APIC_清洁验证指南_201609 中英文

APIC_清洁验证指南_201609 中英文
APIC_清洁验证指南_201609 中英文

ACTIVE PHARMACEUTICAL INGREDIENTS COMMITTEE (APIC)

GUIDANCE ON ASPECTS OF CLEANING VALIDATION

IN ACTIVE PHARMACEUTICAL INGREDIENT PLANTS

原料药工厂中清洁验证指南

Revision September 2016

Table of Contents 目录

1.0 FOREWORD 前言

This guidance document was updated in 2014 by the APIC Cleaning Validation Task Force on behalf of the Active Pharmaceutical Ingredient Committee (APIC) of CEFIC.

本指南文件于2014年由APIC清洁验证工作组代表CEFIC的APIC委员会进行了更新。

The Task Force members are:- 以下是工作组的成员

―Annick Bonneure, APIC, Belgium

―Tom Buggy, DSM Sinochem Pharmaceuticals, The Netherlands

―Paul Clingan, MacFarlan Smith, UK

―Anke Grootaert, Janssen Pharmaceutica, Belgium

―Peter Mungenast, Merck KGaA, Germany.

―Luisa Paulo, Hovione FarmaCiencia SA, Portugal

―Filip Quintiens, Genzyme, Belgium

―Claude Vandenbossche, Ajinomoto Omnichem, Belgium

―Jos van der Ven, Aspen Oss B.V., The Netherlands

―Stefan Wienken, BASF, Germany.

With support and review from:- 以下为提供支持和进行审核的人员

―Pieter van der Hoeven, APIC, Belgium

―Anthony Storey, Pfizer, U.K.

―Rainer Fendt, BASF, Germany.

A further revision of the guidance document has now been done in 2016 to bring it in line with the European Medicines Agency Guidance on use of Health Based data to set acceptance criteria for cleaning. The main changes were introduced in Chapter 4, Acceptance Criteria.

本指南文件进一步修订已于2016年完成,使其与EMA使用基于健康数据设定清洁可接受标准的指南保持一致。主要变化在是第4章“可接受标准”中。

The subject of cleaning validation in active pharmaceutical ingredient manufacturing plants has continued to receive a large amount of attention from regulators, companies and customers alike.

原料药生产工厂的清洁验证一直是法规人员、公司和客户等关注的问题。

The integration of Cleaning Validation within an effective Quality System supported by Quality Risk Management Processes should give assurance that API Manufacturing Operations are performed in such a way that Risks to patients related to cleaning validation are understood, assessed for impact and are mitigated as necessary.

原料药生产企业应将清洁验证与有效的质量体系相结合,由质量风险管理来支持,了解与清洁验证相关的患者风险,评估其影响,并在必要时降低风险。

It is important that the requirements for the finished manufacturing companies are not transferred back in the process to active pharmaceutical ingredient manufacturers without consideration for the different processes that take place at this stage.

重要的是,不能将对制剂生产企业的要求直接用于原料药生产商,而不考虑在此阶段所用生产工艺的差异。

For example, higher limits may be acceptable in chemical production compared to pharmaceutical production because the carry-over risk is much lower for technical and chemical manufacturing reasons

例如,与制剂生产相比,化学生产可以接受较高的残留限度,因为技术原因,化学生产所带入后续产品的残留风险会低很多。

The document reflects the outcome of discussions between APIC member companies on how cleaning validation requirements could be fulfilled and implemented as part of routine operations.

本文件反映了APIC成员公司之间关于如何满足清洁验证的要求及作为日常操作来实施的讨论结果。

In addition, APIC is aligning this guidance with the ISPE Risk MaPP Guide1that follows the Quality Risk Management Processes as described in the ICH Q9 Guidance on Quality Risk Management.

另外,APIC将本指南与“ISPE基于风险的药品生产指南”保持一致,遵守“ICH Q9质量风险管理”中的“质量风险管理流程”。

A further revision of the Guidance has now been done to include the general principles of the EMA Guideline2on setting health based exposure limits for determining safe threshold values for the cleaning of API’s in shared facilities.

对指南的进一步修订现已完成,其中包括了EMA设定基于健康的暴露限以决定共用设施中原料药清洁安全阈值指南中的通用原则。

The criteria of Acceptable Daily Exposure (ADE)or Permitted Daily Exposure (PDE) are now recommended to be used by companies to decide if Dedicated Facilities are required or not and to define the Maximum Acceptable Carry Over (MACO) of API’s in particular, in Multi-Purpose Equipment.

目前推荐公司使用“可接受日暴露水平(ADE)”标准或允许日暴露量(PDE)来决定是否专用设施需要界定原料药“最大可接受残留MACO”,特别是针对多用途设备。

Chapter 6 defines factors that should be considered in Controls of the Cleaning Process to manage the Risks related to potential chemical or microbiological contamination.

第6章对“清洁工艺的控制”中要考虑的因素进行了定义,以管理与潜在化学和微生物污染有关的风险。

The PDA Technical Report No. 29 – Points to Consider for Cleaning Validation3is also recommended as a valuable guidance document from industry.

也推荐企业将“PDA第29号技术报告----清洁验证中应考虑的问题”作为有用的指南文件进行参考。

1ISPE Baseline? Pharmaceutical Engineering Guide, Volume 7 – Risk-Based Manufacture of Pharmaceutical Products, International Society for Pharmaceutical Engineering (ISPE), First Edition, September 2010, https://www.360docs.net/doc/5011789044.html,.

2European Medicines Agency, EMA/CHMP/CVMP/SWP/169430/2012, Guideline on setting health based exposure limits for use

in risk identification in the manufacture of different medicinal products in shared facilities.

3Parenteral Drug Association (PDA) Guidance for Industry.Technical Report No. 29 (Revised 2012) Points to Consider for Cleaning Validation, Destin A. LeBlanc, Gretchen Allison, Jennifer L. Carlson, Koshy George, Igor Gorsky, Irwin S. Hirsh, Jamie Osborne, Greg Randall, Pierre-Michel Riss, George Verghese, Jenn Walsh, Vivienne Yankah.

The following topics are discussed in the PDA document: Cleaning process (CIP/COP): design and qualification

以下问题在PDA文件中进行了讨论:清洁工艺(CIP/COP):设计和确认

—Types of residues, setting acceptance criteria, sampling and analytical methods

—残留类型、设定可接受标准、取样和分析方法

—Maintenance of the validated state: critical parameters measurements, process alarms, change control, trending & monitoring, training and periodic review

—维护验证状态:关键参数测量、工艺警示、变更控制、趋势&监控、培训和周期性评审

—Documentation

—文件记录

2.0 Objective 目的

This document has been prepared to assist companies in the formulation of cleaning validation programmes and should not be considered as a technical standard but a starting point for internal discussions. The document includes examples on how member companies have dealt with specific areas and issues that arise when performing cleaning validation.

