超限高层结构设计计算分析

超限高层结构设计计算分析
超限高层结构设计计算分析

超限高层结构设计及计算分析研究摘要:通过结合某高度超限高层结构设计实例,通过经济性比较分析,对该结构底层1/3高度的柱采用型钢混凝土柱,结构类型仍采用框架核心筒,可有效提高结构经济性;同时按抗震性能3设计,对竖向构件和关键结构构件采取中震不屈服设计,采用satwe 和madis有限元软件对该超限结构进行抗震抗风计算及分析,计算结果表明所得到的结构自振特性、层间位移等符合规范要求。

关键词:超限高层结构;高度超限;抗震计算分析;结构设计abstract: through the combined with a highly overrun high-rise structure design example, through the economical comparison analysis, the structure of the bottom of the height of the third column using steel reinforced concrete column, still use a frame structure types of the core tube, which can effectively improve the economy structure; at the same time in seismic performance 3 design, to vertical component and key components to take the shock of do not yield designs, adopting the satwe and madis finite element software to the off-gauge structure seismic wind calculation and analysis of the calculation results show that the structure of the obtained self-vibration characteristics, such as displacement between floors conform to the standard.

keywords: overrun high-rise structure; highly overrun;

高层建筑结构设计试题及复习资料

高层建筑结构设计 名词解释 1. 高层建筑:10层及10层以上或房屋高度大于28m 的建筑物。 2. 房屋高度:自室外地面至房屋主要屋面的高度。 3. 框架结构:由梁和柱为主要构件组成的承受竖向和水平作用的结构。 4. 剪力墙结构:由剪力墙组成的承受竖向和水平作用的结构。 5. 框架—剪力墙结构:由框架和剪力墙共同承受竖向和水平作用的结构。 6. 转换结构构件:完成上部楼层到下部楼层的结构型式转变或上部楼层到下部楼层结构布置改变而 设置的结构构件,包括转换梁、转换桁架、转换板等。 7. 结构转换层:不同功能的楼层需要不同的空间划分,因而上下层之间就需要结构形式和结构布置 轴线的改变,这就需要在上下层之间设置一种结构楼层,以完成结构布置密集、墙柱较多的上层向结构布置较稀疏、墙术较少的下层转换,这种结构层就称为结构转换层。(或说转换结构构件所在的楼层) 8. 剪重比:楼层地震剪力系数,即某层地震剪力与该层以上各层重力荷载代表值之和的比值。 9. 刚重比:结构的刚度和重力荷载之比。是影响重力?-P 效应的主要参数。 10. 抗推刚度(D ):是使柱子产生单位水平位移所施加的水平力。 11. 结构刚度中心:各抗侧力结构刚度的中心。 12. 主轴:抗侧力结构在平面内为斜向布置时,设层间剪力通过刚度中心作用于某个方向,若结构产 生的层间位移与层间剪力作用的方向一致,则这个方向称为主轴方向。 13. 剪切变形:下部层间变形(侧移)大,上部层间变形小,是由梁柱弯曲变形产生的。框架结构的 变形特征是呈剪切型的。 14. 剪力滞后:在水平力作用下,框筒结构中除腹板框架抵抗倾复力矩外,翼缘框架主要是通过承受 轴力抵抗倾复力矩,同时梁柱都有在翼缘框架平面内的弯矩和剪力。由于翼缘框架中横梁的弯曲和剪切变形,使翼缘框架中各柱轴力向中心逐渐递减,这种现象称为剪力滞后。 15. 延性结构:在中等地震作用下,允许结构某些部位进入屈服状态,形成塑性铰,这时结构进入弹 塑性状态。在这个阶段结构刚度降低,地震惯性力不会很大,但结构变形加大,结构是通过塑性变形来耗散地震能量的。具有上述性能的结构,称为延性结构。 16. 弯矩二次分配法:就是将各节点的不平衡弯矩,同时作分配和传递,第一次按梁柱线刚度分配固 端弯矩,将分配弯矩传递一次(传递系数C=1/2),再作一次分配即结束。 第一章 概论 (一)填空题 1、我国《高层建筑混凝土结构技术规程》(JGJ3—2002)规定:把10层及10层以上或房屋高度大于28m 的建筑物称为高层建筑,此处房屋高度是指室外地面到房屋主要屋面的高度。 2.高层建筑设计时应该遵循的原则是安全适用,技术先进,经济合理,方便施工。 3.复杂高层结构包括带转换层的高层结构,带加强层的高层结构,错层结构,多塔楼结构。

