软土地区PHC桩单桩水平承载力的计算分析与试验

软土地区PHC桩单桩水平承载力的计算分析与试验
软土地区PHC桩单桩水平承载力的计算分析与试验

软土地区PHC桩单桩水平承载力的计算分析与试验

摘要:本文分别采用m值法的幂级数解(即规范公式和表格)和杆件有限元方法对某工程项目的水平受荷PHC桩的内力和位移进行分析计算,并与试桩成果进行了对比。文章对基于SAP2000通用有限元程序的m值法求解水平受荷桩的内力和变形进行了验证,并对该方法的扩展应用提出了展望。同时,也指出在沿海软土地区PHC桩的水平承载力相对于其竖向承载力比例很低,在设计中应加以重视。

关键词:PHC桩,软土,单桩水平承载力,水平受荷桩,m值法,土弹簧,桩-土共同作用模型

Abstract: This article presents two methods of analyzing deformation and internal forces of laterally loaded single pile. These methods are based on m-method, the first one is analytic solution (equations and tables from design codes), and the other one is applying FEM program. Solutions are also compared with the on-site test results. The Pile-Soil FEM modeling using SAP2000 program based on the m-method is verified and further application is briefly described. The author points out that the capacity of laterally loaded pile is very load in the soft soil site and designer should pay attention to this fact.

Key words: PHC Pile, soft soil, lateral bearing capacity, laterally loaded single pile,m-method, soil spring, pile-soil interaction modeling

前言

桩水平承载力和位移的影响因素包括桩身截面抗弯刚度、材料强度、桩侧土质条件、桩的入土深度、桩顶约束条件等等。在珠江三角洲地区普遍存在着含水量大、压缩性高、承载力低的深厚淤泥或淤泥质土,同时也广泛分布有松散砂土等工程性状差的软弱土层。而该地区广泛采用的高强预应力混凝土管桩(PHC)桩直径多在400mm~600mm之间,桩身的抗弯刚度和抗弯承载力相对较低。相对其竖向承载力来说,PHC桩的单桩水平承载力低,在某些情况下桩基础的水平承载力会成为桩基设计的决定性因素。

桩基础作业(承载力计算)-附答案

1.某灌注桩,桩径0.8d m =,桩长20l m =。从桩顶往下土层分布为: 0~2m 填土,30sik a q kP =;2~12m 淤泥,15sik a q kP =;12~14m 黏土,50sik a q kP =;14m 以下为密实粗砂层,80sik a q kP =,2600pk a q kP =,该层厚度大,桩未穿透。试计算单桩竖向极限承载力标准值。 【解】 uk sk pk sik i pk p Q Q Q u q l q A =+=+∑ ()20.8302151050280426000.84 1583.41306.92890.3uk sk pk Q Q Q kN π π=+=???+?+?+?+??=+= 2.某钻孔灌注桩,桩径 1.0d m =,扩底直径 1.4D m =,扩底高度1.0m ,桩长 12.5l m =,桩端入中砂层持力层0.8m 。土层分布: 0~6m 黏土,40sik a q kP =;6~10.7m 粉土,44sik a q kP =; 10.7m 以下为中砂层,55sik a q kP =,1500pk a q kP =。试计算单桩竖向极限承载力标准值。 【解】 1.00.8d m m =>,属大直径桩。 大直径桩单桩极限承载力标准值的计算公式为: p pk p i sik si pk sk uk A q l q u Q Q Q ψψ+=+=∑ (扩底桩斜面及变截面以上d 2长度范围不计侧阻力) 大直径桩侧阻、端阻尺寸效应系数为: 桩侧黏性土和粉土:() 1/5 1/5(0.8/)0.81.00.956si d ψ=== 桩侧砂土和碎石类土:()1/3 1/3(0.8/)0.81.00.928si d ψ=== 桩底为砂土:() 1/3 1/3(0.8/)0.81.40.830p D ψ=== ()2 1.00.9564060.956440.831500 1.410581505253.3564 uk Q kN ππ =????+??+???=+= 3.某工程采用泥浆护壁钻孔灌注桩,桩径1.2m ,桩端进入中等风化岩1.0m ,中等风化岩岩体较完整,饱和单轴抗压强度标准值为41.5a MP ,桩顶以下土层参数

桩基承载力计算公式(老规范)

一、嵌岩桩单桩轴向受压容许承载力计算公式 采用嵌岩的钻(挖)孔桩基础,基础入持力层1~3倍桩径,但不宜小于1.00m,其单桩轴向受压容许承载力[P]建议按《公路桥涵地基与基础设计规范》JTJ024—85第4.3.4条推荐的公式计算。 公式为:[P]=(c1A+c2Uh)Ra 公式中,[P]—单桩轴向受压容许承载力(KN); Ra—天然湿度的岩石单轴极限抗压强度(KPa),按表4.2 查取,粉砂质泥岩:Ra =14460KPa;砂岩:Ra =21200KPa h—桩嵌入持力层深度(m); U—桩嵌入持力层的横截面周长(m); A—桩底横截面面积(m2); c1、c2—根据清孔情况、岩石破碎程度等因素而定的系数。挖孔桩取c1=0.5,c2=0.04;钻孔桩取c1=0.4,c2=0.03。 二、钻(挖)孔桩单桩轴向受压容许承载力计算公式 采用钻(挖)孔桩基础,其单桩轴向受压容许承载力[P]建议按《公路桥涵地基与基础设计规范》JTJ024—85第4.3.2条推荐的公式计算。 公式为:[]()R p A Ul Pσ τ+ = 2 1 公式中,[P] —单桩轴向受压容许承载力(KN); U —桩的周长(m); l—桩在局部冲刷线以下的有效长度(m); A —桩底横截面面积(m2),用设计直径(取1.2m)计算;

