenth time marker.n.Repeat both the RV562 and the RV560 adjustments for no V isible interaction.

9 check/Adjust Horizontal Gain

a. DISPLAY Switch to the A position.

b.Check that the time markS align with the graticule lines

Over the center eight divisiOns,within 2%.

c.Adjust H GAIN adjustment RV813 so that the time marks align With the Center eight graticule 1ines.

10 check/Adjust B sweepstart

a.Set the input AC—GND—DC to GND.

b.Set the A TIME/DIV switch to the 2 mS.

c.Adjust the position control so that the beginning of the A sweep is coincident with the first V ertical graticul-e 1ine d.Set the B TIME/DIV switch to the l ms.

e.DISPLAY switch to the B position.

f.Check that the beginning of the B Sweep is identical with the first V ertical graticule line.

g.Adjust the RV 714 so that the beginning of the sweep is identical with the first vertical graticule line.

11check/Adjust B sweep calibration

a.Set the input AC—GND—DC to DC.

b.Check that the time marks align with the graticule lines

over the Center eight divisions,within 2%.

C.Adjust B SWEEP CAL adjustment RV742 so that the time marks align with the center eight graticule lines.

12 check/Adiust Horizontal x10 MAG Gain

a.DISPLAY Switch to the A position,Set the A TIME/DIV switch to the l mS.

b.Set X10 MAG (pu11 out the inner knob of the POSITION control).c.Check that the one—cycle time marks align with the ten—divisions graticule lines,Within 2%。

d.Adjust MAG GAIN adjustment RV804 for one—cycle time marks align with the ten—divisions graticule lines;

e.push in the inner of the POSITION control after the adjust—ment and Check.

13 check/Adjust MAG CENT

a.Set the A TIME/DIV Switch to the 0.1 ms.

b.Being the inner Shuft of H. POSITION is in pulled out

State (X10 MAG),the left end of the trace is brought to

the Center point and then the inner shuft of H.POSITION iS

depreSSed.

C Observe the movement of the 1eft end of the trace.

d.Adjust the MAG CENT adjustment RV8ll for the movement of the 1eft end of the trace within ±0.2 div.

14 check/Adjust High speed sweep accuracy

a.Set the input AC—GND—DC to DC;

b.Display switch to the A position.

c.Set the time mark generator for 50 nS time marks.

d.Set the A TIME/DIV Switch to 50 ns.

e.Check that the time markS align With the graticule lines

over the center eight divisions.

f. Adjust CV530 at that the time marks align With Center

eight graticule lines.

g.Display switch to the B position.

h.Set the A TIME/DIV Switch to 0.2 μS.

i.Set the B TIME/DIV Switch to 50 nS.

j.Refer part (e) through (f) (in this Case,adjust CV730)

k.Display switch to the A position.

1.Set the A TIME/DIV Switch to 5 μs

m.Set the time mark generator for 5 μs time marks.

n.Refer part (e) through (f) (in this case,adjust CV534),

o.Display switch to the B position.

p.Set the A TIME/DIV Switch to 20 μs.

q. Set tbe B TIME/DIV SwitCh to 5 μs.

r.Refer part (e) through (f) (in this case,adjust CV 734).

S.Display switch to the A position.

t.Set the A TIME/DIV Switch to 20 ns.

U.Set the time markS generator for 20nS time marks.

v.Refer part (e) through (f) (in this case,adjust RV540).

W.Display switch to the B positiorl.

X.Set the A TIME/DIV switch to 50 nS

y.Set the B TIME/DIV switch to 20 ns.

z.Refer part (e) through (f) (in this case,adjust RV740).

α.Check all other ranges of timing within 2%.

Use appropriate settings on the time mark generator.

VERTICAL SYSTEM

Control Setting

prcset the controls as given in the preliminary control Settings.

15 check/Adjust DC Balance (step attenuator balance).

a.Set the VOLTS/DIV swiitch to the 5mV position.

b.Position the trace to the horizontal tenter line.

C. Chailge the VOLTS/DIV switch to the 10mV positioil.

d. Check that the trace is Within 0.1 division of the center

horizoiltal line.

e.Adjust the CH l (CH2) DC BAL adjustment,RV7 (CHl) or RVl07 (CH2),for a trace at the horizontal cellter 1ine

(DC BAL adjustment RV7 and RVl07 are possible to adjust at

the adjusting point oil the front panel.)

f.Repeat part (a) through (e) until less than 0.1 diVision

Shift iS noted when Changing the VOLTS/DIV setting.

16 check/AdjUSt V erticalpositioncenter.

a.confirm the vertical POSITION control at the midrange.

b.Check the trace is Within l diviSion.

c.Adjust the position Center adjustment RV73 (CHl),RVl73 (CH2) for a trace at the horizontal center lilie.

17 check/Adjust ADD BALANCE

a.Set the A TIME/DIV to the lms position,the Display switch to A.

b.Set the CH l and CH2 AC—GND—DC switchs to GND.

c.Set the V MODE switch to CH l.

d.Adjust the vertical positioil coiltrol that the trace is

identical With the center horizontal graticule line.

e.Next,set the V MODE switch to CH2 and adjust the vertical position control that the trace is identical with the

center horizontal graticuls line.

f.Set the V MODE switch to ADD.

g.Check that the trace iS identical With the center horizontal

graticule line within ±0.5 division.

h.Adjust ADD BAL adjustment RV327 for two times of the difference With the center horizontal graticule line.

18 check/Adjust X l AC GAIN

a.Set the A TIME/DIV switch to the lmS position.

b.Set the VOLTS/DIV switch to the 10mV position.

c.Set the AC—GND—DC switch to DC.

d.Connect the Square-wave generator (using lKHz out put range).

e.Adjust the output amplitude of that generator for 5

division deflection of screen.

f.Check the high-voltage level of pulse is flat.

g.Adjust the X l AC GAIN RV33(CH1),RVl33(CH2) adjustment for a flat level.

19 check/Adjust V ertical Gain.

a.Set the A VOLTS/DIV switch,to the 10mV position and AC—GND—DC switch to DC.

b.Connect the Standard amplitUde calibrator to the input.

c.Set the Standard amplitude calibrator for a 50mVp—p (5 divisions of diSplay) Signal.

d.Check for a display of five divisions.

e. Adjust GAIN adjustment RV339(CH l),RVl60(CH2) for a display

of 5 divisions within 2%.

f.Check a11 the VOLTS/DIV switch settings.

20 check/Adjust Input capacity (A TT:÷1).

a.Set the VOLTS/DIV switch to 10mV position.

b.Set the AC—GND—DC switCh to DC.

c.Connect the L—C meter to the input terminals.

d,Check the input capacity for approximately 28 pF.

e.Adjust CV3(CHl),CVl03(CH2) for a 28 pF input capacity.