某超限高层结构性能设计与分析

某超限高层结构性能设计与分析 发表时间:2017-04-10T13:42:53.793Z 来源:《基层建设》2017年1期作者:侯怡[导读] 摘要:本工程为B级高度的部分框支剪力墙结构,介绍了工程的特点和结构体系的选择,并针对结构的超限情况提出相关抗震加强措施。 中铁二局集团勘测设计院有限责任公司成都 610000 摘要:本工程为B级高度的部分框支剪力墙结构,介绍了工程的特点和结构体系的选择,并针对结构的超限情况提出相关抗震加强措施。采用YJK及MIDAS Building振型分解反应谱进行弹性阶段的计算分析,另采用弹性时程分析法进行多遇地震下的补充计算;抗震设防地震作用下,采用YJK等效弹性法对底部加强部位和薄弱部位进行中震弹性、中震不屈服设计,采用EPDA&PUSH进行弹塑性静力分析校 核构件的不屈服以及弹性状态;罕遇地震下采用EPDA&PUSH进行塑性动力时程分析。分析结果表明结构在地震作用下的反应和破坏机制均能满足预期性能目标。 关键词:超限高层;框支剪力墙;性能设计;动力弹塑性时程分析 1 工程概况 本工程位于四川省成都市金牛区一环路以南,通锦路以西,马家花园路以东。项目由9个单元的高层住宅,一栋商业会所,若干特色商业院落组成,地下为三层停车场。本文以其中的13号楼为研究的对象,地上42层,其中1-4层为商业用房5层及以上为住宅,主楼建筑高度137.7米。根据建筑功能需要,在商业顶板进行结构转换。 工程场地抗震设防烈度为7度(0.10g),建筑场地类别为Ⅱ类,设计地震分组为第三组,特征周期为0.45s。抗震设防分类为丙类,安全等级二级,设计基准周期50年,设计使用年限50年。 2 结构体系及布置 本工程采用钢筋混凝土部分框支-剪力墙结构,采用梁式转换。部分框支柱因水平地震剪力较大,为避免使用更大截面框支柱对建筑使用功能产生影响,特采用型钢混凝土柱。转换层平面布置详见图1。 本工程塔楼拟采用变厚度筏板基础,裙楼和地下室采用独立基础加抗水板,持力层为中密或密实卵石层,其地基承载力特征值分别为fak=550Kpa、fak=750Kpa。 本工程建筑高度139.7米,为B及高度,根据相关要求,须作抗震设防专项审查。除高度超限外,还存在扭转不规则、平面不规则及竖向构件不连续等三项不规则项。 3 抗震性能目标设计 综合考虑抗震设防类别、设防烈度、场地条件、建筑物功能、结构的特征、构件的部位和重要程度以及开发商的需求,依据《高层建筑混凝土结构技术规程》和《建筑抗震设计规范》选定结构抗震性能目标为C级。针对抗震性能目标的不同抗震性能水准,设计时的具体计算控制指标见表1。

高层建筑结构设计原则及意义分析

高层建筑结构设计原则及意义分析 发表时间:2018-11-29T18:12:15.133Z 来源:《防护工程》2018年第22期作者:周德泓 [导读] 随着社会的不断进步和科技的不断发展,高层建筑越来越广泛的出现在城市建设中。 中国联合工程有限公司 310000 摘要:随着社会的不断进步和科技的不断发展,高层建筑越来越广泛的出现在城市建设中。在高层建筑结构设计方面出现了新的发展和变化。高层建筑的结构设计已经成为了高层建筑设计的重点内容,因此,研究高层建筑结构设计的问题是非常重要和有意义的。介绍了高层建筑结构特征,分析了高层建筑结构设计的原则,阐述了高层建筑结构体系的选型问题,并重点分析了高层建筑结构设计问题及对策。 关键词:高层建筑结构;设计;对策 0 引言 随着科技和社会的不断发展和进步,自从19 世纪以来出现了现代高层建筑,高层建筑越来越广泛的出现在人们的生活中。作为一个庞大复杂的系统,高层建筑的结构设计,一方面要满足包括抗震,抗风等在内的安全性能的要求,另一方面,也要满足高层建筑结构的科学性和合理性。 1 高层建筑结构的特征 高层建筑结构不但承受着由于外界的风产生的水平方向的荷载,同时也承受着在垂直方向的荷载,并且对于地震的抵抗能力也有要求。一般情况下,建筑结构受到低层建筑结构水平方向上的影响比较弱,然而在高层建筑中,外界地震的影响和外界风产生的水平方向的荷载的影响是主要的影响因素。随着建筑物高度的增加,高层建筑的位移增加较快,但是高层建筑过大的侧移不但影响人的舒适度,同时使得建筑物的使用受到影响,并且容易损坏结构构件以及非结构构件。基于此,在设计高层建筑结构时,首先控制侧移在规定的范围之内,所以,高层建筑结构设计的核心是抗侧力结构的设计。 2 高层建筑结构设计的原则 2.1 选择合理的高层建筑结构计算简图在计算简图基础上进行高层建筑结构设计的计算,如果选择不合理的计算简图,那么就比较容易造成由于结构安发生的事故,基于此,高层建筑结构设计安全保证的前提是合理的计算简图的选择。同时,计算简图应该采用相应的构造方法保证安全。在实际的结构中,其结构节点不单是钢节点或者饺节点,保证和计算简图的误差在规范规定的范围内。 2.2 选择合理的高层建筑结构基础设计按照高层建筑地质条件进行基础设计的选择。综合分析高层建筑上部的结构类型与荷载分布情况,考虑施工条件,相邻的建筑物的影响等各个因素,在此基础上选择科学合理的基础方案。基础方案的选择应该使得地基的潜力得到最大程度的发挥,必要的时候要求进行地基变形的检验。高层建筑设计要有详细的地质勘查报告,如果缺失,那么应该进行现场勘查并参考相邻建筑物的有关资料。一般情况下,相同结构单元应该采用相同的类型。 2.3 选择合理的高层建筑结构方案合理的结构设计方案必须满足经济性的要求,并且要满足结构形式和结构体系的要求。结构体系的要求是受力明确,传力简单。在相同的结构单元当中,应该选择相同结构体系,如果高层建筑处于地震区,那么应力需要平面和竖向的规则。在进行了地理条件,工程设计需求,施工条件,材料等的综合分析的基础上,并和建筑包括水,暖,电等各个专业的相协调的情况下,选择合理的结构,从而确定结构的方案。 2.4 对计算结果进行准确的分析随着科技的不断进步,计算机技术被广泛的应用在建筑结构的设计中。当前市场上存在着形形色色的计算软件,采用不同的软件得到的结果可能不同,所以,建筑结构设计人员在全面了解的软件使用的范围和条件的前提下,选择合适的软件进行计算。由于建筑结构的实际情况和计算机程序并不一定完全相符,所以进行计算机辅助设计的时候,出现人工输入误差或者因为软件本身存在着缺陷使得计算结果不准确的问题,基于此,结构设计工程师在得到了通过计算机软件得到的结果以后,应该进行校核,进行合理判断,得出准确结果。 2.5 高层建筑的结构设计要采用相应构造措施高层建筑结构设计的原则是强剪切力弱弯变,强压力弱拉力,强柱弱梁。高层建筑结构设计过程中把握上述原则,加强薄弱部位,对钢筋的执行段锚固长度给予重视,并且要重点考虑构件延性的性能和温度应力对构件的影响。 3 高层建筑结构体系的选型 建筑的结构在抵抗来自于水平方向和竖直方向的荷载时构件的组成形式和传力的路径就是高层建筑的结构体系。通过包括墙,柱等的竖向构件和楼盖等水平构件将竖向荷载传递到基础,利用抗侧力体系将水平荷载传递到基础。 根据高层建筑结构的材料将高层建筑的结构体系分为钢筋混凝土结构体系,钢结构体系,钢-混凝土混合结构体系以及钢-混凝土组合结构体系。钢筋混凝土结构体系被广泛的应用在各类的工程结构中,具有混凝土和钢筋两种材料的协同受力性能特征,造价低廉,耐久耐火,成本低,整体性能优良,但存在着自重大,延性差,施工慢等缺点;钢结构体系的强度高,抗震性能比较好,施工方便,跨度大,用途多,但是存在着费用高,防火性能差,施工复杂等不足;钢-混凝土混合结构结合了钢筋混凝土构件和钢构件的长处,不但增加了钢构件的材料强度,同时具有较高的抗震性能,成本低廉,然而这两种材料构件的连接技术还存在着不足;钢-混凝土组合结构具有承载能力高,抗震性能强,比钢结构具有更优良的耐火性,施工速度快,但是存在着节点的构造比较复杂的缺点,一般被用于小屁偏心受压构件。 根据结构形式可以将高层建筑结构分为框架结构体系,剪力墙结构体系,框架-剪力墙结构体系。利用柱,梁等结构体系作为高层建筑竖向承重的结构,并且承受水平荷载,这种结构侧向位移大,框架结构内力大,适于50m 高度以下的建筑;通过高层建筑的墙体当做抵抗侧力和竖向承重的结构体系,就是剪力墙结构体系。这种剪力墙结构的刚度大,整体性能好,不易受水平力作用发生变形,适应于高层建筑,但是由于剪力墙的间距小,使得平面的布置不灵活,因此,在公共建筑中不宜使用;利用框架和剪力墙组合的而构成的结构形式就是框架-剪力墙结构体系,这种结构形式不但具有实用性强,布局灵活的优点,同时承受水平负载的能力更高,在高层建筑中被广泛使用。在框架-剪力墙结构体系中,需要注意考虑剪力墙的位置,设计合理的剪力墙的数量,以及满足框架的设计要求。