p τ— 桩壁土的平均极限摩阻力(kPa),可按下式计算: ∑==n i i i p l l 11ττ n — 土层的层数; i l — 承台底面或局部冲刷线以下个土层的厚度(m); i τ— 与i l 对应各土层与桩壁的极限摩阻力(kPa),按表 3.1查取; R σ— 桩尖处土的极限承载力(kPa),可按下式计算: {[]()}322200-+=h k m R γσλσ []0σ— 桩尖处土的容许承载力(kPa),按表3.1查取; h — 桩尖的埋置深度(m); 2k — 地面土容许承载力随深度的修正系数,据规范表 2.1.4取为0.0; 2γ— 桩尖以上土的容重(kN/m 3); λ— 修正系数,据规范表4.3.2-2,取为0.65; 0m — 清底系数,据规范表4.3.2-3,钻孔灌注桩取为 0.80,人工挖孔桩取为1.00。

如何计算单桩承载力特征值

(一)单桩承载力特征值是什么? 1、单位桩体所能承受的极限荷载力也就是最大静载试验压力除以安 全系数2.0得出的标准值 2、指单桩在外荷载作用下,不丧失稳定,不产生过大变形所能承受的最大荷载特征值。符号为Ra 3、由荷载试验测定的单桩压力变形曲线线性变形段内规定的变形所对应的压力值,其最大值为比例界限值 (二)最近在搞水泥土搅拌桩(桩径500mm),设计给的复合地基承 载力特征值是250kp,现在要计算单桩承载力特征值,应该怎么计算?《建筑地基处理技术规范》JGJ79-2002上有公式计算,但是有好多公式中的符号不知道是什么意思,求高手解答。另外,能不能根据复合地基承载力的特征值推算出单桩的承载力特征值? 楼主的原意是不是这样:设计给的水泥搅拌桩复合地基承载力特征值是250kp,这是设计要求,桩径500mm,其它还不太清楚,在此条件下,可以按下述步骤依据3楼公式反算: 首先参数确定: fspk─复合地基承载力特征值250kPa,设计要求值; Ap─搅拌桩截面积(m2),500mm桩径为0.19625m^2; fsk─桩间土承载力特征值(kPa),可查勘察报告确定,一般水泥搅拌桩加固作复合地基的地层承载力都不高,假设查勘察报告应取100kPa; m─面积置换率,由计划的加固桩桩间距确定,我们暂时假设按

3d桩间距布桩,则置换率为0.19625/(1.5*1.5)=0.0872; β─桩间土承载力折减系数,一般取0.7。 按3楼搅拌桩复合地基承载力特征值一般可按下式估算: fspk=m(Ra/Ap)+β(1-m)fsk 则要求的单桩竖向承载力特征值: Ra=Ap(fspk-β(1-m)fsk)/m =0.19625(250-0.7(1-0.0872)100)/0.0872=418.8(kN)就是说按3d桩间距均布500mm搅拌桩,要达到设计要求的 250kPa复合地基承载力需要,当地桩间土承载力特征值为100kPa时,要求的搅拌桩单桩竖向承载力特征值为420kN,按此方案,就可依据 勘察报告提供的搅拌桩桩基参数,进一步确定单颗搅拌桩应该多长,能够达到420kN。 上述步骤才是正确的确定满足设计需要的单桩竖向承载力特征值的正确方法。

单桩竖向承载力特征值计算

单桩竖向承载力特征值计算 根据《简明施工计算手册(第三版)》单桩承载力计算:(p320—p326) 1.一般直径竖向承载力特征值,可按下式计算: p pa i sia p pk sk a A q l q Q Q R +=+=∑μ 其中,sk Q :单桩总侧阻力特征值; pk Q :单桩总端阻力特征值; p μ:桩身周长; sia q :桩第i 层土的侧阻力特征值——(查表5-15) (p321) 修正系数0.8:1q =36K ,2q =20KN ,3q =116kN ; i l ——土层厚度; p A ——桩端面积 pa q ——极限端阻力特征值——查表(5-16) (p322),得8400。 一、圆桩:(R=15) 0.943×(2.5×36×0.8+2.5×0.8×20+1×2×116)+8400×A =808.8kN 二、方桩:(A=0.3×0.3) 4×0.3×(2.5×36×0.8+25×0.8×20+1×2×116)+8400×A =273.6+1029.6=1303.2kN

2.大直径(mm d 800≥)单桩竖向承载力特征值,可按下式计算: p pa P i sia si p pk sk a A q l q Q Q R ’ ψψμ+=+=∑ 其中,sk Q :单桩总侧阻力特征值,这里我们使用端承桩sk Q 为0忽略不计; pk Q :单桩总端阻力特征值; p μ:桩身周长; sia q :桩第i 层土的侧阻力特征值——(查表5-15) (p321); i l ——土层厚度; p A ——桩端面积,p A =N 2 21?? ? ?? pa q ——极限端阻力特征值——查表(5-16) (p322); ‘sia q ——桩侧第i 层土的侧阻力特征值——(查表5-15)(p321); ‘pa q ——桩径为800mm 的端阻力特征值,可采用深层载荷板试验确定,这里我们查表(5-17)取值2500; si ψ、P ψ——大直径桩侧阻、端阻尺寸效应系数,按表(5-18) (p324)取值P ψ端阻尺寸效应系数3 18.0??? ??D 。 对于混凝土护壁的大直径挖孔桩,计算单桩竖向承载力时,其设计桩径取护壁外直径。 挖孔桩:(D=1m ,h=6-7m ) 31 18.0??? ??×2500×∏221??? ??=1822.7kN