本文件的目的是帮助公司制订清洁验证程序,不能作为是一个技术标准,只应该作为内部讨论的出发点。本文包括了成员公司如何处理其特殊领域的例子,以及在实施清洁验证时提出的问题点。

3.0 Scope 范围

Six specific areas are addressed in this Guidance document:

本指南文件包括6个方面

●Acceptance Criteria

●可接受标准

●Levels of Cleaning

●清洁水平

●Control of the cleaning process

●清洁工艺的控制

●Bracketing and Worst Case Rating

●分类法和最差情况分级

●Determination of the amount of residue

●残留量的检测

●Cleaning Validation Protocol

●清洁验证方案

Finally, the most frequently asked questions are answered to give further guidance on specific points related to

cleaning validation.

最后是一些常见问题及回答,对一些与清洁验证有关的特殊情况给予指导。

4.0 Acceptance Criteria 可接受标准

4.1. Introduction 概述

Companies must demonstrate during validation that the cleaning procedure routinely employed for a piece of equipment limits potential carryover to an acceptable level. That limit established must be calculated based on sound scientific rational.

公司在验证时要证明各设备日常所用的清洁程序能将带入下一产品的潜在残留限制在一个可以接受的水平。所建立的限度必须进行科学合理的计算。

This section provides practical guidance as to how those acceptance criteria can be calculated. It is important that companies evaluate all cases individually. There may be specific instances where the product mix in the equipment requires further consideration.

本部分提供实用的指南,指导如何计算这些可接受标准。公司对各案进行各案评估是非常重要的。有时还需要考虑产品从哪步开始混入设备中。

The acceptance criteria preferably should be based on the Acceptable Daily Exposure (ADE) or Permitted Daily Exposure (PDE) calculations whenever this data is available.

如果可以获得可接受日暴露(ADE)值或允许日暴露量(PDE),最好依据其计算可接受标准。

The APIC Guidance refers primarily to ADE in the examples of calculations included in this chapter, in line with the ISPE recommended calculations.

在本章所举的计算例子中,APIC指南首先使用ADE,保持与ISPE推荐计算一致。

The ADE/PDE defines a limit at which a patient may be exposed every day for a lifetime with acceptable risks related to adverse health effects. Calculations of ADE/ PDE of API’s and intermediates are us ually done with involvement of industrial hygienists and toxicologists, who review all available toxicology and clinical data to set the limits. The justification of the calculation should be documented.

ADE/PDE定义的是患者终身每天暴露于该浓度,但对健康的不良影响仍处于可接受风险水平。原料药和中间体的ADE/PDE一般由企业的卫生学家和毒理学家来制订,他们会审核各种可以获得的毒性和临床数据来设定限度。计算的合理性要进行记录。

In many cases Occupational Exposure Limits (OEL) will be defined for API’s, Intermediates and Industrial Chemicals by Industrial Hygienists and toxicologists and the OEL data is then used to define containment measures such that operators are adequately protected while working with the chemicals.

在很多情况下,会由行业卫生学家和毒理学家对原料药、中间体和工业级化学品的职业暴露限度(OEL)值进行界定,这时应使用OEL数据来制订限制措施,例如,操作人员在操作化学物质时需要受到充分保护。

The OEL data can also be used to calculate the ADE for cleaning of equipment.

OEL数据也可以用于计算设备清洁的ADE值。

In certain cases where availability of pharmacological or toxicological data is limited, for example for chemicals, raw materials, intermediates or API’s in early phase clinical trials, cleaning limits base d on fraction of clinical

doses, LD50 or general cleaning limits may be calculated. In these cases, carcinogenic, genotoxic and potency effect of these structures should be evaluated by toxicologists.

在特定情况下,如果药性或毒性数据有限,例如,化学物质、原料、中间体或处于早期临床试验的原料药,其清洁限度可以基于临床剂量、半数致死量或一般清洁限度来计算。在这种情形下,需要有毒理学家对其结构的致癌性、基因毒性和效价影响进行评估。

The acceptance criteria for equipment cleaning should be based on visually clean in dry conditions and an analytical limit.

设备清洁的可接受标准应依据干燥状态下目视清洁及分析限度。

Unlike in pharmaceutical production, where residues on the surface of equipment may be 100 % carried over to the next product, in API production the carry-over risk is much lower for technical and chemical manufacturing reasons. Therefore all the following examples for calculating the limits can be adapted to the suitable situation by using different factors. A competent chemist with detailed knowledge about the equipment and the chemical processes and the properties of the chemicals involved such as solubility should justify this factor by evaluating the specific situation.

在制剂生产中,设备表面残留会100%被带入下一产品,而在原料药生产中,由于技术和化学生产原因,带入风险要低很多。因此,以下限度计算举例可以采用不同安全因子后用于适当的情形。应有一名具备设备和化学工艺知识,知晓所涉及化学品特性,如溶解度的化学家对特定情形下应使用的安全系统进行评估。

4.2. Methods of Calculating Acceptance Criteria 计算可接受标准的方法

4.2.1 Acceptance criteria using health-based data 采用健康基础数据的可接受标准

The Maximum Allowable Carryover (MACO) should be based upon the Acceptable Daily Exposure (ADE) or Permitted Daily Exposure (PDE) when this data is available. The principle of MACO calculation is that you calculate your acceptable carry-over of your previous product, based upon the ADE / PDE, into your next product.

在可以获得可接受日暴露水平(ADE)或允许日暴露量(PDE)值时,最大允许残留(MACO)应基于ADE计算。MACO计算的原则是基于ADE/PDE值,计算允许从你的上一个产品带入下一个产品中的残留量。

Procedure 程序

Calculate the ADE (Acceptable Daily Exposure)or PDE (Permitted Daily Exposure)according to the following equation and use the result for the calculation of the MACO.

根据以下公式计算ADE值或PDE值,将结果用于MACO值的计算:

NOAEL × BW

ADE =

UFc × MF × PK

NOAEL × BW

PDE =

F1 × F2 ×F3×F4×F5

From the ADE/PDE number, a MACO can be calculated according to:

根据以下公式从ADE/PDE值计算MACO值:

ADE/PDE previous × MBSnext

MACO =

TDDnext

ADE/PDE上一产品× MBS下一产品

MACO =

TDD下一产品

with most active API (lowest ADE) is chosen to end up in the following API with the smallest ratio of batch size divided with TDD (MBS/TDD ratio).

可以选择最差情况方案来替代对每个可能的产品更换情况下的残留计算。这时,可以选择活性最强的原料药(ADE最低)作为上一产品,选择批量TDD比值(MBS/TDD比值)最小的原料药作为后续产品。

If OEL data is available, the ADE can be derived from the OEL.

如果可以获得OEL值,则可以从OEL值计算ADE值。

4.2.2. Acceptance criteria based on Therapeutic Daily Dose 基于日治疗剂量的可接受标准

When limited toxicity data is available and the Therapeutic Daily Dose (TDD) is known, this calculation may be used. It is used for final product changeover API Process —A to API Process —B.

如果可以获得有限毒性数据和日治疗剂量(TDD)值,可以采用本计算方式。它可以用在原料药生产工艺A更换到原料药生产工艺B。

Procedure 程序

Establish the limit for Maximum Allowable Carryover (MACO) according to the following equation.

根据以下公式建立允许最大残留(MACO)值:

TDD previous × MBSnext

MACO =

SF × TDDnext

TDD上一产品× MBS下一产品

MACO =

SF × TDD下一产品

4.2.3. Acceptance criteria based on LD50 基于半致死量的可接受标准

In cases where no other data is available (e.g. ADE, OEL, TDD,…) and only LD50 data is availabl e (e.g. chemicals, intermediates, detergents, …), the MACO can be based upon LD50 data.

如果没办法获得其它数据(例如,ADE、OEL、TDD等值),只能获得半数致死量数据(例如化学物质、中间体、清洁剂……),MACO可以基于半数致死量数据来计算。

Procedure 程序

Calculate the so called NOEL number (No Observable Effect Level) according to the following equation and use the result for the establishment of MACO (See [3] on page 53 - for reference).

根据以下公式,计算NOEL值(无可见影响水平),用于建立MACO值(参见第53页的【3】部分,供

参考)

LD50× BW

NOEL =

2000

From the NOEL number a MACO can be calculated according to:

从NOEL值,用以下公式计算MACO值:

NOELprevious × MBSnext

MACO =

SFnext × TDD next

NOEL上一产品× MBS下一产品

MACO =

SF下一产品×TDD 下一产品

employed when manufacturing APIs to be administered in oral dosage forms.

安全系数(SF)根据摄入途径不同而不同(见下)。一般系数200用于口服剂型原料药生产。Safety factors: 安全系数

4.2.4 General Limit as acceptance criteria 可接受标准的一般限度

If MACO calculations result in unacceptably high or irrelevant carryover figures, or toxicological data for intermediates are not known, the approach of a general limit may be suitable. Companies may choose to have such an upper limit as a policy. The general limit is often set as an upper limit for the maximum concentration (MAXCONC) of a contaminating substance in a subsequent batch.

如果MACO计算结果太高,不能接受,或者与带入数字不相关,或中间体毒性数据未知,则适用通用限度方法。公司可以选择例如一个最高限度作为原则。通用限度一般设定为一种污染物质在后续批次中最大浓度上限(MAXCONC)。

Procedure 程序

Establish MACOppm, based on a general limit, using the following equations.

利用以下公式,基于一个通用限度建立MACO限度,ppm为单位。

MACOppm = MAXCONC x MBS

E.g. for a general limit of 100 ppm: MACO = 0.01% of the minimum batch size (MBS), and for a general limit of

10 ppm: MACO = 0.001% of the minimum batch size (MBS).

例如,对于通用限度为100ppm:MACO = 最小批量(MBS)的0.01%,对于通用限度为10ppm:MACO = 最小批量(MBS)的0.001%。

A general upper limit for the maximum concentration of a contaminating substance in a subsequent batch (MAXCONC) is often set to 5-500 ppm (100 ppm in APIs is very frequent) of the previous product into the next product depending on the nature of products produced from the individual company (e.g. toxicity, pharmacological activity …).

根据各公司所生产产品的属性不同(例如,毒性、药物活性等),从上一产品带入下一产品中的污染物质最大浓度通用上限通常设定为5-500ppm(原料药中100ppm是很常见的)。

The Threshold of Toxicological Concern (TTC) concept could be applied to intermediates or API’s with no clinical (e.g. early development) or toxicological data. This concept includes three categories of products with limited or no data:

毒性关注阈值(TTC)概念可以应用于没有临床(例如早期研发阶段)或毒性数据的中间体或原料药。这个概念将数据有限或没有数据的产品分为3个类别

●Products that are likely to be carcinogenic;

●可能致癌的产品

●Products that are likely to be potent or highly toxic;

●可能具有效价或高毒性的产品

●Products that are not likely to be carcinogenic, potent or highly toxic.

●可能致癌、具有效价或高毒性的产品

The corresponding ADE’s recommended for these three categories are 1, 10, 100 μg/day, respectively.

对应此三类所推荐的ADE值分别为1、10和100μg/天。

Note - If you decide to employ the concept of levels of cleaning (ref. section 5), then different safety factors (ppm limits) may be used for different levels. Especially if the product cleaned out is within the same synthetic chain and covered by the specification of the API, much higher (qualified) levels are acceptable.

注:如果你决定采用清洁水平概念(参见第5部分),则对于不同水平可以采用不同的安全系数(ppm限度)。特别是如果被清洁的产品是在同一条合成链中,且其限度包括在原料药的质量标准中,则残留水平较高(确认过的)时也是可以接受的。

4.2.5 Swab Limits 擦拭限度

If homogeneous distribution is assumed on all surfaces, a recommended value can be set for the content in a swab. The maximum allowable carry over from one batch to another can be established based on e.g. ADE, NOEL or TDD (see above). If the total direct contact surface is known, the target value for contamination per square meter can be calculated according equation 4.2.5-I. This can be used as basic information for preparation of a method of analysis and detection limit.

如果假定所有表面上残留的分布是均匀的,可以给擦拭样品设定一个推荐值。可以根据例如ADE值、NOEL 或TDD(见上)设定一批到另一批的最大允许残留值。如果知道直接接触产品的总面积,则可以根据4.2.5-I 公式计算单位面积上的污染目标值,该值可以在制订方法验证方案和检测限值时参考。

MACO[μg]

Equation 4.2.5-I Target value [μg/dm2] =

Total surface [dm2]

MACO[μg]

公式 4.2.5-I 目标值[μg/dm2] =

总表面积[dm2]

Also other methods with different swab limits for different surfaces in a piece of equipment and/or equipment train can be used. If the equipment can be divided in several parts, different swab limits may be taken for the different parts building up the equipment train. If the result of one part is exceeding the target value, the whole equipment train may still be within the MACO limit. The Carry Over is then calculated according equation

4.2.5-II (see below).

也可以对同一设备和/或设备链不同的表面使用不同的擦拭限度。如果设备被分为几个部分,对可以针对设备链不同部分采用不同的擦拭限度。如果一个部件的结果超出了目标值,整个设备链的残留值仍可能是在MACO的限度以内。这时,可以按公式4.2.5-II(见下)计算残留量。

During equipment qualification and cleaning validation hard to clean parts can be determined. Rather than declaring the hard to clean part as the worst case swab limit for the whole equipment train, it could be separated and dealt with as mentioned above. It should be noted that different types of surfaces (e.g. stainless steel, glass lined, Teflon) may show different recoveries during swabbing. In those cases it may be beneficial to divide the equipment train in several parts, and combine the results in a table or matrix. The total calculated amount should

be below the MACO, and the individual swab results should not exceed the maximum expected residues established during cleaning validation / equipment qualification. Recovery studies and method validation are necessary when applying swabbing as a method to determine residues.

在设备确认和清洁验证中,可以确定哪个部件是难以清洁的。其实可以采用上述的方法来将难以清洁的部件分开来,而不需要采用最难清洁的部件作为最差擦拭情况的限度用于整个设备链。要注意不同材质表面(例如,不锈钢、搪玻璃、聚四氟乙烯)可能有不同的擦拭回收率。在这种情况下,如果把设备链划分为几个部分,将结果在一份表或类别中合并可能会比较好。合计数量应低于MACO值,单个擦拭结果不应超过在清洁验证/设备确认中所设立的最大高期望值。在使用擦拭方法测定残留量时,要进行回收率研究和方法验证。

Equation 公式4.2.5-II

CO [μg] = Σ(Ai[dm2] ×mi[μg/dm2])

4.2.

5.1. Setting Acceptance Criteria for Swab Limits 对擦拭限度设定可接受标准

For each item tested, the following acceptance criteria (AC) apply.

以下可接受标准适用于各测试项目:

AC1. The cleaning result of an individual part should not exceed the maximum expected residue.

单个设备清洁结果应不超过最大可接受残留量。

AC2. For the total equipment train the MACO must not be exceeded.

总设备链的MACO不得超过。

In determining acceptance limits, all possible cases of following products in the relevant equipment shall be taken into account. It is proposed that a matrix be set up in which the limits for all cases are calculated. Either acceptance criteria for each product in the equipment can be prepared or the worst case of all product combinations may be selected.

在制订可接受限度时,要考虑在相关设备中可能生产的所有后续产品。建议画出矩阵图,在其中对所有情况下的限度进行计算,然后针对在该设备中生产的每个产品分别制订可接受标准,也可以对所产品选择最差情况下的可接受标准。

4.2.

5.2. Evaluation of results 结果评估

When all surfaces have been sampled and the samples have been analyzed, the results are compared to the acceptance criteria. Companies may find it easier to evaluate against the MACO. However, it is advisable to have

a policy for swa

b limit as well. Especially because analytical methods are validated within a certain range for swab results. Another reason is that some pieces could be very contaminated, and it is not good practice to clean certain pieces very thoroughly in order to let others be dirty. Thus, limits for both MACO and swabs should be set.

在对所有表面取样后,对样品进行分析,将结果与可接受标准进行比较。公司可以发现采用MACO来评估会比较容易。但是,还是建议对于擦拭限制订一个原则,主要是因为擦拭样品分析方法的验证是在一定的浓度范围内进行的。另一个原因是有一些部件的污染可能会比较严重,没有理由让一些部件清洁的非常彻底而让另一些部件很脏。因此,应同时设定MACO限度和擦拭限度。

4.2.6. Rinse Limit 淋洗限度

The residue amount in equipment after cleaning can also be determined by taking rinse samples. During equipment qualification it should be established that all direct content parts of the equipment is wetted / reached by the rinsing solvent. After the last cleaning cycle (last rinse), the equipment should be assesse d as ‘clean’. In some cases it may be advisable to dry the equipment in order to do a proper assessment. Thereafter, the rinse cycle can be executed, and a sample taken (sampling rinse). The procedure for the rinse cycle and sampling should be well established and described to assure repeatability and comparability (cycle times, temperatures, volumes, etc.). The choice of the rinse solvent should be established during cleaning validation, taking into account solubility of the contaminations, and reactivity of the rinse solvent towards the contaminants (saponification, hydrolyses, etc). Method validation is needed.

设备清洁后的残留量也可以采用淋洗样来检测。在设备确认时,应该识别出设备中所有可以被淋洗溶剂淋到的部件。在最后清洁(最后淋洗)结束后,设备状态应评估为“清洁”方可取样。有时,需要对烘干设备以便进行适当的评估。之后,对设备进行淋洗,取样(淋洗样)。应制订书面程序描述淋洗和取样操作,以保证其可重复性和可比较性(重复次数、温度、体积等)。在清洁验证时应对淋洗用溶剂作出选择,选择时应考虑污染物的溶解度,以及淋洗用溶剂与污染物之间的反应活性(皂化反应、水解反应等)。淋洗方法要进行验证。

In a worst case approach, the amount of the residue in the equipment can be assumed to be equal to the amount determined by analysis of the rinse sample. This can be supported by rinse studies that show a strong decay of a residue in a piece of equipment.

如果采了最差情形方法,可以假定设备中的残留量与对淋洗样品的检测结果相等。这个假设可以通过对一个设备部件上淋洗前后残留物急剧减少来支撑。

The MACO is usually calculated on each individual product change over scenario according to the procedures outlined above and individual acceptance criteria are established using the following equation:

通常根据上述所列的方法,针对各个产品更换的情况计算MACO。采用以下公式,可以计算出单个可接受标准:

Target value (mg/L) = MACO (mg) / Volume of rinse or boil (L)

目标值= MACO/淋洗溶剂体积

For quantitation a solvent sample (e.g. 1 L) is taken, the residue in the sample is determined by a suitable analytical method and the residue in the whole equipment is calculated according to the following equation:

对于一定的取样体积(例如1升),采用适当的分析方法测定样品中的残留量,根据以下公式计算整个设备中的残留量:

M = V*(C-Cb)

Requirement: M < Target value.

要求:M < 目标值

The requirement is that M < target value. If needed, the sample can be concentrated before analysis.

要求是M < 目标值。那天要时,样品在检测前可以浓缩。

The choice for swab or rinse sampling usually depends on the type of equipment. Areas to be swabbed are determined during equipment and cleaning validation (‘hard to clean areas’), and are preferably readily accessible for operational reasons, e.g. near the manhole. If swabbing of the indicated area is not easy, rinse sampling is the alternative. The advantage is that the whole surface of the equipment is sampled for contamination, being provided that during equipment qualification, surface wetting testing was taken into account. Thus equipment used for milling, mixing, filters, etc. are usually swabbed, whilst reactor systems are usually sampled by rinsing.

选择擦拭样品还是淋洗样品通常取决于设备的类型。擦拭取样点应在设备验证和清洁验证中确定(难以清洁点),最好还要易于操作,例如接受人孔处。如果要取样的地方很难采用擦拭取样,可以采用淋洗取样。淋洗取样的优点是设备的整个表面都能被取样测试污染程度。淋洗取样时,要考虑表面润湿测试,该测试应在设备确认期间完成。鉴于此,用于粉碎、混合、过滤等的设备一般采用擦拭取样,而反应釜系统一般采用淋洗取样。

4.2.7 Rationale for the use of different limits in pharmaceutical and chemical production 在药品和化学生产中使用不同限度的合理性

Unlike in pharmaceutical production, where residues on the surface of equipment may be 100 % carried over to the next product, in API production the carry-over risk is much lower for technical and chemical manufacturing reasons. Thus higher limits may be acceptable in chemical production compared to pharmaceutical production. For example chemical processing steps often include dissolution, extraction and filtration steps that are likely to reduce significantly any residue left from previous production and cleaning operations. A factor of 5-10 could

be applied to the MACO calculated using the Acceptable Daily Exposure Limit or the secondary criteria defined in the previous sections.

在药品生产中,设备表面残留可能会100%被带入下一产品。与之不同的是,在原料药生产中,由于技术和化学生产原因,残留带入风险要低很多。因此,与药品生产相比,在化学生产中采用较高的残留限度是可以接受的。例如,化学工艺步骤经常包括溶出、提取和过滤,这些步骤可能会显著降低上一产品和清洁操作所残留的东西。如果采用ADEL值计算MACO,则可以使用5-10的安全系数,或者采用上述部分中界定的中等标准。

In all cases, the limits should be justified by a competent chemist with detailed knowledge about the equipment

and the chemical processes, following Quality Risk Management Principles and the limits should be approved by Operations and Quality Assurance Managers.

在所有情况下,所有的限度均应由具备资质的化学家进行论证。他应该具备关于设备和化学工艺的知识,遵守质量风险管理原则。所制订的限度应由操作和质量保证经理批准。

The following description shows an example where the carry-over risk for a residue in chemical production equipment is much lower than in pharmaceutical production equipment.

以下例子说明了在化学生产设备中,其残留的带入风险比药品生产设备要低很多。

Assuming that the common criteria (ADE, 1/1000th dose, LD50 NOEL/ADI with SF 100-1000, 10 ppm) represent the state of the art for pharmaceutical production and are considered sufficiently safe, then the calculation of limits in API manufacture must reflect the different processes in pharmaceutical production and in the chemical production of active pharmaceutical ingredients to allow comparable risk analyses to be undertaken.

假定常用标准(ADE,1000分之一剂量,LD50 NOEL/ADI安全系数100-1000,10ppm)代表药品生产理想状态,被认为是足够安全的,这时原料药生产中的限度计算必须反映化学原料药生产与药品生产工艺的不同,使得可以进行风险分析比较。

Pharmaceutical production, Chemical production physical process 药品生产、化学生产的物理处理

In pharmaceutical production a residue remaining on the surface of equipment after cleaning is, in the next production cycle, distributed in a mixture of active substance and excipients if it does not remain on the surface. In the worst case it will be 100 % transferred to the first batch of next product.

在药品生产中,清洁后残留保存在设备表面,在下一个生产循环中,如果这些残留不再停留在设备表面,则会分布在原料药和辅料的混合物中。最差情况是这些残留100%地被带入下一产品的第一个批次。

Chemical production/processing 化学生产/加工

In chemical production a 100 % carry-over of residue from the equipment surface to the next product to be manufactured is very unlikely based on the way the process is run and on technical considerations. The residue remaining on the equipment surface can, during the next production cycle, be carried over into the reaction mixture consisting of solvent and raw materials. In most cases, however, any residue in solution will be eliminated from the process together with the solvent, and insoluble residue by physical separation processes (e.g. filtration), so likely carry over into the end-product will be low.

在化学生产中,考虑到工艺运行的方式,以及技术问题,残留物被100%地从设备表面带入下一产品中的情形不太可能发生。残留在设备里的东西,在下一生产循环中,会被带入溶剂和原料所组成的混合反应液中。在大多数情况下,所有溶液中的残留都会与溶剂一起被从工艺中去除,不溶性残留会被物理分离工艺(例如过滤)减少,因此,可能被带到最终产品中的残留会很低。

The final step in a multi-step chemical synthesis is selective purification of the API (e.g. by crystallization), during which contaminants are removed from the process and/or insoluble residues are removed by physical separation). From the original reaction mixture of educt, agent and solvent there remains only a fraction of the original mass as API at the end of the chemical process.

在多步化学合成的最后一步,一般是原料药选择性精制(例如,通过结晶方式)。在精制过程中,污染物被从工艺中去除,不溶性残留被物理分离所去除。在经过这些化学工艺后,原来那些由离析物、试剂和溶剂所组成的混合反应液只剩下一些原来物质的片断,在最后成为原料药。

【译者:第一句有一个半括号,原文如此】

It is also to be noted that, during subsequent pharmaceutical production, the API is further diluted through the excipients that are added.

还要注意的一点是,在后续的药品生产过程中,原料药通过加入辅料被进一步稀释了。

Conclusion: 结论

Assuming that there is no intention to impose more stringent yardsticks during API production than in

pharmaceutical production but that they should be approximately the same, the logical conclusion is that the limits in chemical production should be set higher than in pharmaceutical production. Based on this rationale, a factor of 5 - 10 compared to the established pharmaceutical production limits is both plausible and, in terms of pharmaceutical risk, acceptable.