结构设计原理复习题 及答案.

结构设计原理复习题 一、选择题 1、混凝土强度等级按照( )确定 A 、立方体抗压强度标准值 B 、立方体抗压强度平均值 C 、轴心抗压强度标准值 D 、轴心抗压强度设计值 2、同一强度等级的混凝土,各种强度之间的关系是( ) A 、c f >cu f >t f B cu f >t f >c f C 、cu f >c f >t f D 、t f >cu f >c f 3、在测定混凝土立方体抗压强度时,《桥规》(JTG D —2004)采用的标准试件尺寸为( ) 的立方体。 A 、mm 100 B 、mm 150 C 、mm 180 D 、mm 200 4、混凝土棱柱体抗压强度用符号( )表示 A 、c f B 、cu f C 、t f D 、s f 5、分别用mm 150和mm 200的立方体试件进行抗压强度试验,测得的抗压强度值为( ) A 、mm 150的立方体低于mm 200的立方体 ; B 、mm 150的立方体高于mm 200的立方体 ; C 、mm 150的立方体等于mm 200的立方体 ; D 、mm 150的立方体低于mm 200的立方体 ,是因为试件尺寸越小,抗压强度就越小; 6、同一强度等级的混凝土,棱柱体试件的抗压强度与立方体试件的抗压强度关系是( ) A 、立方体抗压强度与棱柱体抗压强度相等 B 、立方体抗压强度高于棱柱体抗压强度 C 、立方体抗压强度低于棱柱体抗压强度 D 、无法确定 7、混凝土双向受压时,其强度变化规律是( ) A 、一向混凝土强度随着另一向压应力的增加而增加 B 、一向混凝土强度随着另一向压应力的增加而减小 C 、双向受压强度与单向受压强度相等 D 、双向受压强度低于单向受压强度 8、混凝土弹性模量的基本测定方法是( ) A、在很小的应力(c c f 3.0≤σ)下做重复加载卸载试验所测得 B、在很大的应力(c σ>c f 5.0)下做重复加载卸载试验所测得 C、应力在0=c σ~c f 5.0 之间重复加载卸载5~10次,取c σ=c f 5.0时所测得的变形值作为混凝土弹性模量的依据 D、以上答案均不对 9、混凝土的线性徐变是指徐变变形与( )成正比。 A、混凝土强度 B、时间 C、温度和湿度 D、应力 10、《公路桥规》中规定了用于公路桥梁承重部分混凝土标号分为( )等级。 A、8 B、10 C、12 D、13 11、在按极限状态理论计算钢筋混凝土构件承载力时,对于有明显流幅的钢筋,原则上都是以( )作为钢筋强度取值的依据 A、屈服极限 B、比例极限 C、弹性极限 D、抗拉极限强度 12、对于无明显流幅的钢筋,结构设计时原则上都是以( )作为钢筋强度取值的依据 A、比例极限 B、条件屈服强度 C、弹性极限 D、抗拉极限强度 13、钢筋和混凝土材料的强度设计值( )强度标准值。 A、等于 B、小于 C、大于 D、不确定 14、钢筋的塑性变形性能通常用( )来衡量。 A、屈服极限和冷弯性能 B、比例极限和延伸率 C、延伸率和冷弯性能 D、抗拉极限强度和延伸率