钻孔桩单桩承载力特征值计算

钻孔桩单桩承载力特征值计算 一、 按摩擦端承桩计算 已知参数: 根据DBJ15-31-2003中10.2.3条公式a sia i pa p R u q l uq A =+∑计算: 当1000?桩:22211 1.0 3.14 3.14, 1.0 3.140.78544 p u d m A d m ππ==?== =??= ZK1 3.142516.913 4.5330.5500.785=2828kN ZK2 3.14251713 4.6330.5500.785=2795kN a sia i pa p a sia i pa p R u q l uq A R u q l uq A =+=??+?+?+??=+=??+?+?+??∑∑钻孔: (2.3)+1800钻孔: (1.7)+1800当800?桩:22211 0.8 3.14 2.5,0.8 3.140.5044 p u d m A d m ππ==?== =??= ZK1 2.52516.913 4.5330.5500.50=2026kN ZK2 2.5251713 4.6330.5500.50=2000kN a sia i pa p a sia i pa p R u q l uq A R u q l uq A =+=??+?+?+??=+=??+?+?+??∑∑钻孔: (2.3)+1800钻孔: (1.7)+1800二、桩身承载力设计值计算 由DBJ15-31-2003中10.2.7条可知:

2c ,0.70,2511.9/;c c ps c N f A C f N mm φφ≤==其中,砼: 当1000?桩:22211 1.0 3.140.78544 p A d m π= =??= 30.7011.90.785106539c c ps N f A kN φ≤=???= 6539 48431.35 1.35 a N R kN ≤ == 当800?桩:222 110.8 3.140.5044p A d m π==??= 30.7011.90.50104165c c ps N f A kN φ≤=???= 4165 30851.35 1.35 a N R kN ≤ == 三.单桩承载力设计值确定 综上所述: 100025008001800a a R kN R kN φφ==桩,取桩,取

最全面的桩基计算总结

最全面的桩基计算总结 桩基础计算 一.桩基竖向承载力《建筑桩基技术规范》 5.2.2 单桩竖向承载力特征值Ra应按下式确定: Ra=Quk/K 式中 Quk——单桩竖向极限承载力标准值; K——安全系数,取K=2。 5.2.3对于端承型桩基、桩数少于4根的摩擦型柱下独立桩基、或由于地层土性、使用条件等因素不宜考虑承台效应时,基桩竖向承载力特征值应取单桩竖向承载力特征值。5.2.4对于符合下列条件之一的摩擦型桩基,宜考虑承台效应确定其复合基桩的竖向承载力特征值: 1 上部结构整体刚度较好、体型简单的建(构)筑物; 2 对差异沉降适应性较强的排架结构和柔性构筑物; 3 按变刚度调平原则设计的桩基刚度相对弱化区; 4 软土地基的减沉复合疏桩基础。 当承台底为可液化土、湿陷性土、高灵敏度软土、欠固结土、新填土时,沉桩引起超孔隙水压力和土体隆起时,不考虑承台效应,取η=0。

单桩竖向承载力标准值的确定: 方法一:原位测试 1.单桥探头静力触探(仅能测量探头的端阻力,再换算成探头的侧阻力)计算公式见《建筑桩基技术规范》5.3.3 2.双桥探头静力触探(能测量探头的端阻力和侧阻力)计算公式见《建筑桩基技术规 范》5.3.4 方法二:经验参数法 1.根据土的物理指标与承载力参数之间的关系确定单桩承载力标准值《建筑桩基技术规范》5.3.5 2.当确定大直径桩(d>800mm)时,应考虑侧阻、端阻效应系数,参见5. 3.6 钢桩承载力标准值的确定: 1.侧阻、端阻同混凝土桩阻力,需考虑桩端土塞效应系数;参见5.3.7 混凝土空心桩承载力标准值的确定: 1.侧阻、端阻同混凝土桩阻力,需考虑桩端土塞效应系数;参见5.3.8 嵌岩桩桩承载力标准值的确定: 1.桩端置于完整、较完整基岩的嵌岩桩单桩竖向极限承载力,由桩周土总极限侧阻力和嵌岩段总极限阻力组成。 后注浆灌注桩承载力标准值的确定: 1.承载力由后注浆非竖向增强段的总极限侧阻力标准值、后注浆竖向增强段的总极限侧阻力标准值,后注浆总极限端阻力标准值; 特殊条件下的考虑 液化效应: 对于桩身周围有液化土层的低承台桩基,当承台底面上下分别有厚度不小于1.5m、1.0m 的非液化土或非软弱土层时,可将液化土层极限侧阻力乘以土层液化折减系数计算单桩

