1主题内容The subject content (2)

2适用范围Application scope (2)

3参考文件Reference documents (2)

4人员资格Personnel qualification (3)

5 设备要求Equipment requirements (3)

6 探头Probe (4)

7 试块Test block (4)

8设备仪器校验Instrument calibration of equipments (6)

9探头校准和耦合剂Probe calibration and coupling (6)

10距离-波幅曲线(DAC曲线)Distance Amplitude Curve (6)

11校验与复核Verifying and rechecking (8)

12 检测程序Testing procedures (9)

13 评定Assessing (17)

14 记录Records (19)

15 报告Report (19)

附录Appendix (19)

1主题内容The subject content

本工艺流程规定了本司船舶产品超声检测的一般要求、技术等级、工艺文件、检测实施和焊缝质量分级等。

This regulation provides the general requirements, technical levels, process documents, test implementation and welding quality classification of ultrasonic testing on our company.

2适用范围Application scope

本工艺流程适用于本司造船、修船及非船产品零部件母材厚度为(8~150)mm铁素体钢全熔焊透缝A型脉冲反射式手工接触的超声波检测;不适用于铸钢及奥氏体钢焊缝,外径<250mm和内外径之比<70%的纵向焊缝;外径小于200mm的筒体周向焊缝、各种尺寸曲面相贯焊缝。

This regulation is applicable to A type pulse reflection type of manual contact ultrasonic testing for 8~150mm thickness of ferrite steel complete fusion welding on our company’s shipbuilding, repairing and parts of no-marine products. No applicable to cast steel and austenitic steel welds, longitudinal weld of outer diameter less than 250mm and the inner and outer diameter ratio less than 70%, column ring weld of outside diameter less than 200mm; various size of bend surface joining welds.

3参考文件Reference documents

3.1 JB/T4730-2005 《压力容器无损检测》超声波检测部分;

3.1 JB/T4730-2005 The ultrasonic detection part of "nondestructive testing of pressure vessels".

3.2中国船级社无损检测超声检测教材

3.2 The ultrasonic textbook compiled by CCS.

3.3 JB4126《超声检测用钢质试块的制造和控制》

3.3 JB4126 "The manufacture and control of steel test piece for ultrasonic testing".

3.4 ZBJ04001《A型脉冲反射式超声波探伤系统工作性能测试方法》

3.4 ZBJ04001 "The performance test methods of A type pulse reflection ultrasonic flaw detection system".

3.5 ZBY230《A型脉冲反射式超声波探伤仪通用技术条件》

3.5 ZBY230 "General technical conditions of A type pulse reflection ultrasonic testing instrument".

3.6 ZBY232《超声波探伤用1号标准试块技术条件》

3.6 ZBY232 "Technical conditions of 1 type standard test piece for ultrasonic testing".

3.7 ZBY231《超声波探伤用探头性能测试方法》

3.7 ZBY231 "The performance test methods of probe for ultrasonic inspection".

3.8 CB/T3959-2011《船舶钢焊缝超声波检测工艺和质量分级》

3.8 CB/T3959-2011 "Technology and quality classification of ultrasonic testing in ship steel weld".

3.9 DNV入级指导No.7中超声检测部分

3.9 The ultrasonic detection part of joining DNV direction No.7.

3.10 CTS-4020数字式超声波探伤仪使用说明书

3.10 The direction of CTS-4020 digital ultrasonic testing instrument.

4人员资格Personnel qualification

4.1从事无损检测的人员必须经过专业技术培训,并按照中国船级社《无损检测人员资格鉴定与认证规范》进行资格考核,取得资格证书后只能从事与其证书所注明的方法与级别相适应的无损检测工作;

4.1 The NDT personnel must through professional technical training and qualification examination according to the CCS "nondestructive testing personnel qualification and certification standard”, and only can deal with the nondestructive testing work adapt to the method and level indicated in qualification certificate.

4.2Ⅰ级人员可在Ⅱ、Ⅲ级人员指导下进行无损检测操作,记录检测数据,整理检测资料;

4.2 Ⅰlevel personnel can nondestructive testing operation, record test data, establish inspection documents under guidance of Ⅱ, Ⅲ level personnel.

4.3Ⅱ级人员可编制一般的无损检测程序,按照无损检测工艺规程或在Ⅲ级人员指导下编写工艺卡,并按无损检测工艺独立进行检测操作,评定检测结果,签发检测报告;

4.3 Ⅱ level personnel can compile the ordinary testing procedures of the nondestructive testing, according to nondestructive testing procedure or under the guidance of Ⅲlevel personnel to write the process card, and independent test according to nondestructive testing regulation, assess the test results, and issue the test report.

4.4Ⅲ级人员可根据标准编制无损检测工艺,审核或签发检测报告,协调Ⅱ级人员对检测结论的技术争议。

4.4. Ⅲlevel personnel can compile the nondestructive testing procedures according to standard, review or issue inspection report, harmonize the test results dispute from Ⅱ level personnel.

5 设备要求Equipment requirements

5.1现使用的仪器见表1

5.1 Now using equipments see table 1.

5.2 仪器的工作频率范围一般为0.5~10MHz。

5.2 The operating frequency range of instrument general is 0.5~10MHz.

5.3仪器和探头的组合灵敏度:在达到所检工件最大声程时,其灵敏度余量应不小于10dB,且电噪声电平不大于垂直满刻度的20%。

5.3 Combination sensitivity of instrument and probe: Reaching the maximum beam path of work piece, the surplus sensitivity shall be not less than 10dB, and electrical noise level is not greater than 20% of vertical full scale.

5.4衰减器精度:总增益量不小于80db,最小步进每档不大于2db;任意相邻12dB误差在±1dB以内,最大累计误差不超过1dB。

5.4 Attenuator accuracy: the total plus amount is not less than 80dB, the smallest step is not more than 2dB; any adjacent 12dB error is less than ± 1dB, maximum accumulated error is not more than 1dB.

5.5水平线性:水平线性误差不大于1%。

5.5 Horizontal linearity: horizontal linearity is not more than 1%.

5.6垂直线性:在荧光屏满刻度的80%范围内呈线性显示;垂直线性误差不大于5%。

5.6 Vertical linearity: linear displayed in 80% of full screen; vertical linearity is not more than 5%.

表1:Table 1

6 探头Probe

6.1晶片有效面积除另有规定外一般不应超过500mm2,且任意一边长不大于25mm。

6.1 Wafer area unless otherwise specified general should not exceed 500mm2, and any side length is not more than 25mm.

6.2单斜探头声束轴线水平偏离角不应大于2°,主声束垂直主方向不应有明显的双峰。

6.2. The beam axis horizontal deviation angle of single oblique probe should not exceed 2°, the main perpendicular direction of main beam should not have obvious double wave crests.

6.3直探头的远场分辨力应大于或等于26dB,斜探头的远场分辨力应大于或等于6dB。

6.3 The far field differentiation ability of straight probe should no less than 26dB, oblique probe should no less than 6dB.

6.4仪器和探头的系统性能应按JB/T9214的规定进行测试。

6.4 The system performance of instrument and detector shall be tested according to the provisions of JB/T9214.

7 试块Test block

7.1试块应采用与被检工件相同或近似声学性能的材料制成,该材料用直探头检测时,不得有大于Φ2mm平底孔当量直径的缺陷。

7.1 Test block shall be made by the material with same or similar acoustic capability to the inspected work piece, when this material tested with straight probe, there shall not have defects that equivalent diameter of flat-bottomed hole larger than Φ2mm.

7.2试块的制造要求应符合ZBY232和JB4126的规定。

7.2 The production requirements of test block shall be in accordance with the rules of ZBY232 and JB4126.

7.3现场检测时,也可采用其它型式的等效试块

7.3 At field detection, can also use other types of equivalent test blocks.

7.4采用的标准试块为IIW或CSK-ⅠA.其中CSK-ⅠA标准试块其形状和尺寸如图1。

7.4 The standard test block is IIW or CSK-ⅠA. The shape and size of CSK-ⅠA standard test block is shown in figure 1.

图1 CSK-IA 试块 Figure 1 Test block of CSK-IA

7.5对比试块分别为CTRB-1,CTRB-2,CTRB-3三种形式,其中CTRB -2型的形状、尺寸如图2所示

7.5 The contrast test blocks are three types of CTRB-1, CTRB-2, CTRB-3. The shape and size of CTRB-2 is shown in Figure 2

7.6检测曲面工件时,如检测面曲率半径R 小于等于W 2/4(W 为探头接触面宽度,环缝检测时为探头宽度,纵缝检测时为探头长度)时,应采用与检测面曲率相同的对比试块。一个对比试块可检其直径0.9~1.5倍的工件。

7.6 When inspecting curved surface work piece, if the curvature radius R of detection surface is not more than W2/4 (W is probe contact surface width, as probe width in ring seam testing, probe length in longitudinal seam testing), should using the contrast test block with the same curvature radius. A contrast test block can check the work pieces with 0.9~1.5 times diameter

.

图2 CTRB -2试块 Figure 2 CTRB -2

8设备仪器校验Instrument calibration of equipments

在仪器开始使用时,应对仪器的水平线性进行测定,测定方法按ZBY230的规定进行。在使用过程中,仪器维修后及每隔三个月至少应对仪器的水平线和垂直线性进行一次校准。

According to the provisions of ZBY230, the horizontal linearity should be mensurated before using the equipment. During using time, after repaired or every three months should calibrate the horizontal and vertical linearity for one time at least.

9探头校准和耦合剂Probe calibration and coupling

在探头开始使用时,应对探头进行一次全面的性能校准。测定方法应按ZBY231的有关规定进行。

Before using the probe, should have a comprehensive performance calibration. The calibration method should be according to the relevant provisions of ZBY231.

9.1斜探头校准Calibration of oblique probe

使用前,斜探头至少应进行前沿距离、K值、主声束偏离、灵敏度余量和分辨力等的校准。使用过程中,每个工作日应校准前沿距离、K值和主声束偏离。

Before use, oblique probe should be calibrated at least for forward distance, K value, main beam deviation, surplus sensitivity and differentiation ability. At the using time, each work day should be calibrated forward distance, K value and main beam deviation.

9.2直探头校准Calibration of straight probe

直探头的灵敏度余量和分辨力应每隔一个月检查一次。

The surplus sensitivity and differentiation ability of straight probe should be inspected one time for every month.