某超限高层住宅结构设计

某超限高层住宅结构设计 摘要:本文针对广州某超限高层住宅结构设计进行研究,介绍了该工程超限情况及有针对性的构造加强措施。采用了satwe和midas两种软件进行结构整体分析,用pkpm进行静力弹塑性分析(pushover)及弹性时程分析。结果表明结构在罕遇地震下处于延性阶段,结构抗震性能满足规范要求。 关键词:超限高层;静力弹塑性分析;弹性时程分析;构造加强措施 abstract:in this paper,the research on some exceeding high-rise residential building,which locates in guangzhou,is discussed.the code exceeding status and the structural reinforcing measures are introduced.two types of software,satwe and midas,were used for the global analysis,and pkpm was used for pushover analysis and elastic time-history analysis.the results shows that the structure is in ductile stage under rare earthquake,the seismic performance of the structure can satisfy the code requirements. key words: code exceeding high-rise building;pushover analysis;elastic time-history analysis;structural reinforcing measures 中图分类号;tu2文献标识码:a 文章编号:

探讨复杂高层与超高层建筑结构设计要点

探讨复杂高层与超高层建筑结构设计要点 随着我国城市化进程的发展,越来越多的人口聚集到城市,为了利用有限的空间解决人口容量,使城市压力得到缓解,逐渐增多了复杂高层与超高层建筑。在这一现象下,相关人员应重视结构设计,以保障建筑使用安全。 标签:复杂高层;超高层;建筑结构;设计要点 近年来城市土地资源非常稀缺,建筑工程逐步向着复杂高层和超高层方向发展,因此结构设计越来越难,作为设计人员必须和实际工程相结合,加强自身相关专业技术,加强分析和理解设计规范,从而更好的设计建筑结构,让客户认可并得到市场青睐。 1 与普通高层建筑结构设计的区别 在结构设计过程中,复杂高层和超高层与普通高层有着很大的差别,在一般情况下普通高层建筑其高度不会超过200米,而相对来说复杂高层与超高层建筑其高度通常不会低于200米,更甚者其高度会达到上千米左右。除此之外,通常情况普通高层建筑都是钢筋混凝土结构,而复杂高层与超高层建筑则是钢结构和混合结构类型。另外在合计阶段中,复杂高层与超高层建筑结构需要对抗震情况、缝荷载能力、避免层次以及环境等因素进行综合性考虑。从这些情况中我们可以看出,在结构设计上复杂高层与超高层建筑有更大的难度[1]。 2 结构设计控制要素 2.1 地基基础。地基基础质量影响着复杂高层和超高层建筑其整体稳定性,在设计地基结构时,要各种地基形态和设计标准进行全面考虑,以实际情况进行出发,只有这样才可以设计出更好的方案。在对软地基进行施工时,应使用桩箱和桩筏基础,并对根据不同地质制定出相应的措施使地基强度得到强化。当深层岩基进入地下100米以下时,可使用连续墙将地基巩固,当采用年轻且浅的岩基时,可将混凝土桩基加进去增加其支撑强度,当地基很好时采取筏形基础[2]。 2.2 重力荷载。复杂高层和超高层建筑会随着高度的攀升,增加地面受力以及重力荷载,增加墙上轴压力和竖向构件压力,使复杂高层和超高层建筑困难性加大。另外,随着楼层高度的上升会加大高风效应,在风的影响下合力点就会越高,从而加大自然风效应。在建筑结构设计过程中,结构自重关系着建筑稳定性,而结构自重又和重心位置有关,重心位置会随着楼层的升高而升高,从而加大结构自重,其强度就会非常薄弱。 2.3 风振加速。建筑楼层的高低关系着风力的大小,在一般情况下楼层越高时风力越强,因此超高层建筑有着非常明显的风力作用。但人们能够感知到风的舒适度,当风振太强时人们就会有不适感,使居住品质得到下降。在这种情况下,在设计复杂高层和超高层建筑结构时,需要将这些问题考虑进去,一定要控制好

超限高层建筑工程界定标准

超限高层建筑工程界定标准 根据国家建设部《超限高层建筑工程抗震设防审查技术要点》确定的超限高层建筑工程界定标准,结合我省实际予以细化,归纳整理如下: 一、房屋高度超过以下规定的高层建筑属于超限高层建筑 (一)现浇钢筋混凝土房屋适用的最大高度(M) 结构类型烈度 6 7 8 9 框架60 55 45 25 框架-抗震墙130 120 100 50 抗震墙140 120 100 60 部分框支抗震墙120 100 80 不应采用 框架-核心筒150 130 100 70 筒中筒180 150 120 80 板柱-抗震墙4 0 35 30 不应采用 注:1、房屋高度指室外地面到主要屋面板板顶的高度(不包括局部突出屋顶部分); 2、框架-核心筒结构指周边稀柱框架与核心筒组成的结构; 3、部分框支抗震墙结构指首层或底部两层框支抗震墙结构; 4、乙类建筑可按本地区抗震设防烈度确定适用的最大高度; 5、超过表内高度的房屋,应进行专门研究和论证,采取有效的加强措施。 (以上摘自《建筑抗震设计规范》表6.1.1) 《建筑抗震设计规范》第6.1.1条还规定:平面和竖向均不规则的结构或建造于Ⅳ类场地的结构,适用的最大高度应适当降低(规范条文说明规定“一般降低20%左右”)。 (二)钢结构房屋适用的最大高度(M) 结构类型6、7度8度9度 框架110 90 50 框架-支撑(抗震墙板)220 200 140 筒体(框筒、筒中筒、桁架筒、束筒)和 巨型框架300 260 180 注:1、房屋高度指室外地面到主要屋面板板顶的高度(不包括局部突出屋顶部分); 2、超过表内高度的房屋,应进行专门研究和论证,采取有效的加强措施。(以上摘自《建