单桩竖向承载力特征值计算方法

单桩竖向承载力特征值按《建筑桩基技术规范》JGJ94 -2008第5.2.2条公式5.2.2计算: R a=Q uk/K 式中: R a——单桩竖向承载力特征值; Q uk——单桩竖向极限承载力标准值; K——安全系数,取K=2。 1. 一般桩的经验参数法 此方法适用于除预制混凝土管桩以外的单桩。 按JGJ94-2008规范中第5.3.5条公式5.3.5计算: 式中: Q sk——总极限侧阻力标准值; Q pk——总极限端阻力标准值; u——桩身周长; l i——桩周第i 层土的厚度; A p——桩端面积; q sik——桩侧第i 层土的极限侧阻力标准值;参考JGJ94-2008规范表5.3.5-1取值,用户需在地质资料土层参数中设置此值;对于端承桩取q sik=0; q pk——极限端阻力标准值,参考JGJ94-2008规范表5.3.5- 2取值,用户需在地质资料土层参数中设置此值;对于摩擦桩取q pk=0; 2. 大直径人工挖孔桩(d≥800mm)单桩竖向极限承载力标准值的计算 此方法适用于大直径(d≥800mm)非预制混凝土管桩的单桩。按JGJ94-2008规范第5.3.6条公式5.3.6 计算: 式中: Q sk——总极限侧阻力标准值; Q pk——总极限端阻力标准值; q sik——桩侧第i层土的极限侧阻力标准值,可按JGJ94-2008规范中表5.3.5-1取值,用户 需 1取值,用户需在地质资料土层参数中设置此值;对于扩底桩变截面以上2d范围不计侧阻力;对于端承桩取q sik=0; q pk——桩径为800mm极限端阻力标准值,可按JGJ94-2008规范中表5.3.6- 1取值;用户需在地质资料土层参数中设置此值;对于摩擦桩取qpk=0; ψsi,ψp——大直径桩侧阻、端阻尺寸效应系数,按JGJ94-2008表5.3.6-2取值;

单桩竖向极限承载力和抗拔承载力计算书

塔吊基础计算书 一、计算参数如下: 非工作状态工作状态 基础所受的水平力H:66.2KN 22.5KN 基础所受的竖向力P:434KN 513KN 基础所受的倾覆力矩M:1683KN.m 1211KN.m 基础所受的扭矩Mk:0 67KN.m 取塔吊基础的最大荷载进行计算,即 F =513KN M =1683KN.m 二、钻孔灌注桩单桩承受荷载: 根据公式: (注:n为桩根数,a为塔身宽) 带入数据得 单桩最大压力: Qik压=872.04KN 单桩最大拔力:Qik拔=-615.54KN 三、钻孔灌注桩承载力计算 1、土层分布情况: 层号 土层名称 土层厚度(m) 侧阻qsia(Kpa) 端阻qpa(Kpa) 抗拔系数λi 4 粉质粘土 0.95 22 / 0.75 5 粉质粘土 4.6 13 / 0.75 7 粉质粘土 5.6 16 /

0.75 8-1 砾砂 7.3 38 1000 0.6 8-2 粉质粘土 8.9 25 500 0.75 8-3 粗砂 4.68 30 600 0.6 8-4a 粉质粘土 4.05 32 750 0.75 桩顶标高取至基坑底标高,取至场地下10m处,从4号土层开始。 2、单桩极限承载力标准值计算: 钻孔灌注桩直径取Ф800,试取桩长为30.0 米,进入8-3层 根据《建筑地基基础设计规范》(GB50007-2002)8.5.5条: 单桩竖向承载力特征值计算公式: 式中:Ra---单桩竖向承载力特征值; qpa,qsia---桩端端阻力,桩侧阻力特征值; Ap---桩底端横截面面积; up---桩身周边长度; li---第i层岩土层的厚度。 经计算:Ra=0.5024×600+2.512×(22×0.95+13×4.6+16×5.6+38×7.3+25×8.9+30×2.65)=2184.69KN>872.04KN满足要求。 单桩竖向抗拔承载力特征值计算公式: 式中:Ra,---单桩竖向承载力特征值; λi---桩周i层土抗拔承载力系数; Gpk ---单桩自重标准值(扣除地下水浮力) 经计算:Ra,=2.512×(22×0.95×0.75+13×4.6×0.75+16×5.6×0.75+38×7.3×0.6+25

单桩承载力特征值与设计值区别

单桩承载力设计值:=单桩极限承载力标准值/抗力分项系数(一般1.65左右) 单桩承载力特征值:=静载试验确定的单桩极限承载力标准值/2 1 、94桩基规范中单桩承载力有两个:单桩极限承载力标准值和单桩承载力设计值。单桩极限承载力标准值由载荷试验(破坏试验)或按94规范估算(端阻、侧阻均取极限承载力标准值),该值除以抗力分项系数(1.65、1.7,不同桩形系数稍有差别)为单桩承载力设计值,确定桩数时荷载取设计值(荷载效应基本组合),荷载设计值一般为荷载标准值(荷载效应标准组合)的1.25倍,这样荷载放大1.25倍,承载力极限值缩小1.65倍,实际上桩安全度还是2(1.25x1.65=2.06)。94规范时荷载都取设计值,为了荷载与设计值对应,引入了单桩承载力设计值,在确保桩基安全度不低于2的前提下,规定桩抗力分项系数取1.65左右。所以,单桩承载力设计值是在当时特定情况下(所有规范荷载均取设计值),人为设定的指标,并没有实际意义。 2、02规范中地基、桩基承载力均为特征值,该值为承载力极限值的1/2(安全度为2),对应荷载标准值。同一桩基设计,分别执行两本规范,结果应该是一样的。 单桩竖向承载力特征值按《建筑桩基技术规范》JGJ94 -2008第5.2.2条公式5.2.2计算: R a=Q uk/K 式中: R ——单桩竖向承载力特征值; a Q ——单桩竖向极限承载力标准值; uk K——安全系数,取K=2。 1. 一般桩的经验参数法 此方法适用于除预制混凝土管桩以外的单桩。 按JGJ94-2008规范中第5.3.5条公式5.3.5计算: 式中: Q ——总极限侧阻力标准值; sk Q ——总极限端阻力标准值; pk u——桩身周长; l ——桩周第i 层土的厚度; i A ——桩端面积; p q ——桩侧第i 层土的极限侧阻力标准值;参考JGJ94-2008规范表5.3.5-1取值,用户需在地质资sik 料土层参数中设置此值;对于端承桩取q sik=0; q ——极限端阻力标准值,参考JGJ94-2008规范表5.3.5- 2取值,用户需在地质资料土层pk 参数中设置此值;对于摩擦桩取q pk=0; 2. 大直径人工挖孔桩(d≥800mm)单桩竖向极限承载力标准值的计算 此方法适用于大直径(d≥800mm)非预制混凝土管桩的单桩。按JGJ94-2008规范第5.3.6条公式5.3.6计算:

单桩水平承载力计算

600 单桩水平承载力: ZH-600 600.1 基本资料 600.1.1 工程名称: 工程一 600.1.2 桩型:预应力混凝土管桩; 桩顶约束情况:铰接 600.1.3 管桩的编号 PHC-AB600(110),圆桩直径 d = 600mm ,管桩的壁厚 t = 110mm ; 纵向钢筋的根数、直径为 13φ10.7; 桩身配筋率 ρg = 0.826% 600.1.4 桩身混凝土强度等级 C80, f t = 2.218N/mm E c = 37969N/mm 纵向钢筋净保护层厚度 c = 25mm ; 钢筋弹性模量 E s = 200000N/mm 600.1.5 桩顶允许水平位移 x 0a = 10mm ; 桩侧土水平抗力系数的比例系数 m = 10MN/m 4 ; 桩的入土长度 h = 28m 600.2 计算结果 600.2.1 桩身换算截面受拉边缘的截面模量 W 0 600.2.1.1 扣除保护层厚度的桩直径 d 0 = d - 2c = 600-2*25 = 550mm 600.2.1.2 钢筋弹性模量与混凝土弹性模量的比值 αE = E s / E c = 200000/37969 = 5.2675 600.2.1.3 预应力混凝土管桩的内径 d 1 = d - 2t = 600-2*110 = 380mm 600.2.1.4 W 0 = π·[(d 4 - d 14) / d] / 32 + π·d·(αE - 1)·ρg ·d 02 / 16 = π*[(0.64-0.384)/0.6]/32+π*0.6*(5.2675-1)*0.00826*0.552/16 = 0.019051m 600.2.2 桩身抗弯刚度 EI 600.2.2.1 桩身换算截面惯性矩 I 0 = W 0·d 0 / 2 = 0.01905*0.55/2 = 0.0052390m 4 600.2.2.2 EI = 0.85E c ·I 0 = 0.85*37969*1000*0.005239 = 169079kN · m 600.2.3 桩的水平变形系数 α 按桩基规范式 5.7.5 确定: α = (m ·b 0 / EI)1/5 600.2.3.1 圆形桩当直径 d ≤ 1m 时 b 0 = 0.9(1.5d + 0.5) = 0.9*(1.5*0.6+0.5) = 1.260m 600.2.3.2 α = (m ·b 0 / EI)1/5 = (10000*1.26/169079)0.2 = 0.5949(1/m) 600.2.4 桩顶水平位移系数 νx 600.2.4.1 桩的换算埋深 αh = 0.5949*28 = 16.66m 600.2.4.2 查桩基规范表 5.7.2,桩顶水平位移系数 νx = 2.441 600.2.5 单桩水平承载力特征值按桩基规范式 5.7.2-2 确定: R ha = 0.75α3·EI·x 0a / νx 600.2.5.1 R ha = 0.75*0.59493*169079*0.01/2.441 = 109.4kN 600.2.5.2 验算地震作用桩基的水平承载力时,R haE = 1.25R ha = 136.7kN 9#,10#楼,查电算信息风荷载作用下基底剪力为Vx=1158kn,Vy=2077kn,地震作用下基底剪力为Vx=2292kn,Vy=3001kn.故由地震下控制。工程桩总桩数为64根。则作用于基桩顶处的水平力H ik 为3001/64=47kn< R ha .满足要求(还未考虑土对筏板的有利抗侧力). 2,3#楼,查电算信息风荷载作用下基底剪力为Vx=1098kn,Vy=1560kn,地震作用下基底剪力为Vx=2121kn,Vy=2048kn.故由地震下控制。工程桩总桩数为55根。则作用于基桩顶处的水平力H ik 为2121/55=39kn< R ha .满足要求(还未考虑土对筏板的有利抗侧力). 500 单桩水平承载力: ZH-500 500.1 基本资料 500.1.1 工程名称: 工程一 500.1.2 桩型:预应力混凝土管桩; 桩顶约束情况:铰接 500.1.3 管桩的编号 PHC-AB500(100),圆桩直径 d = 500mm ,管桩的壁厚 t = 100mm ; 纵向钢筋的根数、直径为 10φ10.7; 桩身配筋率 ρg = 0.877% 500.1.4 桩身混凝土强度等级 C80, f t = 2.218N/mm E c = 37969N/mm 纵向钢筋净保护层厚度 c = 25mm ; 钢筋弹性模量 E s = 200000N/mm 500.1.5 桩顶允许水平位移 x 0a = 10mm ; 桩侧土水平抗力系数的比例系数 m = 10MN/m 4 ; 桩的入土长度 h = 28m 500.2 计算结果 500.2.1 桩身换算截面受拉边缘的截面模量 W 0 500.2.1.1 扣除保护层厚度的桩直径 d 0 = d - 2c = 500-2*25 = 450mm 500.2.1.2 钢筋弹性模量与混凝土弹性模量的比值 αE = E s / E c = 200000/37969 = 5.2675 500.2.1.3 预应力混凝土管桩的内径 d 1 = d - 2t = 500-2*100 = 300mm 500.2.1.4 W 0 = π·[(d 4 - d 14) / d] / 32 + π·d·(αE - 1)·ρg ·d 02 / 16 = π*[(0.54-0.34)/0.5]/32+π*0.5*(5.2675-1)*0.00877*0.452/16 = 0.011425m 500.2.2 桩身抗弯刚度 EI 500.2.2.1 桩身换算截面惯性矩 I 0 = W 0·d 0 / 2 = 0.01143*0.45/2 = 0.0025707m 4 500.2.2.2 EI = 0.85E c ·I 0 = 0.85*37969*1000*0.0025707 = 82965kN · m 500.2.3 桩的水平变形系数 α 按桩基规范式 5.7.5 确定: α = (m ·b 0 / EI)1/5 500.2.3.1 圆形桩当直径 d ≤ 1m 时 b 0 = 0.9(1.5d + 0.5) = 0.9*(1.5*0.5+0.5) = 1.125m 500.2.3.2 α = (m ·b 0 / EI)1/5 = (10000*1.125/82965)0.2 = 0.6706(1/m) 500.2.4 桩顶水平位移系数 νx 500.2.4.1 桩的换算埋深 αh = 0.6706*28 = 18.78m 500.2.4.2 查桩基规范表 5.7.2,桩顶水平位移系数 νx = 2.441 500.2.5 单桩水平承载力特征值按桩基规范式 5.7.2-2 确定: R ha = 0.75α3·EI·x 0a / νx 500.2.5.1 R ha = 0.75*0.67063*82965*0.01/2.441 = 76.9kN 500.2.5.2 验算地震作用桩基的水平承载力时,R haE = 1.25R ha = 96.1kN 1#楼,查电算信息风荷载作用下基底剪力为Vx=955.5kn,Vy=3962.8kn,地震作用下基底剪力为Vx=4150.33kn,Vy=5372.60kn.故由地震下控制。工程桩总桩数为135根。则作用于基桩顶处的水平力H ik 为5372.60/135=39.8kn< R ha .满足要求(还未考虑土对筏板的有利抗侧力). 4#楼,查电算信息风荷载作用下基底剪力为Vx=895.6kn,Vy=1853.1kn,地震作用下基底剪力为 Vx=2005.43kn,Vy=2587.28kn.故由地震下控制。工程桩总桩数为66根。则作用于基桩顶处的水平力H ik 为2587.28/66=39.2kn< R ha .满足要求(还未考虑土对筏板的有利抗侧力).