9.3耦合剂应具有良好的透声性能和适当的粘度,并对被检工件和人体无害,检测后容易清洗。甘油、75%以上甘油溶液、水、机油、浆糊或相似声阻抗的液体均可作为耦合剂。

9.3 The coupling should have good sound transmission performance and proper viscosity, and harmless to the inspected work piece and human body, easy cleaning after detection. Glycerol, more than 75% glycerol solution, water, oil, paste or similar acoustic impedance of the liquid can be used as coupling agent.

10距离-波幅曲线(DAC曲线)Distance Amplitude Curve

10.1距离一波幅曲线的绘制

10.1 Distance amplitude curve drawing

10.2距离一波幅曲线按所用探头和仪器在试块上实测的数据绘制而成,曲线的制作方法见超声波探伤仪使用说明书。该曲线族由评定线、定量线和判废线组成,评定线与定量线之间(包括评定线)为Ⅰ区,定量线与判废线之间(包括定量线)为Ⅱ区,判废线及其以上区为Ⅲ区。如图4所示。

10.2 DAC drawing according to the data of the probe and instrument testing in the test block. The methods of DAC drawing is shown in the using instructor of ultrasonic flaw detector. The family of curves make up of evaluating line, quantitative line and sentenced waste line, the area between quantitative and evaluation lines (including evaluating line) call for Ⅰ region, between quantitative and sentenced waste line (including quantitative line) call for II region, sentenced waste line and above call for Ⅲ region. As shown in figure 4.

10.3距离一波幅曲线的灵敏度选择

10.3 The selection of DAC sensitivity.

10.3.1根据被检焊缝母材厚度不同,其距离一波幅曲线灵敏度按表2的规定。

10.3.1 According to the different parent metal thickness of detected welds, the DAC sensitivity is shown in table 2.

10.3.2直探头的距离一波幅曲线灵敏度按表3的规定。距离一波幅曲线的制作可在CS2试块上进行。

10.3.2 The DAC sensitivity of straight probe is shown in table 3.Distance amplitude curve can be made on CS2 test block.

10.3.3检测横向缺陷时,应将各线灵敏度均提高6dB。

10.3.3 For the detection of transverse defects, each line’s sensitivity should enhanced 6dB.

10.3.4检测面曲率半径R小于或等于W2/4时,距离一波幅曲线的绘制应在曲面对比试块上进行。

10.3.4 When the curvature radius R of detection surface is not more than W2/4, distance

amplitude curve should be made on the contrast test block of curly surface.

图4 距离—波幅曲线Figure 4 the distance amplitude curve

10.3.5工件的表面耦合损失的材质衰减应与试块相同。

10.3.5 The loss of material attenuation on work piece surface coupling should be same to test blocks.

10.3.6扫查灵敏度不低于最大声程处的评定线灵敏度。

10.3.6 The scanning sensitivity is not less than evaluation line sensitivity at the maximum sound distance.

表2距离一波幅曲线的灵敏度Table 2 the DAC sensitivity 板厚mm 评定线测长线判废线

≤50

>50~100 >100 φ3-16dB

φ3-12dB

φ3-8dB

φ3-10dB

φ3-6dB

φ3-2

φ3

φ3+2dB

φ3+2dB

表3T型焊接接头直探头距离一波幅曲线的灵敏度

Table 3 The DAC sensitivity of straight probe on T welded joint

11校验与复核Verifying and rechecking

11.1每次检测开始前,应对仪器的水平线性和检测灵敏度进行校验。

11.1 Before testing, the horizontal linearity and detection sensitivity of instrument should be verified.

11.2在检测过程中,出现下列请况时,应对检测系统进行校验:

11.2 In the process of testing, when the following situations appear, the detection system

should be verified.

①校准后的探头、耦合剂和仪器调节旋钮发生改变时;

①When the verified probe, coupling matter and adjusting knob of apparatus have

change;

②检测人员怀疑水平线性或者扫查灵敏度有变化时;

②When the inspection personnel suspected of horizontal linear or scanning sensitivity have change;

③检测系统连续工作4h以上时;

③ When the detection system continuously operating above 4H;

11.3检测结束前,应对检测系统复核。

11.3 Before the ending of detection, the detection system should be rechecked.

11.3.1时基线的复核Rechecking of time baseline

每次检测结束前,应对时基线进行复核。如果时基线上任意一点的偏移超过时基线的10%,则应重新调节时基线,并对上一次复核以来所有的检测部位进行重新检测。

Before ending of each inspection, the time baseline should be rechecked. If the offset of any point on the time baseline more than 10% of the baseline, the time baseline should be readjusted, and all the detected position during the last time of rechecking should be afresh inspected.

11.3.2检测灵敏度(DAC曲线)的复核Rechecking of inspection sensitivity (DAC)

每次检测结束前,应对检测灵敏度(DAC曲线)进行复核。对DAC曲线)的复核不少于3点。如曲线上任何一点幅度下降2dB或2dB以上,则应对上一次复核以来所有的检测部位进行重新检测;如幅度上升2dB或2dB以上,则应对所有的检测记录进行重新评定。

Before ending of each inspection, the inspection sensitivity (DAC) should be rechecked. The rechecking of DAC not less than 3 points. If the amplitude of any point on the curve drop 2dB or 2dB above, all the detected position during the last time of rechecking should be afresh inspected; If the amplitude ascend 2dB or 2dB above, all the detected records should be afresh assessed.

11.4 在对检测系统进行校准、复核和线性测定时,任何影响仪器线性的控制器(如抑制或滤波开关等)应处于关闭状态或最低水平位置。

11.4 During the time of verifying, rechecking and linearity mensuration of the detecting system, any controller that influences the linearity of the instrument (e.g. inhibition or filter switch etc.) should be closed or at the minimum level position.

12 检测程序Testing procedures

12.1检测前的准备Preparation of test

12.1.1检测时机Detection time

一般材料焊缝冷却至室温后方可进行检测;有产生延迟裂纹倾向的材料,应在焊接完成至少24h后进行检测;有热处理要求的工件,应在热处理完成后检查。超声检测前,焊缝表面及热影响区应经外观检验合格。

When the general material weld cooling to room temperature can be detected; material have trend of delayed cracks, should be tested at least 24h after completed welding; the work piece have heat treatment requirements, should be tested after the heat treatment. Before ultrasonic testing, surface of weld and heat affected zone shall be checked out by visual inspection.

12.1.2检测面Inspection surface

⑴检测区域的宽度包括焊缝本身,再加上焊缝两侧各相当于母材厚度30%的一段区域,这个区域最小为5mm,最大为10mm。

⑴ The detection region include the width of weld and plus 30% of base material thickness on both sides of the weld, the minimum is 5mm, the maximum is 10mm.

⑵检测表面应平整光滑,焊接飞溅、铁屑、油垢、锈、马脚应清除干净,便于探头的自由扫查,其表面粗糙度Ra不应大于6.3μm,一般应进行打磨。

⑵ The detection of surface should be smooth, welding spatter, scrap iron, oil, rust, the weld feet should be cleaned, convenient for free scanning of probe, the surface roughness Ra should not larger than 6.3 μm, generally should be polished.

①采用一次反射法检测时,探头移动区应不小于1.25P,P=2TK;

式中:P―跨距,mm;

T―母材厚度,mm;

K―探头K值;

① Using a reflex testing, the probe movement area shall be not less than 1.25P, P=2TK; In type: P-span, mm;

T-base material thickness, mm;

K-K value of probe;

②采用直射法检测时,探头移动区应不小于0.75P。

② Using straight transmit testing, the probe movement area shall be not less than 0.75P.

⑶去除余高的焊缝,应将余高打磨到与母材平齐;保留余高的焊缝,如果焊缝表面有咬边,较大的隆起和凹陷等也应进行适当的修磨,并作圆滑过渡,以免影响检验结果的评定。

⑶ The removal of residual high weld, the residual high should burnished to equal to base material; The preserving residual high weld, if the weld surface having undercut, large apophysis and hollow should also be appropriate burnished, and made a smooth transition, so as not to affect the assessment results.

12.1.3根据工件的检验要求,选用仪器、探头和试块。

12.1.3 According to the work piece’s inspection requirements, selection of instrument, probe and test piece.

12.1.4仪器、探头的测试校验。

12.1.4 Test verifying of instrument and probe.

12.1.5距离-波幅曲线的制作。

12.1.5 Execution of distance amplitude curve.

12.2耦合剂Coupling matter

采用机油、浆糊、甘油、浆糊和水等透声性好,且不损伤检测表面的耦合剂。

Using the coupling matter with good sound penetration and harmless to the surface as oil, glycerin, paste, paste and water etc.

12.3探测频率和探头K值的选择

12.3 Selection of detection frequency and probe K value

12.3.1探测频率的选择按表4进行选择

12.3.1 Selection of detection frequency is according to table 4.

表4 探测频率的选择Table 4 Selection of detection frequency

探头K值的选择应能使主声束覆盖整个焊缝检测区, 条件允许时,应尽量采用较大K值探头。

The probe K value should be selected to make the main beam of sound to cover the whole weld inspection area, when conditions permit, should as far as possible using larger K probe.

条件允许时,T接头焊缝检测应分别使用直探头和斜探头扫查。

When conditions permit, straight and oblique probe should be used separately in T joint weld inspection.

⑴平板对接焊缝斜探头K值的选择按表5进行选择;

⑴ The selection of K value of oblique probe in plate butt weld inspection is shown in table

5.

⑵ T接头焊缝斜探头K值的选择按表6进行选择。

⑵The selection of K value of oblique probe in T joint weld inspection is shown in table 6.

12.4检测覆盖率Coverage rate of detection

检测时,探头的每次扫查覆盖率应大于探头直径的10%。

Each scanning coverage rate should be more than 10% of the diameter of probe in inspection.

12.5探头的移动速度Probe’s moving speed

探头的扫查速度不应超过150mm/s。当采用自动报警装置扫查时,不受此限。

The probe’s scanning speed should not exceed 150mm/s.When use automatic alarm device to scan, is not subject to this restriction.

12.6扫查灵敏度Scanning sensitivity

扫查灵敏度至少比基准灵敏度高6dB。

Scanning sensitivity is 6dB higher than the baseline sensitivity at least.

