四川水电站地下厂房施组设计

四川水电站地下厂房施组设计
四川水电站地下厂房施组设计

目录

第一章综合说明.................................................. 第1节工程概述.................................................. 第2节合同项目和工作范围........................................ 第3节主要工程量................................................ 第4节合同控制性工期要求........................................ 第5节本投标书编制依据和原则.................................... 第二章施工总体规划.............................................. 第1节工程概述.................................................. 第2节施工重点、难点............................................ 第3节施工技术规划.............................................. 第4节施工队伍及设备的组织...................................... 第5节施工准备及临建设施........................................ 第6节施工总体程序安排.......................................... 第7节本工程施工目标............................................ 第8节施工指导思想.............................................. 第三章施工总布置及辅助企业...................................... 第1节编制原则及依据............................................ 第2节业主提供的条件............................................ 第3节施工临建设施的布置规划.................................... 第4节施工风、水、电及通讯系统.................................. 第5节施工通风系统的布置........................................

第7节砼拌合站.................................................. 第8节施工生产设施.............................................. 第9节办公及生活营地............................................ 第10节弃碴场规划与环保......................................... 第11节污水处理................................................. 第四章施工总进度计划............................................ 第1节编制依据及原则............................................ 第2节主要控制性工期............................................ 第3节施工总进度安排............................................ 第4节主要施工强度.............................................. 第5节施工关键线路.............................................. 第6节关于施工总进度的说明...................................... 第7节保障工期措施.............................................. 第五章施工期水流控制............................................ 第1节施工期导流规划............................................ 第2节导流标准.................................................. 第3节道路布置.................................................. 第4节围堰结构.................................................. 第5节导流建筑物施工............................................ 第6节施工期排水................................................ 第7节围堰拆除.................................................. 第8节防洪渡汛..................................................

第10节资源配置................................................. 第六章地下厂房工程施工.......................................... 第1节工程特性.................................................. 第2节施工规划.................................................. 第3节洞内布置.................................................. 第4节开挖施工方法.............................................. 第5节锚喷支护及排水孔.......................................... 第6节砼施工.................................................... 第七章调压井工程................................................ 第1节施工特性.................................................. 第2节施工规划及程序............................................ 第3节洞内临时布置.............................................. 第4节土石方明挖................................................ 第5节石方洞挖施工.............................................. 第6节支护工程施工.............................................. 第7节混凝土工程施工............................................ 第8节主要施工机具投入.......................................... 第八章引水隧洞及压力管道工程.................................... 第1节施工特性.................................................. 第2节施工规划及程序............................................ 第3节洞内布置.................................................. 第4节洞挖施工..................................................

第6节砼施工.................................................... 第7节资源配置.................................................. 第九章尾水系统工程施工.......................................... 第1节工程特性.................................................. 第2节施工临时布置.............................................. 第3节施工规划.................................................. 第4节土石方明挖施工............................................ 第5节尾水洞洞挖施工(含尾水管、尾水联接洞) ................... 第6节砼工程施工................................................ 第7节土石回填施工.............................................. 第8节质量安全保证措施.......................................... 第9节工程进度保证措施及成本控制................................ 第十章地下厂房辅助洞室施工...................................... 第1节工程特性.................................................. 第2节施工规划及程序............................................ 第3节施工布置.................................................. 第4节施工测量.................................................. 第5节洞挖施工.................................................. 第6节锚杆支护施工.............................................. 第7节喷砼施工.................................................. 第8节排水孔施工................................................ 第9节砼工程施工................................................

第10节工程质量、安全、进度及成本控制........................... 第11节支洞封堵................................................. 第12节主要施工机械设备表....................................... 第十一章开关站工程施工.......................................... 第1节概述...................................................... 第2节施工程序.................................................. 第3节开挖工程施工.............................................. 第4节砼施工.................................................... 第5节砖墙砌体工程施工.......................................... 第十二章建筑与装修.............................................. 第1节施工特性.................................................. 第2节屋面工程.................................................. 第3节地面工程.................................................. 第4节抹灰工程.................................................. 第5节门窗工程.................................................. 第6节装饰金属件及特殊零件...................................... 第7节建筑给水排水及处理系统.................................... 第十三章基础处理工程施工........................................ 第1节概述...................................................... 第2节钻孔灌浆施工.............................................. 第3节预应力锚索................................................ 第4节高喷防渗墙施工............................................ 第十四章压力钢管的制造和安装....................................

第1节工程概况.................................................. 第2节临时设施布置.............................................. 第3节主要施工设备.............................................. 第4节压力钢管.................................................. 第5节焊接...................................................... 第6节水压试验.................................................. 第7节钢管起吊、运输方案........................................ 第十五章闸门及启闭机安装........................................ 第1节合同范围.................................................. 第2节设备的提供................................................ 第3节责任...................................................... 第4节主要提交资料.............................................. 第5节闸门及启闭机安装技术条件.................................. 第6节安装前的准备工作及应具备的资料............................ 第7节焊接...................................................... 第8节涂装...................................................... 第9节设备的运输及起吊.......................................... 第10节闸门的安装............................................... 第11节质量检查和验收........................................... 第12节完工验收................................................. 第十六章原型观测................................................ 第1节概述...................................................... 第2节埋设组织..................................................

第3节仪器设备的采购和验收...................................... 第4节仪器安装埋设前的准备工作.................................. 第5节施工方法.................................................. 第6节质量保证措施.............................................. 第十七章施工测量、试验与检验.................................... 第1节施工测量.................................................. 第2节爆破试验.................................................. 第3节原材料试验检测............................................ 第十八章施工现场组织机构........................................ 第1节组织机构设置.............................................. 第2节主要职责和工作内容........................................ 第3节施工人员配置.............................................. 第十九章质量保证措施............................................ 第1节合同的质量控制目标........................................ 第2节质量方针和质量目标........................................ 第3节质量管理体系.............................................. 第4节质量管理措施和办法........................................ 第5节质量体系保证措施.......................................... 第6节主要项目质量工作程序...................................... 第7节分项工程质量保证措施...................................... 第二十章施工安全保证措施........................................ 第1节安全管理目标.............................................. 第2节安全生产方针..............................................

第3节安全管理体系.............................................. 第4节安全管理措施及办法........................................ 第5节施工现场安全措施.......................................... 第6节重点项目安全保证措施...................................... 第7节重要工序的安全措施........................................ 第二十一章文明施工措施.......................................... 第1节文明施工的目标............................................ 第2节文明施工的组织机构........................................ 第3节文明施工管理.............................................. 第4节文明施工的实施办法........................................ 第二十二章环境保护保证措施...................................... 第1节环境保护的目标............................................ 第2节环境保护保证体系.......................................... 第3节环境保护组织措施.......................................... 第4节环境保护的具体措施........................................ 第二十三章施工信息化管理........................................ 第1节施工信息化管理的目标...................................... 第2节施工信息化管理的基本内容.................................. 第3节施工信息管理系统形成及运行................................ 第4节施工信息管理系统维护及安全运行措施 ....................... 第5节人员配备.................................................. 第6节竣工资料及施工记录的管理.................................. 第二十四章施工期内外关系协调....................................

综合说明

第一节工程概述

工程概况

**水电站位于四川省**县境内东河上,主要由拦河闸坝首部枢纽、引水系统和地下厂房枢纽三部分组成。厂址距**县城约,**县城至雅安72km,工程区内有公路通过,对外交通较方便。电站共装机3 台,单机容量65MW,总装机容量为195MW。本工程为三等中型工程,主要建筑物按3 级设计。本标工程包括引水隧洞、调压室系统、压力管道系统、地下厂房系统和开关站等工程的土石方明挖、石方洞挖及支护、混凝土浇筑、回填固结接触及帷幕灌浆、压力管道钢管制作安装、主变室及尾水出口闸门安装、厂房建筑及装修等项目的施工。

引水隧洞布置在左岸,总长,进口底板高程1326m。引水隧洞全部采用马蹄形断面。在Ⅱ类和Ⅲ类围岩段采用喷砼和挂网喷砼防护,设计洞径为,底板同衬砌厚20cm,喷砼厚10cm;在地质条件较差的Ⅳ类围岩段采用双层钢筋砼衬砌加固结灌浆和回填灌浆,设计洞径,衬砌厚度40cm;遇断层破碎带、过沟处上覆岩体厚度较薄等地段,则采取加大钢筋砼衬砌厚度、或采用钢内衬外包钢筋砼等方案处理。7#施工支洞布置在调压室下游,除作为本标引水隧洞的施工通道外,还兼作调压室和压力管道的施工通道。

调压室位于引水隧洞的末端,距地下厂房水平距离约300m,水流在调压井底采用单洞单管一进一出的布置方案。调压室为地下埋藏式、水室式调压

室,由上室交通通气洞、上室及竖井组成。竖井总高,其中主井内径10m、高,连接管内径,高;上室长113m、横断面为×渐变为×、底板高程~。压力管道为埋管,由上平段、斜井段、下平段组成,最大单根长度。主管段管径D=,均布置钢衬,钢衬材质16MnR,厚度20~36mm,钢管外回填砼厚60cm。主管末端布置2 个“卜”型月牙肋岔管为三机供水。

地下厂房系统由主副厂房及安装间、主变室(兼尾闸室)、母线洞、尾水系统交通洞、通风洞、出线洞(兼排风洞)、排水洞等组成。主副厂房及安装间开挖尺寸72××(长×宽×高,下同),布置有岩壁吊车梁;主变室开挖尺寸为××(长×宽×高);进厂交通洞总长185m,自安装间右端墙进厂,开挖尺寸8×8m;尾水主洞总长213m,为无压洞,最大开挖尺寸×,尾水洞兼辅助进风洞,向主变室供风;出线洞总长203m,连接主变室及洞外GIS 开关站,开挖尺寸×;出线洞兼作排风洞;通风洞位于厂房上游侧,为发电厂房进风通道,进风洞总长183m,兼事故交通洞,开挖断面×。

本标段将于2005 年4 月中下旬开工,2008 年7 月20 日工程全部竣工。**水电站工程总工期为39 个月。

水文气象

**河流域属亚热带季风气候区,冬季受西风带气流影响,寒冷少雨,夏季受东南暖湿气流控制,温湿多雨,春季气温回升迟缓,多低温天气和春旱,秋季低温天气明显,具有冬冷、春干、夏凉、秋润的特点。流域内由于地势高差悬殊,因此立体气候显着,海拔1700m 以下属亚热带气候,1700~3500m 呈现山地温带气候,3500m 以上为山地寒带气候。气温由下游至上游随海拔高程升高而逐渐递减。工程所在地**(▽1010m)多年平均气温°。

本流域降水量具有南面大,北面小,山腰大,河谷小的特点。多年平均降水量**为,**为。降水多集中在5~10 月,占全年的85~90%。本流域夜间降雨较多,有夜雨昼晴的特点。

**河的径流主要来自降水,其次是地下水和高山融雪补给,径流具有丰沛稳定河年季变化小的特点。径流的年内分配与降雨年内分配基本相应,丰水期(5~10 月)多年平均流量s,占年径流的%,枯水期(11 月~翌年4 月)多年平均流量s,坝址多年平均流量 m3/s。

根据分期设计洪水,汛期(6 月~10 月5 日)、汛后过渡期(10 月、11 月)、非汛期(12 月~3 月)、汛前过渡期(4 月、5 月)。

表 **河厂址径流设计成果表流量:m3/s

表 **水电站厂址分期洪水成果表流量:m3/s

表 **电站厂址水位~流量关系曲线流量:m3/s

工程地质

厂房区岸坡地表植被发育,崩坡积覆盖广泛,基岩露头少。厂房区无常年地表流水,地下水主要为基岩裂隙性潜水河覆盖层孔隙潜水。厂房地段的地下水主要受大气降水补给,排泄于东河。

调压室工程地质条件

调压室穹顶水平埋深90m,垂直埋深100m。调压井地段地面坡度45~55°,地表下面积基岩裸露,地层岩性为震旦系厚层~中厚层白云岩、白云质灰

岩及薄层炭质(硅质)白云岩,局部少量炭质页岩及硅质条带,白云岩产状多变,总体倾角较缓(一般均小于30°)。岩体中断裂构造较发育,发育的裂隙主要有NNE、NE~NEE 及NWW 三组,其中以倾向NW(岸外)的高角度为主。调压室顶部岩体完整性差,为Ⅳ类堰体;井身段大部分围岩为Ⅲ类,局部为Ⅳ类。

压力管道工程地质条件

压力管道约在管轴线1100m 高程以下位于侵入岩体中外,其余均位于白云岩中。白云岩中围岩总体为Ⅲ类,局部为Ⅳ类。白云岩与侵入岩接触带约在管轴线1110m 高程左右,倾角约25°;接触带岩体较破碎,属Ⅳ~Ⅴ类围岩;侵入岩中围岩以Ⅱ类为主,局部类,断裂破碎带及其影响带为Ⅳ类。

地下厂房区工程地质条件

地下厂房埋深180~250m,山体基岩为澄江~晋宁期第二期辉长岩、第三期闪长岩、第四期花岗岩组成的侵入杂岩,总体破碎程度较高、完整性相对较差。通过地下洞室位于岩体中的结构面规模较大的有F3(f9)、F7(f15)、F5(f21)、f25、f27、f28 等,控制各不同部位的稳定,规模相对较小的结构面有f1、f2、f3、f4、f19、f20、f22、f24、f26 等,对局部稳定有影响。主副厂房、安装间及主变(尾闸)室围岩总体为Ⅱ类,局部受断层切割影响为Ⅲ~Ⅳ类;尾水洞洞身段基本属Ⅲ类围岩,局部断层带及影响带属Ⅲ~Ⅳ类围岩,出口段围岩为Ⅳ类,明渠段基础为漂(块)石砂卵砾石;进厂交通洞、通风洞、出线洞等洞身段岩体完整性及裂隙发育规律与厂房、尾水洞基本相同。

对外交通

本工程地处**河支流东河上,首部枢纽~**县城现有公路相通,**县城至厂、坝区均为三级公路,砼路面。**县城~(雅安)飞仙关为三级公路,砼路面,从飞仙关起为108 国道。其中,雅安~成都有成(都)雅(安)高速公路相通,对外交通方便。

首部枢纽距**县城公路里程为,厂区距**县城公路里程为。**县城距雅安市为72km,距成都为218km。

第一节合同项目和工作范围

主体工程项目和工作内容

(1)引水隧洞

本标包括引水隧洞(隧洞桩号18+~18+)。含石方洞挖、砼浇筑、喷砼、锚杆制安、钢筋制安、回填灌浆、固结灌浆等项目的施工;

(2)调压室

调压室由上室交通通气洞、上室及竖井组成,含土方开挖、石方洞挖、石方井挖、砼浇筑、喷砼、锚杆制安、钢筋制安、回填灌浆、固结灌浆等项目的施工;

(3)压力管道

完成压力管道的石方洞挖、砼浇筑、喷砼、锚杆制安、钢筋制安、钢管制造和安装、回填灌浆、固结灌浆以及帷幕灌浆等项目的施工;

(4)地下厂房系统和开关站

本标包括地下厂房系统中的主副厂房、主变室、母线洞、主变运输洞、尾水洞和尾水出口(含尾水闸、尾水渠、跨渠桥)、交通洞、通风洞、出线洞(排风洞)等建筑物以及洞外通风楼、排风楼、GIS 开关站等建筑物。

主要施工项目包括:土石开挖、石方洞挖、砼浇筑(含二期砼)、喷砼、锚杆制安、钢筋制安、土石回填、圬工、排水、闸门及启闭机的安装、厂房建筑及装修等项目的施工。

(5)原型观测

观测设备的验收和保管;仪器的率定、安装、维护及施工期的观测、数据分析。

(6)与机电安装标的配合工作

临时工程项目和工作内容

(1)施工期水流控制

尾水渠出口施工围堰设计、施工、维护及拆除,施工期的基坑排水、安全渡汛、施工区域排水;

(2)7#、8#施工支洞的维护、排水及支洞封堵,7#支洞的排水通气洞施工;

(3)至本标各工作面的施工主干线道路由业主提供,由本标负责维护和管理;

(4)现场施工临时设施

为满足现场施工所需的临时供电、供水、供风、砼拌制、钢筋加工、模板加工、机械修配加工、汽车保养、金属结构拼装、仓库、办公及福利设施等临时设施均由施工单位自行设计、施工、维护和管理。其中施工用电由业主提供10kv 电源接线点,从该电源接线点上接线,从该接线点至施工现场的供电线路、降压变压器及其配电装置均有承包人自行设计、架设、安装与维护;

(5)为满足本标工程施工需要,必要的附属设备和其它临时设施;

(6)施工场地征用、搬迁和移民安置由业主负责,但原有建筑物的拆除由施工单位负责。

业主承担的工程项目和工作内容

(1)本工程所需木材、水泥和钢筋(材)、砂石骨料由业主以不变价格供给,提供地点为承包人工地主仓库;

(2)工程区施工主干线公路;

(3)施工场地的征用、搬迁和移民安置;

(4)永久设备的采购和运输。

第一节主要工程量

表主要工程量表

第一节合同控制性工期要求表要求完工日期表

第一节本投标书编制依据和原则编制依据

(1)根据“四川华能**水电站调压室、压力管道及地下厂房工程招标文件(合同编号:BX/CⅥ)及招标图纸;

(2)现场踏勘及标前会所获得的实际资料;

(3)与本标工程施工相关的现行采用的规范及规定;

(4)我方已承建类似工程成功的施工经验。

编制原则

(1)全面响应招标文件要求,在工期上满足控制性进度要求,在施工布置上充分利用业主指定的施工场地;

(2)充分利用我局现有的机械设备,配备满足施工强度要求的土石方开挖、砼浇筑的设备,并考虑设备的备用和有一定的富裕量;

(3)选择较为先进的施工方案与工艺,满足混凝土施工内部与外观质量要求,满足地下洞室的开挖要求;

(4)配备满足现场施工的测量、试验仪器,建立相应规模的现场试验室,配备相应资质的试验人员,以满足现场试验与质量控制要求。

施工总体规划

第一节工程概述

**电站调压室、压力管道及地下厂房工程包括引水隧洞、调压室系统、压力管道系统、地下厂房系统和开关站等工程的土石方明挖、石方洞挖及支护、混凝土浇筑、回填固结接触及帷幕灌浆、压力管道钢管制作安装、主变室及尾水出口闸门安装、厂房建筑及装修等项目的施工。

调压室位于引水隧洞的末端,距地下厂房水平距离约300m。调压室为地下埋藏式、水室式调压室,由上室交通通气洞、上室及竖井组成。竖井总高,

其中主井内径10m、高,连接管内径、高;上室长113m、横断面为×渐变为×、调压井采用钢筋混凝土衬砌,竖井导井采用LM-200 型反井钻机施工,贯通后调压室上室、调压室通气洞和竖井扩挖石碴均由导井溜碴到井下经7#支洞运输,调压室上室、调压室通气洞和竖井下部小井采用泵送混凝土入仓,调压室竖井上部大井段采用卷扬机吊运砼入仓。

压力管道为埋管,由上平段、斜井段、下平段组成,最大单根长度。压力管道均布置钢衬,钢管外回填混凝土厚60cm。压力管道采用钻爆法施工,其中斜井长283m(不含上下弯段),采用LM-300 型反井钻机钻导井,人工手风钻扩挖成型,斜井及下平段爆破石碴均在下平段通过8#施工支洞运输弃碴。

地下厂房系统由主副厂房及安装间、主变室(兼尾闸室)、母线洞、尾水系统、交通洞、通风洞、出线洞(兼排风洞)、排水洞等组成。主副厂房及安装间开挖尺寸为72××(长×宽×高),布置有岩壁吊车粱;主变室开挖尺寸为××(长×宽×高);进厂交通洞总长185m,自安装间右端墙进厂,开挖尺寸8×8m;尾水主洞总长213m,连接主变室及洞外GIS 开关站,开挖尺寸×;出线洞兼作排风洞。主副厂房及安装间、主变室采用多臂钻和独臂钻分层钻爆施工。

第一节施工重点、难点

施工重点

1、根据我局以前多个地下厂房枢纽施工的经验来看,重点一般都在地下厂房系统,结合本标招标文件分析,本标也不例外。但是由于本标的调压井和尾水系统的控制性工期比较靠前,而厂房和尾水系统又具有很好的施

水电站厂房设计(图文讲解)

水电站厂房设计 第一节水电站厂房的任务、组成及类型 一、水电站厂房的任务 水电站厂房是将水能转为电能的综合工程设施,包括厂房建筑、水轮机、发电机、变压器、开关站等,也是运行人员进行生产和活动的场所。 水电站厂房的主要任务: (1)将水电站的主要机电设备集中布置在一起,使其具有良好的运行、管理、安装、检修等条件。 (2)布置各种辅助设备,保证机组安全经济运行,保证发电质量。 (3)布置必要的值班场所,为运行人员提供良好的工作环境。 二、水电站厂房的组成 (一)从设备布置和运行要求的空间划分 主厂房:布置水电站的主要动力设备(水轮发电机组)和各种辅助设备,设置装配场(安装间)。 副厂房:布置控制设备,电气设备和辅助设备,是水电站运行、控制、监视、通讯、试验、管理和工作的房间。 主变压器场:装设主变压器的地方。水电站发出的电能经主变压器升压后,再经输电线路送给用户。 高压开关站:装设高压开关、高压母线、和保护措施等设备的场所,高压输电线由此送往用户。 此外厂房枢纽中还有:进水道、尾水道和交通道路等。 水电站主厂房、副厂房、主变压器场和高压开关站及厂区交通等,组成水电站厂区枢纽建筑物,一般称厂区枢纽。 (二)从设备组成的系统划分 水电站厂房内的机械及水工建筑物共分五大系统 (1)水流系统。水轮机及其进出水设备,包括压力管道、水轮机前的进水阀、蜗壳、水轮机、尾水管及尾水闸门等。 (2)电流系统。即电气一次回路系统,包括发电机及其引出线、母线、发电机电压配电设备、主变压器和高压开关站等。 (3)电气控制设备系统。即电气二次回路系统,包括机旁盘、励磁设备系统、中央控制室、各种控制及操作设备如各种互感器、表计、继电器、控制电缆、自动及远动装置、通迅及调度设备等直流系统。

引水式电站闸坝枢纽工程设计说明书本科毕业设计

本科毕业设计 水电站闸坝枢纽工程设计说明书 摘要 鱼潭水电站位于四川省某自然保护区境内,系岷江一级支流熊猫河干流上的梯级电站。电站规划装机24MW,为有压引水式开发方案。闸址位于岩谷大桥下游约700m处,该处布臵有引水发电隧洞取水口,经过约2.6km的压力隧洞至调压井,然后接约300m长的压力钢管至规划厂址处获得约46m水头。闸坝左岸有省级干道公路通过,交通方便。熊猫河系岷江右岸支流,全长87.9km,流域面积1742 km2。鱼潭水电站闸址距河口约30km,控制流域面积1467 km2,占全流域的84%。为保护区内水力资源丰富,目前熊猫河干支流上已装机326.8MW,约占其理论蕴藏量的37.5%。XX 电站出线将以110千伏一回送入四川主网,它的兴建不仅可以扩大电网的规模,支援四川主网电力,更重要的是对加速振兴保护区经济,办好自然保护区,保护珍稀动植物有着重大的经济意义和社会意义。此前区内已开发兴建的约6.8MW 小型水电站的电力,除用于区内大量的农副产品加工、保护区研究中心科研用电、农民以电代柴及生活照明外,多余容量均已送入四川主网。为加强区内生态环境保护,鱼潭水电站的部分电力将用于进一步实施“以电代柴”,调整区内能源结构。 关键词:水利枢纽;闸坝;全闸方案;枢纽布臵

The abstract The Yutan hydrodynamic station is in a nature egis borough of Sichuan province, and it is a rundle hydrodynamic station of the Panda River potamic trunk which is a anabranch of Minjiang River.The hydrodynamic station mark out 24MW capability.And it is a press citation station. The milldam address locates big bridge downstream in the rock valley about the 700 meters. the place's decoration has already led a water to generate electricity the hole to take the water, has been gone to adjust to press well, then connected the pressure steel pipe that grows about the 300 meters to go to the power plant site to acquire about the 46 meters water head about the pressure hole with 2.6 kilo meters.There is a interprovincial highway stand the left of the milldan ,the traffic is so conveniency.The Panda river is on the right km.The milldan bank of Minjiang river, it is 87.9 kilo meters long, the drainage area is 1742 2 km drainage area,is of the 84% of the address is 30 km long from the bayou, control 1467 2 drainage area.The nature egis’s water resource is wealth, Now the river of the Panda has marked out 326.8MW ,aboat having 37.5% of its theories reserves. The Yutan hydrodynamic station stand a line will with once 110 kilo-Volts send a present in return to go into a Sichuan main net.It is not only can accelerate the economy of the nature egis borough,do well for the nature egis borough, and it will protect the rarity animal and foliage.That is having important economic meaning or society meaning.Now,this areas having buiding about 6.8MW mini-hydrodynamic station’s electric power.Those power is for process the farm produce,for investigate center,for farmer’s living illuming or using electricity to substitute firewood.And the superabundance of the power all sending to Sichuan main net.I n order to strengthen the ecosystem of the area, parts of electric powers will used for the further implement"with electricity substitute firewood", adjusting the energy structure inside the area. Keyword: Hydraulic pivot; milldam; entirely milldam project; Pivot lay

@单层厂房课程设计

单层工业厂房结构课程设计计算书一.设计资料 1.某金工车间,单跨无天窗厂房,厂房跨度L=21m,柱距为6m,车间总 长度为150m,中间设一道温度缝,厂房剖面图如图所示: 2.车间内设有两台中级工作制吊车,吊车起重量为200/50kN。 3.吊车轨顶标高为9.0m。 4.建筑地点:哈尔滨市郊。 5.地基:地基持力层为e及I L 均小于0.85的粘性层(弱冻胀土),地基 承载力特征值为f ak =180kN/m2。标准冻深为:-2.0m。 6.材料:混凝土强度等级为C30,纵向钢筋采用HRB400级,(360N/mm2) 箍筋采用HPB300级。(270N/mm2) 二. 选用结构形式 1.屋面板采用大型预应力屋面板,其自重标准值(包括灌缝在内)为 1.4kN/m2。 2.屋架采用G415(二)折线型预应力钢筋混凝土屋架,跨度为21m,端 部高度为2.3m,跨中高度为33.5m,自重标准值为83.0kN。 3.吊车梁高度为0.9m,自重30.4kN;轨道与垫层垫板总高度为184mm, 自重0.8kN/m。 4.柱下独立基础:采用锥形杯口基础。 三、柱的各部分尺寸及几何参数 采用预制钢筋混凝土柱

轨道与垫层垫板总高m h a 184.0= , 吊车梁高m h b 9.0= , 故 牛腿顶面标高=轨顶标高m h h b a 916.79.0184.00.9=--=-- 由附录12查得,吊车轨顶只吊车顶部的高度为m 3.2,考虑屋架下弦至吊车顶部所需空隙高度为mm 220,故柱顶标高=m 520.1122.03.20.9+=++ 基础顶面至室外地坪的距离取m 0.1,则 基础顶面至室内地坪的高度为m 15.115.00.1=+,故 从基础顶面算起的柱高m H 67.1215.152.11=+=, 上部柱高m 60.3,604.3916.752.11取为m H u =-= 下部柱高m 07.9,066.9604.367.12取为m H l =-= 上部柱采用矩形截面mm mm h b 400400?=?; 下部柱采用Ⅰ型截面mm mm mm mm h b h b f f 150100900400???=???。 上柱: mm mm h b 400400?=? (m kN g /0.41=) 25106.1mm h b A u ?=?= 4931013.212mm bh I u ?== 下柱: )/69.4(1501009004002m kN g mm mm mm mm h b h b f f =???=??? [])100400()1752900()1502900(4009001-??-+?--?=A 2510875.1mm ?= 33 3)3/25275(253005.0212 60030012400900+????+?-?= l I 4101095.1mm ?= 109.0105.191013.29 9 =??==l u I I n m H m H u 67.12,6.3==

水电站厂房设计

水电站厂房设计 一、水电站厂房的任务 水电站厂房是将水能转为电能的综合工程设施,包括厂房建筑、水轮机、发电机、变压器、开关站等,也是运行人员进行生产和活动 的场所。 水电站厂房的主要任务: (1) 将水电站的主要机电设备集中布置在一起,使其具有良好的运 行、管理、安装、检修等条件。 (2) 布置各种辅助设备,保证机组安全经济运行,保证发电质量。 (3) 布置必要的值班场所,为运行人员提供良好的工作环境。 二、水电站厂房的组成 (一) 从设备布置和运行要求的空间划分 主厂房:布置水电站的主要动力设备(水轮发电机组)和各种辅助设 备,设置装配场(安装间)。 副厂房:布置控制设备,电气设备和辅助设备,是水电站运行、控制、监视、通讯、试验、管理和工作的房间。 主变压器场:装设主变压器的地方。水电站发出的电能经主变压器 升压后,再经输电线路送给用户。 高压开关站:装设高压开关、高压母线、和保护措施等设备的场所, 高压输电线由此送往用户。 此外厂房枢纽中还有:进水道、尾水道和交通道路等。

水电站主厂房、副厂房、主变压器场和高压开关站及厂区交通等,组成水电站厂区枢纽建筑物,一般称厂区枢纽。 (二) 从设备组成的系统划分 水电站厂房内的机械及水工建筑物共分五大系统 (1) 水流系统。水轮机及其进出水设备,包括压力管道、水轮机前 的进水阀、蜗壳、水轮机、尾水管及尾水闸门等。 (2) 电流系统。即电气一次回路系统,包括发电机及其引出线、母 线、发电机电压配电设备、主变压器和高压开关站等。 (3) 电气控制设备系统。即电气二次回路系统,包括机旁盘、励磁设备系统、中央控制室、各种控制及操作设备如各种互感器、表计、继电器、控制电缆、自动及远动装置、通迅及调度设备等直流系统。 (4) 机械控制设备系统。包括水轮机的调速设备,如接力器及操作柜,事故阀门的控制设备,其它各种闸门、减压阀、拦污栅等操作 控制设备。 (5) 辅助设备系统。包括为了安装、检修、维护、运行所必须的各种电气及机械辅助设备,如厂用电系统(厂用变压器、厂用配电装置、直流电系统),油系统、气系统、水系统,起重设备,各种电气和机械修理室、试验室、工具间、通风采暖设备等。 水电站厂房组成(设备组成) (三) 从水电站厂房的结构组成划分 1.平面:主机室+安装间 主机室:水轮发电机组及辅助设备布置在主机室,是运行和管理的 主要场所;

水电站厂房课程设计

2015年秋水利水电工程专业水电站厂房课程设计 1.课程设计的目的 课程设计是以工程实例为题,由学生独立思考,灵活应用有关的布置原则和要点,自己动手布置厂房,从而巩固和加深厂房部分的理论知识,并进一步培养学生的计算,制图和应用技术资料的技能。 2.工程枢纽概况 水库库区跨越S、N两河,地处MY县城以北20km,两条河在MY县城以南约10km 处汇合成SN河。 水库是以防洪及工农业供水为主要任务,兼有发电效益的综合利用水利工程。 水库各特征水位如下: 死水位:▽126.0m 正常高水位:▽157.50m 设计洪水位:▽158.20m 校核洪水位:▽159.50m 坝顶高程:▽160.00m 主要建筑物包括: (1)挡水建筑物 有N、S主坝两座及副坝五处,为碾压式粘土斜墙土坝,最大坝高为N河主坝,高66.4m,S河主坝高56m,各副坝15.7m~39m不等。 (2)泄水建筑物 ①溢洪道:有S河左岸第一、第二溢洪道。第一溢洪道为正常溢洪道,底部高程▽140m,宣泄超过100年一遇的洪水,为5孔带胸墙式河岸溢洪道。 第二溢洪道为非常溢洪道,与第一溢洪道配合,宣泄1000年洪水,底部高程▽148.5m,为5孔开敞式河岸溢洪道。 ②隧洞: a. N河左岸发电隧洞,用作发电供水和下游工农业供水,并在调压井上游设泄水支洞,用以宣泄10000年一遇特大洪水。进水塔进口底部高程为▽116.0m,洞径6m,洞长416m,底坡i=1/400,调压室为园筒式,内径17.14m,调压室后接2根埋藏式压力钢管,管径5.5m,管长125m。

b. S河发电泄水隧洞,任务是施工导流,发电、灌溉、供水和泄水。 见图1所示。 ③坝下廊道: 为施工期的临时建筑物,施工导流采取S、N两河分别导流的方式,故设N河导流廊道、 210 180 150 图一:枢纽布置图(1:3000) S河导流廊道,可宣泄20年一遇洪水,另有南石骆驼输水廊道,用以泄放3个流量的

水电站设计方案.doc

坝后式水电站毕业设计 5.1 设计内容 5.1.1 基本内容 5.1.1.1 枢纽布置 (1) 依据水能规划设计成果和规范确定工程等级及主要建筑物的级别; (2) 依据给定的地形、地质、水文及施工方面的资料,论证坝轴线位置,进行坝型选择; (3) 论证厂房型式及位置; (4) 进行水库枢纽建筑物的布置(各主要建筑物的相对位置及形式,划分坝段),并绘制枢纽布置图。 5.1.1.2 水轮发电机组选择 (1) 选择机组台数、单机容量及水轮机型号; (2) 确定水轮机的尺寸(包括水轮机标称直径D1、转速n、吸出高度Hs、安装高程Za); (3) 选择蜗壳型式、包角、进口尺寸,并绘制蜗売单线图; (4) 选择尾水管的型伏及尺寸; (5) 选择相应发电机型号、尺寸,调速器及油压装置。 5.1.1.3厂区枢纽及电站厂房的布置设计 (1) 根据地形、地质条件、水文等资料,进行分析比较确定厂房枢纽布置方案; (2) 核据水轮发甴机的资料,选择相应的辅助设备,进行主厂房的各层布置设计; (3) 确定主厂房尺寸; (4) 副厂房的布置设计; (5) 绘制主厂房横剖面图、发电机层平面图、水轮机层和蜗壳层平面图各?张。 5.1.0 选作内容 5.1.2.1 引水系统设计 (1) 进水口设计。确定进水口高程、型式及轮廓尺寸; (2) 压力管道的布置设计。确定压力管道的直径;确定压力管道的布置方式和各段尺寸;

5.2 基本资料 本水电站在MD江的下游,位于木兰集村下游2km处。坝址以上流域控制面积30200km2。 本工程是一个发电为主,兼顾防洪、灌溉、航运及养鱼等综合利用的水利枢纽。电站投入运行后将承担黑龙江东部电网的峰荷,以缓解系统内缺乏水电进行调峰能力差的局面。 本工程所在地点交通比较方便,建筑材料比较丰富,是建设本工程的有利条件。电站地理位置图见图5-1。

《单层工业厂房》课程设计

《单层工业厂房》课程设计 姓名: 班级: 学号:

一.结构选型 该厂房是广州市的一个高双跨(18m+18m)的机械加工车间。车间长90m,柱矩6米,在车间中部,有温度伸缩逢一道,厂房两头设有山墙。柱高大于8米,故采用钢筋混凝土排架结构。为了使屋架有较大的刚度,选用预应力混凝土折线形屋架及预应力混凝土屋面板。选用钢筋混凝土吊车梁及基础梁。厂房的各构选型见表1.1 表1.1主要构件选型 由图1可知柱顶标高是10.20米,牛腿的顶面标高是6.60米,室内地面至基础顶面的距离0.5米,则计算简图中柱的总高度H,下柱高度H l和上柱的高度Hu分别为: H=10.2m+0.6m=10.8m H l=6.60m+0.6m=7.2m Hu=10.8m-7.2m=3.6m 根据柱的高度,吊车起重量及工作级别等条件,确定柱截面尺寸,见表1.2。 1.恒载

图1 求反力: F1=116.92 F2=111.90 屋架重力荷载为59.84,则作用于柱顶的屋盖结构的重力荷载设计值: G A1=1.2×(116.92+59.84/2)=176.81KN G B1=1.2×(111.90×6+59.84/2)=170.18 KN (2)吊车梁及轨道重力荷载设计值 G A3=1.2×(27.5+0.8×6)=38.76KN G B3=1.2×(27.5+0.8×6)=38.76KN (3)柱重力荷载的设计值 A,C柱 B柱 2.屋面活荷载 屋面活荷载的标准值是0.5KN/m2,作用于柱顶的屋面活荷载设计值: Q1=1.4×0.5×6×18/2=37.8 KN 3,风荷载 风荷载标准值按ωk=βzμsμzω0计算其中ω0=0.5KN/m2, βz=1, μz根据厂房各部分及B类地面粗糙度表2.5.1确定。 柱顶(标高10.20m)μz=1.01 橼口(标高12.20m)μz=1.06 屋顶(标高13..20m)μz=1.09 μs如图3所示,由式ωk=βzμsμzω0可得排架的风荷载的标准值: ωk1=βzμs1μzω0=1.0×0.8×1.01×0.5=0.404 KN/m2 ωk2=βzμs2μzω0=1.0×0.4×1.01×0.5=0.202 KN/m2

水电站毕业设计

目录 摘要 (1) 前言 (2) 第一部分:水力机组选型设计和调节保证计算 (3) 1水轮机的选型设计 (3) 1.1水轮机选型设计概述 (3) 1.2水轮机选型设计的任务 (3) 1.3水轮机选型的原则 (3) 1.4水轮机选型设计的条件及主要参数 (3) 1.5水轮机台数及型号的选择 (4) 1.6初选工况点A (5) 1.8额定转速的确定 (6) 1.9 效率及单位参数的修正 (7) 1.10 核对所选择的真机转轮直径 D................................... 错误!未定义书签。 1 1.11 确定水轮机导叶的最大可能开度 a.......................... 错误!未定义书签。 ok 1.12计算水轮机额定流量 Q ............................................... 错误!未定义书签。 r H ................................... 错误!未定义书签。 1.13确定水轮机的允许吸出高度 s 1.14计算水轮机的飞逸转速 (19) 1.15 计算水轮机轴向水推力∞ P ......................................... 错误!未定义书签。 1.16 估算水轮机的质量 (20) 1.17 绘制水轮机运转综合特性曲线 (20) 2水轮发电机的的初步选择计算 (24) 2.1水轮发电机的结构形式和冷却方式 (24) 2.2发电机主要尺寸的估算 (24) 2.3发电机外形尺寸估算 (25) 2.4水轮发电机的质量估算 (26) 3调节保证计算 (27) 3.1调节保证计算概述 (27) 3.2调节保证计算的标准 (27) 3.3计算基本数据 (27) L . 错误!未定义 3.4计算设计水头、最大水头下额定出力时引水系统的∑i i V 书签。 T和关闭规律 (28) 3.5假定导叶的直线关闭时间 f 3.6水击压力上升计算 (28)

单层工业厂房毕业设计开题报告毕业论文

单层工业厂房毕业设计开题报告毕业论文 一、本项设计的性质及目标 混凝土结构结合了钢筋与混凝土的优点,造价较低,是土木工程结构设计中的首选形式,其应用范围非常广泛。虽然,随着新的结构计算理论的提出和新型建筑材料的出现,将来还会出现许多新的结构形式,但可以肯定的是,混凝土结构仍然是最常用的结构形式之一[1]。 近年来,随着控制粘土实心砖的使用,新型砌体材料不断涌现,如混凝土小型空心砌块,结多孔砖,蒸压灰砂砖,蒸压粉煤灰砖,轻骨料混凝土砌块等。按照砌体结构中的配筋率大小可将其分为无筋砌体、约束砌体和配筋砌体三类。含筋量在0.07%以下时,配筋量很少称为无筋砌体;约束砌体的配筋量为 0.07%-0.17%左右,此类砌体的特点是在砌体周边均设置配筋混凝土约束构件,此种做法是为增强墙体性能而采取的构造手段,不是因强度不足进行的配筋;配筋砌体的配筋率为0.2%,接近于现浇钢的混凝土剪力墙结构,是近年来新兴的砌体结构形式,适用于10 层以上的中高层建筑,其实质是一种砌筑成的剪力墙结构,施工方便、快捷[2]。 轻钢结构建筑在建筑规模的表现上,表现得相当出色,特别是一脊双玻或带女儿墙的大跨度轻钢结构建筑,具有恢弘的建筑气势。这种用建筑规模表现建筑风格的作品,出自国内企业之手的,目前还不多见。 由于门式刚架轻钢结构具有许多其他结构不具有的优点,同时经济效益好,使其得到了广泛的应用。20世纪60年代在国外由于各种彩色钢板和H型钢和冷弯型钢的出现推动了门式刚架轻钢结构的快速发展[3]。 门式钢架轻型房屋结构在我国的应用大约始于20世纪80年代初期。主要用于轻型的厂房、仓库、建材等交易市场、大型超市、体育馆、展览厅及活动房屋、加层建筑等。目前,国内大约每年有上千万平方米的轻钢建筑竣工。在此背景下,国外轻钢结构生产厂商也纷纷在我国设分公司、制造厂,获得了很大的销售量。

沁河河口村水库大机组电站厂房设计

沁河河口村水库大机组电站厂房设计 刘增强 柴志阳 孟旭央 (黄河勘测规划设计有限公司 工程设计院) [摘 要]河口村水库以防洪、供水为主,兼顾灌溉、发电和改善河道基流等综合作用。电站分大机组和小机组两个电站,总装机容量为11.6 MW。其中大电站以发电为主,并提供生态基流,装机容量为10 MW;小电站兼发电和向沁北电厂供水双重任务,装机容量为1.6 MW。本文主要讲述大电站的厂区布置、结构布置、副厂房结构布置设计优化及稳定应力计算等内容,为类似工程的设计可提供一定参考价值。 [关键词]电站厂房 河口村水库 沁河 1 工程概述 河口村水库位于黄河一级支流沁河最后一段峡谷出口处,下距五龙口水文站约9 km,属河南省济源市克井乡,是控制沁河洪水、径流的关键工程,也是黄河下游防洪工程体系的重要组成部分。开发任务是“以防洪、供水为主,兼顾灌溉、发电、改善河道基流等综合利用”。水库总库容3.17亿m3,最大坝高122.5 m,正常蓄水位275 m。 电站分大、小机组两个电站,总装机容量11.6 MW。大电站以发电为主,并提供生态基流;小电站兼发电和向沁北电厂供水双重任务。大机组电站为岸边式地面厂房,由2台混流式水轮发电机组、安装间及副厂房组成,总装机容量为10 MW,额定水头76.00 m,单机额定流量7.80 m3/s,机组安装高程为171.20 m。 根据《中国地震动参数区划图》(GB18306-2001),确

定河口村坝址场地地震动反应谱特征周期为0.40 s,地震动峰值加速度0.1 g,确定电站抗震设计烈度为7度。 河口村水库工程等别为Ⅱ等,属大(2)型。根据《水利水电工程等级划分及洪水标准》(SL252-2000),电站厂房及次要建筑物为3级,电站厂房按50年一遇洪水设计,200年一遇洪水校核。 2 大机组电站厂区布置 大电站采用岸边式地面厂房布置型式,安装间布置在主机间右侧,中控室及交接班室均布置在安装间的上游侧,主变压器布置在主机间上游室外地面高程180.00 m的平台上,考虑主变检修、消防等要求,两台主变压器之间,变压器与主厂房、中控室分别通过防火墙分隔。 厂房上游侧设置不小于4.00 m宽的消防通道,路面高程为180.00 m,可以满足消防车作业的需要,净空高度无障碍,满足有关规范要求。主厂房的对外交通出入口,布置在安装间右山墙侧,与进厂公路平顺相连。 尾水平台高程为180.00 m,高于200年一遇校核尾水位179.45 m。机组尾水闸门孔口尺寸为2.82 m×1.34 m(宽×高),底坎高程168.39 m,采用平板钢闸门,两台机组共用一台单轨移动式启闭机,为满足尾水闸门检修要求,计算确定起闭机牛腿底高程为185.30 m。

单层工业厂房毕业设计(借鉴分享)

管坯车间厂房建筑结构设计 摘要 本设计为某单层厂房,本车间的主要任务是堆放钢材坯料及运输。本厂房为两跨等跨等高厂房,跨度为24m,每跨吊车都为32T。因为该厂房地区抗震设防烈度为7度,所以在设计中考虑地震作用。在建筑设计中根据厂房的生产状况、建厂地点、水文、地质条件、工艺流程等条件对厂房的平面布置、剖面、采光、支撑、基础梁、吊车梁和排水系统等进行了设计。在结构设计中根据本厂房的条件在相关图集中选择合适的构件。在荷载计算中根据构件选择计算自重荷载,活载、风载、吊车荷载,根据底部剪力法计算各荷载,然后根据内力组合原则确定各截面最不利内力。在考虑地震作用时,对柱子考虑空间作用,乘以调整系数。在内力组合中选择最不利内力分别对无地震和有地震进行组合,然后对柱子进行抗震、牛腿、吊装验算和配筋计算,最后进行基础选形、验算及配筋。 关键词:单层厂房;建筑设计;结构设计;地震作用

A building structure design of Yingkou pipe workshop Abstract This design is a single plant in yingkou region, the main task of this workshop is stacked steel billet and transport. Across such plant, this plant for the two across the span of 24 m, each cross crane to 32 t. Because the region of the factory seismic fortification intensity is 7 degrees, so it considers in the design seismic action. In architectural design on the production status of the factory, factory location, hydrological, geological conditions and process conditions on the plant layout, section, daylighting, support, foundation beam and crane girder and drainage system design. According to the condition of this plant in the structure design in the related images on choosing appropriate artifacts. In load calculation according to the weight of component selection calculation load, live load, wind load, crane load, according to the bottom shearing force method to calculate the charge, then the section the most adverse internal force was established according to the principle of internal force combination. When considering earthquake action, the columns considering spatial effect, multiplied by the coefficient of adjustment. In internal force combination, choosing the most adverse internal force of no earthquake and earthquake are combined, respectively, then the post cracking, bracket, hoisting and checking and reinforcement calculation, finally carries on the foundation type selection, calculation and reinforcement. Keywords:Single-layer workshop ;Architectural design ;Structural design; Earthquark effect

水电站厂房课程设计

《水电站》课程设计目录 目录 第一章任务书 (1) 1.1 目的 (1) 1.2 设计内容和要求 (1) 1.3 应提交的设计成果 (1) 第二章基本资料 (2) 2.1 工程概况 (2) 2.2 电站枢纽 (2) 2.3 设计依据及参数 (2) 第三章设计过程 (5) 3.1 确定设备尺寸 (5) 3.1.1 蜗壳尺寸 (5) 3.1.2 水轮机和尾水管尺寸 (6) 3.1.3 发电机尺寸 (7) 3.2 厂房尺寸 (7) 3.2.1 主厂房的平面尺寸 (7) 3.2.2 主厂房的立面尺寸 (9) 3.3 主厂房各层布置 (10) 3.3.1 发电机层布置 (10) 3.3.2 水轮机层布置 (11) 3.3.3 蜗壳层布置 (12) 3.4 副厂房的布置 (12) 3.5 厂区枢纽布置 (12)

第一章任务书 1.1 目的 通过本设计,进一步巩固和加深水电站厂房部分的理论知识,使学生初步掌握水电站厂房设计的步骤和方法,培养和提高学生独立分析问题和运用所学理论知识解决实际问题的能力。 1.2 设计内容和要求 根据给定的原始资料及机电设备,决定厂房在枢纽中的位置,进行厂区和厂房内部的布置,确定厂房的轮廓尺寸。 1.3 应提交的设计成果 (-)设计说明书一份。 (二)水电站厂房设计布置图三张: 1、沿机组中心线厂房横剖面图(1:100); 2、发电机层平面图(1:100-1:200); 3、水轮机层、蜗壳层综合平面图(1:100-1:200)。 (三)厂房枢纽布置简图一张(1:1000)。

第二章基本资料 2.1 工程概况 湘贺水利枢纽位于向河上游,河流全长270km,流域面积6000km2,属于山区河流。本枢纽控制流域面积1350km2,总库容22.15m3,为多年调节水库。 本枢纽的目标是防洪和发电。主要建筑物有重力拱坝,坝高77.5m,弧长370m;泄洪建筑物;开敞式溢洪道或泄洪隧洞;发电引水隧洞及岸边地面厂房等工程。水电站总装机60MW,装机4台,单机15MW。电站担任工农业负荷,全部建成后担任系统灌溉负荷。 2.2 电站枢纽 电站厂房位于右岸坝下游几十米处,由引水隧洞供水,主洞内径5.5m,支洞内径3.4m,厂内装置4台混流式立式机组,出线方向为下游,永久公路通至左岸,开关站布置在左岸开阔平地上。 2.3 设计依据及参数 (一)水库及水电站特征参数 (1)水库水位。水库校核洪水位为140.00m,水库设计洪水位为137.00m,水库正常蓄水位为125.00m,水库发电死水位为108.00m,设计洪水尾水位为77.00m,校核洪水尾水位为78.50m。 (2)厂址水位—流量关系见表2—1. (3)水电站特征水头。最大水头为56.00m,最小水头为38.00m,平均水头为50.84m, 2

单层工业厂房课程设计计算书(完整版)

《单层工业厂房混凝土排架课程设计》1.1 柱截面尺寸确定 由图2可知柱顶标高为12.4 m,牛腿顶面标高为8.6m ,设室内地面至基础顶面的距离为0.5m ,则计算简图中柱的总高度H、下柱高度 l H、上柱高度Hu分别为: H=12.4m+0.5m=12.9m, l H=8.6m+0.5m=9.1m Hu=12.9m-9.1m=3.8m 根据柱的高度、吊车起重量及工作级别等条件,可由表2.4.2并参考表2.4.4确定柱截面尺寸,见表1。 表1 柱截面尺寸及相应的计算参数 计算参数柱号截面尺寸 /mm 面积 /mm2 惯性矩 /mm4 自重 /(KN/ m) A , B 上柱矩400×400 1.6×10521.3×108 4.0 下柱I400×900×100×150 1.875×105195.38×108 4.69 本例仅取一榀排架进行计算,计算单元和计算简图如图1所示。

1.2 荷载计算 1.2.1 恒载 (1).屋盖恒载: 两毡三油防水层0.35KN/m2 20mm厚水泥砂浆找平层20×0.02=0.4 KN/m2 100mm厚水泥膨胀珍珠岩保温层4×0.1=0.4 KN/m2 一毡二油隔气层0.05 KN/m2 15mm厚水泥砂浆找平层;20×0.015=0.3 KN/m2 预应力混凝土屋面板(包括灌缝) 1.4 KN/m2 2.900 KN/m2 天窗架重力荷载为2×36 KN /榀,天沟板2.02 KN/m,天沟防水层、找平层、找坡层1.5 KN/m,屋架重力荷载为106 KN /榀,则作用于柱顶的屋盖结构重力荷载设计值为: G1=1.2×(2.90 KN/m2×6m×24m/2+2×36 KN/2+2.02 KN/m×6m +1.5 KN/m×6m+106 KN/2) =382.70 KN (2) 吊车梁及轨道重力荷载设计值: G3=1.2×(44.2kN+1.0KN/m×6m)=50.20 KN

水电站厂房设计

第十一章水电站地面厂房布置设计 第一节水电站厂房的任务、组成及类型 一、水电站厂房的任务 水电站厂房是水能转为电能的生产场所,也是运行人员进行生产和活动的场所。其任务是通过一系列工程措施,将水流平顺地引入水轮机,使水能转换成为可供用户使用的电能,并将各种必需的机电设备安置在恰当的位置,创造良好的安装、检修及运行条件,为运行人员提供良好的工作环境。 水电站厂房是水工建筑物、机械及电气设备的综合体,在厂房的设计、施工、安装和运行中需要各专业人员通力协作。 二、水电站厂房的组成 水电站厂房的组成可从不同角度划分。 (一)从设备布置和运行要求的空间划分 (1)主厂房。水能转化为机械能是由水轮机实现的,机械转化为电能是由发电机来完成的,二者之间由传递功率装置连接,组成水轮发电机组。水轮发电机组和各种辅助设备安装在主厂房内,是水电站厂房的主要组成部分。 (2)副厂房。安置各种运行控制和检修管理设备的房间及运行管理人员工作和生活用房。 (3)主变压器场。装设主变压器的地方。水电站发出的电能经主变压器升压后,再经输电线路送给用户。 (4)开关站(户外配电装置)。为了按需要分配功率及保证正常工作和检修,发电机和变压器之间以及变压器与输电线路之间有不同电压的配电装置。发电机侧的配电装置,通常设在厂房内,而其高压侧的配电装置一般布置在户外,称高压开关站。装设高压开关、高压母线和保护设施,高压输电线由此将电能输送给电力用户。 水电站主厂房、副厂房、主变压器场和高压开关站及厂区交通等,组成水电站厂区枢纽建筑物,一般称厂区枢纽。 (二)从设备组成的系统划分 水电站厂房内的机械及水工建筑物共分五大系统 (1)水流系统。水轮机及其进出水设备,包括压力管道、水轮机前的进水阀、蜗壳、水轮机、尾水管及尾水闸门等。 (2)电流系统。即电气一次回路系统,包括发电机及其引出线、母线、发电机电压配电设备、主变压器和高压开关站等。 (3)电气控制设备系统。即电气二次回路系统,包括机旁盘、厉磁设备系统、中央控制室、各种控制及操作设备如各种互感器、表计、继电器、控制电缆、自动及远动装置、通迅及调度设备等直流系统,如图11-1所示。

水电站厂房课程设计计算书1

2013年秋季学期课程设计 水利与环境学院系(院)水利水电工程专业 题目水电站厂房课程设计 学生姓名胡浩凡 班级10水利水电工程(1)班 学号2010101143 指导教师朱士江 日期2014 年01 月08 日 三峡大学教务处订制

水电站厂房课程设计说明书 1 绘制蜗壳单线图 1.1蜗壳的型式: 首先,本水电站水轮机的最大工作水头80.440>=m H m m ,应采用金属蜗壳;其次,由水轮机的型号HL220—LJ —120,可知本水电站采用金属蜗壳。 1.2蜗壳主要参数的选择 金属蜗壳的断面形状为圆形 为了获得良好的水力性能,圆形断面金属蜗壳的包角一般取φ0 =345°(P98)。 由基本资料可知: 3max 12.03m /s =Q 蜗壳进口断面流量max 0360 ?= c Q Q 3345 12.0311.53/360 = ?=c Q m s 。 由图4—30(P99)查得蜗壳进口断面平均流速 6.6/=c V m s 。 1.3座环尺寸 查金属蜗壳座环尺寸系列表可知,表中最小转轮直径为1800mm 。对表中数据进行分析,发现转轮直径和座环内外径成线性关系,利用excel 拟合直线,求出 17.3074983.11+=D D a , 54.1852938.11+=D D b 。 当11200=D mm 时 mm D a 2105=,mm D b 1738=,则mm r a 5.1052=,mm r b 869=。 其中:b D —座环内径;a D —座环外径;b r —座环内半径;a r —座环外半径。

座环示意图如下图所示 座环尺寸(单位:mm ),比例1:100 1.4蜗壳的水力计算 1.4.1对于蜗壳进口断面(P100) 断面面积20max 34512.03 1.75360360 6.6 ??= ===?c c c c Q Q F m V V 断面的半径0max max 0.746360360 6.6ρπ π = = = =???c m V 。 从轴中心线到蜗壳外缘的半径:max max 2 1.052520.746 2.545ρ=+=+?=a R r m 。 1.4.2 对于断面形状为圆形的任一断面的计算 设i ?为从蜗壳鼻端起算至计算面i 处的包角,则该计算断面处的max 360 i i Q Q ?= , i ρ= 2i a i R r ρ=+。 其中:3max 12.03/=Q m s , 6.6/=c V m s , 1052.5 1.0525==a r mm m 。 表 1—1

水电站厂房设计及问题分析与解决措施一

水电站厂房设计及问题分析与解决措施 摘要:随着科学技术的快速发展,我国的水电站建设越来越多,伴随着的水力发电被广泛应用起来。然而水电站厂房建设是水电站的基础建设,只有合理地对水电站厂房进行设计,在施工中解决问题,才能根本的解决水电站厂房的建设问题。本文主要分析了水电站厂房设计,并对水电站厂房建设存在的问题和解决措施进行了探讨。 关键词:水电站厂房;设计;问题;解决措施 一、水电站厂房设计 1.1 方案确定 在水电站厂房的方案确定过程中,应对厂址的地质、地形、水文条件以及施工单位具体要求等方面做实地考察与研究,并确定最佳的建设方案。例如在考察过程中,可确定河床式或者引水式以及长尾水渠式等形式,以确保使其发挥最大的效果。 1.2 布置特点 在厂房的布置方面,对于地形特点的依赖性更大。包括各个建筑的排布形式、溢洪坝位置、厂房布置位置等方面。核心方面就是发电厂房,特别要考虑河床弯道水流的影响, 应使水流进出厂房顺畅, 泥砂不易淤积, 确保安全运行, 管理方便。以某水电站建设为例,在建设过程中,发现河床较宽,因此可采用“一”字形排布;同时与闸坝结构合为一体,便于利用水力条件。在这一过程中,还需要保证施工的安全可靠。 1.3 参数标准 在厂房本身的设计过程中,需要充分考虑水源的蓄水深度、总水含量、装机容量等方面,同时也需要考虑附近农田的面积。以确保水电站在发电的过程中,也具有灌溉、泄洪及蓄水等综合作用。一般来讲,根据当地近100 年来的气候特点,对水电站厂房的抗风、抗震能力需要论证,并给与相应的极限范围。 1.4 配套设施的布置设计 (1)主变压器与开关站 主变压器可安置两台,紧邻安装场,同时可利用钢轨道进行推进。对于开关站来说,为保证其安全可靠,采取户内式结构。同样紧邻安装场,距离约15 米。实际执行过程中,有两回进线、四回出线的形式进行,提高了效率。 (2)交通安排 厂房内部的交通较为便利,上下层之间有楼梯连接,各个工作室或者设施之间有通道连接。在室外也有各类通道相连,便于人行和机动车辆行驶。 (3)排水系统 对于厂房的排水系统,主要由深水泵及集水井完成。并在厂房机组上游布置排水廊道。在实际应用过程中,与集水井相通。为了防洪需要和不至于发生洪水淹没厂房的事故,下游最高洪水位低于厂区地面高程,厂区排水均通过地面排水沟自动排至下游尾水渠内。

相关文档