单桩水平承载力设计值计算

结构构件计算书 第1页,共1页 单桩水平承载力设计值计算 项目名称_____________日 期_____________ 设 计 者_____________校 对 者_____________ 一、构件编号: ZH-1 二、依据规范: 《建筑桩基技术规范》(JGJ 94-2008) 三、计算信息 1.桩类型: 桩身配筋率<0.65%灌注桩 2.桩顶约束情况: 铰接、自由 3.截面类型: 圆形截面 4.桩身直径: d=600mm 5.材料信息: 1)混凝土强度等级: C35 ft=1.57N/mm 2 Ec=3.15*104N/mm 2 2)钢筋种类: HRB335 Es=2.0*105N/mm 2 3)钢筋面积: As=1608mm 2 4)净保护层厚度: c=50mm 6.其他信息: 1)桩入土深度: h=22.000m 2)桩侧土水平抗力系数的比例系数: m=30.000MN/m 4 7.受力信息: 桩顶竖向力: N=1550.000kN 四、计算过程: 1.计算桩身配筋率ρg: ρg=As/(π*d*d/4) =1608/(π*600*600/4)=0.569% 2.计算桩身换算截面受拉边缘的表面模量Wo: 扣除保护层的桩直径do=d-2*c=600-2*50=500mm 钢筋弹性模量Es 与混凝土弹性模量Ec 的比值 αE=Es/Ec=(2.0*105)/(3.15*104)=6.349 Wo=π*d/32*[d*d+2*(αE-1)*ρg*do*do] =π*0.600/32*[0.600*0.600+2*(6.349-1)*0.569%*0.500*0.500] =0.022m 3 3.计算桩身换算截面积An: An=π*d*d/4*[1+(αE-1)*ρg] =π*0.600*0.600/4*[1+(6.349-1)*0.569%] =0.291m 2 4.计算桩身抗弯刚度EI: 桩身换算截面惯性矩Io=Wo*d/2=0.022*0.600/2=0.007m 4 EI=0.85*Ec*Io=0.85*3.15*104*1000*0.007=176715.000kN*m 2 5.确定桩的水平变形系数α: 对于圆形桩,当直径d≤1m 时: bo=0.9*(1.5*d+0.5)=0.9*(1.5*0.600+0.5)=1.260m α=(m*bo/EI)(1/5) 【5.7.5】 =(30000.000*1.260/176715.000)(1/5)=0.735 (1/m) 6.计算桩顶(身)最大弯矩系数νm: 桩的换算埋深αh=0.735*22.000=16.161 查桩基规范表5. 7.2得:νm=0.768 7.其余参数: 圆形截面:桩截面模量塑性系数γm=2.00 竖向压力:桩顶竖向力影响系数ζ N=0.5 8.单桩水平承载力设计值Rh: Rh= α*γm*ft*Wo*(1.25+22*ρg)*(1±ζ N*N/γm/ ft / An)/νm 【5.7.2-1】 =0.735*2.000*1570.00*0.022*(1.25+22*0.569%)*(1+0.5*(1550.000)/2.000/1570.00/0.291)/0.768 =168.610kN