12.7母材的检验Base material inspection

斜探头扫查声束通过的母材区域,应先用直探头检测,以便检测是否有影响斜探头检测结果的分层或其它种类缺陷存在。母村检测的规程要点如下:

The base material area that oblique probe’s scanning acoustic beam pass through, should be inspected by straight probe, in order to detect whether there have stratification or other types of defects that influence the oblique probe test results. The standards gists of base

material inspection are shown as follows:

表5平板对接焊缝斜探头K值的选择

Table 5 The selection of K value of oblique probe in plate butt weld inspection.

表6 T接头焊缝斜探头K值的选择

12.7.1检测板厚不大于20mm的母材,采用5MHz的双晶直探头;检测板厚大于20mm的母材,采用2-5MHz的单晶直探头。探头晶片直径为10mm-20mm。

12.7.1 Dual-crystal straight probe of 5MHz is used to inspect base material that thickness is less than 20mm; single crystal straight probe of 2-5MHz is used to inspect base material that thickness is more than 20mm. The probe wafer diameter is 10mm-20mm.

12.7.2调节时基线,至少显示两次底波。

12.7.2 Adjust time baseline to show two bottom waves at least.

12.7.3双晶直探头调节检测灵敏度,将无缺陷的一次底波调到满屏刻度的50%,再提高10dB 作为检测灵敏度。

12.7.3 Adjust the primary bottom wave of no defects to 50% of full screen graduation, then improve 10dB as the detection sensitivity of dual-crystal straight probe.

12.7.4单晶直探头调节灵敏度,将无缺陷处的二次底波调到满屏刻度的100%。

12.7.4 Adjust the secondary bottom wave of no defects to 100% of full screen graduation as the detection sensitivity of single crystal straight probe.

12.7.5凡缺陷信号幅度超过荧光屏满刻度20%的部位或底波消失的区域,应在工件表面作出标记,并予以记录。

12.7.5 The area that amplitude of defect signal over 20% of full screen graduation or bottom wave disappearance, should be marked on the surface of the work piece, and recorded.

12.8检测方法Detection methods

12.8.1平板对接焊缝的检测Inspection of plate butt weld

⑴为检测纵向缺陷,原则上采用一种K值探头或两种K值探头在焊缝的单面双侧进行检测。母材厚度大于100mm,采用双面双例检测,如受几何条件限制,也可在焊缝双面单侧采用两种K值探头进行检测。斜探头应垂直于焊缝中心线放置在检测面上,作锯齿形扫查,见图5。探测前后移动的范围应保证扫查到全部焊缝截面。在保持探头垂直焊缝作前后移动的同时,还应作10°~15°的左右转动。

⑴ The detection of longitudinal defect, in principle using a K probe or two K probes to inspect on the single face-double side of weld. Base material thickness is larger than 100mm, using double faces-double sides detection, such as affected by geometric constraints, can also using two K probe to inspect on the double faces-single side of weld. Oblique probe should be perpendicular to the centerline of the weld placed on detection surface, as zigzag scan, see figure 5.Detection area of moving back and forth shall ensure to scan the whole weld section .In maintaining the probe vertical seam to move forth and back, at the same time should also turn around for 10°~15°.

图5 锯齿型扫查Fig 5 zigzag scan

⑵为检测焊缝及热影响区的横向缺陷应进行平行和斜平行扫查。检测时,可在焊缝两侧边缘使探头与焊缝中心成10~20°作斜平行扫查。见图6。焊缝母材超过100mm时,应在焊缝的两面作平行扫查或采用两种K值探头(K1和K1.5或K1和K2并用)作单面两个方向的平行扫查。

⑵The detection of the transverse defects in weld and heat affected zone should use parallel and inclined parallel scan. In detection, the probe made parallel scan in 10~20°to the weld center on both edge sides of weld seam. See figure 6.When base material thinness is more than 100mm, the probe made parallel scan on double faces, or using two K probe (K1 and K1.5 or K1 and K2 were used as single) to make parallel scan in two directions on single face.

图6 斜平行、平行扫查Figure 6 Parallel and inclined parallel scan

⑶为确定缺陷的位置、方向和形状,观察缺陷支柱波形和区分缺陷信号或伪缺陷信号,可采用前后、左右、转角、环绕等四种探头基本扫查方式,见图7

⑶ For determining the defect location, direction and shape, the observed defects pillar waveform and distinguished flaw signal or false defect signal, can use four kinds of basic scanning methods as forward and back, left and right, corner, around, see Figure 7

图7 四种基本扫查方法Figure 7 four basic scanning methods

12.8.2 曲面工件对接焊缝的检测Detection of bend surface butt weld

⑴检测面为曲面时,可尽是按平板对接焊缝的检测方法进行检测。对于受几何形状限制,无法检测的部位应予以记录。

⑴The detection of curved surface, can use the detection method of plate butt weld. The detection surface is in geometry constraint, position that can not be detected should be recorded.

⑵纵缝检测时,对比试块的曲率半径与检测面曲率半径之差小于10%。

⑵ In the longitudinal seam detection, the curvature radius difference between contrast test block and detection surface is less than 10%.

①根据工件的曲率和材料厚度选择探头K值,并考虑几何临界角的限制,确保声束能扫查

到整个焊缝。

①According to the curvature of the work piece and material thickness choice K value

probe, and considering the constraints of geometric critical angle, to ensure that sound beam can scan across the weld.

②探头接触面修磨后,应注意探头入射点和K值的变化,并用曲线试块作实际测定。

②The contact surface of probe after grinding, should take attention to the change of incidence point and K value, and actual mensurate in curve test block.

③当检测面曲率半径R大于W2/4且采用平面对比试块调节仪器时,应注意到荧光屏指示的缺陷深度或水平距离与缺陷实际的径向埋藏深度或水平距离弧长的差异,必要时进行修正。

③ When the detecting surface’s curvature radius R is greater than W2/4 and adjusting apparatus with plane contrast test block, should take attention to the difference between the depth or horizontal distance of screen indicating defects and the radial imbed depth or arc length of horizontal distance of actual defects, necessary correction.

⑶环缝检测时,对比试块的曲率半径应为检测面曲率半径的0.9~1.5倍。

⑶ In the ring seam detection, the curvature radius of contrast test block shall be 0.9~1.5 times than the curvature radius of detection surface.

12.8.3 管座角焊缝的检测Inspection of pipe seat fillet weld

⑴一般原则The general principle

在选择检测面和探头时应考虑到各种类型缺陷的可能性,并使声束尽可能垂直于该焊缝结构中的主要缺陷。

In the choice of testing surface and probe should consider the possibility of various types of defect, and make the sound beam possible perpendicular to the main defects in the weld structure.

⑵检测方式The detection methods

根据焊缝结构形式,管座焊缝的检测有如下五种探测方式,可选择其中一种或几种方式组合实施检测。检测方式的选择应由合同双方商定,并考虑主要检测对象和几何条件的限制。(图8、图9)。

According to the weld structure form, pipe socket weld detection has the following five kinds of detection methods, can choose one or several combined to detect. The mode selection of test should be agreed by the two parties, and consider the main inspected object and geometric constraints. (Figure 8, figure 9).

图8 插入式管座角焊缝Figure 8 Pipe socket weld

图9 安放式管座角焊缝Figure 9 Pipe bestowing weld

①在接管内壁采用直探头检测,见图8位置1。

① In the inner wall of joint pipe adopts the straight probe detection, see Figure 8 position

1.

②在容器内壁采用直探头检测,见图9位置1。

② In the inner wall of the container using straight probe detection, see Figure 9 position 1.

③在接管外壁采用斜探头检测,见图9位置2。

③ In the outer wall of joint pipe adopts oblique probe detection, see Figure 9 position 2.

④在按管内壁采用斜探头检测,见图8位置3和图9位置3。

④ In the inner wall of joint pipe adopts oblique probe detection, see position 3 in figure 8 and Figure 9.

⑤在容器外壁采用斜探头检测,见图8位置2。

⑤ In the outer wall of the container adopts oblique probe detection, see Figure 8 position

2.

⑶管座角焊缝以直探头检测为主,探头频率、尺寸及扫查方法应按12.7条的规定执行。对直探头扫查不到的区域,可采用斜探头检测。

⑶ The pipe seat fillet welds inspected by straight probe primarily, the probe frequency, size and scanning methods should be according to the regulation of 12.7 article. The region that straight probe can not scan, can inspected by oblique probe.

12.8.4T型焊缝的检测T weld detection

⑴腹板厚度不同时,选用的折射角见表6,斜探头在腹板一侧作直射法和一次反射法探伤见图10位置2。

⑴ When the web thickness is distinctness, the selection of refraction angle shown in Table

6. Oblique probe testing on web side with the inspection method of straight eradiation and principal reflection is shown in figure 10 position 2.

图10 T型接头Figure 10 T joint

图11 T型接头Figure 11 T joint

⑵采用折射角45°(K1)探头在腹板一侧作直射法和一次反射法探测焊缝及腹板侧热影响区的裂纹(图11)

⑵ Using the angle of 45° (K1) probe with inspection methods of straight eradiation and principal reflection on the web side to detect crack in weld and heat affected zone of web side (Figure 11).

⑶为探测腹板和翼板间未焊透或翼板侧焊缝下层撕裂状缺陷,可采用直探头(图10位置1)或斜探头(图11位置3)在翼板外侧探伤或采用折射角45°(K1)探头在翼板内侧作一次反射法探伤(图10位置3)。

⑶ In order to detect the incomplete penetration defects between web and wing plate or avulsion defects in underlayer weld of wing plate, can use straight probe (FIG. 10 position 1) or oblique probe(Figure 11 position 3) on the wing plate lateral to inspect, or use the refraction angle of 45°(K1) probe on the wing plate inside to inspect with principal reflection testing (Fig 10 position 3).

12.8.5 角接焊缝的检测Corner weld detection

角接接头探伤面及折射角一般按图12和表6选择。

The choice of inspection surface and refraction angle of probe in corner joint detection is according to Figure 12 and table 6.