21 check/Adjust V ertical step Response

a.Set the VOLTS/DIV switch to the 10mV position.

b.Set the A TIME/DIV switch to the 20 nS position.

c.Connect the fast—rise,positive output (50mV,lkMZ) of the Square—wave generator tO the inpUt.Use a 50一Ohm

Termirlation and cable.

d.Set the Square—wave generator to lMH2.Adjust the Square—wave generator outpUt for a 5-diViSions diSplay.

e. CHl —Set CV63 and RV63 tO the midpOSition.And adjUSt

CV325,CV342 and CV344 for a Square wave that

iS 士lat.Then,adjUSt CV63 and RV63 for over—Sh00t

that iS 十0.1 diV.

CH2 - Adjust CVl63 and RVl63 for over-shoot that is +0.1 div.

22 check/Adjust Attenuation compensation

(A TT :÷10,÷100,÷250)

a.Set the AC—GND—DC switch to DC.

b.Connect the Square—wave generator to the CHl (CH2) input terminal Check for a Square wave that is flat (f).at top)

under the following settings.

A TT VOLT/DIV The Squarewave generator output

÷10 50mV 0.25V

÷100 0.5V 2.5 V

÷250 5 V 25 V

C.Adjust the trimmer condensers (refer the Circuit bord illustration With adjustment location —page 37) for a

Squarewave that is flat (flat top) urlder the following settings.

A TT VOLT/DIV The Squarewave

generator output

Adjust CHl (CH2)

÷10 50mV 0.25V Comp—l/10

÷100 0.5V 2.5 V Comp—l/100

÷250 5 V 25.0V Comp—l/250

23 check/Adjust Input capacity (A TT:÷10,÷100,÷250)

a. Connect the L—C meter to the Input terminal.

b.Check the Input Capacity for a approximately 28pF.

c.Adjust the trimmer condensers for a 28pF Input capacity

dnder the following settings.

A TT VOLT/DIV Adjust

CHl (CH2)

÷10 10mV Cin—l/10

÷100 0.1V Cin—l/100

÷250 1 V Cin—l/250

TRIGGERING SYSTEM

24 cheok/Adjust A TRIG CENT

a.Set A TRIG SOURCE switch to CH1,A TRIG COUPLING switch to AC,A TRIG SLOPE knob push in,the VOLTS/DIV switch

to 10mV,the A TIME/DIV switch to 20μS.

b.Connect the Sine—wave generator to the input for a 0.3diV (50kHz).c.Set A TRIG LEVEL knob to the midposition.

d.Adjust RV44l so that Synchronization is effected on the

waveform,0.3diV on the screen.

e.Under the State of (d),if SynChronization is not effected by switching A TRIG COUPLING to “DC” set CHl(CH2) DC LEVEL

示波器的初级使用方法教程

示波器的使用方法教程 ST-16示波器的使用 示波器是有着极其广泛用途的测量仪器之一〃借助示波器能形象地观察波形的瞬变过程,还可以测量电压。电流、周期和相位,检查放大器的失真情况等〃示波器的型号很多,它的基本使用方法是差不多的〃下面以通用ST一16型示波器为例,介绍示波器的使用方法。 面板上旋钮或开关的功能 图1是ST一16型示波器的面板图。 示波器是以数字座标为基础来显示波形的〃通常以X轴表示时间,Y轴表示幅度〃因而在图1中,面板下半部以中线为界,左面的旋钮全用于Y轴,右面的旋钮全用于X 轴。面板上半部分为显示屏。显示屏的右边有三个旋钮是调屏幕用的〃所有的旋钮,开关功能见表1。其中8、10,14,16号旋钮不需经常调,做成内藏式。

显示屏读数方法 在显示屏上,水平方向X轴有10格刻度,垂直方向Y轴有8格刻度〃这里的一格刻度读做一标度,用div表示〃根据被测波形垂直方向(或水平方向)所占有的标度数,乘以垂直输入灵敏度开关所在档位的V/div数(或水平方向t/div),得出的积便是测量结果。Y轴使用10:1衰减探头的话还需再乘10。 例如图2中测电压峰—峰值时,V/div档用0〃1V/div,输入端用了10 : l 衰减探头,则Vp-p=0〃1V/div×3〃6div×10=3〃6V,t/div档为2ms/div,则波形的周期:T=2ms/div×4div=8ms。 使用前的准备 示波器用于旋钮与开关比较多,初次使用往往会感到无从着手。初学者可按表2方式进行调节。表2位置对示波器久藏复用或会使用者也适用。

使用前的校准 示波器的测试精度与电源电压有关,当电网电压偏离时,会产生较大的测量误差〃因此在使用前必须对垂直和水平系统进行校准。校准方法步骤如下: 1〃接通电源,指示灯有红光显示,稍等片刻,逆时针调节辉度旋钮,并适当调准聚焦,屏幕上就显示出不同步的校准信号方波。 2〃将触发电平调离“自动”位置,逆时针方向旋转旋钮使方波波形同步为止。并适当调节水平移位(11)和垂直移位(5)。 3〃分别调节垂直输入部分增益校准旋钮(10)和水平扫描部分的扫描校准旋钮(14),使屏幕显示的标准方波的垂直幅度为5div,水平宽度为10div,如图3所示,ST一16示波器便可正常工作了。 示波器演示和测量举例 一,用ST一16示波器演示半波整流工作原理: 首先将垂直输入灵敏度选择开关(以下简写V/div)拨到每格0〃5V档,扫描时间转换开关(s/div)拨至每格5ms档,输入耦合开关拨至AC档,将输入探头的两端与电源变压器次级相接,见图4,这时屏幕显示如图5(a)所示的交流电压波形。 如果将探头移到二极管的负端处,这时屏幕上显示图5(b)所示的半波脉冲电压波形〃接上容量较大的电解电容器C进行滤波,调节一下触发电平旋钮(15),在示波器屏幕上可看到较为平稳的直流电压波形,见图5(c)。电容C的容量越大,脉冲成分越小,电压越平稳。

各种变频器操作方法

变频器操作简明手册 (第二版) 沈阳第一机床厂 沈阳机床集团

变频器简明手册第二版 目录 目录 (1) 一、富士变频器 (2) 1、富士变频器的操作: (2) 2、富士变频器设定: (2) 二、安川变频器 (4) 1、安川变频器的操作: (4) 2、安川变频器的设定 (11) 三、日立变频器 (12) 1、日立变频器的操作 (12) 2、日立变频器的设定 (12) 四、艾默生变频器 (14) 1、艾默生变频器的操作 (14) 2、艾默生变频器的设定: (14) 五、Vacon变频器 (16) 1、Vacon变频器的操作 (16) 2、Vacon变频器的设定 (16) 六、汇川变频器 (18) 1、汇川变频器的设定: (18) 沈阳第一机床厂 1