单桩承载力如何计算

单桩承载力如何计算 一、设计资料 1. 基桩设计参数成桩工艺:混 凝土预制桩 承载力设计参数取值:根据建筑桩基规范查表 孔口标高0.00m 桩顶标高0.50m 桩身设计直 径:d=0.80m 桩身长度:l=18.00m 2. 岩土设计参数层号土层名称层厚 (m)层底埋深(m)岩土物理力学指标极限侧阻力 3. qsik(kPa)极限端阻力 qpk(kPa) 层号土层名称层厚层底埋深岩土物理力学指标极限侧阻力极限端阻力 1 填土 3.003.00N=5.0017- 2 红粘土 3.006.00 a w=0.70 , IL=0.5026- 3 红粘土 3.009.00 a w=0.70 , IL=0.5029- 4 红粘土 3.0012.00 a w=0.70 , 5 红粘土 3.0015.00 a w=0.70 , 6 红粘土 3.0018.00 a w=0.70 , 《建筑桩基技术规范》(JGJ94-94)以下简称桩基规范 《建筑地基基础设计规范》 (GB50007-2002)以下简称基础规范 、单桩竖向抗压承载力估算 1. 计算参数表 土层计算厚度li(m)极限侧阻力qsik(kPa)极限端阻力qpk(kPa) 13.00 仃0 -------------------------------------------------------------------------------- 23.00260 33.00290 43.00320 53.00330 62.50342700 2. 桩身周长u 、桩端面积Ap 计算 u=x 0.80=2.51m Ap=x 0.802/4=0.50m23.单桩竖向抗压承 载力估算 根据桩基规范5.2.8按下式计算 Quk=Qsk+Qpk 土的总极限侧阻力标准 值为: IL=0.5032- IL=0.5033- IL=0.50342700 7 红粘土 3.0021.00 8 红粘土 3.0024.00 4. 设计依据 a w=0.70, IL=0.5032- a w=0.70, IL=0.5032-

单桩水平承载力设计值计算(参考)

单桩水平承载力设计值计算项目名称_____________日期_____________ 设计者_____________校对者_____________ 一、构件编号: ZH-1 二、依据规范: 《建筑桩基技术规范》(JGJ 94-94) 三、计算信息 1.桩类型: 钢筋混凝土预制桩 2.桩顶约束情况: 铰接、自由 3.截面类型: 方形截面 4.桩身边宽: d=400mm 5.材料信息: 1)混凝土强度等级: C20 ft=1.10N/mm2 Ec=2.55*104N/mm2 2)钢筋种类: HRB335 Es=2.0*105N/mm2 3)钢筋面积: As=1017mm2 4)净保护层厚度: c=50mm 6.其他信息: 1)桩入土深度: h=10.000m 2)桩侧土水平抗力系数的比例系数: m=14.000MN/m4 3)桩顶容许水平位移: χoa=10mm 四、计算过程: 1.计算桩身配筋率ρg: ρg=As/A=As/(d*d) =1017.000/(400.000*400.000)=0.636% 2.计算桩身换算截面受拉边缘的表面模量Wo: 扣除保护层的桩直径do=d-2*c=400-2*50=300mm 钢筋弹性模量Es与混凝土弹性模量Ec的比值 αE=Es/Ec=2.0*105/2.55*104=7.843 Wo=π*d/32*[d*d+2*(αE-1)*ρg*do*do] =π*0.400/32*[0.400*0.400+2*(7.843-1)*0.636%*0.300*0.300] =0.007m3 3.计算桩身抗弯刚度EI: 桩身换算截面惯性矩Io=Wo*d/2=0.007*0.400/2=0.001m4 EI=0.85*Ec*Io=0.85*2.55*104*1000*0.001=28570.447kN*m2 4.确定桩的水平变形系数α: 对于方形桩,当直径d≤1m时: bo=1.5*d+0.5=1.5*0.400+0.5=1.100m α=(m*bo/EI)(1/5)【5.4.5】 =(14000.000*1.100/28570.447)(1/5)=0.884 (1/m) 5.计算桩顶水平位移系数νx: 桩的换算埋深αh=0.884*10.000=8.837m 查桩基规范表5.4.2得: νX=2.441 6.单桩水平承载力设计值Rh:

800单桩承载力计算书

单桩承载力计算书 一、设计资料 1. 基桩设计参数 成桩工艺: 人工挖孔灌注桩 承载力设计参数取值: 人工填写 孔口标高0.00 m 桩顶标高0.50 m 桩身设计直径: d = 0.80 m 桩身长度: l = 10.00 m 中风化岩 37.50 砾砂 7.50填土5.00 孔口标高 3. 设计依据 《建筑桩基技术规范》(JGJ 94-94) 以下简称 桩基规范 《建筑地基基础设计规范》(GB 50007-2002) 以下简称 基础规范 二、单桩竖向抗压承载力估 1. ψsi ——大直径桩侧阻尺寸效应系数,按桩基规范表5. 2.9-2确定 2. 桩身周长u 、桩端面积A p 计算 u = π × 0.80 = 2.51 m A p = π × 0.802 / 4 = 0.50 m 2 3.单桩竖向抗压承载力估算 粘性土、粉土中ψsi = 1 砂土、碎石类土中ψsi = ????0.8d 1/3 = 1.00 ψp = ??? ?0.8 d 1/3 = 1.00

根据桩基规范5.2.9采用公式如下 Q uk = Q sk + Q pk 土的总极限侧阻力标准值为: Q sk = u∑ψsi q sik l i = 2.51 × (1.00 × 0 × 5.00 + 1.00 × 160 × 4.20) = 1687kN 总极限端阻力标准值为: Q pk = ψp q pk A p = 1.00 × 1800 × 0.50 = 905 kN 单桩竖向抗压极限承载力标准值为: Q uk = Q sk + Q pk = 1687 + 905 = 2592 kN 单桩竖向承载力特征值R a计算,根据基础规范附录Q条文Q.0.10第7条规定R a = Q uk/2 = 2592/ 2 = 1296 kN