图12 角接接头Fig 12 Corner joint

13 评定Assessing

13.1 缺陷定量检测Quantitative detection of defects

13.1.1 灵敏度应调到定量线灵敏度。

13.1.1 The sensitivity should be transferred to the quantitative line sensitivity.

13.1.2对所有反射波幅超过定量线的缺陷,均应确定其位置、最大反射波幅和缺陷当量;缺陷定量应根据缺陷最大反射波幅确定缺陷当量直径Ф或缺陷指示长度ΔL。

13.1.2 All the defects that echo amplitude over the quantitative line, should be determined location, maximum echo amplitude and equivalent defect; quantitative defect should be based on the maximum echo amplitude determined equivalent diameter Φ or indicated length ΔL of defects.

⑴缺陷当量直径Ф,用当量平底孔直径表示,主要用于直探头检测,可采用公式计算,距离一幅曲线和试块对比来确定缺陷当量尺寸。

⑴The equivalent diameter Φ of defect, denoted of equivalent hole diameter, is mainly used in straight probe detection, can calculate with formula, or determine by DAC curve contrast to test block.

⑵缺陷指示长度ΔL的测定、:

⑵ The indicated length ΔL meterage of defects:

①缺陷回波位于Ⅰ区:

① Defect echo is in region Ⅰ:

当只有一个峰幅时,以峰幅降到评定线的绝对灵敏度法测其指示长度。

When there have only one peak amplitude, measured the indicating length by the absolute sensitivity method that dropping peak amplitude to evaluating line.

当有多个峰幅时,以端点峰幅降到评定线的绝对灵敏度法测其指示长度。

When there have many peak amplitudes, measured the indicating length by the absolute sensitivity method that dropping extremity peak amplitude to evaluating line.

②缺陷回波高于Ⅱ区:

② Defect echo is in region Ⅱ:

当只有一个峰幅时,以峰幅降低6dB的相对灵敏度法测其指示长度。

When there have only one peak amplitude, measured the indicating length by the relative sensitivity method that dropping low 6dB of peak amplitude.

当有多个峰幅时,以端点峰幅低6dB的相对灵敏度法测其指示长度。

When there have many peak amplitudes, measured the indicating length by the relative sensitivity method that dropping low 6dB of extremity peak amplitude.

13.2缺陷评定Defect evaluation

13.2.1超过评定线的信号应注意其是否具有裂纹等危害性缺陷特征,如有怀疑时,应采取改变探头K值、增加检测面、观察静、动态波型并结合结构形式和焊接工艺等要素作判断,如对波型不能判断时,应辅以其它检测方法作综合判定。

13.2.1 Defect signal over the evaluating line signal should be paid attention to whether it has character of harmfulness flaw like crack. In case of doubt, should change K value probe, increase detection surface, observe static and dynamic wave from and combined with structure and welding technics to judge. If the wave shape can not be judged, should be supplemented by other detection methods for comprehensive judgement.

13.2.2缺陷指示长度小于8mm时按4mm计。

13.2.2 When the indicated length of defect less than 8mm counted with 4mm.

13.2.3相临两缺陷在一直线上,其间距小于其中较小的缺陷长度时,应作为一条缺陷处理,以两缺陷长度之和作为其指示长度(间距不计入缺陷长度)。

13.2.3 When two near defects on a straight line, the span less than the smaller defect length, should be as one defect, the sum of two defect lengths as the instruction length (the span without defect length).

13.3 缺陷等级评定Defects classification

13.3.1不允许存在下列缺陷:

13.3.1 The following defects are not allowed:

⑴反射波幅位于判废线及Ⅲ区的缺陷;

⑴ Defects that its reflex amplitude in the sentence line and III area.

⑵检测人员判定为裂纹等危害性的缺陷;

⑵ Defects that judged to harmfulness flaw like crack by detection personnel.

13.3.2最大反射波幅位于Ⅰ区的非裂纹类缺陷,均评为Ⅰ级。

13.3.2 Non crack defect that its maximum reflection amplitude is in regionⅠ, rated as gradeⅠ.

13.3.3最大反射波幅位于Ⅱ区的缺陷,应根据其指示长度按表7的规定予以评级。

13.3.3 The defect that its maximum reflection amplitude is in region Ⅱ, should be rated according to the instruction length based on rules in Table 7.

表7Ⅱ区缺陷的等级评定Table 7 Evaluation of defect in the region Ⅱ

注:⑴板厚不等的焊缝,以薄板为准。

Note:⑴ When the thickness of base materials are difference, take the thinness.

⑵最小—指T小于某一厚度时的允许值;如Ⅰ级焊缝,当T≤24mm时,允许单个缺陷指示长度为8mm。

⑵ Minimum - Allowed values that T is less than a certain thickness; such as for grade I weld, when T≤24mm, allows a single defect indication length is 8mm.

⑶最大--指T大于某一厚度时的允许值;如Ⅰ级焊缝,当T≥24mm时,允许单个缺陷指示长度不得大于24mm。

⑶ Maximum - Allowed values that T is more than a certain thickness; such as for grade I weld, when T≥24mm, allows a single indicated defect length should not more than 24mm.

⑷当焊缝长度不足6T或150mm时(二者取较小)时,可按比例折算,折算后允许的累计长度小于单个缺陷的允许长度时,以单个缺陷的允许长度作为限值。

⑷ When weld length less than 6T or 150mm (take the smaller), can converted according to proportion, when the converted permit cumulative length less than the permit length of single defect, take the permit length of single defect limit value.

⑸两个缺陷在任意6T或150mm时(二者取较小)焊缝长度内都能取到一部分,则应将这两个缺陷全部指示长度计入总长评定。

⑸ When two defects in any 6T or 150mm (take the smaller) of weld length can be taken parts, all the instruction length of two defects should be included in the total length for evaluation.

13.3.4不合格的缺陷应予以返修。返修部位及热影响区仍按原检测工艺进行检测。

13.3.4 Unqualified defect should be repaired. Repair position and heat affected zone still be tested according to the original detection technology.

13.3.5抽检部位的一端或者两端出现超标缺陷时,应在其延伸方向追加检测,并不应少于原抽检量,若追加的检测部位仍发现超标缺陷,则应对整条焊缝进行检测。

13.3.5 When unqualified defect appear in sampling site at one end or two ends, should be additional tested in the extending direction, and should not less than the original sample amount, if additional testing site is still found unqualified defect, the entire weld should be checked.

14 记录 Records

14.1《超声检测申请单》

14.1 "ultrasonic testing application form"

14.2《超声波检测记录》

14.2 " ultrasonic testing record"

15 报告Report

15.1《超声波检测报告》

15.1 "ultrasonic testing report"

附录Appendix

无损检测工艺规程的编制

无损检测工艺规程的编制 2012年3月 第一节一般知识 一、概念 无损检测工艺规程由通用工艺规程和工艺卡两部分组成。 1、通用工艺规程 通用工艺规程又称检验规程、工艺程序,是指本单位对结构件、承压设备和其他产品,在制造、安装、在役检验等方面对产品质量检测时,需要进行无损检测的通用的技术规定或规则,是原则性的指导文件,同时应符合有关标准、规程、法规的要求,并满足顾客的要求;针对某一类产品的特点进行编制,提出共有的规定,以便于统一实施;以文字说明为主,图表为辅,具有一定的覆盖性和通用性。 2、工艺卡 工艺卡是根据通用工艺的规定和要求及有关标准和合同委托要求,针对某一具体产品、工件编制的专用工艺卡,要求检测工艺参数具体,检测方法和程序明确,以图表为主,适当辅以文字说明,在专用工艺卡的各项参数均要有具体数值,操作者可以直接运用这些数据操作。 二、编制依据和原则 1、依据 (1)依据现行执行的标准和法规。如: ?《xx入级规范》、《xx建造规则》、《固容规》等等; ?CB/T3558、CB/T3559、GB/T3323、JB/T4730等等; ?国家颁布的相关文件。 (2)依据顾客的要求,即依据本单位顾客的具体情况,进行调查分析,对大多数顾客的要求进行明确的解答,提出处理意见。 (3)依据本单位技术水平,仪器装备情况,编制的工艺规程应做得到,切实可行。 2、原则 (1)遵照国家现行执行的标准和法规的要求,在检测工艺上可以比国家或行业现行执行的标准、法规更细,更具体,要求更高。在质量验收时应同时满足顾客要求和国家或行业现行执行的标准、法规。 (2)应根据本单位无损检测人员技术水平,检测能力应针对本单位或委托方产品特点,作到简明扼要,提出切实可行的工艺措施。如现场检测,只编入需要的内容。 (3)工艺规程中每一个步骤都要写清楚做什么、由谁去做、采用什么设备和辅助器材、什么时机做、按什么标准做等,并明确对工作人员和责任人员的资质要求。 (4)标准中需要确认的项目,应经确认后方可编入通用工艺如: ?UT耦合补偿的规定; ?检验的时机; ?自行制作的工作试块。 ?检测过程中采用的检测方法、检测工艺参数等内容应经试验和评审合格后方可使用。 (5)通用工艺中应采用本单位的一些行之有效和做法,如采用探头、专用工艺,但必须进行评审。 (6)通用工艺要求文字简练明确,对经常使用的参数和有关计算应预先计算好,列成图表。

射线照相工艺规程

射线照相工艺规程 本规程适用于是我公司在制造压力容器和压力管道安装过程中必须遵循的射线探伤通用工艺. 本守则依据标准: GB150-1998钢制压力容器、 GB151-1999 钢制换热器 TSG R0004-2009固定式压力容器安全技术规程 TSG D0001-2009 压力管道安全技术检测规程-工业管道 GB50235-1997 工业金属管道工程施工及验收规范 GB50148-1993 工业金属管道工程质量检验 JB/T 4730-005 承压设备无损检测 第一章(适用于压力容器) 1、对射线照相各项技术要求,针对压力容器的结构特点,提供保证射线 探伤工作质量所需遵循的通用工艺方法,本工艺射线探伤法符合 JBT4730.2-2005标准所规定的AB级照相法. 2、射线照相人员应经国家质量监督检验检疫总局培训、考核所颁发的特 种设备检验检测人员证后,RTⅠ或RTⅠ级以上资格人员担任. 3、射线照相须在全过程中严格按照射线照相工艺卡的各项参数进行操 作.“射线照相工艺卡”应由RTⅡ及其以上资格人员逐项填写编制,并经 无损检测责任人批准后使用. 4、射线胶片的使用与暗室处理按“管理制度汇编”暗室工作及制度执行.

5、摄片时机对一般材料,应在焊后12小时进行,对有延迟裂纹倾向的材料 应在焊后24小时进行. 6、委托探伤的压力容器焊缝必须有委托单位履行的无损探伤申请委托 单,申请单上必须有焊缝外观检验合格的见证和焊接检验员的签名. 7、射线照相前应对焊缝外观进行复验,焊缝表面的不规则状态在底片上 的图象应不掩盖焊缝中的缺陷与之混淆,否则应做适当的修整. 8、射线照相过程中的电离辐射防护应符合GB16357-1996《工业X射线 探伤放射性防护标准》GB18871-2002《电离辐射及辐射源安全基本标准》的有关规定. 9、射线照相的工艺要素和基本步骤: (1)透照方法的确定 (2)探伤编号方法 (3)几何条件的确定 (4)定位标记、识别标记、象质计的选用及摆放; (5)贴片及屏蔽散射线的措施 (6)射线窗口对焦 (7)曝光量的选择及操作 (8)底片质量自检

《有色金属标准》金属无损检测与探伤标准汇编

金属无损检测与探伤标准汇编 中国机械工业标准汇编金属无损检测与探伤卷(上)(第二版) 一、通用与综合 GB/T 5616-1985 常规无损探伤应用导则 GB/T 6417-1986 金属溶化焊焊缝缺陷分类及说明 GB/T 9445-1999 无损检测人员资格鉴定与认证 GB/T 12469-1990 焊接质量保证钢熔化焊接头的要求和缺陷分类GB/T 14693-1993 焊缝无损检测符号 JB 4730-1994 压力容器无损检测 JB/T 5000.14-1998 重型机械通用技术条件铸钢件无损探伤 JB/T 5000.15-1998 重型机械通用技术条件锻钢件无损探伤 JB/T 7406.2-1994 试验机术语无损检测仪器 JB/T 9095-1999 离心机、分离机锻焊件常规无损探伤技术规范二、表面方法 GB/T 5097-1985 黑光源的间接评定方法 GB/T 9443-1988 铸钢件渗透探伤及缺陷显示迹痕的评级方法 GB/T 9444-1988 铸钢件磁粉探伤及质量评级方法 GB/T 10121-1988 钢材塔形发纹磁粉检验方法 GB/T 12604.3-1990 无损检测术语渗透检测 GB/T 12604.5-1990 无损检测术语磁粉检测 GB/T 15147-1994 核燃料组件零部件的渗透检验方法 GB/T 15822-1995 磁粉探伤方法 GB/T 16673-1996 无损检测用黑光源(UV-A)辐射的测量 GB/T 17455-1998 无损检测表面检查的金相复制件技术 GB/T 18851-2002 无损检测渗透检验标准试块 JB/T 5391-1991 铁路机车车辆滚动轴承零件磁粉探伤规程 JB/T 5442-1991 压缩机重要零件的磁粉探伤 JB/T 6061-1992 焊缝磁粉检验方法和缺陷磁痕的分级 JB/T 6062-1992 焊缝渗透检验方法和缺陷迹痕的分级 JB/T 6063-1992 磁粉探伤用磁粉技术条件 JB/T 6064-1992 渗透探伤用镀铬试块技术条件 JB/T 6065-1992 磁粉探伤用标准试片 JB/T 6066-1992 磁粉探伤用标准试块 JB/T 6439-1992 阀门受压铸钢件磁粉探伤检验 JB/T 6719-1993 内燃机进、排气门磁粉探伤 JB/T 6722-1993 内燃机连杆磁粉探伤 JB/T 6729-1993 内燃机曲轴、凸轮轴磁粉探伤 JB/T 6870-1993 旋转磁场探伤仪技术条件 JB/T 6902-1993 阀门铸钢件液体渗透探伤

无损检测工艺规程

射线检测工艺规程通常包含以下内容: 1.适用范围(依据的法规标准、透照质量等级、透照母材厚度范围、工件种类、焊接方法和类型等) 2.对检测人员的要求(资格、视力等) 3.检测准备要求(检测时机、工件表面状况、钢印标方法等) 4.设备、器材要求(射线源和能量的选择、胶片牌号和类型、增感屏、像质计、暗盒、铅字等) 5.透照方法及相关要求(100%透照或局部透照的要求,焦距选择,一次透照长度,编号方法,像质计和标记的摆放,散射线的屏蔽等) 6.曝光参数及曝光曲线(管电压、管电流、曝光时间等) 7.暗室处理(洗片方法、胶片处理程序、条件及要求等) 8.底片评定(评片条件、验收标准、像质鉴定、级别评定、返修规定) 9.记录报告(记录报告的内容及要求、资料、档案管理要求等) 10.安全防护要求 11.其他必要的说明 超声检测工艺规程通常包含以下内容: 1.适用范围(指明该通用工艺规程适用于哪类工件或哪种产品的焊缝及焊缝类型等 2.引用标准、法规(技术文件引用的法规、安全技术规范和技术标准等) 3.检测人员资格(对检测人员的资格要求) 4.检测设备、器材和材料(超声检测用得仪器、探头、试块和耦合剂等。主要性能指标有:检测设备规格型号、探头类型、晶片尺寸和频率;标准试块及对比试块型号名称;耦合剂型号名称) 5.检测表面制备(对被检工件表面的准备方法及要求等) 6.检测时机(指不同材料的被检工件超声检测的时间安排等) 7.检测工艺和检测技术(指明进行超声检测时可选择的检测技术等级、检测方法、检测方向、扫查方式、检测部位范围、仪器时基线比例和灵敏度调整、测定缺陷范围、当量和指示长度的方法等) 8.检测结果的评定和质量等级分类(指明检测结果评定所依据的验收标准或技术标准以及验收合格级别等) 9.检测记录、报告和资料存档(规定检测原始记录、报告内容及格式要求、资料、档案管理要求、安全管理规定等) 10.编制(级别)、审核(级别)和批准人、制定日期(超声检测通用工艺规程的编制、审核及批准应符合相关法规或标准的规定) 磁粉检测工艺规程通常包含以下内容: 1.总则:适用范围、所用标准的名称代号和对检验人员的要求 2.被检工件:工件材质、形状、尺寸、表面状况、热处理状态和关键部位的检测 3.设备和器材:设备的名称和规格,磁粉和磁悬液的种类 4.工序的安排和检测比例 5.检测方法:采用湿法、干法、连续法还是剩磁法 6.磁化方法:通电法、线圈法、中心导体法、触头法、磁轭法或交叉磁轭法 7.磁化规范:磁化电流、磁场强度或提升力 8.灵敏度控制:试片类型和规格 9.磁粉探伤操作:从预处理到后处理,每一步的主要要求 10.磁痕评定及质量验收标准 渗透检测工艺规程通常包含以下内容: 1.适用范围:指明规程适用于哪类构件或部件 2.编制依据:委托书、技术文件盒引用规范、标准等 3.人员要求 4.被检构件或部件状态:包括被检件名称、形状、尺寸、材质表面粗糙度、热处理状态及表面处理状态。还应指明渗透检测的工序安排 5.渗透检测用得设备仪器及材料:渗透液、乳化剂、去除剂及显影剂的种类和型号 6.渗透检测工艺参数:渗透检测前被检工件表面的准备方法及要求,渗透液、乳化剂及显影剂的施加方法,

无损检测通常工艺标准规范标准规章

无损检测通用工艺规程 编制: ________________ 审核:________________ 批准:________________ 日期:________________

目录 第1章编制说明............................................... (3) 第2章射线检测通用工艺规程................................ (5) 第3章超声波检测通用工艺规程.................................... .21第1节承压设备对接焊接接头超声检测及质量分级.................... .24第2节承压设备钢板超声检测及质量分级............................ .29第3节承压设备用钢锻件超声检测及质量分级....................... .32第4章磁粉检测通用工艺规程.................................... .35第5章渗透检测通用工艺规程. (39) 第6章工艺卡附表............................................... .44第1节射线检测工艺卡.......................................... .44第2节超声检测工艺卡.. (45) 第3节磁粉检测工艺卡 (46)

第4节渗透检测工艺卡 (47)

第一章编制说明 1.1范围 本规程规定了对金属原材料、零部件和焊接接头进行射线检测、超声检测、磁粉检测、渗透检测的基本要求。 本规程适用于本公司钢制压力容器产品的无损检测工作。 1.2引用标准和编制依据 下列标准包含的条文,通过在本规程中引用而构成本规程的条文,在规程出版时,所有版本均为有效。所有标准都会被修订,使用本规程的各方应探讨使用下列标准最新版本的可能性。 压力容器安全技术监察规程(1999年版) GB150-1998 《钢制压力容器》 GB151-1999 《管壳式换热器》 JB/T4730.1?4730.6-2005 《承压设备无损检测》 《特种设备无损检测人员资格考核实施细则》 《放射卫生防护基本标准》 Q/JS.YLRQ--2008《质量保证手册》 1.3人员资格及职责 1.3.1从事无损检测的人员必须持有国家质量监察机构颁发的并与其工作相适应的资格等级证书。1.3.2从事无损检测的人员校正视力不得低于5.0,从事磁粉、渗透检测工作人员,不得有色盲、色弱。 1.3.3检测人员严格执行有关条例、规程、标准和技术规范,保证工作质量。 1.3.4评片人员的视力应每年检查一次,要求距离400mn能读出0.5mm的一组印刷体字母。 1.3.5检测操作人员必须按委托单要求并同时根据检测工艺规程进行操作,做好检测记录及签发检测报告。 1.3.3无损检测责任工程师的职责见《岗位职责》。 1.4无损检测方法使用原则

无损探伤检测工艺规程

无损探伤检测工艺规程 无损探伤检测工艺规程

一、检测范围 超声检测采用A 型脉冲反射式超声探伤仪,检测范围包括原 材料,铸件,锻造件,焊缝的缺陷检测。 二、引用标准、法规: JB/T10559-2006 《起重机械无损检测钢焊缝超声检测》三、检测人员 检测人员必须持证上岗,并严格执行审核制度。

四、探伤仪 TS-2008C 数字式超声波探伤仪,工作频率为1~5MHz,至少在荧光屏满刻度的80%范围内呈线性显示;80dB 以上连续可调衰减器,步进级每档≤2dB,精度为任意相邻12dB 误差在±1dB 内,最大累计误差不超过1dB;水平线性误差≤1%,垂直线性误差≤5%。 五、探头 常用探头有单直探头、单斜探头、双晶探头等,在达到所检工件的最大检测声程时,其有效灵敏度余量≥10dB。 六、超声检测一般方法 1、检测复盖率 检测时应尽量扫查到工件的整个被检区域,探头的每次扫查复盖率应>探头直径的15%。 、探头的移动速度2. 探头的扫查速度不超过150mm/s。 3、扫查灵敏度 扫查灵敏度至少比基准灵敏度高6dB。 4、耦合剂

采用机油、甘油等不损伤工作表面的耦合剂。 5、检测面 检测面应经外观检查合格,所有影响超声检测的锈蚀、飞溅和污物均应清除,其表面粗糙度符合检测要求。 6、耦合补偿 6.1 表面粗糙度补偿

在检测和缺陷定量时,对由表面粗糙度引起的能量损耗进行补偿。 6.2 衰减补偿 在检测和缺陷定量时,对材质衰减引起的检测灵敏度下降和缺陷定量误差进行补偿。 6.3 曲面补偿 在对曲面工件检测时,考虑曲面因素对结果误差的影响进行补偿。 7、校准 校准在基准试块上进行,使超声波主声束垂直对准反射体的轴线,以获得稳定和最大的反射信号。 7.1 仪器校准 在仪器开始使用时,对仪器的水平线性进行测定;在使用过. 程中,每隔三个月至少对仪器的水平和垂直线性进行一次测定。 7.2 探头校准 在探头开始使用时,对探头进行一次全面的性能校准。 7.2.1 斜探头校准

tofd检测通用工艺规程参考版

衍射时差法超声检测通用工艺规程 文件编号:2013 编制:___________________ 审核: 批准:__________________ 上海鹰扬智能科技工程有限公司

1编制的目的和适用范围 (1) 2引用标准、规范 (1) 3术语定义 (2) 4检测人员要求 (2) 5检测设备、器材和材料 (3) 6检测表面要求 (6) 7检测时机 (6) 8T0FD检测技术工艺 (6) 8.1 TOFD检测基本程序 (6) 8.2检测前准备 (7) 8.3表面盲区确定 (8) 8.4横向缺陷 (8) 8.5探头-12dB声场测试 (8) 8.6与其他无损检测方法的综合应用 (9) 8.7现场条件要求 (10) 8.8检测准备 (10) 8.9检测系统设置和校准 (15) 8.10 检测 (17) 8.11数据文件的命名规则 (18)

8.12焊缝检测记录 (18) 9检测数据分析和解释 (19) 9.1检测数据的有效性评价 (19) 9.2相关显示和非相关显示 (19) 9.3缺陷位置的测定 (20) 9.4缺陷尺寸测定 (22) 9.5检测结果的评定和质量等级分类 (22) 10编制专用检测工艺卡 (26) 11检测流程 (21) 12检测记录、报告和资料存档 (21) 附件1衍射时差法超声检测工艺卡 (29) 附件2衍射时差法超声检测报告 (32) 附件3T0FD检测返修通知单 (37) 附件4衍射时差法超声检测记录 (39)

1编制的目的和适用范围 为了保证本公司检测工作质量,提供准确可靠的检测数据,特制定本通用规程,本规程对衍射时差法超声检测(TOFD)中各环节质量控制要求作出了规定。本通用规程适用于以下焊接接头的TOFD检测。 1.1材料为碳素钢或低合金钢; 1.2全焊透结构型式的对接接头; 1.3工件厚度t: 12mm< t < 100mm不包括焊缝余高,焊缝两侧母材厚度不同时,取薄侧厚度值)。 1.4与承压设备有关的支撑件和结构件的衍射时差法超声检测,可参照本规程使用;对 于其他细晶各向同性和低声衰减材料,也可参照本规程使用,但要考虑声速衰减。 1.5对于非特种设备的TOFD检测,参照本作业指导书执行。 2引用标准、规范、文件 2.1《承压设备无损检测》JB/T 4730.1?5 -2005 2.2《承压设备无损检测》第10部分:衍射时差法超声检测NB/T4701 3.10 2.3《固定式压力容器安全技术监察规程》TSGR0004-2010 2.4《钢制球形储罐》GB12337-2010 2.5无损检测术语超声检测(£05577:2000) GB/T12604.1 2.6上海鹰扬智能科技工程有限公司质量管理体系文件

无损检测通用工艺规范培训文件

无损检测通用工艺规程 编制: 审核: 批准: 日期:

目录 第1章编制讲明 (3) 第2章射线检测通用工艺规程 (5) 第3章超声波检测通用工艺规程 (21) 第1节承压设备对接焊接接头超声检测及质量分级 (24) 第2节承压设备钢板超声检测及质量分级 (29) 第3节承压设备用钢锻件超声检测及质量分

级 (32) 第4章磁粉检测通用工艺规程 (35) 第5章渗透检测通用工艺规程 (39) 第6章工艺卡附表 (44) 第1节射线检测工艺卡 (44) 第2节超声检测工艺卡 (45) 第3节磁粉检测工艺卡 (46) 第4节渗透检测工艺卡 (47)

第一章编制讲明 1.1 范围 本规程规定了对金属原材料、零部件和焊接接头进行射线检测、超声检测、磁粉检测、渗透检测的差不多要求。 本规程适用于本公司钢制压力容器产品的无损检测工作。 1.2 引用标准和编制依据 下列标准包含的条文,通过在本规程中引用而构成本规程的条文,在规程出版时,所有版本均为有效。所有标准都会被修订,使用本规程的各方应探讨使用下列标准最新版本的可能性。 压力容器安全技术监察规程(1999年版) GB150-1998 《钢制压力容器》 GB151-1999 《管壳式换热器》 JB/T4730.1~4730.6-2005 《承压设备无损检测》 《特种设备无损检测人员资格考核实施细则》 《放射卫生防护差不多标准》 Q/JS.YLRQ--2008《质量保证手册》 1.3 人员资格及职责

1.3.1从事无损检测的人员必须持有国家质量监察机构颁发的并与其工作相适应的资格等级证书。 1.3.2从事无损检测的人员校正视力不得低于5.0,从事磁粉、渗透检测工作人员,不得有色盲、色弱。 1.3.3检测人员严格执行有关条例、规程、标准和技术规范,保证工作质量。 1.3.4评片人员的视力应每年检查一次,要求距离400mm能读出0.5mm的一组印刷体字母。 1.3.5检测操作人员必须按托付单要求并同时依照检测工艺规程进行操作,做好检测记录及签发检测报告。 1.3.3 无损检测责任工程师的职责见《岗位职责》。 1.4 无损检测方法使用原则 1.4.1 射线和超声检测要紧用于承压设备的内部缺陷的检测;磁粉检测要紧用于铁磁性材料制承压设备的表面和近表面缺陷的检测;渗透检测要紧用于非多孔性金属材料和非金属材料制承压设备的表面开口缺陷的检测。 1.4.2 铁磁性材料表面检测时,宜采纳磁粉检测。 1.4.3 当采纳两种或两种以上的检测方法对承压设备的同一部位进行检测时,应按各自的方法评定级不。 1.4.4 采纳同种检测方法按不同检测工艺检测时,假如检测结果不一致,应以危险度大的评定级不为准。

无损检测通常工艺处理制度

无损检测通用工艺规程 编制: 审核: 批准: 日期:

目录 第1章编制说明....................................... .?.?.3 ?… 第2章射线检测通用工艺规程........................... ::…壬 第3章超声波检测通用工艺规程.............................. :21… 第1节承压设备对接焊接接头超声检测及质量分级................. .24 第2节承压设备钢板超声检测及质量分级....................... .29 第3节承压设备用钢锻件超声检测及质量分级................... .32 第4章磁粉检测通用工艺规程................................ .35… 第5章渗透检测通用工艺规程............................... 39 - 第6章工艺卡附表.................................. .44… 第1节射线检测工艺卡..................................... :44… 第2节超声检测工艺卡.................................. 45… 第3节磁粉检测工艺卡.................................. 46… 第4节渗透检测工艺卡..................................... 47--- 第一章编制说明 1.1范围 本规程规定了对金属原材料、零部件和焊接接头进行射线检测、超声检测、磁粉检测、渗透检测的基本要求。 本规程适用于本公司锅炉压力容器产品的无损检测工作。

无损检测工艺流程

无损检测工艺流程 无损检测工艺流程 1根据施工图纸设计要求、相关规范(标准)确定无损检测内容后,施工单位应办理检测委托,填写《检测委托书》,并依据委托书的要求,实施委托检测,并确定检测部位,作好受检产品、材料、配件等受检部位的识别标记。 2在检测过程中如有与检测相关的变更,施工单位应及时以书面形式通知相关检测组,检测组根据变更对检测计划进行相应的调整。 3检测准备和实施 3.1检测人员按照每一类检测对象,依据委托书、检测标准、作业指导书等技术资料,编制工艺卡,确定检测技术参数,。 3.2检测组成员应做好设备、仪器、材料、工具及防护用品的准备,并负责就检测条件(如检测时间、水源、电源、通风、照明、脚手架、安全围护等)与施工单位及时联系,确保检测工作顺利进行。 3.3检测人员应严格按照标准规范、作业指导书进行操作,及时作好检测原始记录。 3.4在进行射线检测前,要求施工单位做好检测区域内的安全标识和围护,并在施工单位工程部办理入场手续和射线作业许可证(票),检测人员应将此证(票)随身携带,以备检查。 4检测结果 4.1检测人员第二天必须根据标准规范对检测结果进行评定,及时填发检测报告,作好各种原始记录。 4.2检测责任师对检测数据及评定结果进行校核,对检测结果的真实性和准确性负责,结果有误时,应及时更正,必要时重新检测。 4.3因检测工作量大等原因不能及时填写检测报告时,可先填写《检测结果通知书》,不合格需返修部位以《返修通知书》的形式通知施工单位。 4.4如有不合格部位的工件应按有关验收规范、标准或技术要求进行扩探,并以《扩探通知书》的形式通知施工单位。 5底片质量; 5.1所有底片上,定位和识别标记影像应显示完整、位置正确。 5.2底片评定范围内的黑度D应符合AB级要求:2.0-4.0之间。 5.3底片本底灰雾度D0<0.3。 5.4底片的像质计灵敏度应符合JB/T4730-2005《承压设备无损检测标准》要求。 5.5底片评定范围内不应存在干扰缺陷影像识别的水迹、划伤、斑纹等伪缺陷影像。 5.6资料的归档:所有检测工程结束后,检测报告和底片图纸及各种原始记录应整理交公司存档,若用户需要,也可交用户保管,底片保存期为7年。 5.7随时接受并积极配合业主、监理、施工单位、质量监督部门进行的监督检查,并提供所需的检测资料和相关材料。 射线检测通用工艺规程 射线检测通用工艺规程 1.主题内容与适用范围