第二版 变频器简明手册 沈阳第一机床厂 2 一、富士变频器 1、富士变频器的操作: 2、富士变频器设定: 首先,按PRG 键显示菜单——按FUNC 键显示菜单明细——按∧ ,∨键可移动游标选择项目——按FUNC 键显示相应的内容——输入数据,用SHIFT 》键任意选择要改变数据的位——按FUNC 键将它存入存贮器——按RESET 和PRG 键可返回到原来的状态。 自学习时参数的设置步骤与上述相同,将参数F02设为0即可,然后按FWD 或RWD 键——机床主轴自动运转至停止后按STOP 键——再将参数F02设为1即完成变频器的运行。 其中各项参数设置如下: F00=0 F01=1(频率设定)

变频器简明手册第二版F02=1(自学习=0) F03=155(最高频率)(90:6140V) F04=33或50(基本频率) F05=380(额定电压) F06=380(最高电压) F05=380(额定电压) F10=1(热继电器1) F11=11.6或15.6(OL设定值) F13=2 F15=160(上限频率) F16=0(下限频率) F23=0.5(起动频率) E20=9(零速信号) P01=4(极数) P02=5.5或7.5(容量) P03=11.6或15.6(额定电流) P04=2(自学习时设2) E01=9(外部故障信号连接时设) E02=8(外部故障信号连接时设) 沈阳第一机床厂 3

日立变频器操作说明 SJ

SJ300型日立变频器操作说明该变频器采用“标准数字操作器OPE--S”,内部参数我厂已经设定,出厂时设定为“就地”操作,但只需简单调试就能实现“就地/集控”的操作转换。 一.就地操作 按“功能键”显示“d001”,按“向下键”直至显示“A- - -”, 按“功能键”显示“A001”,再按“功能键”显示“01”,按“向上键”显示“02”频率由操作器设定,按“存储键”确认。 按“向上键”显示“A002”,按“功能键”显示“01”,再按“向上键”显示“02”运行指令由操作器控制,按“存储键”运行键指示灯亮。 输出频率由F001设定,出厂时设定为50Hz。 按“功能键”显示“A- - -”, 按“向上键”直至显示“d001”输出频率监视,再按“功能键”显示“”即为输出频率,“就地操作”设定完毕。 按“运行键”电动机运行,按“停止/重置键”电动机停止。 二.集控操作 按“功能键”显示“d001”,按“向下键”直至显示“A- - -”, 按“功能键”显示“A001”,再按“功能键”显示“02”,按“向下键”显示“01”频率设定由控制端子操作,按“存储键”存储参数。 按“向上键”显示“A002”,按“功能键”显示“02”,再按“向下键”显示“01”运行指令由控制端子操作,按“存储键”确认。 4-20mA控制频率时设定:A101=0、A102=50、A103=20、A104=100。 按“功能键”显示“A- - -”, 按“向上键”直至显示“d001”输出频率监视,

再按“功能键”显示“”即为输出频率,现在“频率”的高低由DCS系统4-20mA 信号控制,“集控操作”设定完毕。 合上Q3(控制柜内C45单极空气开关)变频器即为“集控”运行,这时电动机的“起动/停止”及“转速”均由DCS系统控制。 *说明:电机正反转以集控为准,就地控制的转向可通过F004设定,“00”为正转;“01”为反转。采用默认值时为正转。 靖江市合金钢机械厂 2004年5月8日

日立变频器操作说明(SJ300)

SJ300型日立变频器操作说明 该变频器采用“标准数字操作器OPE--S”,内部参数我厂已经设定,出厂时设定为“就地”操作,但只需简单调试就能实现“就地/集控”的操作转换。 一.就地操作 按“功能键”显示“d001”,按“向下键”直至显示“A- - -”, 按“功能键”显示“A001”,再按“功能键”显示“01”,按“向上键”显示“02”频率由操作器设定,按“存储键”确认。 按“向上键”显示“A002”,按“功能键”显示“01”,再按“向上键”显示“02”运行指令由操作器控制,按“存储键”运行键指示灯亮。 输出频率由F001设定,出厂时设定为50Hz。 按“功能键”显示“A- - -”, 按“向上键”直至显示“d001”输出频率监视,再按“功能键”显示“00.0”即为输出频率,“就地操作”设定完毕。 按“运行键”电动机运行,按“停止/重置键”电动机停止。 二.集控操作 按“功能键”显示“d001”,按“向下键”直至显示“A- - -”, 按“功能键”显示“A001”,再按“功能键”显示“02”,按“向下键”显示“01”频率设定由控制端子操作,按“存储键”存储参数。 按“向上键”显示“A002”,按“功能键”显示“02”,再按“向下键”显示“01”运行指令由控制端子操作,按“存储键”确认。 4-20mA控制频率时设定:A101=0、A102=50、A103=20、A104=100。 按“功能键”显示“A- - -”, 按“向上键”直至显示“d001”输出频率监视,再按“功能键”显示“00.0”即为输出频率,现在“频率”的高低由DCS系统4-20mA信号控制,“集控操作”设定完毕。 合上Q3(控制柜内C45单极空气开关)变频器即为“集控”运行,这时电动机的“起动/停止”及“转速”均由DCS系统控制。 *说明:电机正反转以集控为准,就地控制的转向可通过F004设定,“00”为正转;“01”为反转。采用默认值时为正转。 靖江市合金钢机械厂 2004年5月8日

日立变频器操作说明SJ

日立变频器操作说明 S J 公司标准化编码 [QQX96QT-XQQB89Q8-NQQJ6Q8-MQM9N]

SJ300型日立变频器操作说明 该变频器采用“标准数字操作器OPE--S”,内部参数我厂已经设定,出厂时设定为“就地”操作,但只需简单调试就能实现“就地/集控”的操作转换。 一.就地操作 按“功能键”显示“d001”,按“向下键”直至显示“A- - -”, 按“功能键”显示“A001”,再按“功能键”显示“01”,按“向上键”显示“02”频率由操作器设定,按“存储键”确认。 按“向上键”显示“A002”,按“功能键”显示“01”,再按“向上键”显示“02”运行指令由操作器控制,按“存储键”运行键指示灯亮。 输出频率由F001设定,出厂时设定为50Hz。 按“功能键”显示“A- - -”, 按“向上键”直至显示“d001”输出频率监视,再按“功能键”显示“”即为输出频率,“就地操作”设定完毕。 按“运行键”电动机运行,按“停止/重置键”电动机停止。 二.集控操作 按“功能键”显示“d001”,按“向下键”直至显示“A- - -”, 按“功能键”显示“A001”,再按“功能键”显示“02”,按“向下键”显示“01”频率设定由控制端子操作,按“存储键”存储参数。 按“向上键”显示“A002”,按“功能键”显示“02”,再按“向下键”显示“01”运行指令由控制端子操作,按“存储键”确认。 4-20mA控制频率时设定:A101=0、A102=50、A103=20、A104=100。 按“功能键”显示“A- - -”, 按“向上键”直至显示“d001”输出频率监视,再按“功能键”显示“”即为输出频率,现在“频率”的高低由DCS系统4-20mA信号控制,“集控操作”设定完毕。 合上Q3(控制柜内C45单极空气开关)变频器即为“集控”运行,这时电动机的“起动/停止”及“转速”均由DCS系统控制。 *说明:电机正反转以集控为准,就地控制的转向可通过F004设定,“00”为正转;“01”为反转。采用默认值时为正转。

通用变频器调试步骤和参数设置

通用变频器调试步骤和参数设置快速调试 当选择P0010=1(快速调试)时,P0003(用户访问级)用来选择要访问的参数。这一参数也可以用来选择由用户定义的进行快速调试的参数表。在快速调试的所有步骤都已完成以后,应设定P3900=1,以便进行必要的电动机数据的计算,并将其它所有的参数(不包括P0010=1)恢复到它们的缺省设置值。

一、快速调试步骤和参数设置

二、功能调试 1、开关量输入功能 2、开关量输出功能 可以将变频器当前的状态以开关量的形式用继电器输出,通过输出继电器的状态来监控变频器的内部状 的每一位更改。 3、模拟量输入功能

1电压信号2~10V作为频率给定,需要设置: 以模拟量通道2电流信号4~20mA作为频率给定,需要设置: 注意:对于电流输入,必须将相应通道的拨码开关拨至ON的位置。 4、模拟量输出功能 MM440变频器有两路模拟量输出,相关参数以in000和in001区分,出厂值为0~20mA输出,可以标定为4~20mA输出(P0778=4),如果需要电压信号可以在相应端子并联一支500Ω电阻。需要输出的物理量可以 5、加减速时间 加速、减速时间也称作斜坡时间,分别指电机从静止状态加速到最高频率所需要的时间,和从最高频率

设置过小可能导致变频器过电流。P1121设置过小可能导致变频器过电压。 6、频率限制 多段速功能,也称作固定频率,就是设置参数P1000=3的条件下,用开关量端子选择固定频率的组合,实现电机多段速度运行。可通过如下三种方法实现: 1)直接选择(P0701~ P0706 = 15) 在这种操作方式下,数字量输入既选择固定频率(见上表),又具备起动功能。 3)二进制编码选择+ON命令(P0701~P0704 = 17)

通用示波器使用说明书新

通用示波器使用说明书 在家电维修的过程中使用示波器已十分普遍。通过示波器可以直观地观察被测电路的波形,包括形状、幅度、频率(周期)、相位,还可以对两个波形进行比较,从而迅速、准确地找到故障原因。正确、熟练地使用示波器,是初学维修人员的一项基本功。 虽然示波器的牌号、型号、品种繁多,但其基本组成和功能却大同小异,本文介绍通用示波器的使用方法。 一、面板介绍 1.亮度和聚焦旋钮 亮度调节旋钮用于调节光迹的亮度(有些示波器称为"辉度"),使用时应使亮度适当,若过亮,容易损坏示波管。聚焦调节旋钮用于调节光迹的聚焦(粗细)程度,使用时以图形清晰为佳。 2.信号输入通道 常用示波器多为双踪示波器,有两个输入通道,分别为通道1(CH1)和通道2(CH2),可分别接上示波器探头,再将示波器外壳接地,探针插至待测部位进行测量。 3.通道选择键(垂直方式选择) 常用示波器有五个通道选择键: (1)CH1:通道1单独显示; (2)CH2:通道2单独显示; (3)ALT:两通道交替显示; (4)CHOP:两通道断续显示,用于扫描速度较慢时双踪显示; (5)ADD:两通道的信号叠加。维修中以选择通道1或通道2为多。 4.垂直灵敏度调节旋钮 调节垂直偏转灵敏度,应根据输入信号的幅度调节旋钮的位置,将该旋钮指示的数值(如0.5V/div,表示垂直方向每格幅度为0.5V)乘以被测信号在屏幕垂直方向所占格数,即得出该被测信号的幅度。 5.垂直移动调节旋钮 用于调节被测信号光迹在屏幕垂直方向的位置。 6.水平扫描调节旋钮 调节水平速度,应根据输入信号的频率调节旋钮的位置,将该旋钮指示数值(如0.5ms/div,表示水平方向每格时间为0.5ms),乘以被测信号一个周期占有格数,即得出该信号的周期,也可以换算成频率。 7.水平位置调节旋钮 用于调节被测信号光迹在屏幕水平方向的位置。 8.触发方式选择 示波器通常有四种触发方式: (1)常态(NORM):无信号时,屏幕上无显示;有信号时,与电平控制配合显示稳定波形; (2)自动(AUTO):无信号时,屏幕上显示光迹;有信号时与电平控制配合显示稳定的波形; (3)电视场(TV):用于显示电视场信号; (4)峰值自动(P-PAUTO):无信号时,屏幕上显示光迹;有信号时,无需调节电

变频器参数基本设置

变频器参数基本设置 变频器应用领域涉及到钢铁行业,化工行业,汽车行业,机床行业,电机机械行业,食品行业,造纸行业,水泥行业,矿业行业,石油行业,工厂建筑等,它促进企业实现了自动化,节约了能源,提高了产品质量和合格率以及生产率,延长了设备使用寿命。通过变频器的功能参数的设置调试,就可以实现相应的功能,一般都有数十甚至上百个参数供用户选择,在实际应用中,没必要对每一参数都进行设置和调试,多数只要采用出厂设定值即可。但有些参数由于和实际使用情况有很大关系,且有的还相互关联,因此要根据实际进行参数的设定和调试。变频器调试的好坏决定了变频器运行的稳定性、应用效果以及使用寿命等,最终关系到企业经济效益的大小,调好了可能大大节约费用,调不好可能损失惨重。以下是作者在普传变频器使用中的经验总结,希望能供其他用户参考,使变频器能更好地推广使用,为企业带来更大的经济效益。 1 变频器调试的步骤 变频器能否成功地应用到各种负载中,且长期稳定地运行,现场调试很关键,必须按照下述相应的步骤进行。 1.1 变频器的空载通电检验 1)将变频器的电源输入端子经过漏电保护开关接到电源上。 2)将变频器的接地端子接地。 3)确认变频器铭牌上的电压、频率等级与电网的是否相吻合,无误后送电。 4)主接触器吸合,风扇运转,用万用表AC 挡测试输入电源电压是否在标准规范内。5)熟悉变频器的操作键盘键, 以普传科技变频器为例: FWD为正向运行键,令驱动器正向运行; REV为反向运行键,令驱动器反向运行; ESC/DISPL为退出/显示键,退出功能项的数据更改,故障状态退出,退出子菜单或由

功能项菜单进入状态显示菜单; STOP/RESET 为停止复位键,令驱动器停止运行,异常复位,故障确认; PRG为参数设定/移位键; SET 为参数设定键,数值修改完毕保存,监视状态下改变监视对象; ▲▼为参数变更/加减键,设定值及参数变更使用,监视状态下改变给定频率; JOG为寸动运行键,按下寸动运行,松开停止运行,不同变频器操作键的定义基本相同。6)变频器运行到50 Hz,测试变频器U V W三相输出电压是否平衡。 7)断电完全没显示后,接上电机线。 1.2 变频器带电机空载运行 1)设置电机的基本额定参数,要综合考虑变频器的工作电流。 2)设定变频器的最大输出频率、基频、设置转矩特性。v/f类型的选择包括最高频率、基本频率和转矩类型等项目。最高频率是变频器—电动机系统可以运行的最高频率,由于变频器自身的最高频率可能较高,当电动机容许的最高频率低于变频器的最高频率时,应按电动机及其负载的要求进行设定。基本频率是变频器对电动机进行恒功率控制和恒转矩控制的分界线,应按电动机的额定电压进行设定。转矩类型指负载是恒转矩负载还是变转矩负载。用户根据变频器使用说明书中的v/f类型图和负载特点,选择其中的一种类型。通用变频器均备有多条v/f曲线供用户选择,用户在使用时应根据负载的性质选择合适的v/f 曲线。为了改善变频器启动时的低速性能,使电机输出的转矩能满足生产负载启动的要求,要调整启动转矩。在异步电机变频调速系统中,转矩的控制较复杂。在低频段,由于电阻、漏电抗的影响不容忽略,若仍保持v/f为常数,则磁通将减小,进而减小了电机的输出转矩。为此,在低频段要对电压进行适当补偿以提升转矩。一般变频器均由用户进行人工设定补偿。普传变频器则为用户提供两种选择,即42种v/f提升方式,自动转矩提升。

FRD变频器基本参数设置

导入新课: 变压器变频器的发展及应用范围 变频技术诞生背景是交流电机无级调速的广泛需求。传统的直流调速技术因体积大故障率高而应用受限。 20世纪60年代以后,电力电子器件普遍应用了晶闸管及其升级产品。但其调速性能远远无法满足需要。 20世纪70年代开始,脉宽调制变压变频(PWM-VVVF)调速的研究得到突破,20世纪80年代以后微处理器技术的完善使得各种优化算法得以容易的实现。 20世纪80年代中后期,美、日、德、英等发达国家的VVVF变频器技术实用化,商品投入市场,得到了广泛应用。步入21世纪后,国产变频器逐步崛起,现已逐渐抢占高端市场。 讲授新课: 课题一:变频器功能参数设置与操作 一、教学内容 1、变频器的概念:是一种将固定频率的交流电变换成频率、电压连续可调的交流电,以供给电动机运转的电源装置。 2、变频器分类: (1)交-交变频器 它是将频率固定的交流电源直接变换成频率连续可调的交流电源,其主要优点是没有中间环节,变换效率高。但其连续可调的频率范围较窄,故主要用于容量较大的低速拖动系统中。又称直接式变频器。 (2)交-直-交变频器 先将频率固定的交流电整流后变成直流,再经过逆变电路,把直流电逆变成频率连续可调的三相交流电,又称为间接型变频器。由于把直流电逆变成交流电较易控制,

因此在频率的调节范围,以及变频后电动机特性的改善等方面,都具有明显的优势,目前使用最多的变频器均属于交-直-交变频器。 二、实训目的和要求 1.熟悉变频器主回路接线; 2.熟悉操作面板显示及各按键操作; 三、三菱FR-D700变频器主回路接线 1. FR-D700变频器主回路接线图如下图 四、变频器的操作面板及使用 1、变频器操作面板如下图 2、操作面板各按键功能 按钮/旋钮 功 能 备 注 PU/EXT 键 切换PU/外部操作模式 PU :PU 操作模式 EXT :外部操作模式 使用外部操作模式(用另外连接的频率设定旋钮和启动信号运行)时,请按下此键,使EXT 显示为点亮状态 RUN 键 运行指令正转 反转用(Pr.40)设定 STOP/RESET 键 进行运行的停止,报警的复位 SET 键 确定各设定 MODE 键 模式切换 切换各设定 设定用旋钮 变更频率设定.参数的设定值 3、操作面板单位表示及运行状态表示见下表 指示灯显示 说明 备 注 设定用旋钮 运行状态 指示区 监视器

日立变频器维修

1引言 日立,在自动化领域相对于西门子,ABB,三菱等一线品牌来说,还是一个相对比较陌生的品牌,其实在工控行业中日立的产品还是经常会看到的,像MICRO EH系列以及较大型的EH-150系列PLC,L系列,SJ系列,J系列变频器,以及交流伺服产品等等,在国内还是有一定的使用量。特别是日立变频器在启动负载较大的输送搅拌装置,需要四象限运行的升降装置,以及纺织化纤行业的卷绕等应用方面都有较多的应用实例。 日立变频器在选型划分上还是比较清晰的,现在市面上正在销售中的变频器包括经济型的L100系列,以及涵盖L100功能的SJ100矢量型变频器,无速度传感器矢量控制的SJ300系列变频器,电梯专用的SJ-300EL系列变频器,风机水泵专用的 L300P系列变频器。现在,市场上的几款日立变频器性能稳定,特别是日立具有专利技术的无速度传感器矢量控制,使得日立变频器在低速时的启动特性相当优越。现在的日立变频器在功能应用上也比较丰富,在同类变频器上经常用到的内置PID 功能,RS-485通讯功能,16段加减速功能,电机并行运行功能,速度升降功能,参数拷贝功能,三线运行功能等在日立变频器的应用中都能一一找到。特别值得一提的是当两台电机在并行运行时同时采用矢量控制,这对于一般变频器是很难做到的,大家都知道,矢量控制时对于电机的参数要求都非常精确。功率,电流,电压,定转子的阻抗都得非常准确,而两台电机并行运行时恰恰很难做到这一点。这可能也是日立变频器的一个亮点。日立变频器在可选件的应用上相对来说不是很多,在通讯选件上主要有Profibus,Device Net等可选。在抗干扰,抑制高低谐波,射频干扰上,日立变频器还是有多种选件可选,交直流电抗器,RFI滤波器,LCR输出正弦滤波器等都为抑制变频器的对外干扰做了很好的保证。 今天有客户送来一个日立变频器,显示缺相报警,为了能够顺利修复这台变频器,我们花时间画下了日立变频器的缺相保护电路如下:

力科示波器使用手册

Digital Oscilloscopes

Wave r unner-2 Qu i c k s t a r t to Signal Vi e w i n g An a l o g Pe r s i s t e n c e ? Press A N A L O G P E R S I S T to access the power of An a l o g Pe r s i s t e n c e.The three-dimensional view shows va r i a tions in a wave f o r m as i n te n s i t y or co l o r -g r aded va r i a t i o n s .Press D I S P L AY to custo m i z e the display. Press Z O O M for a close-up view of signal https://www.360docs.net/doc/bc1089312.html,e the zoo m co n t r ols to magnify and inspe c t the signal,the soft k eys to change the zoom view,l o ck the zoom tra c es with multi-zoo m ,and to auto m a t i c ally scan the wave f o r m . 1 .Co n n e c t your signal.When using a pro b e,Pro B u s ? a u t o m a t i c ally sets the ve r t i c al scale factor and HFP pro b es a u t o m a t i c ally light-up with the tra c e co l o r .2 .Press A U T O S E T U P an d view. 3 .Press “ U n d o ”to reve r t back to a previous setting. Adjust the T I M E / D I V , and SMART Me m o r y a u t o m a t i c ally assure s the maximum re s o l u -tion for each time-base setting. Press a C H A N N E L b u t t o n ,and use the co n t r ol knobs to s e l e c t an d adjust that c h a n n e l ’s Vo l t s /D i v and offset settings.Press tw i c e to tog g l e the channel be t we e n On and O f f . Se l e c ts a pre- or po s t -t r igger https://www.360docs.net/doc/bc1089312.html,e to v i e w the signal eve n t s p r ior to the tri g g e r po i n t. Presets the tri g g e r d e l a y to ze r o. Quick Zoo m Press a C H A N N E L b u t t on to view the menu.

虚拟示波器使用手册

虚拟示波器使用手册 一、软件安装说明 软件安装包括USB数据采集卡驱动程序安装和虚拟示波器软件安装。 1、安装USB数据采集卡驱动程序 本虚拟示波器使用前必须先正确安装USB数据采集卡驱动程序。其安装步骤如下: (1)将USB通信电缆的方形接口插入数据采集卡,USB通信电缆的另一端插入计算机的USB 通信口。计算机查询到新的硬件,启动硬件向导,如图1-1所示,选择“从列表或指定位置安装(高级)”,点击“下一步”: 图1-1硬件向导 (2)进入如图1-2界面,选择“在搜索中包括这个位置”,点击“浏览”,选择USB数据采集卡驱动程序文件,点击“下一步”,开始安装驱动程序: 图1-2选择安装文件

(3)安装完成后,出现如图1-3界面,表明驱动程序安装成功。 图1-3安装完成 如果在使用虚拟示波器过程中,出现数据采集不正确现象,应卸载已经安装的USB数据采集卡驱动程序,将USB通信电缆插入计算机的其他USB通信口,重新安装USB数据采集卡驱动程序。 2、安装虚拟示波器软件 (1)点击文件夹“虚拟示波器软件安装包”,选择“setup.exe”安装程序,进入如图1-4界面: 图1-4软件安装向导

(2)第一步完成后,进入如图1-5界面: 图1-5选择目标路径(3)选择好安装位置后,点击“下一步”,进入如图1-6界面: 图1-6许可协议 (4)选择“我接受该许可协议”,点击“下一步”,进入如图1-7界面:

图1-7准备安装 (5)点击“下一步”,进入如图1-8界面: 图1-8开始安装 (6)程序开始安装,安装完成后进入如图1-9界面,表明程序安装成功。

示波器基本使用方法

示波器基本使用方法文稿归稿存档编号:[KKUY-KKIO69-OTM243-OLUI129-G00I-FDQS58-

示波器基本使用方法 荧光屏 荧光屏是示波管的显示部分。屏上水平方向和垂直方向各有多条刻度线,指示出信号波形的电压和时间之间的关系。水平方向指示时间,垂直方向指示电压。水平方向分为10格,垂直方向分为8格,每格又分为5份。垂直方向标有0%,10%,90%,100%等标志,水平方向标有10%,90%标志,供测直流电平、交流信号幅度、延迟时间等参数使用。根据被测信号在屏幕上占的格数乘以适当的比例常数(V/DIV,TIME/DIV)能得出电压值与时间值。 示波管和电源系统 1.电源(Power) 示波器主电源开关。当此开关按下时,电源指示灯亮,表示电源接通。 2.辉度(Intensity) 旋转此旋钮能改变光点和扫描线的亮度。观察低频信号时可小些,高频信号时大些。一般不应太亮,以保护荧光屏。 3.聚焦(Focus) 聚焦旋钮调节电子束截面大小,将扫描线聚焦成最清晰状态。 4.标尺亮度(Illuminance)

此旋钮调节荧光屏后面的照明灯亮度。正常室内光线下,照明灯暗一些好。室内光线不足的环境中,可适当调亮照明灯。 2.3 垂直偏转因数和水平偏转因数 1.垂直偏转因数选择(VOLTS/DIV)和微调 在单位输入信号作用下,光点在屏幕上偏移的距离称为偏移灵敏度,这一定义对X轴和Y轴都适用。灵敏度的倒数称为偏转因数。垂直灵敏度的单位是为cm/V,cm/mV或者DIV/mV,DIV/V,垂直偏转因数的单位是V/cm,mV/cm或者V/DIV,mV/DIV。实际上因习惯用法和测量电压读数的方便,有时也把偏转因数当灵敏度。 踪示波器中每个通道各有一个垂直偏转因数选择波段开关。一般按1,2,5方式从 5mV/DIV到5V/DIV分为10档。波段开关指示的值代表荧光屏上垂直方向一格的电压值。例如波段开关置于1V/DIV档时,如果屏幕上信号光点移动一格,则代表输入信号电压变化1V。 每个波段开关上往往还有一个小旋钮,微调每档垂直偏转因数。将它沿顺时针方向旋到底,处于“校准”位置,此时垂直偏转因数值与波段开关所指示的值一致。逆时针旋转此旋钮,能够微调垂直偏转因数。垂直偏转因数微调后,会造成与波段开关的指示值不一致,这点应引起注意。许多示波器具有垂直扩展功能,当微调旋钮被拉出时,垂直灵敏度扩大若干倍(偏转因数缩小若干倍)。例如,如果波段开关指示的偏转因数是1V/DIV,采用×5扩展状态时,垂直偏转因数是0.2V/DIV。 在做数字电路实验时,在屏幕上被测信号的垂直移动距离与+5V信号的垂直移动距离之比常被用于判断被测信号的电压值。

日立电梯TD3100变频器参数设定

日立电梯TD3100变频器参数设定 TD3100变频器参数设定 功能键盘面盘显示单位设定值 代码名称 F0.01 语种选择语种选择 1 0 F0.02 操作方式选择操作方式 1 2 F0.03 运行速度数字设定运行速度设定 0.001m/s 0 F0.04 运行方向切换运行方向 1 0 F0.05 电梯额定速度额定速度 0.001m/s 60 90 105 1 1.5 F0.06 最大输出频率最大频率 0.01Hz 50 F0.07 载波频率调节载波频率 0.1kHz 7 F0.08 参数更新参数更新 1 0 F1.00 PG脉冲数选择 PG脉冲数 1 1024 F1.01 电机类型选择电机类型选择 1 0 F1.02 电机功率额定功 率 0.1KW 7.5KW 11KW 15KW 18.5KW F1.03 电机额定电压额定电压 1V 360V F1.04 电机额定电流额定电流 0.1A 27.5 F1.05 电机额定频率额定频率 0.01Hz 50 F1.06 电机额定转速额定转速 1r/min 960 F1.08 电机过载保护方式选择过载保护 1 1 or 2 F1.10 电机自动调谐保护自动调谐保护 1 0 F1.12 定子电阻定子电阻 0.001欧 0.338 0.307 F1.13 定子电感定子电感 0.1mH 85 55.3 F1.14 转子电阻转子电阻 0.001欧 0.367 0.346 F1.15 转子电感转子电感 0.1mH 54.9 55.3 F1.16 互感互感 0.1mH 54.9 52.4 F1.17 空载激磁电流空载激磁电流 0.1A 9 11.7 F2.00 ARS比例增益1 ASR1-P 0 1 F2.01 ARS积分时间1 ASR1-1 0.001s 1 F2.02 ARS比例增益2 ASR2-P 0 2 F2.03 ARS积分时间2 ASR2-1 0.001s 0.5 F3.06 多端速度3 多端速度3 0.001m/s 0.04 F3.07 多端速度4 多端速度4 0.001m/s 0.25 F3.08 多端速度5 多端速度5 0.001m/s 1 F3.09 多端速度6 多端速度6 0.001m/s 1 F3.10 多端速度7 多端速度7 0.001m/s 60 90 105 1 1.5 F5.05 普通开关量输入X6段子功能选择 X6段子功 能 1 8 F5.06 普通开关量输入X7段子功能选择 X7段子功

示波器使用说明

附录Ⅰ ss7802(20M)/ss7804(40M)型示波器简介 ss7802型示波器是日本岩崎公司生产的带有CRT读出功能的20MHZ带宽模拟双踪示波器。该示波器带有CRT读出功能,所以能够方便、准确地进行电压幅度、频率、相位和时间间隔等的测量。示波器面板上的波段开关大多使用电子开关(不是机械开关),从而免除了由于操作不当造成的机械损坏。除了电源开关为自锁式机械开关外,面板上的其他开关均为触点开关,其所处状态均显示于示波器的屏幕上。 1.1.1 ss7802型示波器的主要性能指标 1.Y轴偏转系统 (1)显示方式:显示方式有1通道(CH1)或2通道(CH2)的单踪显示、1通道(CH1)和2通道(CH2)的双踪显示、两通道相加(ADD)的波形显示(这时1,2通道的波形可不显示)。双踪显示有交替(ALT)和断续(CHOP)两种显示模式(在CHOP模式中,转换频率为555KHZ)。 (2)耦合方式:耦合发方式有交流耦合(AC)和直流耦合(DC)两种。 (3)灵敏度:灵敏度范围为2mV/DIV~5V/DIV,按1—2—5步进分11挡,在每一挡内可进行连续调节。 (4)精度:±2%。 (5)频带宽度:直流耦合时频带宽度为0~20MHZ;交流耦合时频带宽度为10HZ~~20HZ。 (6)上升时间:tr≈8.75ns。 (7)输入阻抗:输入电阻为1MΩ,输入电容为25PF。使用仪器配备的探头10挡是输入电阻为10MΩ,输入电容为22PF。 (8)Y轴允许的最大输入电压:±400V。 2. X轴偏转系统 (1)扫描速率:100ns/DIV~500ms/DIV,按1—2—5步进分档,在每一挡内可连续调节。 (2)扫描精度:〈5%。 (3)扫描扩展:10倍。 1.1.2 SS7802型示波器面板各部分的作用及使用方法 SS7802型示波器的前面板如图1-1所示,大体上分为屏幕显示调节、Y轴偏转系统和X轴偏转系统3大部分。 1、屏幕显示调整部分

示波器操作说明

Tektronix THS710A 示波器操作指令 示波器是仪表检修过程中最常用的工具之一。对示波器的正确操作关乎数据采集的有效性和系统、设备的运行安全。 Tektronix THS710A手持式示波器由美国著名通信技术公司泰克(Tektronix)生产。本报告基于现场操作经验,对该示波器的面板按钮、常用功能及其设置方式做一简单介绍,并总结细化实际应用中的操作指令,方面初学者快速上手。 一、面板按钮功能 由上图可以直观地看到,示波器的前面板分为四个主要的区域——菜单区、垂直控制区、水平区控制区和触发区,下面对面板按钮逐一介绍。 1.1、菜单按钮 AQUIRE(采集):设定采集状态。 SAVE/RECALL(保存/再调):保存或再调出设置状态或波形。

MEASURE(测定):执行波形自动测定 DISPLAY(显示):改变波形和显示的外观。 CURSOR(光标):选用示波器的光标。 UTILITY(实用功能):选用各种系统实用功能。 TRIGGER(触发):选用触发功能。 HORIZONTAL(水平):改变波形的水平特性。 VERTICAL(垂直):调整波形的刻度和位置,设定输入参数。 说明: 菜单系统操作步骤: 1、按面板上的按钮,显示所需菜单。 2、按菜单读取钮,选择菜单项目。如出现弹出菜单,继续按读取钮,选择菜单中项目。可能需按Select Page(选择页)钮以显示附加菜单项目。 3、某些菜单项目需要设定参数,此时可以按右侧+/-按钮改变参数值或按TOGGLE恢复预设值。 4、若OK钮出现,按下此钮确认所选项目。 1.2、专用按钮 ON/STBY(开启/等待) METER(万用表):进入万用表状态。 SCOPE(示波器):进入示波器状态。 HARD COPY(硬拷贝):硬拷贝打印初始化。 HOLD(保持):保持或重新开始示波器的采集。 AUTORANGE(自动量程):选择自动量程功能。 CLEARMENU(清除菜单):清除显示出的菜单。 TRIGGER LEVEL(触发电平):调整触发电平。 SET LEVEL TO 50%(中点设定):将触发电平调至示波器波形中点。 HORIZONTAL POSITION(水平位置):调整波形水平位置。 MAG:打开或关闭波形10倍放大功能。 SEC/DIV(秒/刻度):调整水平刻度比例。 VERTICAL POSITION(垂直位置):调整波形显示的垂直位置。 WAVEFORM OFF(波形关闭):消除所选波形的显示。 VOLTS/DIV(电压/刻度):调整波形垂直刻度比例。 CH1,CH2,MATH,REF A,REF B(通道1、通道2、数学运算、基准A、基准B) 二、功能及参数设置 2.1、示波器显示界面 按下SCOPE按钮进入示波器状态,然后按AUTORANGE,自动设定横、纵坐标和触发器以建立可用显示。 状态显示分为四个部分:状态栏、网格区、波形读数显示行、测定读数区。 状态栏位于显示屏的顶部,用以显示采集和触发状态信息。其中触发状态信息包括Auto (自动触发)、Trig?(待触发)、PrTrig(采集新的预触发数据)。 网格区显示波形。 底部波形读数栏区显示各通道波形时基和触发信息。 右侧测定读数区包括光标读数和测定读数。

变频器主要设置参数

变频器主要设置参数 1、运行方式:主要是带编码器和不带编码器(编码器比较精确一些),其中分别还有是矢量控制还是V/F控制(力矩大时最好用矢量控制比较稳定) 2、控制方式:有变频器自带的那个操作面板控制正反转还是用端子控制正反转这个是必须要设定的参数 3、频率来源设定:是面板直接给还是模拟量给 4、再有是停车方式:自由停车一般用于带抱闸的电机,减速停车相反 5、其他还需要设电机的一些参数进行自学习,保证电机的最佳状态。有些变频器再最开始需要设定某参数,使所有参数都允许改写和高级菜单功能 变频器功能参数很多,一般都有数十甚至上百个参数供用户选择。实际应用中,没必要对每一参数都进行设置和调试,多数只要采用出厂设定值即可。但有些参数由于和实际使用情况有很大关系,且有的还相互关联,因此要根据实际进行设定和调试。 因各类型变频器功能有差异,而相同功能参数的名称也不一致,为叙述方便,本文以富士变频器基本参数名称为例。由于基本参数是各类型变频器几乎都有的,完全可以做到触类旁通。 一、加减速时间 加速时间就是输出频率从0上升到最大频率所需时间,减速时间是指从最大频率下降到0所需时间。通常用频率设定信号上升、下降来确定加减速时间。在电动机加速时须限制频率设定的上升率以防止过电流,减速时则限制下降率以防止过电压。 加速时间设定要求:将加速电流限制在变频器过电流容量以下,不使过流失速而引起变频器跳闸;减速时间设定要点是:防止平滑电路电压过大,不使再生过压失速而使变频器跳闸。加减速时间可根据负载计算出来,但在调试中常采取按负载和经验先设定较长加减速时

间,通过起、停电动机观察有无过电流、过电压报警;然后将加减速设定时间逐渐缩短,以运转中不发生报警为原则,重复操作几次,便可确定出最佳加减速时间。 二、转矩提升 转矩提升又叫转矩补偿,是为补偿因电动机定子绕组电阻所引起的低速时转矩降低,而把低频率范围f/V增大的方法。设定为自动时,可使加速时的电压自动提升以补偿起动转矩,使电动机加速顺利进行。如采用手动补偿时,根据负载特性,尤其是负载的起动特性,通过试验可选出较佳曲线。对于变转矩负载,如选择不当会出现低速时的输出电压过高,而浪费电能的现象,甚至还会出现电动机带负载起动时电流大,而转速上不去的现象。 三、电子热过载保护 本功能为保护电动机过热而设置,它是变频器内CPU根据运转电流值和频率计算出电动机的温升,从而进行过热保护。本功能只适用于“一拖一”场合,而在“一拖多”时,则应在各台电动机上加装热继电器。 电子热保护设定值(%)=[电动机额定电流(A)/变频器额定输出电流(A)>×100%。 四、频率限制 即变频器输出频率的上、下限幅值。频率限制是为防止误操作或外接频率设定信号源出故障,而引起输出频率的过高或过低,以防损坏设备的一种保护功能。在应用中按实际情况设定即可。此功能还可作限速使用,如有的皮带输送机,由于输送物料不太多,为减少机械和皮带的磨损,可采用变频器驱动,并将变频器上限频率设定为某一频率值,这样就可使皮带输送机运行在一个固定、较低的工作速度上。 五偏置频率 有的又叫偏差频率或频率偏差设定。其用途是当频率由外部模拟信号(电压或电流)进行设定时,可用此功能调整频率设定信号最低时输出频率的高低,如图1。有的变频器当频率设定信号为0%时,偏差值可作用在0~fmax范围内,有的变频器(如明电舍、三垦)还可对偏置极性进行设定。如在调试中当频率设定信号为0%时,变频器输出频率不为0Hz,而为xHz,则此时将偏置频率设定为负的xHz即可使变频器输出频率为0Hz。 六频率设定信号增益

示波器详细使用说明

示波器的工作原理 时间:2009-05-13 13:42:16 来源:作者: 在数字电路实验中,需要使用若干仪器、仪表观察实验现象和结果。常用的电子测量仪器有万用表、逻辑笔、普通示波器、存储示波器、逻辑分析仪等。万用表和逻辑笔使用方法比较简单,而逻辑分析仪和存储示波器目前在数字电路教学实验中应用还不十分普遍。示波器是一种使用非常广泛,且使用相对复杂的仪器。本章从使用的角度介绍一下示波器的原理和使用方法。 1 示波器工作原理 示波器是利用电子示波管的特性,将人眼无法直接观测的交变电信号转换成图像,显示在荧光屏上以便测量的电子测量仪器。它是观察数字电路实验现象、分析实验中的问题、测量实验结果必不可少的重要仪器。示波器由示波管和电源系统、同步系统、X轴偏转系统、Y轴偏转系统、延迟扫描系统、标准信号源组成。 1.1 示波管 阴极射线管(CRT)简称示波管,是示波器的核心。它将电信号转换为光信号。正如图1所示,电子枪、偏转系统和荧光屏三部分密封在一个真空玻璃壳内,构成了一个完整的示波管。 图1 示波管的内部结构和供电图示 1.荧光屏 现在的示波管屏面通常是矩形平面,内表面沉积一层磷光材料构成荧光膜。在荧光膜上常又增加一层蒸发铝膜。高速电子穿过铝膜,撞击荧光粉而发光形成亮点。铝膜具有内反射作用,有利于提高亮点的辉度。铝膜还有散热等其他作用。 当电子停止轰击后,亮点不能立即消失而要保留一段时间。亮点辉度下降到原始值的10%所经过的时间叫做“余辉时间”。余辉时间短于10μs为极短余辉,10μs—1ms为短余辉,1ms—0.1s为中余辉,0.1s-1s为长余辉,大于1s为极长余辉。一般的示波器配备中余辉示波管,高频示波器选用短余辉,低频示波器选用长余辉。 由于所用磷光材料不同,荧光屏上能发出不同颜色的光。一般示波器多采用发绿光的示

相关文档
最新文档