单桩承载力计算

单桩承载力计算(DZCZ-1) 项目名称构件编号日期 设计校对审核 执行规范: 《混凝土结构设计规范》(GB 50010-2010), 本文简称《混凝土规范》 《建筑地基基础设计规范》(GB 50007-2011), 本文简称《地基规范》 《建筑抗震设计规范》(GB 50011-2010), 本文简称《抗震规范》 《建筑桩基技术规范》(JGJ 94-2008), 本文简称《桩基规范》 ----------------------------------------------------------------------- 《湿陷性黄土地区建筑规范》2004版第5.7.5条;本文简称《黄土规范》 《铁路桥涵地基及基础设计规范》2005版第6.2.2条中有关摩檫桩计算部分;本文简称《铁基规范》 ----------------------------------------------------------------------- 1. 设计资料 1.1 桩土关系简图

1.2 已知条件 (1) 桩参数 承载力性状端承摩擦桩

桩身材料与施工工艺混凝土预制桩 截面形状圆形 砼强度等级 C30 桩身纵筋级别 HRB335 直径(mm) 600 桩长(m) 10.000 (2) 计算内容参数 竖向承载力√ 计算方法经验参数法 考虑负摩阻ㄨ 水平承载力√ 桩顶约束情况固接 允许水平位移(mm) 10.0 纵筋保护层厚(mm) 60 抗拔承载力√ 软弱下卧层√ 承载力比 0.33 均匀分布侧阻比 0.50 考虑地基液化不考虑 (m)高(m)(kN/m3 )(kN/m3)(kPa)(kPa)(MN/m4 )

CFG桩单桩竖向抗压承载力特征值计算

CFG桩计算书 工程名称:长动还建楼住宅小区 设计依据:《复合地基技术规范》(GB/T50783-2012) 1、计算CFG桩单桩竖向抗压承载力特征值(第、条) 计算公式:Ra=Up*Σqsai*li+α*qp*Ap CFG桩桩身直径D=500mm,桩端持力层为强风化泥质粉砂岩,桩端全断面进入持力层深度hr≥;有效桩长 L≥米。 Up=*=(m);Ap=**4=(m2) 取qsa1=30kPa,L1=;qsa2=50kPa,L2=;qsa3=80kPa,L2= 桩端土地基承载力折减系数α=,qp=800kPa Ra==380+=(kN) 取Ra=530kN 2、计算CFG桩桩体强度(第、条) 计算公式:Ra=η*fcu*Ap;fcu=Ra/(η* Ap) 桩体强度折减系数η= fcu=530/(*)=8194(kPa)= 取fcu=20MPa 3、CFG桩复合地基承载力计算(第、条)

计算公式:fspk=βp*m*Ra/Ap+βs*(1-m)*fsk βp=,βs= Ra=530kN,fsk=fak=220kPa D=,S=3*=(m),De=*=(m) m=D*D/(De*De)= fspk=**530/+*()*220=+=(kPa) 取fspk=370kPa CFG桩计算书 工程名称:长动还建楼住宅小区 设计依据:《建筑地基处理技术规范》(JGJ 79-2012) 1、计算CFG桩单桩竖向抗压承载力特征值(第、条) 计算公式:Ra=Up*Σqsai*li+α*qp*Ap CFG桩桩身直径D=500mm,桩端持力层为强风化泥岩,桩端全断面进入持力层深度hr深度hr≥;有效桩长 L≥米。 Up=*=(m);Ap=**4=(m2) 取qsa1=35kPa,L1=;qsa2=50kPa,L2= 桩端土地基承载力折减系数α=,qp=700kPa Ra=*(40*+60*)+*700*=+=(kN) 取Ra=540kN

单桩承载力计算

单桩承载力计算 城南路(高浪路~吴都路)工程水中钢管桩承载力计算本工程桩机平台及现浇箱梁水中部分的基础均采用Φ377的钢管桩作为主要受力构件,上铺14#、20#方钢作为纵横梁与下部的钢管桩有效连接,形成整个基础受力体系。实测水位1.74m,河床-1.00m,钢管桩总长7m,出水1m(桩顶标高2.74m),入土深度3.26m(桩底标高-4.26) 考虑到钢管桩为开口式打入,承载力计算时主要以摩擦力为主。参考本工程水中范围内的地质报告,我部钢管桩主要进入的地质层为③2层及④层,分别为粉质粘土夹粉土和粉土层。其地基承载力特征值及侧壁摩擦阻力分别为: ③2粉质粘土夹粉土:τi=49.2kPa,бR=140kPa,土层范围(-0.69~-3.29) ④粉土:τi=66.1kPa,бR=160kPa,土层范围(-3.29~-9.39)单桩容许承载力[P]=1[桩侧极限摩阻力Psu+桩底极限阻力Ppu] 安全系数K (1)打入桩容许承载力按下式计算 1[P][U ili i A R] 2 P-单桩轴向受压容许承载力kN U-桩周长m li-桩在承台底面或最大冲刷线一下的第i层土层中的长度m i-于li相对应的各土层与桩侧的极限摩擦阻力kPa A-桩底面积㎡ R-桩底处土的极限承载力kPa i -分别为振动下沉对各土层桩侧摩阻力和桩底抵抗力的影响系数,打入桩其值均为1 单根容许承载力: [P]=0.5×(αAбR +U∑αiLiτi) =0.5*(1*0.377*3.14*0.2*140+3.14*0.377*(2.29*49.2+0.97*66.1)) =121.2KN=12.12T ㎡ ㎡ 断面范围内为水中满堂支架施工,长度L=10.4m,该段混凝土方量为: