abstract: in the high-rise building design work, how to better in the design perfect building use function, and improve the safety of the electrical system is building electrical design personnel duty. through the design practice and understanding, summarized some experiences, present here, for discussion.

keywords: high building, building electrical, design concept

中图分类号:tu976+.1 文献标识码:a文章编号:

1建筑电气设计的概念

设计是一个构思表达、再构思表达、反复推敲、不断深入发展和

进行评价的过程。基本上可以概括为博览、创意、构思、表达等几个阶段。设计过程从一开始到深入下去,各阶段思维的广度、深度都不同,表达方式、工具也可能是多样化的。表达方式和工具要适应思维的速度,推动思维发展成熟。

2高层建筑供电系统设计

2.1 电力负荷的确定

电力负荷是供电设计的主要依据。国家现行规范,一类高层民用建筑的消防用电设备(如消防水泵、消防电梯、喷淋泵、排烟风机、消控控制中心、应急照明)、电梯、生活水泵用电、电话机房、安保设备和航空障碍灯等应按一级负荷要求供电,其它用电负荷分别为二级或三级负荷;二类高层民用建筑的消防用电、通道及楼梯间照明用电、电梯电力、生活水泵用电、排污泵等应按二级负荷要求供电,其它用电负荷为三级负荷。电力负荷预算时应分别计算动力电和照明电。电力负荷预算正确与否,对电气设备的选择、配置,保证电气设备系统安全、高效运行,对整体工程的经济分析和相关设计,都有重要的指导意义。高层建筑的电力负荷计算,基本上采用负荷密度法和需要系数法。

2.2 电源及电压的选择

至少设两个独立电源,采用10kv标准电压双回路供电。两路各带一半负荷同时供电、互为备用。10kv双回路供电电源分别来自不同的变电站,或来自双回路超高压变电站的两段独立母线。

某些超高层公共建筑可选择10kv三回路电源引入,采用两路使用一路备用的运行方式。针对高层建筑中存在大量的一级负荷,还需备用柴油发电机组,要求在15s内自动恢复供电,应付意外情况的发生。

2.3变配电所的布置。

对于高层建筑的用电设备来说,它们的负荷是比较大的,一般来说很大的一部分是一、二级负荷,所以常常变电所的规模一般来说会比较的大。总配电所最好是设置在地下层内,因为变配电所应靠近用电负荷。对于高层建筑的总变配电所来说,管线进出的程度会比较多,有高压也有低压的电缆。

2.4高低配电系统的设计

2.4.1高压配电系统:现代高层建筑均是采用两路独立的10kv电源同时供电。一般高压采用单母线分段,自动切换,互为备用。母线分段数目,与电源进线回路数相适应。只有当供电电源为一主一备时,才考虑采用单母线不分段的结线。电源进线几乎全部采用电缆进线。

2.4.2计费方式,采用高供高计。但在低压侧,仍装设计费电度表,采用将照明与动力分开的两部电价法。有些地方供电部门又把空调设备的用电,全部划人照明计价系统,一般做法是安装总表及动力表,由总表减去动力表以后,全部为照明电费。

2.4.3为减少变压器台数,单台变压器的容量选择一般都大于1000kva。为限制低压侧的短路电流,正常时变压器解列运行,中间设联络开关。照明和动力分开设变压器,当动力用电容量太小时,动力变压器可不分开装设,而在低压侧应对动力负荷分类计费。2.4.4高压系统及低压干线的配电方式基本上都采用放射式系统。楼层配电则为混合式系统。配电设备中的主要部分是干线。现代高

层建筑的竖井多采用插接式母线槽。水平干线因走线困难,多采用全塑电缆与竖井母干线联接。每层楼竖井设层间配电小间。层间配电箱经插接自动空气开关从竖井母干线取得电源。当层数较多负荷数较大时,一般按层数分区供电,或将变压器分散设在地下层、中间层或最顶层。

3注意高层建筑电气设计中的几个问题

3.1高层建筑由于照明及空调负荷多,电梯等运输设备多,给排水设备多,所以用电量特别大,且供电的可靠性要求很高。

3.2 在高层建筑中,照明与动力基本上不共用干线。动力负荷多采用放射式供电,照明负荷则多采用母线槽配电,与动力分开。

3.3由于在结构上多数采用大柱距,形成大空间,使墙面安装的设备增多,必然使地面管道增多。

3.4由于建筑构件的预制装配化及干法施工;缩短了施工周期,而且顶棚一般采用标准化、系统化的吊顶。

3.5电气设备的管线应采取防火措施。

3.6空调设备等主要用电设备分散,多数要求集中管理,即要求采用电脑管理和监控系统。

3.7采取防震措施。如配电屏、灯具等电气设备的防震;管线的层间贯通和建筑伸缩缝与沉降缝的耐震处理等。

4建筑电气设计中的节能原则

由于人口的增加,工业的发展,生活水平的提高,能源的消耗也就

急剧增加,能源危机迫在眉睫。因此,各行各业提出了节能的要求,节约二次能源——电能,也就成为民用建筑电气设计的焦点。建筑电气设计节能的原则建筑电气节能应坚持以下三个原则:

4.1满足建筑物的功能即满足照明的照度、色温、显色指数;满足舒适性空调的温度及新风量,也就是舒适卫生;满足上下、左右的运输通道畅通无阻;满足特殊工艺要求,如娱乐场所的一些电气设施的用电,展厅的工艺照明及电力用电等。

4.2考虑实际经济效益节能应按国情考虑实际经济效益,不能因为节能而过高地消耗投资,增加运行费用。而是应该让增加的部分投资,能在几年或较短的时间内用节能减少下来的运行费用进行回收。

4.3节省无谓消耗的能量节能的着眼点,应是节省无谓消耗的能量。首先找出哪些地方的能量消耗是与发挥建筑物功能无关的,再考虑采取什么措施节能。如变压器的功率损耗,传输电能线路上的有功损耗都是无用的能量损耗,又如量大面广的照明容量,宜采用先进技术使其能耗降低。

因此,节能措施也应贯彻实用、经济合理、技术先进的原则。民用建筑的节能潜力很大,应在设计中精心考虑。但是在选用节能的新设备上,应具体了解其原理、性能、效果,从技术、经济上进行比较后,再选定节能设备,以达到真正节能的目的。

5智能化发展

在科学技术日新月异的今天,随着微机自动检测及控制技术、计算机网络技术、通讯技术的发展,楼宇智能化的实现已成为可能。未来的住宅楼应有一个由检测单元、执行单元、数据采集单元、控制单元和微机组成的智能监控系统,由该系统对楼宇内的设备运行、电气故障、火灾、盗情等进行集中监控。再设置综合布线系统,将一定区域内的楼宇按星型拓朴结构建成小区局域网,进而所有局域网连接,同时与公安、消防、电讯、广播住宅管理等部门连网从而建成城市住宅管理信息网络,实现住宅的全天候、全方位监控和管理。

6结语

随着城市规模的不断发展,高层建筑越来越多,因此,高层建筑电气设计就成为设计者不得不面对的问题,同时,在能源紧张的今天,更要注重节能的设计。

现代建筑电气设计

对现代建筑电气设计问题的探讨 【摘要】随着社会经济的发展,现代建筑的功能越来越强,建筑电气的重要性也日益明显。在市场竞争日益激烈的前提下,建筑设计的理念也不断变化,适应市场,满足客户需求是每一位设计工作者不断提升自己的原动力,这需要我们每一位建筑电气设计人员随时去关注市场、了解市场,才能掌握市场动态,把握主动权。 一、建筑电气设计的概念和内容 关于设计的概念问题,所谓设计它是一个把构思进行表达,然后再构思再表达,持续发展与评价的过程,可以分为以下几个阶段,包括博览与创意,构思与表达。设计的每一个阶段无论从深度还是广度都不一样,而且,表达的工具与方式也是多式多样的,表达的工具与方式要与思维的速度相适应,它对思维发展的成熟起着重要的推动作用。 建筑电气设计内容从狭义上仅指民用建筑中的电气设计,从广义上讲应该包括工业建筑、构筑物和道路、广场等户外工程。传统建筑电气设计只包括供电和照明,而今天一般将其设计的内容形容为强电和弱电。将供电、照明、防雷归类在强电,而其余部分,如电话、电视、消防和楼宇自控等内容统统归于弱电。 二、建筑电气设计的原则 建筑电气设计严格遵守相关的设计规范。设计规范是国家或地方制定的设计准则,它体现了国家的政策和对建筑的质量要求,是建筑电气设计者设计的标准。建筑电气设计应满足建筑的功能需求,保证

建筑的各项功能稳定连续运行,给居民的日常生活带来方便、快捷。建筑电气设计是建筑的一部分,在设计过程中也要考虑综合经济因素,既要考虑初投资也要兼顾以后的运行费用,以求得建筑生命周期内费用最低的目标。 三、目前我国建筑电气设计中存在的问题 1、关于配电回路方面的问题 每一户的住宅室里都不能有太少的配电回路,因为配电回路太少的话,就会导致回路的负荷加大,也就相当于导线截面的减少。像空调电源插座、照明、电源插座、卫生间电源插座以及厨房电源插座都是从配电箱出来的分支回路,现在的住宅中,卧室与客厅基本都安有空调,空调器负荷有大有小,也就决定了空调的回路数量,一般情况下都在五个以上。除此之外,还有电话线路、有线电视,最少也有7路的管线进入居室,并且在这7路的管线中只有照明的辐射是在顶板,其它的管线都在地面的垫层里面,而且肯定会有交叉现象。而住宅的垫层又非常薄,线路管线错乱交叉处理起来非常困难,而住户在铺地板的时候,通常会打断地坪里的管线,这样就会导致电气使用起来非常的不安全,也非常的不方便。如果把暗敷线路在进行敷设时与地面保持平行或者与墙缝保持垂直的话,那么,以上所说的问题就不会发生,管线交叉的问题完全能在墙缝中解决好,关于照明的线路完全可以在墙的拐弯处通过接线盒对其进行分线,住户要想了解分支回路的位置与方向,就可以通过配电平面图进行了解,这样,也很好的避免了在铺设地板的时候打断管线的问题。

建筑电气在高层建筑施工中的应用

建筑电气在高层建筑施工中的应用 发表时间:2017-11-04T08:41:25.253Z 来源:《电力设备》2017年第16期作者:张强 [导读] 在目前的建筑工程项目中,高层建筑耗能浪费现象也成为社会发展中的一个迫在眉睫的话题,这就需要我们工作中进行深入系统的研究,针对工程项目中存在的问题进行了研究,并详细的研究和探索我 (北京华望电力工程咨询有限公司北京 100070) 摘要:在目前的社会发展中,高层建筑如雨后春笋般涌现了出来,其施工质量和施工功能也逐渐得到了认可。但是就目前的高层建筑工程项目中,建筑电气设计施工质量仍然较为欠缺,还存在着一定的质量问题,成为我们在工作中研究的主要话题。同时,在目前的建筑工程项目中,高层建筑耗能浪费现象也成为社会发展中的一个迫在眉睫的话题,这就需要我们工作中进行深入系统的研究,针对工程项目中存在的问题进行了研究,并详细的研究和探索我们在工作中极容易见到的各种质量话题和问题。 关键词:高层建筑;设计;安装;要点 一、引言 在高层建筑中,由于楼层多,居民户数也多,民用用电以及消防用电的消耗较大,并且各电气设备的功率不同,因此用电量的大小也有较大的差别,这就加大了电能的耗费,从而要求高层建筑的供电设备必须保证高质量,同时,为了保证供电设备的安全运行以及提升可靠程度,就需要有两个单独的电源来进行供电,例如:消防、电梯以及应急照明等。 二、高层建筑电气设计的要点 1、供配电系统设计 (1)造成高层建筑高电力负荷的原因是因为消防设备、空调制冷装置以及照明等电气设备的共同使用。在这些高耗电的用电设备中,动力负荷以及照明所用电量占总数的30%,其余的占40%,在耗电设备中,消防用电是非常重要的。由于高层建筑楼层多,人员聚集量较大,内部装潢容纳的易燃易熔材料很多,发生火灾的概率相当高,如果发生火灾,因为高层建筑内部结构较为复杂多变,人员在逃生时会遇到种种阻碍,这会给人民及社会带来严重的经济损失。因此,在一般条件下,高层建筑应当将消防用电放在首位,一类高层置于一级负荷之列,二类高层置于二级负荷之列。 (2)供电电源电压及主接线。 因为高层建筑电力负荷重,因此应该采用高压来给整栋楼供电,高压等级是10kV。在现阶段,以单母线制作为供电系统主结线的高层建筑以及工矿企业单位越来越多,这样的主结线结构简单,还大大减少设备的占用空间以及投入资金,经济效益十分显著。在高层建筑中,用电负荷有一级和二级之分,一级负荷指的是供电设备是由两个独立电源来提供的,二级负荷则指的是供电由双回路线来提供,如果双回路线行不通的话,可以采用一回路的专线来提供电力。在对供电的设施进行改良的基础上,高层供电的持续稳定在得以保证。所以在设计线路时,对高压双回路和三回路在进线时要采取内桥接法,另外在对低压的处理上要采取单母线来进行分段,由母线开关来控制各分段母线上的负荷量。如果有些非常重要的负荷,就要准备柴油发电机来作为不时之需。 (3)选择适用的变压器。 现在有许多高层建筑选择使用大容量的变压器作为自己楼层的变压设备,虽然这能够很好的解决效率的问题,但会相应的增加电力负荷的承载量。因此,应该依据自身的实际需求量,在对各方面加以考证之后来做出正确的选择。专用型的变压器可以依据空调的分布来安置,这可以根据空调分组的情况来选择合适的变压器及数量,保证了经济上的合算。 2、照明设计 高层建筑对照明的设计,包括:灯具的造型、灯具的摆放、照度以及光源的类型等方面。电气在照明上的设计是和室内装饰分不开的,所以二者应该相辅相成,相互辉映,在保证使用的同时也要满足艺术审美的需求。目前的高层建筑,大量采用传感器、光敏元件以及定时器作为自动控制照明的设施,在对照明系统自动化的基础上来完善电路和接触器。此外,还要使用高光效的光源,作为节能的办法之一。 3、电梯设计 电梯的机房设置在井道顶端。电梯的梯井在设置时是可以连通的。电梯如果按照用途来划分的话,可以分为客用和货用两种类型;如果按照运行的速度来划分的话,可以分为低速、快速、高速以及超高速几种类型;如果按照供电电源来分,可以分为直流与交流两种类型。目前高层建筑中,电梯的使用多半会采用高速甚至超高速,这样可以以最短时间达到运行的高效率,控制采取分组的方式。客用电梯较多的采用直流电动机,这样可以保证人员的舒适度。 4、防火和报警系统设计 现代社会,科技不断创新与应用,在高层建筑中,为应对火灾的发生而设计的自动报警灭火设备也有了更进一步的发展。这一灭火机制是由五个部分组成的,即:消防中心、火灾探测器、气体自动喷射、分区消防报警控制器以及自动洒水灭火器。在实际运行中,火灾探测器首先探测到火灾情况,并将这一信息以电信号的方式发送给报警控制器和消防中心,然后报警器鸣响,消防中心也能够做出及时的部署。 5、节能设计 高层建筑中采用节能化的电气设计是信息技术与建筑技术相融合的产物,它大大推动了建筑业内技术的发展与应用,高层建筑因其楼层等的原因造成结构的复杂而且所需的功能也很多,所以,节能化在高层建筑中的设计及管理也应该得到严格的控制。类型不同的设备,功能上也存在着差别。所以,对于新技术的更新,我们没必要盲目追求,而是应该根据实际需要选择最适合自己的技术,方案的设计应既实惠,又便于操作,使系统能够简化,做到技术和经济的合二为一。 三、高层建筑电气的安装 高层建筑电气安装工程除了和土建有着密切的关系需要协调配合以外,还和其它安装工程,如给排水工程、弱电系统、消防系统、以及电梯系统等工程有着密切的关系。施工前应做好图纸的联合会审工作,以避免发生安装位置的冲突。互相平行或交叉安装时,必须保证

高层建筑电气设计要点

高层建筑电气设计要点 一、常见问题 1.电力负荷是供电设计的依据参数。 计算准确与否,对合理选择设备,安全可靠与经济运行,均起决定性作用。高层建筑的电力负荷计算,基本上采用负荷密度法和需要系数法。 2.供电电源及电压的选择 为了保证供电可靠性,现代高层建筑至少应有两个独立电源,具体数量应视负荷大小及当地电网条件而定。两路独立电源运行方式,原则上是两路同时供电,互为备用。另外,还须装设应急备用柴油发电机组,要求在15秒钟内自动恢复供电,保证事故照明、电脑设备、消防设备、电梯等设备的事故用电。 国内高层建筑的供电电压,都采用10kv标准电压等级。 3.高低压配电系统的设计 (1)高压配电系统:现代高层建筑均是采用两路独立的10kv电源同时供电。一般高压采用单母线分段,自动切换,互为备用。母线分段数目,与电源进线回路数相适应。只有当供电电源为一主一备时,才考虑采用单母线不分段的结线。电源进线几乎全部采用电缆进线。 (2)计费方式,采用高供高计。但在低压侧,仍装设计费电度表,采用将照明与动力分开的两部电价法。有些地方供电部门又把空调设备的用电,全部划入照明计价系统,一般做法是安装总表及动力表,由总表减去动力表以后,全部为照明电费。

(3)为减少变压器台数,单台变压器的容量选择一般都大于1000 kva。为限制低压侧的短路电流,正常时变压器解列运行,中间设联络开关。照明和动力分开设变压器,当动力用电容量太小时,动力变压器可不分开装设,而在低压侧应对动力负荷分类计费。 (4)高压系统及低压干线的配电方式基本上都采用放射式系统。楼层配电则为混合式系统。配电设备中的主要部分是干线。现代高层建筑的竖井多采用插接式母线槽。水平干线因走线困难,多采用全塑电缆与竖井母干线联接。每层楼竖井设层问配电小问。层间配电箱经插接自动空气开关从竖井母干线取得电源。当层数较多负荷数较大时,一般按层数分区供电,或将变压器分散设在地下层、中间层或最顶层。 (5)低压配电系统各级开关均采用自动空气开关(断路器),设置瞬时、短延时、长延时三级过流保护装置。各级自动空气开关的保护整定,应注意选择性配合,防止越级跳闸。 (6)所有电梯均要求采用两路不同变压器引出的专用电缆进线。在电梯机房的末端配电箱,设两路电源的自动切换装置,互为备用。 (7)功率因数按规定应补偿到0.9—0.95。无功补偿都采用集中补偿方式。为降低变压器容量,多集中装设在低压侧,与配电屏放在一起,但必须采用于式移相电容器。 4.主要设备的选型

2020新版浅谈高层建筑的消防电气设计

( 安全论文 ) 单位:_________________________ 姓名:_________________________ 日期:_________________________ 精品文档 / Word文档 / 文字可改 2020新版浅谈高层建筑的消防 电气设计 Safety is inseparable from production and efficiency. Only when safety is good can we ensure better production. Pay attention to safety at all times.

2020新版浅谈高层建筑的消防电气设计 摘要:随着城市的发展,人民生活水平的提高,技术的进步,保护耕地意识越来越强,高层建筑越来越多,应用于高层建筑的配套设备也随着增加,对建筑电气设计不断提出新的要求,同时随着科学技术的进步,高层建筑正朝着自动化、节能化、信息化、智能化方向飞速发展,本文就高层建筑电气设计的有关问题做一些探讨。 近年来,随着城市建设的发展,现代化的高层建筑越来越多,高层建筑一般建筑面积大、人员密度高、使用功能比较复杂并且火灾危险性大,万一发生火灾,火势蔓延速度快,扑救难度大,人员疏散较为困难,烟雾很容易使人窒息死亡。因此,必须设置专门的防烟、排烟风机,早期的报警及消防自动灭火也极为重要,它可以将火灾扑灭在萌芽状态,同时也为人员的安全疏散赢得宝贵的时间。下面就对高层建筑消防电气设计中的部分问题进行了分析探讨。

1、高层建筑消防供电 1.1消防电源 消防电源是消防用电设备供给电能的独立电源。现代建筑中应用电能的消防设备有两大类,一类是为建筑提供照明、动力,即电力(强电)设备;另一类是传递信息和控制信号,即电子(弱电)设备。这两类设备按需要组合成若干功能性子系统如:消防控制室、消防水泵、消防电梯、防排烟设施、火灾自动报警、消防联动控制、自动灭火、应急照明、疏散指示标志以及电动的防火墙、门、窗、卷帘、阀门等,从而构成完备的、功能复杂的建筑消防电气系统。消防用电设备是用以保障人身和财产安全的设备,要求其供电电源必须安全可靠。不仅要求在正常情况下、而且当电网停电或发生火灾断电等种种特殊情况时,都能够为各种消防用电设备提供充足可靠的电能,确保消防设备正常工作。 1.2消防供电 通常,大楼内的供电变压器至少有两台以上,若以两台为例,则低压侧的两段母线平时是各自单独运行,只有当其中一台变压器

现代建筑电气设计的特点及发展

一、现代化建筑电气的概念及其发展 现代化建筑电气是当今的一门独立的学科,主要是借助建筑物的平台,充分发挥现代电气技术的优势。在建筑有限的空间内,最大限度的创作人性化的生活环境。在现代化建筑物飞速发展的今天,建筑物的电气化设计也起到越来越重要的作用。建筑电气的发展是伴随着建筑水平的发展而发展的,经过不断的实践,已经形成比较完整的理论体系,其已经发展到建筑供电技术、电气控制技术、电气安全及自动化技术。鉴于建筑物设计的不断进步,电气化设计也发生了变化,体现出了相应的设计特点,电气化设计实现了跨越式的发展。随着改革开放的不断深入,大量新的产品技术不断的引进,我国的建筑电气化设计得到了不断的进步和发展。 二、现代建筑电气设计的特点 现代建筑电气设计的特点是根据现代电气设计的原则而表现出来的相应的特点,一般的建筑物电气设计中都遵循相关的原则。 (1)要最大程度的满足建筑物的使用功能,其中包括建筑物内部的照明功能。保障建筑物内部的风量及其温度,还要满足建筑物其外在的建筑物的工艺要求。 (2)建筑物电气设计要充分考虑其经济效益。在技术设计上要充分考虑其电气设计的成本核算和提高电气设备的利用效率,把握好工艺节能成本等。 (3)充分考虑节能成本,利用新技术新设备降低电气设备的消耗。从细节出发,研究具体的节能途径。 现代建筑电气设计在其遵循的基本原则下,其设计特点有如下几点。 (1)系统相比较来说比较复杂 现代建筑工程总的建筑面积相对较大,相应的用电需求也比较大。整体来说,电气设计系统比较复杂。 (2)电气设计的功能比较繁多 现代建筑是电气设备使用的综合性建筑,以其功能的多样化和设备的电气要求决定了电气设计的复杂性。 (3)建筑设计的难度比较大 由于项目的不同需要,在电气设计的时候通常要多方协调。应兼顾多方需求,分清主次,统筹协调。 三、建筑电气设计发展趋势

某超高层建筑电气设计实例

万方数据

Bl变电所(O),用于商业及办公:∑Pn=2888kW, Sc=2107kVA,ESr=2拳1600kVA; L14变电所(A),用于公寓:∑Pn=2212kW, Sc=1390kVA,ESr=2木1000kVA I L14变电所(H),用于酒店:EPn=3269kW, Sc=1975kVA,∑Sr=2术1250kVA。 (3)备用柴油发电机房设置在地下1层靠首层外墙部位。 3.3配电问设置 尺度要实际测算,满足电气设备、电缆的排布及操作距离的要求。 (1)B4~L5平面尺度大,功能种类多,设置多处配电间; (2)上部设置一处配电间,办公层配电间尺度为 4.7m x 1.8m,公寓酒店层配电间尺度为2.3m×2.9m。 离屠及超赢层建筇告钮 过于笼统,不具有指导意义,好在《民用建筑设计规范》的附录中给出了细化的划分方法。 但本人认为这种划分方法仍缺乏明晰、确切的基础原则,在IEC60364.5—55中,原则则比较清晰,是以供电中断允许间隔时间来划分等级的: 图1变电所及配电间分布示意图0级(不间断):不间断自动供电 3.4变配电系统概略图如图2所示。 0?15级(极短时间间隔):0?15s之内自动恢复有 需特别说明的问题是:B3,L14变电所远离高压,双侠电 配电室,为了变压器的维护安全,在现场应设置隔离装0.5级(短时间间隔):O_Ss之内自动恢复有效供电 置(保护在B1实现),系统示意如图3所示。 15级(中等时间间隔):15s之内自动尉彰弼吲也 4关于供电可靠性 >15级(长时间间隔):>15s之内自动恢复有效 4.1规范要求 而’ 在我国的电气设计中,负荷分级及相应的供电要建议我国的国家标准也按此进行划分,并给出相求都是以《供配电系统设计规范》为基础的,第2.0.1应的供电保障措施。 条给出了其分级原则:“电力负荷应根据对供电可靠4.2负荷等级划分 性的要求及中断供电在政治、经济上所造成损失或影本建筑中负荷等级划分如下:响的程度进行分级……”,这一原则对民用建筑而言 (1)一级负荷: 馨篚建锅电气投术19   万方数据

高层住宅楼供配电

毕业设计 高层住宅楼供配电系统的设计 姓名: 学号: 班级: 11电气1 专业:电气工程及其自动化 所在系:自动化工程系 指导教师:

高层住宅楼供配电系统的设计 摘要 我国的城市建设过程中,住宅向着高层化趋势发展。高层住宅楼,因其为住户提供的安全、舒适、高效、节能的居住环境,受到了越来越多人的青睐,也成为现代人主要的居住方式。与此同时,高质量的高层住宅楼供配电系统的设计就显得尤为重要。在电气设计时既要考虑用电负荷日益增长的需要,又要满足供电的可靠性及安全性的要求。 本课题以高层建筑的供配电系统为研究对象。为了达到用户能够安全、可靠、高效用电的目的,我们对高层建筑的供配电系统整体进行设计。其中包括对建筑负荷的计算,选择恰当地供电方式;进行短路电流的计算,选择合适的导线及低压电器产品;对室内照明进行设计;对防雷接地的设计等。同时为了提高设计质量及缩短设计周期,本课题采用功能强大的建筑电气软件CAD来设计供配电系统的电路图。 关键词:电气设计;安全性;负荷计算;防雷接地;软件AutoCAD

The Design of High-rise Residential Building Power Supply and Distribution System ABSTRACT In the process of urban construction in our country, the housing development trend towards upwards. High-rise residential buildings, because of its for residents to provide safe, comfortable, efficient and energy saving living environment, got the favour of more and more people, modern has become the main way of living. At the same time, the high quality of high-rise residential building design of power supply and distribution system is particularly important. In the electrical design should not only consider the increasing needs of the power load, and to meet the requirements of the reliability and security of the power supply. This topic in power supply system of high-rise building as the research object. In order to achieve the user to the purpose of safe, reliable and efficient utilization, our power supply system of high-rise building the overall design. Including the building load calculation, choose proper power supply way; For the calculation of short-circuit current, select the appropriate conductor and low-voltage electrical products; For indoor lighting design; The design of lightning protection grounding, etc. At the same time in order to improve the design quality and shorten the design cycle, this subject adopts powerful building electrical software AutoCAD to design the circuit diagram of power supply and distribution system. Key Words: Electrical Design ;security;Load calculation;Lightning protection and grounding;Software AutoCAD

浅谈高层建筑电气中供配电设计

浅谈高层建筑电气中供配电设计 发表时间:2017-11-10T15:59:36.363Z 来源:《基层建设》2017年第22期作者:曾常荣 [导读] 摘要:近年来,建筑行业蓬勃发展,建筑高度越老越高,城市中高楼林立,高层建筑的电气系统设计与实现成为了高层建筑施工中的重要问题。 东莞市力中建设发展有限公司广东东莞 523000 摘要:近年来,建筑行业蓬勃发展,建筑高度越老越高,城市中高楼林立,高层建筑的电气系统设计与实现成为了高层建筑施工中的重要问题。现代的高层建筑结构较为复杂,且需要满足不同用户的性能需求,在一栋高层建筑中,既有家庭用电,也有商业用电,在不同供电需求下,要求电气中配供电的设计能够具有针对性,而不是传统的单一供配电方式。与此同时,还要满足安全性、稳定性、可靠性以及节能等方面的要求。 关键词:高层建筑;电气系统;供配电设计;设计原则;设计方法 当前,城市供电较为紧张,且出现了多个高峰时段,要保持整个城市供电的稳定、安全和持续性,就必须在不断时段,采取不同的供配电方式,这就要求单个的供配电设计要做到科学合理。高层建筑的电气系统作为城市供电系统的组成部分,其供配电设计尤为重要,它不仅直接影响到业主的日常生活和建筑的生产工作,同时也对整个城市的供电造成影响。在下文当中,笔者将对高层建筑电气中的供配电设计进行分析,提出设计原则,并阐述具体的设计办法,着力提升高层建筑电气系统供配电设计的合理性。 一、高层建筑供配电设计简述 现在大多数城市在发展过程中所进行的工程建设工作,高层建筑在城市建设中所占的比重越来越大,高层建筑有效利用了城市有限的土地资源,提高了单位面积内土地资源的利用效率,我城市下一步的发展打造了一定的资源优势。但同时,高层建筑也会带来一些新的问题,如高层建筑的高度、结构复杂,更重要的是电源线的配置将变得更加复杂,对供配电设计的专业要求也更高,高层建筑布线系统一旦出现问题,其检查和维修工作的开展远比一般建筑的电力维修更加困难。因此,在高层建筑的早期阶段进行配电设计时,应高度重视,避免出现质量问题和安全隐患。具体而言,高层建筑供电设计是一个系统的、专业性强的工作,它主要是基于对该高层建筑的特点、内部结构等建筑的实际情况,规划整个建筑的线路布局和供电系统,控制他们的电力负荷水平,将所有的用电设备、供电设备、配电设备等完美的结合到一起,使之形成一个稳定的电力供应系统,有效发挥各个系统、设备和线路的作用,保证配电系统的正常运行,而后将所有的线路设备、电力参数、设备的安装位置和数量、规格等展示在图纸之上,以供实际安全工作进行参考。 二、供配电设计的要求 现代的高层建筑多为集多种功能为一体的综合建筑,比如居住、办公、娱乐、购物,甚至是生产工作,其供电环境也非常复杂,所配合的用电设备更是五花八门,常见的有空调系统、照明系统、消防系统以及家居用电、办公用电等等。因此,在进行供配电设计的时候,必须要保障线路的布局可以满足不同设备的用电需求,在电压等级的分类方面,需要考虑不同楼层可能的使用性质,采用专业的电源线,保证供电稳定和用电安全。此外,还需提高整个建筑的用电效率,尽可能减少电力损失,做到提高效率、节约能耗。 三、供配电设计的原则 (一)系统优化原则 在设计高层建筑的供配电系统时,应当最大限度的贴合高层建筑的结构等建筑因素,发挥建筑本身的优势,这样可以节约电气系统的建设资金,在整个设计过程中,还应贯穿节能理念。首先一点就是,供配电系统的适用性能必须强大。也就是说可更好的满足用电设备对于电能质量的要求、负荷容量的要求和安全运行时的稳定性要求等,必须保证电气设备能够很好的控制电量,最终目的就是让电气设备的功能得到最大的发挥。然后是需要考虑供配电系统的安全可靠性。在安全性方面,必须设计必要的防雷设备,高层建筑高度高,容易遭受雷击,为全面保障电气系统的安全,必须要进行防雷设计。此外,根据建筑的防火的等级设计,考虑火灾情况下的救援需求、潜在的火灾险情等因素,区别普通用电和应急用电,保障突发情况下,能够保障必要设备的运行和照明需求。 (二)高效运行原则 在设计过程中,应当尽量减少电力损耗,尽可能的缩短拉线距离,必要位置需使用直径较大的电线,提高线路的使用寿命,这同时也是确保供配电安全的需要。其次,应尽量保障维修检修方便、简单,缩减维修保养费用,最大限度发挥资源的使用效率。 (三)合理调节负荷原则 各项供配电参数的设计必要保证科学合理,理性的调整负荷参数,避免出现低负荷运行或超负荷运行。设备的使用和技术的选择,应当能够起到节约能耗的作用,同时又要保持整个电气系统负荷均衡。 四、供配电系统设计 (一)确定负荷等级和负荷容量 确定建筑的负荷量等级应当依照标准的方式进行,具体操作步骤如下:一级负荷包括了消防电梯、疏散电梯和地下室的应急照明灯等设备。二级负荷包括当舌泵电力和客户使用的电梯电力。三级负荷就是刨开一级负荷和二级负荷之外的所有电负荷。依据负荷三种级别不同的适用范围,可以大致的把电力负荷划分为居民用电和商业用电两种类型。居民用电主要囊括了生活用电(如电视、用电厨具、热水器等等)和照明用电等内容,这类用电应分配给居民变电配置房进行供配电管理。商业用电项目则主要包括的地下室供电、商场供电、售楼中心等内容,这些位置的供电则分配给商业变电房进行供配电管理。对于负荷容量的计算则通常使用单位容量法与负荷密度法进行。 (二)变电设备所布局设计 变电设备所主要用于管理变电设备的运行,容纳一些必要的操作和监控设备。变电设备所位置与数量的设计需要严格按照负荷容量的计算结果进行。高层建筑的变压器一般采用容量在75%-85%之间设备,将低压线路的供电半径控制在200m的范围内,对于电容量大于500KW的供电情况,则需要将配供电的相对距离控制在200m以上,并且需要增加变电设备所的数量。一般来说,高层建筑一层的商用价值非常高,所以会在负一层设置变电配置所,这样同时满足了一层和负一层的复杂用电需求。 (三)高低电压的结线和运行方式 针对现代高层建筑的建设特点和结构形式,及其复杂的供电需求,笔者认为,可以按照如下的高低电压结线和运行方式:高低压线选择一路进线方法,结线则采用母线单线运行方式;变压器的低压侧部分则采取单母线分段结线运行方式,这样一来,每一台变压器都有了一

高层建筑电气设计要点浅析(标准版)

高层建筑电气设计要点浅析 (标准版) Safety work has only a starting point and no end. Only the leadership can really pay attention to it, measures are implemented, and assessments are in place. ( 安全管理 ) 单位:______________________ 姓名:______________________ 日期:______________________ 编号:AQ-SN-0761

高层建筑电气设计要点浅析(标准版) - 摘要:随着我国经济建设的飞速发展,我国房地产市场也有了很大进步,住宅建设高速增长尤其是以成片开发的住宅小区为主,以多层、小高层住宅组团分布并配以会所、广场、健身场所、超市、幼儿园、学校等完善的配套设施。 关键词:住宅建筑;电气设计;配电设计 引言 随着建筑智能化水平的不断提高,高层建筑电气设计增加了很多弱电部分系统,包括数字电视系统、综合布线系统、背景音乐系统,保安监控系统,电脑的管理系统等。弱电设备占基建投资比率越来越高,所以设计好弱电各个系统,对于节约投资、提高智能化水平都有非常重要的意义。

一﹑高层建筑电气设计的特点 与高层建筑电气关联的用电设备品种繁多。室内、楼梯过道、安全照明等电器照明设备;货梯、客梯等电梯设备;生活水泵和消防泵等给排水设备;冷却塔风机以及水机组等制冷设备;引风机和鼓风机等锅炉房设备;排风机、电冰箱等厨房设备;包括送风机、回风机、风机管盘在内的空调系统送电设备;包括正压风机、排烟风机等在内的消防设备;另外,不同用处的高层建筑在用电量上也存在差别,不过总的来说耗电量比较大。再加上高层建筑的消防用电、客梯电力、应急照明等还要有分别独立的电源。 二﹑高层建筑电气设计的主要内容 (一)用电负荷的计算 高层建筑供电设计的重要参数依据就是电力负荷,其计算的准确程度对选择合理设备并确保电力安全可靠的运行,都能起到重要作用,并发挥节能功效。一般用电负荷的计算方式主要采取负荷密度法与需要系数法。 (二)高低压配电系统的设计

浅析住宅照明电气插座及其回路设计

浅析住宅照明电气插座及其回路设计探讨 摘要:现代住宅中插座的选型、布置位置、数量和安装高度都直接关系到住户今后的使用效果,是现代住宅电气设计中十分重要的内容。如果电气插座设计还按照以前的做法,墨守成规的话,已经跟不上时代的步伐。现代建筑电气设计人员十分有必要对插座这个小小的电气装置元件引起足够重视。 关键词:电气插座回路设计住宅 电气插座布置 插座这个小小的电气装置元件,往往容易被人忽视,但在现代住宅中却随处可见,不管是在客厅、卧室、书房,还是在厨房、餐厅、卫生间,人们都要使用它,甚至阳台都忘不了装一个插座,以备它用。 现代生活水平不断的提高,人们对住宅电气装置的要求也越来越高,人们不再满足于照明、风扇、洗衣机、电冰箱、彩电等电气设备带来的方便,而更加热衷追求音响、空调、大屏幕彩电、电脑、电话带来的享受。随着当今知识经济、信息时代的到来,可视电话、电子购物、家庭办公等智能化住宅建筑将不断涌现。这些电能、信息的传递除通过电线、电缆外,还必须通过插座这个小小电气装置元件输送给用电设备或信息终端。可见,插座的种类和数量在现代住宅中呈日益增长的趋势。所以,现代住宅中插座的选型、布置位置、数量和安装高度都直接关系到住户今后的使用效果,是现代住宅电气设计中十分重要的内容。如果电气插座设计还按照以前的做法,墨守成规的话,已经跟不上时代的步伐。现代建筑电气设计人员十分有必要对插座这个小小的电气装置元件引起足够重视。 然而,在现实的住宅电气中,往往看到住宅建成后,住户搬进来之前,都要对原设计的电气线路进行很大的改造,这里增加一个灯,那里增加一个多用插座和电话插座,那里还要增加一个空调插座和电视插座,增加最多的就是插座,到处凿墙打洞,对整个建筑物的结构造成很大破坏,有的甚至留下安全隐患。进行线路改造者大部分又不是电气专业安装人员,时常造成烧坏家电、短路、断路、等现象,对整个建筑物的配电系统造成损害。出现上述现象的原因是多方面的,但设计不尽人意, 也是一个重要方面。

探究现代建筑电气设计的特点及发展_0

探究现代建筑电气设计的特点及发展 如今我国的建筑工程电气领域发展得越来越好,但仍存在很多的问题,研究解决问题也是对未来信息化时代建筑工程电气领域的发展有一定实际的意义。利用电气工程能够促使建筑工程完成得更加全面。本文主要对现代建筑电气设计的特点及发展进行了分析研究。 标签:建筑工程;电气设计;技术问题;未来发展 引言 我国的科技水平和社会经济发展都在飞速前进,进而对现代建筑电气设计也提出了新的要求,需要将人性化、智能化和实用性结合起来,需要不断创新和完善设计水平才能满足现代建筑对电气设计的要求。电气设计需要以安全性、经济性和实用性为基本原则,还要充分考虑现代科技和信息技术的发展,将新型技术融合到电气设计中,也是必然的发展趋势,设计中需要充分将以上特点和发展趋势结合起来,才能不断提升我国现代建筑电气设计的整体水平。 1现代建筑中电气设计的必备特点 1.1人性化 现代建筑必须要迈向人性化,首先就需要电气设计趋于人性化,将这个理念始终贯穿于电气设计中,才能满足现代建筑的需求。电气设计要满足建筑的使用需要,包含照明和防盗等,还要满足人们对空间的需求,并要保持空间内的空气流通,便于温度的传递等。还要考虑外部设计,内外都需要符合设计理念并满足人性化要求。 1.2经济化 现代建筑电气化设计需要充分考虑经济化,不可做无谓的浪费,充分考虑造价和成本,结合考虑使用效率等因素,以节约成本和提升使用效率为设计的重要参考标准,以节约环保为原则。 1.3难度大 现代建筑电气设计面临着越来越多的挑战,随着现代建筑的发展和人们越来越高的要求,电气设计需要充分考虑各个方面的因素,还要对建筑的运行进行整体筹划,确保使用中能够协调运作,同时还要确保利益最大化。现代建筑需要多样化和人性化,这不但需要设计创新,还增加了复杂度,这些都是电气设计需要克服的新困难。 2电气设计技术性问题

超高层建筑电气设计研究

超高层建筑电气设计研究 发表时间:2016-12-08T13:37:33.297Z 来源:《基层建设》2016年22期作者:蔡振芳 [导读] 摘要:本文结合工程案例,对超高层建筑电气设计进行研究,供同行借鉴参考。 身份证号码:44030619841010**** 摘要:本文结合工程案例,对超高层建筑电气设计进行研究,供同行借鉴参考。 关键词:超高层;电气设计 一、工程概况 该超高层总共46层,地下有2层,集办公楼、裙房为一体的综合性建筑,地上5层裙房商业,1栋180m超高层办公、1栋高层办公楼,地下室为设备房及车库等。 二、供配电系统 (1)负荷等级、负荷计算及供电电源 ①本工程为超高层综合楼,用电负荷等级划分详见表1 表1负荷等级分类表 ②供电电源 电源由供电局提供两独立回路10KV高压电源(来自两个区域变电站)。本工程开闭所设在地下一层,供电局提供的高压电缆先引入开闭所,再从开闭所引两路10KV电源至变配电室。变配电室10KV主接线采用单母线分段的接线方式,系统设有分段母线联络开关,两路10KV电源同时供电,互为备用,当其中一路电源因故障停电时,由另一路电源供给全部一、二级负荷。 低压主接线采用单母线分段的接线方式,两台变压器为一组,互为备用,分别设有母线联络开关,两只低压进线开关及母联开关两通一断,采用电气、机械联锁。 为保证消防等用电设备的供电可靠性,该项目中设置了柴油发电机作为工程中的第三电源,以确保消防等重要负荷的供电可靠性。 (2)供电变配电所设置 超高层建筑供电变电所的设置按照《民用建筑电气设计规范》(JGJ16—2008)第 4.2.1;4.2.2;4.2.3条所确定的原则设置。 由于本工程的主要用电负荷如中央空调机房、水泵房等均设在地下二层,裙房有大型的超市、电影院。超高层地上建筑高度为180m,16层及28层为避难层,避难层及屋顶设计有空调机房及水泵房。为使变压器尽量靠近负荷中心,综合供电半径、技术、经济指标分析。本工程设计中将变配电所设在地下一层,而将柴油发电机房设在变配电机房附近。大型超市应商家的需求在地下室独立设置了变配电房。28层避难层设置了变配电房。在避难层设置变电所应考虑变压器的垂直运输通道以及设备对楼板荷重的影响,单台变压器的容量不宜超过800KVA。 (3)供电变压器选择 超高层建筑供电变压器的选择,应根据《民用建筑电气设计规范》(JGJ16—2008)第4.3.1~4.3.3条的规定选择。当单体建筑规模比较大,供电负荷较大时,有可能选择多台大容量供电变压器,多台变压器宜组成每两台成一组的组合。低压供电母线为“两进线-母联”的接线形式,平时变电所的变压器均分列运行,当其中一台变压器故障或检修时,则可以切除部分空调等非保证负荷,闭合低压母联开关,由另一台变压器负担大楼的消防、照明等重要负荷的供电。所有消防设备、重要机房均采用双回路放射供电,并按规范要求在末端设ATS自动切换装置。对于空调等季节性负荷,根据实际的设备容量,设计中将该部分负荷集中设置,在过渡季节,可以根据需要切除部分负荷,停用相应的变压器,以降低变压器损耗,达到节能的目的。 综上述分析,在地下一层设置3个变配电室,1#变配电室变压器总装机容量为7300KVA,采用3台1600KVA和2台1250KVA干式节能型电力变压器,供超高层办公与地下室及商业用电;2#变配电室变压器总装机容量为2800 KVA,采用2台1000KVA和1台800KVA干式节能型电力变压器,供高层办公与地下室及商业用电;3#变配电室变压器总装机容量为3200KVA,采用2台1600KVA干式节能型电力变压器供超市用电;在28层避难层处设1个变配电房,变压器总装机容量为3200KVA,采用4台800KVA干式节能型电力变压器。整个建筑物的总装机容量为16500KVA。变压器接线组别DYn/11,10KV/0.4KV,带强制风冷系统及温控温显装置,保护等级为IP40。 现行大型的商业综合体已经从以往的纯购物模式,转变成体验、娱乐、餐饮为一体的模式。由于大量的餐饮存在,故本设计中商业的容量取值相对大些。 (4)应急柴油发电机组设置 超高层建筑有大量的一级负荷,考虑设置柴油发电机组作备用电源。备用电源宜靠近各区域配电中心设置。该工程设置柴油发电机组,一种情况是将其作为用以保证二路市政供电故障同时火警又发生时有关消防设备的供电。其中消防设备包括消控中心、消防水泵、消防电梯、排烟风机、正压风机、火灾自动报警、漏电火灾报警、自动气体灭火系统、防火卷帘门、应急照明、消防潜水泵等。另一种情况是将其作为用以保证二路市政供电故障而停电时,对一级负荷和某些重要的二级负荷的供电。设计时柴油机组容量的选择正是按以上两种情况进行比较,且需对发电机进行电压降校验选,从而确定发电机组容量的依据。经计算,同时应甲方管理需求,于本工程地下一层1#变配电设置一台容量为1200KW柴油发电机作为自备应急电源,超市独立设置一台800KW发电机作为自备应急电源。机组在两路市电停电后30s内自起动投入供电,其相序与市电相序一致。发电机与市电互锁,以防倒送电。 三、电缆电线选择和敷设 超高层建筑干线电力线路的选型和敷设方式是电气设计中比较烦琐的问题。由于封闭式母线载流量大,对于大容量配电干线而言,封闭式母线的应用就更能体现它的优势,故本工程的普通电源、空调动力大容量用电干线均采用封闭式母线。根据《民用建筑电气设计规范》(JGJ16-2008)第7.4.3条导体敷设的环境温度要求,在封闭的强电间发热量大,会造成导体载流量下降,故暖通专业应予考虑适当排风。配电干线在变配电室内段的敷设用开敞式电缆托盘,变配电室到电气竖井间段采用封闭式防火电缆桥架敷设,在电气竖井内的敷设全部采用电缆明敷固定在阶梯式电缆梯架上。这样,就比较有效地解决了安装施工及上述问题,也方便于今后的检修和维护。在楼层间的分支干线导线敷设根据所配设备的消防负荷等级选择防火类型,并尽可能地采用钢管暗敷在墙壁和楼板内,明敷防火线路在外套保护钢管上喷涂防火涂料。各层电气竖井内的楼板孔洞和各处墙壁上的电气安装孔洞,在设备安装施工的后期一定要用防火胶泥等防火材料严

浅探住宅照明电气插座及其回路设计

浅探住宅照明电气插座及其回路设计关键字:住宅照明;电气插座;回路设计 摘要:插座这个小小的电气装置元件,往往容易被人忽视,但在现代住宅中却随处可见,不管是在客厅、卧室、书房,还是在厨房、餐厅、卫生间,人们都要使用它,甚至阳台都忘不了装一个插座,以备它用。 keyword: residential lighting; electrical socket; circuit design abstract: the socket this small electrical devices components, often ignored, but in the modern house but is everywhere, whether in the sitting room, bedroom, study, or in the kitchen, restaurant, toilet, people have to use it, and even the balcony all unforgettable pack a socket, ready to use it. 中图分类号:s611文献标识码:a 文章编号: 现代生活水平不断的提高,人们对住宅电气装置的要求也越来越高,人们不再满足于照明、风扇、洗衣机、电冰箱、彩电等电气设备带来的方便,而更加热衷追求音响、空调、大屏幕彩电、电脑、电话带来的享受。随着当今知识经济、信息时代的到来,可视电话、电子购物、家庭办公等智能化住宅建筑将不断涌现。这些电能、信息的传递除通过电线、电缆外,还必须通过插座这个小小电气装置元件输送给用电设备或信息终端。可见,插座的种类和数量在现

浅析高层建筑电气供配电系统设计

浅析高层建筑电气供配电系统设计 摘要:随着现代社会的发展,建筑物的规模不断扩大,其内各种电气设备的使用日趋增多,尤其是计算机网络信息技术的普及,建筑物越来越多采用各种信息化的电气设备。以下结合相关规范及工程实际情况,对目前高层建筑供配电系统设计进行了分析,并提出了自己的一些见解。 关键词:高层建筑;供配电系统;设计 引言:一般高层建筑的供配电系统设计的目的,就是要采用一切可能的技术手段,在数量上和质量上满足各种用电设备在正常工作状况下的不同用电要求,保证供电的安全和可靠。仪器也在不断进步,其中高、精、尖仪器比例不断增加,这类仪器对电能质量要求较高,如何才能满足不同电器的用电要求呢,供配电线路的设计相当重要。 1.供配电系统的重要性 供配电系统的安全可靠性在电气设计时是至关重要的一环。电力负荷根据对供电可靠性的要求及中断供电的损失和影响程度分为一级负荷、二级负荷、三级负荷。一类高层建筑的消防控制室、消防水泵、消防电梯、火灾自动报警、自动灭火系统、应急照明等消防设备为一级负荷,还有柴油发电机房送风机、专用变电所所用的送、排风机及消防水泵房、消防电梯所用的污水泵等设备应与消防设备等级一致。一级负荷中特别重要负荷,除有两个电源外,还必须增设应急电源和不间断电源。为保证对特别重要负荷的供电,严禁将其他负荷接入应急供电系统。 2.高层建筑供配电设计应遵循的基本原则 由于高层建筑的特殊性,因此,在对高层建筑的供配电系统进行设计的过程中,必须严格遵

循一定的原则。具体来说,主要包括以下内容: (一)可靠性原则。在民用高层建筑中,由于使用人员密集,涉及面广,因此,供配电系统设计必须坚持安全性与可靠性。在规划设计的过程中,应当首先科学分析实际用电负荷等级,在此基础上保证供配电系统能够在任何运行方式下都可以持续性提供电力保障,从而确保电力供应的安全可靠。 (二)简洁性原则。由于高层建筑电气设备较多,因此在日常使用以及维护的过程中,供配电系统的线路设计要追求简单、清晰,尽量避免过多的电气设备。同时,电气设备及线路的设计要方便使用、易于操作。只有这样,才能充分保障供配电系统的安全运行,并且也有助于对各种故障进行及时处理。 (三)保障安全性原则。在民用高层建筑中,由于电气设备以及功能需求较多,因此,在日常工作过程中,应当充分保证操作人员在日常工作以及在检修维修过程中的安全性。 3.供配电系统的设计 供配电系统是建筑电气的基本系统,它对电能起着接受、变换和分配的作用,向各种用电设备提供电能。 3.1 电力负荷分级及其供电可靠性要求 电力网上用电设备所消耗的功率,称为用户的“用电负荷”或“电力负荷”。用户供电的可靠性程度,是由用电负荷的性质来决定的。划分负荷等级,需要看建筑物的类别和用电负荷的性质。按《民用建筑电气设计规范》规定,对用电负荷等级划分为三类: 3.1.1 一级负荷 中断供电将造成人员伤亡者;中断供电将造成重大政治影响者;中断供电将造成重大经济损失者;中断供电将造成公共场所秩序严重混乱者。 3.1.2 二级负荷