NB47013无损检测通用工艺规程

无损检测通用工艺规程目录 第一篇总则 第二篇射线检测通用工艺规程 第三篇超声波检测通用工艺规程 第四篇磁粉检测通用工艺规程 第五篇渗透检测通用工艺规程

无损检测通用工艺总则 1.1 主题内容与适用范围 本工艺规程规定了射线检测(RT)、超声波检测(UT)、磁粉检测(MT)、渗透探伤(PT)四种无损检测的工艺方法。 本工艺规程适用于本公司特种设备制造、安装、改造、维修原材料、零部件和焊缝的无损检测。 1.2 引用标准 1)《固定式压力容器安全技术监察规程》 2)《特种设备无损检测人员考核规则》 3)《压力管道安全技术监察规程-工业管道》 4)NB/T47013-2015《承压设备无损检测》 1.3一般要求 1.3.1 选择原则 1.3.1.1 特种设备RT、UT、MT、PT的选择及抽检率应按《容规》、《压力管道安全技术监察规程-工业管道》、GB150、GB151及图样的要求执行。 1.3.1.2 有裂纹倾向的材料应在焊后24小时后,才能进行焊缝无损检测。 1.3.1.3 对要求无损检测的角接接头、T型接头,不能进行RT或UT检测时,应进行表面无损检测。 1.3.1.4 凡铁磁性材料制成的特种设备及零部件,优先使用MT检测表面缺陷 确因结构形状等原因不能使用MT检测时,方可采用PT检测。 1.3.2 检测人员 1.3. 2.1 从事特种设备无损检测人员必须应按照《特种设备无损检测人员考核规则》的要求取得相应的无损检测资格。 1.3. 2.2 取得不同无损检测方法的各技术等级人员,只能从事与该等级相应的无损检测工作,并负相应的技术责任。 1.3. 2.3 各种检测方法的报告,均由II级以上资格人员签发,并加盖公章。 1.3. 2.4 从事射线检测人员上岗前应进行辐射安全知识的培训,并取得放射工作人员证。 1.3. 2.5 从事磁粉、渗透检测工作人员,不得有色盲。 1.3. 2.6 射线检测人员未经矫正或经矫正的近(距)视力和远(距)视力应不低于5.0(小数记录值为1.0),测试方法应符合GB11533的规定。从事射线评片人员每年检查一次视力。

完整word版射线检测工艺规程

射线检测通用工艺规程 1. 主题内容与适用范围本规程规定了焊缝射线人员具备的资格、所用器材、检测工艺和验收标准等内容。 本规程依据JB/T4730-2005的要求编写。适用于本公司板厚在2?30 mm钢制压力容器及壁厚T>2mm钢管对接焊接接头的X射线AB级检测技术。满足《压力容器安全技术监察规程》GB150、GB151 的要求。检测工艺卡内容是本规程的补充, 由n级人员按本规程等要求编写,其参数规定的更具体。 2. 引用标准、法规 JB/T4730 —2005《承压设备无损检测》 GB150-1998《钢制压力容器》 GB151-1999《管壳式换热器》 GB18871—2002《电离辐射防护及辐射源安全基本标准》 GB16357-1996《工业X射线探伤放射卫生放护标准》 JB/T7902《线型象质计》 特种设备无损检测人员考核与监督管理规则》 压力容器安全技术监察规程》 3. 一般要求 3.1射线检测人员必须经过技术培训,按《特种设备无损检测人员考核与监督管 理规则》考核并取得与其工作相适应的资格证书。 3.1.1检测人员应每年检查一次视力,校正视力玄1.0。评片人员还应辨别出 400mn距离处 高0.5mm间距0.5mm的一组印刷字母。 3.2 辐射防护 射线防护应符合GB18871 GB16357的有关规定。

透照厚度(W 范围、mm 应识别丝号 丝径(mm 3.3胶片和增感屏 胶片:在满足灵敏度要求的情况下,一般 X 射线选用T3或T2型胶片。 增感屏:采用前屏为0.03mm 后屏为0.03?0.10mm 的铅箔增感屏。. 3.4象质计 3. 4.1底片影像质量采用Fe 线型像质计测定。其型号和规格应符合 JB/T7902 的规定。象质计型号一般按下表 4选定。但对透照外径W 100mn 钢管环缝 时采用 JB/T4730附录F 的专用象质计。 3.4.2底片的象质计灵敏度选用 按透照厚度及不同的透照方法选择表 1至表3中要求达到的象质丝号。 3.4.3透照厚度W 射线照射方向上材料的公称厚度。多层透照时,透照厚度为 通过 的各层材料公称厚度之和。焊缝两侧母材厚度不同时,以薄板计。 表1象质计灵敏度值-单壁透照、象质计置于源側 (AB 级) 表2象质计灵敏度值-双壁双影透照、象质计置于源側 (AB 级) 表3象质计灵敏度值-双壁单影或双壁双影透照、象质计置于胶片側 (AB 级) 3.3.1 3.3.2 3.3.3 胶片和增感屏在透照过程中应始终紧密接触。

无损检测工艺的评定

探伤工艺的评定 丁老师及各位前辈好: 我单位最近在接受API换证审核,审核人员提出了无损检测作为一个特殊过程,对特殊过程中的再确认中对无损检测工艺有没有做评定。以前从来没有接触到这个问题,所以想问问各位老师,对无损检测工艺是不是需要做评定,如果需要,这个评定又该如何做,应该包含哪些东西? 丁:当然需要进行工艺评定,不过在国内未得到重视而已! 具体的方法,与采用的检测方法、技术、评定的标准要求有关,一言难尽呀! 问:这是我自己做的一个评定表,还要附磁探设备的鉴定证书,提升力试块的鉴定证书以及磁粉的鉴定证书和提升力的校准记录。请丁老师看看有什么不妥的地方需要修改。 丁:作为评定,一定得有评定依据和检测对象的相关信息。 但,一般体系审核注重有无资料,不太重视资料的正确性。 问:您所说的评定依据该怎么理解?是采用的标准还是? 丁:是评定过程中引用的标准,包括方法标准、产品制造规范和可能的验收规范。 问:方法标准和制造规范可以实施,但是这个验收规范怎么去评定,麻烦您给讲一下! 丁:应达到的检出率和误报率及检测工艺的可靠性POD。 无损检测广义可靠性及其研究方法 文章链接:中国化工仪器网https://www.360docs.net/doc/df5807305.html,/Tech_news/Detail/338731.html :NDT狭义可靠性 传统理论描述的NDT可靠性,定性地说是指无损检测系统对缺陷的检验能力,从定量角度出发,它通常以缺陷探测概率POD来衡量。 显然,单纯运用POD来衡量的NDT可靠性,是值得商榷的。将缺陷检出来,是讨论检测结果可靠与否的前提条件,磁粉探伤仪其次,还应考虑被检出的缺陷尺寸与缺陷真实尺寸之间相对应的程度,即检测精确度。为此,笔者对常规NDT可靠性的定义进行了修正,提出了狭义可靠性的概念,它可以定量地表达为缺陷检出概率尸与缺陷检测精确度的平均值S 的乘积,它们通常都是缺陷尺寸的函数,即借助于NDT可靠性试验并对其结果进行统计分析后表明,用衡量的NDT狭义可靠性比POD更加能够反映NDT系统的某种不确定性,因此也更加接近实际情况。然而,式中所反映的NDT可靠性,是在特定的检测环境下检测人员运用某种特定的NDT系统对给定尺寸缺陷的检测结果,所体现的只是NDT系统的检测能力,显然它只能是一种狭义的可靠性。 从更广泛意义上说,NDT的可靠性除了检测系统本身的能力之外,更重要的还在于对这种能力的运用、把握和控制,是NDT综合质量的体现。因此,有必要进行更加深入的研究工作。 2:NDT广义可靠性 检测系统的能力只能反映NDT可靠性的一个方面。试想,即便某检测系统具备非常强的检

射线检测通用工艺规程

射线检测通用工艺规程 1目的 对射线检测作业的工艺作出规程性的规定,以保证射线检 测过程符合有关的法规、标准以及公司《质量保证手册》及 《程序文件与管理制度汇编》的要求。 2 范围 适用于金属材料制容器的原材料、零部件和焊缝射线检测的作业过程。 3 引用标准 JB/T4730.1 -2005 《承压设备无损检测》第1部分通用 要求 JB/T4730.2-2005 《承压设备无损检测》第2部分射线 检测 4人员资格 4.1凡射线检测人员应按《锅炉压力容器无损检测人员资格鉴定考核规则》考核合格,并持有与工作相适应的有效资格证书。 4.2评片人员应每年做一次视力检查,矫正视力不得低于 1.0,并要求距离40mm能读出高为0.5 mm、间距为0.5 mm的印刷字母。

4.3取得不同射线检测资格级别的人员,只能从事与资格级 别相应的无损检测工作。检测原始记录应由相应□级或口级 以上资格人员核对,射线检测检测报告须经相应H级或□级 以上资格人员复核并签字后方能生效。 4.4从事射线检测人员上岗前应经辐射安全知识培训,并取 得放射工作人员证。 5检测设备、器材和材料 5.1检测设备 按本公司《无损检测仪器使用、维护管理规定》执行。 5.2射线胶片 5.2.1 胶片系统按照GB/T19384.1 - 2003《无损检测工业射 线照相胶片第一部分工业射线胶片系统的分类》分为四类, 即T1、T2、T3、T4。T1为最高类别,T4为最低类别。 5.2.2射线检测技术为A级、AB级时,应采用T3及以上类别的胶片,射线检测技术为B级时,应采用T2及以上类别的胶片。 5.3观片灯 —95 —

无损检测工艺流程图文稿

无损检测工艺流程 集团文件版本号:(M928-T898-M248-WU2669-I2896-DQ586-M1988)

无损检测工艺流程 无损检测工艺流程 1根据施工图纸设计要求、相关规范(标准)确定无损检测内容后,施工单位应办理检测委托,填写《检测委托书》,并依据委托书的要求,实施委托检测,并确定检测部位,作好受检产品、材料、配件等受检部位的识别标记。 2在检测过程中如有与检测相关的变更,施工单位应及时以书面形式通知相关检测组,检测组根据变更对检测计划进行相应的调整。 3检测准备和实施 3.1检测人员按照每一类检测对象,依据委托书、检测标准、作业指导书等技术资料,编制工艺卡,确定检测技术参数,。 3.2检测组成员应做好设备、仪器、材料、工具及防护用品的准备,并负责就检测条件(如检测时间、水源、电源、通风、照明、脚手架、安全围护等)与施工单位及时联系,确保检测工作顺利进行。 3.3检测人员应严格按照标准规范、作业指导书进行操作,及时作好检测原始记录。 3.4在进行射线检测前,要求施工单位做好检测区域内的安全标识和围护,并在施工单位工程部办理入场手续和射线作业许可证(票),检测人员应将此证(票)随身携带,以备检查。 4检测结果

4.1检测人员第二天必须根据标准规范对检测结果进行评定,及时填发检测报告,作好各种原始记录。 4.2检测责任师对检测数据及评定结果进行校核,对检测结果的真实性和准确性负责,结果有误时,应及时更正,必要时重新检测。 4.3因检测工作量大等原因不能及时填写检测报告时,可先填写《检测结果通知书》,不合格需返修部位以《返修通知书》的形式通知施工单位。 4.4如有不合格部位的工件应按有关验收规范、标准或技术要求进行扩探,并以《扩探通知书》的形式通知施工单位。 5底片质量; 5.1所有底片上,定位和识别标记影像应显示完整、位置正确。 5.2底片评定范围内的黑度D应符合AB级要求:2.0-4.0之间。 5.3底片本底灰雾度D0<0.3。 5.4底片的像质计灵敏度应符合JB/T4730-2005《承压设备无损检测标准》要求。 5.5底片评定范围内不应存在干扰缺陷影像识别的水迹、划伤、斑纹等伪缺陷影像。 5.6资料的归档:所有检测工程结束后,检测报告和底片图纸及各种原始记录应整理交公司存档,若用户需要,也可交用户保管,底片保存期为7年。 5.7随时接受并积极配合业主、监理、施工单位、质量监督部门进行的监督检查,并提供所需的检测资料和相关材料。

特种设备射线检测通用工艺规程(按NBT47013修订)

XXX有限公司 特种设备射线检测通用工艺规程 1、范围 本规程规定了承压设备金属熔化焊对接接头的X射线检测技术和质量分级要求。 本规程适用于承压设备受压元件的制造检测中对接焊缝、管座角焊缝和管子管板角焊缝的射线检测。用于制作焊接接头的金属材料包括碳素钢、低合金钢、不锈钢。 本规程规定的射线检测技术分为三级:A级一一低灵敏度技术;AB级一- 中灵敏度技术;B级一一高灵敏度技术。 承压设备的有关支承件和结构件的对接焊接接头的射线检测,也可参照使用2、规范性引用文件 下列文件中的条款,通过在本规程中的引用而成为本规程的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版不适用于本规程。凡是不注日期的引用文件,其最新版本适用于本规程。 NB/T47013-2015 承压设备无损检测 GB11533-2011 标准对数视力表 GBZ117-2015 工业X射线探伤放射卫生防护标准 GB18871-2002 电离辐射防护与辐射源安全基本标准 GB11924-1989 辐射安全培训规定 GB/T12604.2-2005 无损检测术语射线检测 HB7684-2000 射线照相用线型象质计 JB/T7902-2006 线型象质计 JB/T7903-1999 工业射线照相底片观片灯 3、一般要求 射线照相检验的一般要求除应符合NB/T47013.1-2015的有关规定外,还应符 合下列规定。 3.1 射线检测人员

XXX有限公司 特种设备射线检测通用工艺规程 3.1.1从事射线检测人员上岗前应进行按GB11924的规定进行辐射安全知识的培训,并取得放射工作人员证。 3.1.2射线检测人员未经矫正或经矫正的近(距)视力和远(距)视力应不低于 5.0 (小数记录值为1.0),测试方法应符合GB11533的规定。从事评片的人员应每年检查一次视力。 3.2射线胶片 3.2.1射线胶片系统分为6类,即C1、C2、C3、C4、C5、C6类。C1为最高类别,C6为最低类别。胶片系统的特性指标和常见牌号胶片所属的胶片系统类别见附录A (资料性附录)。 3.2.2A级和AB级射线检测技术应采用C5类或更高类别的胶片,B级射线检测技术应采用C4类或更高类别的胶片。 3.3观片灯 3.3.1观片灯的主要性能应符合GB/T19802的有关规定。 3.3.2观片灯的最大亮度应能满足评片的要求。 3.4黑度计(光学密度计) 3.4.1黑度计可测的最大黑度应不小于4.5,测量值的误差应不超过土0.05。 3.4.2黑度计首次使用前应进行核查,以后至少每六个月应进行一次核查,形成核查报告。在工作开始时或连续工作超过8h后应在拟测量黑度范围内选择至少两点进行检查。 3.5增感屏 射线检测一般应使用金属增感屏或不用增感屏,金属增感屏应满足JB/T5075 的要求,增感屏应完全干净、抛光和无纹道。增感屏的选用应符合表1的规定。 3.6象质计 3.6.1底片影像质量采用线型像质计或孔型像质计测定。通用线型像质计和等径线型像质计的型号和规格应符合JB/T 7902的规定,孔型像质计型号和规格应满 足GB/T 23901.2的规定 3.6.2象质计的材料、代号和不同材料的象质计适用的工件材料范围应符合表 2 的规定。

磁粉(MT)检测通用工艺规程111讲解

广州番禺潮流水上乐园建造有限公司 磁 粉 检 测 工 艺 规 程 工艺规程版本号:CL/Y01-2016 二零一六年一月一日

1.适用范围 本规程适应于本公司对大型游乐设施磁粉检测方法及质量分级的要求。 本规程适用于铁磁性材料制造的大型游乐设施的原材料、零部件和焊接接头表面、近表面缺陷的检测,不适于奥氏体不锈钢和其它非铁磁性材料的检测。 与大型游乐设施有关的支承件和结构件,如有要求也可参照本规程进行磁粉检测。 2. 规范性引用文件 下列文件中的条款通过NB/T47013-2015《承压设备无损检测》的本部分的引用而成为本部分的条款。凡是注日期的引用文件,其随后所有的修改单(不包括刊物的内容)或修订版均不适用于本部分,然而,鼓励根据本部分达成协议的各方研究是否使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本部分。 GB 11533-1989 标准对数视力表 GB/T 16673-1996 无损检测用黑光源(UV-A)辐射的测量 NB/T47013.1-2015 承压设备无损检测第1部分:通用要求 JB/T 6063-1992 磁粉探伤用磁粉技术条件 JB/T 6065-2004 无损检测磁粉检测用试片 JB/T 8290-1998 磁粉探伤机 3. 一般要求 磁粉检测的一般要求除应符合NB/T47013.1的有关规定外,还应符合下列规定。 3.1 磁粉检测人员 磁粉检测人员未经矫正或经矫正的近(距)视力和远(距)视力应不低于5.0(小数记录值为 1.0),测试方法应符合GB 11533的规定。并1年检查1次,不得有色盲。 3.2 磁粉检测程序 磁粉检测程序如下: a) 预处理; b) 磁化; c) 施加磁粉或磁悬液; d) 磁痕的观察与记录; e) 缺陷评级; f) 退磁; g) 后处理。 3.3 磁粉检测设备 3.3.1设备 磁粉检测设备应符合JB/T 8290的规定。本公司采用CJX-220E交流磁粉仪,仪器编号:15876

超声无损检测通用工艺

编制: 审核: 批准: 广西双起起重机制造有限公司 日期:2011年06月01日

超声波检测通用工艺规程 1 主要内容与适用范围 本标准规定了我公司采用超声检验方法检测起重机械(包括桥式和门式起重机,流动式起重机,塔式起重机,臂架起重机等)钢焊缝内缺陷的技术及验收准则。 本标准规定的超声检测技术,适用于检测母材厚度8mm-100mm结构钢全焊透熔化焊接接头;如果检测工艺规程得到合同各方的认可,也适用于母6mm-8mm无衬垫结构钢全焊透熔化焊对接焊接接头。 本标准所指的焊缝等级:1级是指重要受拉结构件的焊接接头;2级是指一般受拉结构件的焊接接头;3级是指受压结构件的焊接接头。 2 规范性引用文件 下列文件中的条款通过本标准的引用而成为要标准的条款。凡是注日期的引用文件,其随后所有修改单(不包括勘误的内容)货修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡注明日期的引用文件,其最新版本适用于本标准。 GB/T9445 无损检测人员资格鉴定与认证(GB/T9445-2005,ISO9712:1999,IDT) GB/T12604.1无损检测术语超声检测(GB/T12604.1,ISO5577:2000,IDT)GB/T18694 无损检测超声检测探头及声场的表征(GB/T18964-2002,eqv ISO 10375:1997) GB/T18852 无损检测超声检验测量接触探头声速特性的参考试块和方法(GB/T18852-2002;ISO 12715:1999,IDT) JB/T8428无损检测超声检测用试块 JB/T9214 A型脉冲反射式超声探伤系统工作性能测试方法 本公司采用检测标准为JB/T10559-2006、验收规范为《起重机械安全技术监察规程》 3 术语和定义 GB/T12604.1确立的术语和定义适用于本标准。 4 人员资格 起重机械钢焊缝的超声检测及最终验收结果的评定应由有资格和能力的人员来完成。相应等级的人员,应按GB/T9445或合同各方同意的体系进行资格鉴定与认证。

相关文档
最新文档