某超限高层结构抗震设计

某超限高层结构抗震设计 [摘要]主要介绍了某b级高度超高层办公楼项目的结构布置,抗震计算分析及结构概念设计。针对其超高的超限特点,采用基于性能的抗震设计,经多模型,多软件的弹性比较分析及动力弹塑性补充计算,保证设计能够覆盖结构的各种实际受力状态。使结构的抗震性能满足规范及性能目标的要求。 [关键词]超限高层; 抗震性能目标; 弹性分析; 动力弹塑性分 析 中图分类号:tu241.8 文献标识码a 文章编号 seismic design of exceed-limit tall building of a project gao fei (huasen architecture & engineering design consultants ltd.,shenzhen 518054) abstract: the structure plan, the seismic analysis and the seismic fortification measures of a project is described in the article. for the exceed-limit height, performance based seismic design was adopted, and the elastic analysis of multi-models using different programs and the static elastic-plastic analysis are given to ensure all the potential states of loading are enveloped. some specific constructional measures are taken to assure the design meets the performance objectives.

结构设计原理习题-练习

《结构设计原理》复习题 一、填空 1.按加工方式不同,钢筋分为()、()、()、()四种。2.()与()通常称为圬工结构。 3.梁内钢筋主要有()、()、()、()等。 4.随着柱的长细比不同,其破坏型式有()、()两种。 5.根据张拉预应力筋与浇筑混凝土构件之间的先后顺序,预应力混凝土分为()、()两类。 6.钢筋与混凝土之间的粘结力主要有以下三项组成()、()、()。7.按照配筋多少的不同,梁可分为()、()、()三种。 8.钢筋混凝土受弯构件主要有()和()两种形式。 9.梁内钢筋主要有()、()、()、()等。 10.()、()、()称为结构的可靠性。 11.钢筋的冷加工方法有()、()、()三种。 12.结构的极限状态,根据结构的功能要求分为()、()两类。 13.T形截面梁的计算,按()的不同分为两种类型。 14.在预应力混凝土中,对预应力有如下的要求()、()、()。15.钢筋混凝土梁一般有()、()、()三种不同的剪切破坏形式。16.预应力钢筋可分为()、()、()三种。 二、判断题:(正确的打√,错误的打×。) 1.混凝土在长期荷载作用下,其变形随时间延长而增大的现象称为徐变。()2.抗裂性计算的基础是第Ⅱ阶段。()3.超筋梁的破坏属于脆性破坏,而少筋梁的破坏属于塑性破坏。()4.增大粘结力、采用合理的构造和高质量的施工、采用预应力技术可以减小裂缝宽度。()5.当剪跨比在[1, 3]时,截面发生斜压破坏。. ()6.预应力损失是可以避免的。()7.整个结构或结构的一部分,超过某一特定状态时,就不能满足结构功能的要求,这种特殊状态称为结构的极限状态。()8.箍筋的作用主要是与纵筋组成钢筋骨架,防止纵筋受力后压屈向外凸出。() 9.采用预应力技术可杜绝裂缝的发生或有效减少裂缝开展宽度。()10.为了保证正截面的抗弯刚度,纵筋的始弯点必须位于按正截面的抗弯计算该纵筋的强度全部被发挥的截面以内,并使抵抗弯矩位于设计弯矩图的里面。()11.偏心距增大系数与偏心距及构件的长细比有关。()12.钢筋混凝土梁的刚度是沿梁长变化的,无裂缝区段刚度小,有裂缝区段刚度大。()13.钢筋按其应力应变曲线分为有明显流幅的钢筋和没有明显流幅的钢筋。()14.因为钢筋的受拉性能好,所以我们只在受拉区配置一定数量的钢筋而在受压区不配置钢筋。()15.当轴向力的偏心较小时,全截面受压,称为小偏心受压。() 越大越好。()16.有效预应力 pe

【结构设计】超限高层结构设计优化要点汇总(干货!)

超限高层结构设计优化要点汇总(干货!) 随着经济的发展,我国的高层建筑越来越多,越来越高,各大城市的地标建筑也多以超高层建筑为主.然而,超限高层建筑的专项审查工作往往占据了设计阶段的大量时间,且其直接奠定了后期的结构造价.在此分享关于超限高层项目的优化要点. 一、什么是超限高层建筑工程? 超限高层建筑工程是指超出国家规范、规定所规定的适用高度和适用结构类型的高层建筑工程,体型特别不规则的高层建筑工程,以及有关规范、规程规定应当进行抗震专项审查的高层建筑工程. 具体判别标准详见《超限高层建筑工程抗震设防专项审查技术要点》建质【2015】67号. 需要注意的是,对于一些处于超限与否边界附近的建筑工程最好提前与审图机构,审查专家提前沟通好是否需要进行超限审查,以免造成时间上的延误. 二、超限高层结构计算若干优化要点 (1)结构体系

结构体系的选取需经过严格比选.常见的各种结构体系优缺点如下表所示: 结构体系优点缺点 混凝土框架+核心筒造价经济、施 工方便自重大、截面大、浪费空间 型钢混凝土框架+核心筒结构抗震性能 优良 造价高 钢管混凝土柱+核心筒延性延性好;柱截 面较小 造价高于型钢混凝土最终采用何种体系可综合考虑时间成本、施工成本、经济效益等方面. (2)风速剖面与风振分析 《高规》4.2.7条规定:房屋高度大于200m或有下列情况之一时,宜进行风洞试验判断确定建筑物的风荷载: I.平面形状或立面形状复杂; II.立面开洞或连体建筑 III.周围地形和环境较复杂. 超限高层建筑分为高度超限和不规则性超限,所以往往需要进行风洞试验. 由于风具有明显的地域性,且其强度和方向具有显著的方向性,利用这些特点可以有效降低结构和幕墙的造价.对于高度超过300~400m的超高层建筑,风沿高度方向变化的特性对结构设计影响很大,因此针对具体工程确定适用的最优风速剖面,而不仅依赖于《荷载规范》提供的指数变化曲线,能够有效降低风力作用,取得显著的经济效益.

华东院结构设计培训内部资料--超限高层抗震设计指南

编制依据 《建筑抗震设计规范》送审稿 《高层建筑混凝土结构技术规程》 (征求意见稿) 《超限高层建筑工程抗震设防管理规定》 (建设部令第111号) 《上海市超限高层建筑设防管理实施细则》 (沪健 【2003】702号) 广东省实施《高层建筑混凝土结构技术规程》 (jgj3‐2002)补充规定 江苏省《房屋建筑工程抗震设防审查细则》 《超限高层建筑工程抗震设防专项审查技术要点》(建质【2006】220号) 《关于加强超限高层建筑抗震设防审查工作的建议》 (2007年工作会议) 《关于加强超限高层建筑工程抗震设防审查技术把关的建议》 (2009年2月6号) 《超限高层建筑抗震工程抗震设计指南》 (第二版吕西林主编) 超限的认定 《超限高层建筑工程抗震设防专项审查技术要点》 建质【2006】220号 新抗震规范及高层混凝土结构规范推出后,其划分范围作相应调整 将大跨结构纳入审查 将市政工程纳入审查 CECS如与抗规及高规矛盾,以高规及抗规为主 上海工程还需满足《上海市超限高层建筑设防管理实施细则》 (沪建建【2003】702号) 计算分析总体要求 总体判断,根据受力特点建模 计算参数选取要合理 计算假定要符合实际受力 计算结果应进行分析判断 计算参数的选取 连梁的单元形式(杆单元或壳) 巨柱采用杆或壳单元 墙单元最大单元尺寸 楼板单元是否合理 阻尼比的选择 连梁刚度的折减 周期折减系数 最不利地震方向(正方形增加45°) 最不利风荷载方向 施工模拟的方式 嵌固端的选取 特殊构件的定义 足够的振型数量 是否考虑p‐△效应 考虑偶然偏心 混凝土柱的计算长度系数(地下室、悬臂梁)

高层建筑结构设计考试试题(含答案)

高层建筑结构设计考试试题一、填空题( 2× 15=30) 1、2、钢筋混凝土剪力墙结构的水平荷载一般由剪力墙承担,竖向荷载由剪力墙承担。其整体位移曲线特点为弯曲型,即结构的层间侧移随楼层的 而增大而增大。与框架结构相比,有结构整体性好,刚度大,结构高度可 以更大。等优点。 框架——剪力墙结构体系是把框架和剪力墙结构两种结构共同结合在一起形成的结构体系。结构的竖向荷载由框架和剪力墙承担,而水平作用主要由 剪力墙承担。其整体位移曲线特点为弯剪型,即结构的层间位移在结构底部层间位移随层数的增加而增大,到中间某一位置,层间位移随 层数的增加而增大。 3、框架结构水平荷载作用近似手算方法包括反弯点法、D值 4、 法。当结构的质量 中心下会发生扭转。 中心和刚度中心中心不重合时,结构在水平力作用 二、多项选择题(4×5= 20) 1、抗震设防结构布置原则(ABC) A 、合理设置沉降缝C、 足够的变形能力B D 、合理选择结构体系 、增大自重 E、增加基础埋深 2、框架梁最不利内力组合有(AC) A、端区 -M max, +M max, V max C、跨中 +M max D B、端区 M max及对应 N, V 、跨中 M max及对应 N, V E、端区N max及对应M, V 3、整体小开口剪力墙计算宜选用( A )分析方法。 A、材料力学分析法 B、连续化方法 C、壁式框架分析法 D、有限元法 4、高层建筑剪力墙可以分为(ABCD )等几类。 A、整体剪力墙 B、壁式框架 C、联肢剪力墙 D、整体小开口墙 5、高层建筑基础埋置深度主要考虑(ACD)。 A、稳定性 B、施工便利性 C、抗震性 D、沉降量 E、增加自重 三、简答题(7×5= 35) 1、试述剪力墙结构连续连杆法的基本假定。 1、剪力墙结构连续连杆法的基本假定:忽略连梁的轴向变形,假定两墙肢的水平位移完全相同;各墙肢截面 的转角和曲率都相等,因此连梁两端转角相等,反弯点在中点;各墙肢截面,各连梁截面及层高等几何尺寸 沿全高相同。

结构设计原理练习题C

结构设计原理练习题C 一、单项选择: 1、下列破坏形态中属于延性破坏的是: ( ) A :超筋梁的破坏 B :剪压破坏 C :适筋梁的破坏 D:小偏心受压破坏 2、轴心受压柱中箍筋的主要作用是: ( ) A :抗压 B :约束钢筋不屈曲 C :抗剪 D : 防裂 3、同截面尺寸、同种材料的梁,只是钢筋用量不同,则承载能力关系:( ) A :超筋梁>适筋梁>少筋梁 B :适筋梁>超筋梁>少筋梁 C :少筋梁>适筋梁>超筋梁 D :超筋梁>少筋梁>适筋梁 4、螺旋式间接钢筋的体积配筋率为 ( ) 0: s A A bh :sv v A B bs 11111112:s s n l A n l A C l l s + 14:ss cor A D d s 5、截面尺寸满足抗剪上限要求则不会发生: ( ) A :剪压破坏 B :斜拉破坏 C :斜压破坏 D :少筋破坏 6、先张法特有的应力损失是 ( ) A :钢筋与孔道摩擦引起的应力损失 B :台座与钢筋温差引起的应力损失 C :钢筋松弛引起的应力损失 D :混凝土收缩引起的应力损失 7、部分应力构件的预应力度: ( ) A :0=λ B :0λ< C :1>λ D :10<<λ 二、填空 1、构件按受力特点分 、 、 、受扭构件。 2、混凝土的强度设计值是由强度标准值 而得。 3、结构能满足各项功能要求而良好的工作叫 ,否则叫 。 4、 < f sd A s 时定义为第二类T 梁。 5、由于某种原因引起预应力钢筋的应力减小叫 。 三、判断正误 1、剪压破坏是延性破坏而斜拉破坏是脆性破坏。 ( ) 2、在轴心受压件中混凝土的收缩和徐变都会引起钢筋的压应力增长。 ( ) 3、ηe 0 >0.3h 0 时为大偏心受压。 ( ) 4、施加预应力不能提高构件的承载能力。 ( ) 5、局部承压面下混凝土的抗压强度比全截面受压时高。 ( ) 四、简答 1、什么叫开裂截面的换算截面?为什么使用换算截面?画矩形截面全截面换算截面的示意图。 2、 钢筋和混凝土之间的粘结力来源于哪几方面? 3 、简述后张法施工过程?它有哪些优、缺点? 4、简述等高度梁只设箍筋时的抗剪钢筋设计步骤。 五、计算题 1、T 形截面尺寸' '1200,200, 120,1000,f f b mm b mm h mm h mm ====采用C30混凝 土(MPa f cd 8.13=),HRB335级钢筋(MPa f sd 280=),Ⅰ类环境条件,56.0=b ξ,

中旅城二期南楼超限高层结构设计

中旅城二期南楼超限高层结构设计

中旅城二期南楼超限高层结构设计 胡贤忠( 福州国伟建设设计有限公司 福建福州 350001) [摘 要结构设计提出了严峻挑战。本论文介绍此超限结构的抗震和抗风设计,进行了不同力学模型的多种软件静力对比分析、弹性时程 中 震 作用并对控制结构的扭转效应和计算中部分构件的超筋信息的做了研究处理; 同时对型钢混凝土转换结构和连体的设计做了论 述, 并介绍了其节点的构造设计。 South - t o w e r s t r u c t u r e d e s i g n of s up e r h i r e - r i s e building of CTS second - ph a s e A b s t r a c li m it s o f t h i s bu il d i n g w e r e a n a l y z e d ,a nd t h e r e l eva n t s o l u ti o n s c h e m e s w e r e p r o p o s e d . A cco r d i n g t o t h e co m p a r i s o n on t h e a n a l y s i s r e s u lt s o f t h e t h r ee p r og r a m s ,e l a s ti c ti m e - h i s t o r y a n a l y s i s ,m e d i u m ea r t hqu a k e e ff ec t a n a l y s i s ,pu s h - o ve r a n a l y s i s ,s t r u c t u r a l s y s t e m acco r d i n g t o d iff e r e n t p a r t s a d o p t co rr e s p o nd i n g t o t h e va r i o u s t y p e s o f co m b i n a ti o n co m p o n e n t t o s a ti s f y s tiff n e ss ,du c tilit y and r e dund a n cy . The key p o i n t s o f t h i s s t r u c t u r e as w e ll as i m p o r t a n t s eg m e n t s w e r e a n a l y z e d and d i s c u ss e d . Key words : u lt r a li m it e d h i g h - r i s e bu il d i n g ; s e i s m i c d e s i g n ; t o r s i o n a l e ff ec t ; co m p o s it e s t r u c t u r e ; p e r f o r m a n ce based s e i s m i c d e s i g n 1 工程概况 中旅城二期座落在福州市金融文化中心五四路的黄金位 置,其由南楼、北楼、办公楼和高档商业裙房组成的大型商住 楼。南楼、北楼、办公楼和裙房在地面以上用抗震缝分开。南 楼建筑高度 149. 85m ,地面八层高位转换的连体建筑,其立面 效果图如图 1; 地下二、三、四层为车库及设备用房,地下一层 至七层为高 档 商业 中 心,在 七 ~ 八层设一 5. 6m 高的物业会所,其上至四十四层 为 住 宅,建 筑 立 面 如 图 2 所示。 本项目设计所依据规 范 版 本 为 2000 年 系 列。结 构 体 系 为框 支剪力墙转换层以下为型钢混凝土柱 + 钢筋混凝 土核心筒,转换层以上为钢筋混凝土剪力墙结构,连体为强连 接的钢桁架。结构设计基准期为 50 年,结构安全等级为二 级; 抗震设防烈 度 为 7基准 期为 100 年 2 超限情况及抗震性能目标 2. 1 超限判定 依据《全国超限高层建筑工程抗震设防专项审查技术要 点》相关规定进行超限判定。 ( 1) 塔楼高度为近 150m ,超过了“高规”所规定的框支剪 力墙结构适用的 B 级 最 大 高 度,超 限 幅 度 为 25% ; 判 定 为 超 限。 图 1 南楼立面效果图 ( 2) 转换层位于七层顶 ( 34. 45 米) ,超 过 了《高 规》第 10 章中“7 度不超过 5 层”的规定,属高 位 转 换; 为 一 项 不 规 则, 判定为超限。

超限高层结构设计内容

超限高层建筑工程抗震设防专项审查技术要点 第一章总则 第一条为做好全国及各省、自治区、直辖市超限高层建筑工程抗震设防专家委员会的专项审查工作,根据《行政许可法》和《超限高层建筑工程抗震设防管理规定》(建设部令第111号),制定本技术要点。 第二条下列工程属于超限高层建筑工程: (一) 房屋高度超过规定,包括超过《建筑抗震设计规范》(以下简称《抗震规范》)第6章钢筋混凝土结构和第8章钢结构最大适用高度、超过《高层建筑混凝土结构技术规程》(以下简称《高层混凝土结构规程》)第7章中有较多短肢墙的剪力墙结构、第10章中错层结构和第11章混合结构最大适用高度的高层建筑工程。 (二) 房屋高度不超过规定,但建筑结构布臵属于《抗震规范》、《高层混凝土结构规程》规定的特别不规则的高层建筑工程。 (三) 房屋高度大于24米且屋盖结构超出《网架结构设计与施工规程》和《网壳结构技术规程》规定的常用形式的大型公共建筑工程(暂不含轻型的膜结构)。 超限高层建筑工程的主要范围参见附录一。 第三条在本技术要点第二条规定的超限高层建筑工程中,属于下列情况的,建议委托全国超限高层建筑工程抗震设防审查专家委员 —1—

会进行抗震设防专项审查: (一) 高度超过《高层混凝土结构规程》B级高度的混凝土结构,高度超过《高层混凝土结构规程》第11章最大适用高度的混合结构; (二) 高度超过规定的错层结构,塔体显著不同或跨度大于24m的连体结构,同时具有转换层、加强层、错层、连体四种类型中三种的复杂结构,高度超过《抗震规范》规定且转换层位臵超过《高层混凝土结构规程》规定层数的混凝土结构,高度超过《抗震规范》规定且水平和竖向均特别不规则的建筑结构; (三) 超过《抗震规范》第8章适用范围的钢结构; (四) 各地认为审查难度较大的其他超限高层建筑工程。 第四条对主体结构总高度超过350m的超限高层建筑工程的抗震设防专项审查,应满足以下要求: (一) 从严把握抗震设防的各项技术性指标; (二) 全国超限高层建筑工程抗震设防审查专家委员会进行的抗震设防专项审查,应会同工程所在地省级超限高层建筑工程抗震设防审查专家委员会共同开展,或在当地超限高层建筑工程抗震设防审查专家委员会工作的基础上开展; (三) 审查后及时将审查信息录入全国重要超限高层建筑数据库,审查信息包括超限高层建筑工程抗震设防专项审查申报表项目(附录二)和超限高层建筑工程抗震设防专项审查情况表(附录三)。 第五条建设单位申报抗震设防专项审查的申报材料应符合第二章的要求。专家组提出的专项审查意见应符合第六章的要求。 —2—

混凝土结构设计原理试卷之计算题题库 ()

1、某现浇多层钢筋混凝土框架结构,地层中柱按轴心受压构件计算,柱高H=6.4m ,承受轴向压力设计值N=2450kN,采用C30级混凝土,HRB335级钢筋,求柱截面尺寸(设配筋率 '0.01,1ρ?==),并试计算需配置的纵向受力钢筋。 (已知:2 14.3N/mm c f =,21.43/t f N mm =,'2300/y y f f N mm ==) 附表:钢筋混凝土轴心受压构件的稳定系数? 设配筋率' 0.01,1ρ?==,由公式知 正方形截面边长396.7b mm ==,取b=400mm 。 (2)求稳定系数 柱计算长度0 1.0l H =, 06400 16400 l b ==,查表得0.87?=。 (3)计算配筋 由公式知 2、某梁截面尺寸b×h=250mm×500mm ,M=2.0×108N·mm ,受压区预先已经配好HRB335级受压钢筋2φ20(' s A =628mm 2 ),若受拉钢筋也采用HRB335级钢筋配筋,混凝土的强度等级为C30,求截面所需配置的受拉钢筋截面面积s A 。 (已知:2 14.3N/mm c f =,21.43/t f N mm =,'2300/y y f f N mm ==,1 1.0α=, ,max 0.55,0.399b s ξα==) 解:(1)求受压区高度x 假定受拉钢筋和受压钢筋按一排布置,则' 35mm s s a a == 且' 2235mm 70mm s x a >=?= (2)计算截面需配置的受拉钢筋截面面积 四、计算题 1、已知某屋架下弦,截面尺寸b=220mm ,h=150mm ,承受轴心拉力设计值N=240kN ,混凝土为C30级,纵筋为HRB335级,试计算需配置的纵向受力钢筋。 (已知:2 14.3N/mm c f =,21.43/t f N mm =,'2300/y y f f N mm ==) 参考答案: 解:,u N N =令 2、已知梁的截面尺寸b=250mm ,h=500mm ,混凝土为C30级,采用HRB400级钢筋,承

相关文档
最新文档