假定我们并无意将比药品生产更严格的标尺强加给原料药生产,而只是要将它们保持大致相同,则从逻辑上得到的结论就是在化学生产中的限度应该设定得比药品生产中的限度要高。基于此理论,相比于已建立的药品生产限度,对原料药生产采用5-10的安全系数既貌似合理,从药品风险角度来说,也是可以接受的。

清洁后设备

表面的残留残留物溶解

溶剂和残留物

残留物溶解在

废溶剂中 新原料药在反

应液中结晶 新原料药

Chemical production “physical processes” (drying, mixing, filling, ...) 化学生产的“物理处理”(干燥、混合、充填……)

Apparatus and equipment that is used for physical end-treatments such as drying, mixing or milling may either be operated together with the previous synthesis equipment or generally be used separately. During separate physical end-treatments of APIs, there is no decrease of contaminants compared to the aforementioned chemical process. Consequently, we recommend in this case that the calculation methods applied should be those normally used in pharmaceutical production, (ADE, 1/1000th dose, LD50 NOEL/ADE with SF 100-1000, 10 ppm). The Limits for carry over into the final API should be the same as those calculated in the previous sections.

用于最终物理处理,如干燥、混合或磨粉,的设备仪器,可以与之前的合成设备一起使用,通常是单独使用。在原料药单独的物理最终处理过程中,与之前提到的化学过程相比,其污染物不会减少。因此,我们推荐在这种情况下,应采用制剂产品中常用的计算方法(ADE、千分之一剂量、半数致死量、NOEL/ADE 和安全系统100-1000、10ppm)。带入最终原料药的残留量限度应与之前各部分所计算的相同。

ANNEX 1: Examples of MACO calculations.

附录1:MACO计算的例子

Example 1: ADE calculation

例1:ADE计算

Product A has a NOAEL70kg of 100 mg/day human oral dose. Uncertainty factors applied to calculate the ADE are an UFS of 3 (extrapolation from an acute dose to subchronic/chronic dosing) and UFH of 8.13 (the inter-individual variability based upon a PK (kinetic component) of 2.54 and PD of 3.2 (dynamic component)). The MF is 10 (extrapolation from a ‘generally healthy’ population to a more susceptible sick patient population). Product B is an oral product (PK = 1).

A产品NOAEL70kg人类口服剂量为100mg/天,用于计算ADE的不确定因子UFS为3(从急性剂量到亚慢性/慢性给药外推得到),UFH为8.13(根据PK(动力学组成)为2.54和PD为3.2(动力学组成)所得的内在个体变化)。MF为10(从“一般健康”人群外推至易感人群)。

产品B为口服产品(PK = 1).

ADE = 100(mg/day)

= 410(μg/day)3×8.13×10×1

Result: ADE oral is 410 μg/day

结果:口服ADE值为410μg/天

If product B is a parenteral product and the PK is 62.5 (based upon an oral bio-availability study in human after parenteral).

如果产品B是一个注射产品,PK值为62.5(基于人体注射后的口服生物利用度研究)

ADE = 100(mg/day)

= 6.6(μg/day)3×8.13×10×62.5

Result: ADEparenteral is 6.6 μg/day 结果:注射ADE值为6.6μg/天

2020年度WHO清洁验证指南

2020年度WHO清洁验证指南(中文版) 附录3 清洁验证 世界卫生组织药物制剂规范专家委员会第十四次报告。日内瓦,世界卫生组织;2006:附件4(世卫组织技术报告系列第937号) 1.原则 2.范围 3.概述 4.清洁验证方案和报告 5.人员 6.设备 7.清洁剂 8.微生物 9.取样 10.分析方法 11.确定可接受标准 (1)原则 1.1药品质量管理规范(GMP)的目标包括防止可能的污染、药物原料和产品的交叉污染。 1.2药品可能被各物质污染,如与微生物有关的污染物,产品(包括原料药和赋形剂残留)、清洁剂、空气传播的物料,如微尘和颗粒物。润滑剂和辅料材料,如消毒剂、残留降解产物:例如,在清洗的过程中使用强酸和强碱会导致产品残渣分解。洗涤剂、酸和碱的分解产物,可作为清洗工艺的一部分。 1.3适当的清洗程序对防止污染和交叉污染具有重要作用。清洗方法的验证需提供文件证明,经批准的清洗程序将提供与预期用途相适应的清洁设备。 1.4清洁验证的目的是证明设备对产品、洗涤剂和微生物残留物的清洗均能达到可接受水平,以防止可能的微生物污染和交叉污染。 1.5清洁验证对于非关键性的清洗并不一定是必须的,例如批次相同的产品(或散装过程中相同中间体的不同批次)、地板、墙壁、容器外部以及一些中间步骤

之间的清洗。 1.6清洁验证在多产品生产设备清洁中是很重要的,并应在设备、消毒程序和服装洗涤等方面进行验证。 2.范围 2.1指南里描述了清洁验证的一般方面,不包括可能需要的特殊清洁验证或灭活,例如,在生物制造业中去除病毒或支原体污染物。 2.2一般情况下,清洁验证适用于关键清洁,例如,在生产一种产品与另一种产品,与产品、药品和原料药接触的表面的清洗。 3.概述 3.1要有详细的书面标准操作规程(SOP),说明设备和仪器的清洗过程。清洗程序应该经过验证。 3.2制造商应制定清洗策略和一定的清洗验证程序,包括:与产品的接触表面;产品转换后的清洗(当一种药物配方被另一种完全不同的配方替换时);在批次之间的活动(当同一配方是在一段时间内,在不同的日期生产);用于清洁验证的产品组。(这种情况经常发生在产品中含有具有类似性质(如溶解度)或具有不同强度的相同物质的地方。一种可接受的策略是首先制造含量较低的剂型(不一定是最低剂量),然后是含量较高的形式。)有时产品的“组”在活性物质或赋形剂方面略有不同。需定期评估和再清洁验证之间生产的批次数。 3.3至少连续三次应用清洁程序,并证明是成功的,以证明该方法是有效的。 4.清洁验证方案和清洁验证报告 4.1清洁验证应在清洁方案中进行描述,该方案应得到正式批准,例由质量控制或质量保证部门批准。 4.2在制定清洁验证方案时,应考虑一下事项: 系统拆卸 预清洗 清洁剂、浓度、溶液体积、水的质量 时间和温度 流速、压力和冲洗 设备复杂性及设备设计

原料药生产设备清洁验证的范围和程度评估

原料药生产设备清洁验证的范围和程度评估 全合成前天 工艺设备的清洁很多年前已经成为药品生产安全的一部分,世界各国GMP 均对设备的清洁提出要求。我国新版GMP 中规定:清洁方法应当经过验证,证实其清洁的效果以有效防止污染和交叉污染。清洁验证应当综合考虑设备使用情况、所使用的清洁剂和消毒剂、取样方法和位置以及相应的取样回收率、残留物的性质和限度、残留物检验方法的灵敏度等因素。 美国FDA 的cGMP 中提到“间隔一定时间应该对设备和用具进行清洗、维护和消毒,防止可能的故障和污染及改变药品安全性、均一性、效价、质量和纯度”。欧盟GMP 中提到“生产设备的设计必须容易进行彻底清洁,必须按照详细的书面操作规程进行清洁并贮存在清洁干燥的条件下。洗涤和清洁设备必须正确选择,保证在使用时不会带来污染”。严格来说,任何一种清洁方法均无法将设备中的残留物完全清除,清洁验证的目的就是评价一个清洁方法的可行性和有效性。清洁验证的结论是否正确,是否能够证明某一清洁程序的有效性,则取决于清洁验证中所用策略或方法的科学性和合理性。 1 原料药生产的一般特点 原料药是指通过化学合成、半合成以及微生物发酵或天然产物分离获得的,经过一个或多个化学单元反应及其操作制成的,用于制造药物制剂的活性成分,简称API(active pharmaceutical ingredient)。原料药的工艺复杂多样,往往包含复杂的化学变化或生物变化过程。一般而言,在制剂生产过程中,物料很少有化学结构的变化,

但在API 生产过程中,物料的化学结构变化是经常发生的,往往会产生副产物,最终通常需要纯化。另外,由于API 制备工艺过程较长,往往包含多个子工序和反应步骤,因此涉及众多生产设备。根据化学合成API 的一般生产工艺流程( 图1) ,所需设备主要包括反应釜、过滤器、离心机、干燥机、粉碎机、混合机等。 清洁验证的最终目的是减少污染和交叉污染。API 生产中的污染可能更多地来自于设备中物料的降解。值得注意的是,API 生产中的同一反应设备可能会用于不同的反应,这种情况就需考虑交叉污染。API 生产的工艺特点以及设备特点,决定了其生产清洁验证是一项工程量很大的工作。因此,如何在有效合理的评估下确定清洁验证的范围和程度显得十分必要和需要。 2 原料药生产清洁验证范围的确定

清洁验证方案

片剂生产线清洁验证方案(2010年) 编号:SVP-QJ-001-01

人员会签表 一、概述 固体口服制剂在生产过程中,由于存在粉尘和大量固体残留物,在每批生产结束时如果设备清洗不彻底,容易对下个批号的产品产生污染。因此,每批生产结束后必须按照相应的清洁规程对所用生产设备进行清洁。为评价设备清洁规程的效果,必须进行清洁验证。 口服固体制剂车间片剂生产线的主要设备有HLSG-200高效湿法制粒机、YK160-C摇摆式颗粒机、CT-C-Ⅱ热风循环烘箱、HD-800三维运动混合机、BG-150高效包衣机、STP-ZB35B压片机。 片剂生产线上生产的品种有,本方案中选用检测微生物限度和化学分析检测化学残留来检查设备清洁后残留的污染物,进行生产后的清洁效果验证。 二、验证目的 设备清洁验证采用化学分析和微生物检测方法,来检查该设备经清洗后所残留的污染物量是否符合规定的限度标准。本验证方案选择最不利清洁条件,对口服固体制剂片剂生产线主要设备的清洁程序进行验证。采用棉签擦拭法取样,对设备清洁后的残留进行化学检验和微生物检验,并将所得结果与可接受限量进行比较。若检测结果均低于其相应规定限量,则可证实设备清洁程序的有效性及稳定性。从而消除换品种或设备清洗不彻底而造成残留物对下一个生产药品污染的发生,有效地保证药品质量,防止交叉污染。因此,清洁验证不仅为设备清洁规程提供技术依据,同时也是设备清洁规程有效性评价的控制标准。这也是此次清洁验证的主要目的。 三、验证人员与职责: 四、验证的安排 进行设备清洁验证前,所有与验证有关的设备、仪器等均已经过验证,仪表、计量器具等已校验合格,检验方法经验证证明符合清洁验证对准确度、精密度、选择性的要求,设备、仪器等已建立相应的操作规程、维护保养规程,对验证试验的样品已建立相应的检验操作规程。对实验的取样方法(取样回收率实验)和设备的最低检测限度均已

设备清洁验证管理规程

1.目的:建立设备清洗验证管理规程,以规设备清洗的验证工作。 2.围:本规程适用于安装试用前后设备、大修后设备、全部生产完成后设备清洁的验证。 3.职责:公司质量负责人、验证小组成员及各部门负责人对本规程的实施负责。 4.依据:《药品生产质量管理规》(2010年版)附录:确认与验证 5.程序 5.1清洁验证定义 有文件和记录证明所批准的清洁规程能有效清洁设备,使之符合药品生产的要求。5.1.1清洁验证注意事项 清洁验证应综合考虑设备使用情况、所使用的清洁剂和消毒剂、取样法和位置以及相应的取样回收率、残留物的性质和限度、残留物检验法的灵敏度等因素。 5.1.2清洁验证的一般要求 清洁验证是通过文件证明清洁程序有效性的活动,目的是确保产品不会受到来自于同一设备上生产的其他产品的残留物、清洁剂以及微生物污染; 为了证明清洁程序的有效性,清洁验证的次数应当根据风险评估确定,通常应至少执行连续三个成功的清洁循环;清洁验证计划完成需要一定的时间,验证过程中每个批次后的清洁效果需及时进行确认;根据清洁验证结果,必要时,在清洁验证后应当对设备的清洁效果进行持续确认。

对于专用设备,清洁验证可以不必对活性成分进行考察,但必须考虑清洁剂残留以及潜在的微生物污染等因素,对于一些特殊的产品,还应考察降解产物; 对于没有与药物成分接触的设备,清洁验证可以不必对活性成分进行考察,但必须考虑清洁剂残留及微生物污染等因素; 清洁验证中需对下列放置时间进行考察,进而确定常规生产中设备的放置时间: ①设备最后一次使用与清洁之间的最大时间间隔(“待清洁放置时间”) ②设备清洁后至下次使用的最大时间间隔(“清洁后放置时间”) ③当采用阶段性生产组织式时,应当综合考虑阶段性生产的最长时间和最大批次 数量,以作为清洁验证的评价依据(最长连续生产期) 5.2清洁验证流程 清洁验证前提条件 ①清洁规程已经批准,包括关键清洁程序的参数围

制药厂压缩空气系统清洁验证方案(完整版)

1. 引言 1.1 验证方案名称:压缩空气系统的清洁验证方案1.2 验证方案编号:MC-Y03-002 1.3 验证方案审批表 1.4验证小组成员及职责

验证方案会签页

目录 1.引言 2.验证目的 3.验证使用文件 4.验证范围 5.验证条件 6.清洁灭菌的方法与检验合格的标准7.验证实施 8.清洁过程QA监控 9.验证实施时间进度安排及周期 10.验证实施过程的整理、验证报告的书写11.原始记录保存地点 12.附件

压缩空气系统的清洁验证方案 1.概述 ×××××制药有限公司设有前处理车间、前处理提取、口服固体制剂三个生产车间,生产片剂、胶囊剂、颗粒剂、丸剂、胶剂、散剂、煎膏剂七个剂型。根据工艺要求,生产车间共设4个用气点,温度要求均为常温。用气点分别为:多功能中药灭菌、干燥制粒、高效包衣、铝塑泡罩包装等。 根据工艺要求,设计产气量为2.4m3/min,排气压力0.7MPa,所有单元设备的结构制作、材料及采用的管件阀门均采用304不锈钢,满足GMP的要求;整个系统全自动运行;工作流程合理,保证系统出气气质稳定,确保系统运行安全可靠。气体质符合《中国药典》2000年版药用气体的要求。 2.验证目的 验证压缩空气系统清洁消毒规程的效果。“药品生产质量管理规范”明确要求压缩空气系统的制备、储存和分配应能防止微生物的滋生和污染,储罐和输送管道所用材料应无毒、耐腐蚀。管道的设计和安装应避免死角、盲管。本系统的管道和阀门材料均采用304不锈钢,管道的连接应用氩弧焊接。本公司的压缩空气分配系统材料均采用304不锈钢材料,连接采用氩弧焊避免管道接头的死角滋生微生物。 3.验证所需文件 臭氧消毒灭菌操作规程 压缩空气系统的标准操作规程 压缩空气系统的标准清洁规程 4.验证范围 压缩空气系统的清洁验证 5.验证条件 5.1设备条件 5.1.1压缩空气系统为完好系统。

清洁验证管理规程

清洁验证管理规程 你的签名表明你已清楚了解本文件及附件内容,充分理解并认可本文件的所有条 任何对本文件及其附件的目的、内容或标准进行的改变或修正都必须起到改善的作用,并详细记录文件 的修订及变更历史(详见变更记录),并且在执行以前必须取得批准,下表仅记

1. 目的 用于规范广西双蚁药业有限公司清洁验证工作管理工作。 2. 范围 适用于广西双蚁药业有限公司清洁验证的实施与管理。 3. 术语或定义 N/A 4. 职责 4.1 生产车间工艺员负责制定、修订和培训设备清洁方案。 4.2 生产操作人员负责按照批准的清洁程序对设备进行清洁。 4.3 QC 人员负责制定清洁验证相关的分析方法和清洁验证过程中的取样工作。 4.4 QA 人员负责清洁验证方案及报告的审核,负责清洁验证过程中偏差的处理及变更控制。 5. 程序 5.1 概述 清洁验证实际就是对清洗标准操作规程的验证,通过验证建立合适的设备清洁标准操作规程。 清洁验证的目的是证明所采用的清洁方法确能避免产品的交叉污染,微生物污染以及清洁后残 留的污染,使之达到可接受限度标准。 5.2 清洁验证的步骤 5.2.1 列出待进行清洁验证的设备所生产的一组产品。 5.2.2 选择参照产品。在所生产的一组产品中,选择最难清洁(即溶解度最小)的产品作参照产品。 相对于辅料而言,活性成分的残留物对下批产品的质量,疗效和安全性有更大的

5.2.3 选择设备最难清洗部位和取样点。凡是死角、清洁剂不易接触的部位——如带密封垫圈的管道连接处,压力、流速迅速变化的部位如有歧管或岔管处,管径由小变大处,容易吸附残留物的部位如内表面不光滑处等,均应视为最难清洗部位。取样点应包括各类最难清洗部位。 5.2.4 选择最不利清洗条件的参数 5.2.4.1 一组产品中最小NOEL=活性成分最小LAD/40(μg/60kg 体重) 其中:NOEL~活性成分的无显著影响值; LAD~每60kg 体重最小有效剂量; 40(即4×10) ~总体安全系数。 5.2.4.2 一组产品中最大口服日剂量(ml/g 或mg/日)。 5.2.4.3 一组产品中最小批量(mg 或ml)。 5.2.4.4 棉签取样面积(25cm2/每个棉签)。 5.2.4.5 设备内表面积(或与物料直接接触的总面积) (cm2)。 5.2.4.6 取样有效性(一般取50%,即假定棉签所取样品有50%的量被洗脱出来)。 5.2.4.7 冲洗溶剂的体积(ml)。 5.2.5 化学验证及可接受标准限度。清洗效果的最终评价根据是产品活性成分即主药及洗涤剂的残留量、微生物限度。 5.2.5.1 企业界普遍接受的限度标准基于以下原则: (1)生物活性限度:任何产品不能受到前一品种带来的超过其0.001 的日剂量的污染。 (2)分析方法客观能达到的能力:污染不能超过10PPm。 (3)微生物限度:视取样方法不同而异。棉签法取样可接受标准≤50CFU/棉签,最终冲洗水取样可接受标准≤25CFU/ml。 (4)以目检为依据的限度:不得有可见的残留物,假定为4μg/cm2(100μ g/4in2),且不得有残留气味。 5.2.5.2 所选择的参照产品生产结束后,按规定的清洁程序清洗设备,目检无可

设备清洁验证指南

第四节设备的清洁验证 关于清洁验证的原理及方法将在第三篇第二章详细介绍,制剂生产验证各章亦对相应设备的清洗验证要点进行介绍,可以参阅这些章节的内容。 考虑到制药设备验证的完整性,应包括设备的确认,变动控制程序、仪器仪表的校准和清洗验证。在此对设备的清洁验证从方法上作简单介绍。 设备清洗有自动清洗和人工清洗两种方法,或者两种方法的结合。 所谓清洗是从工艺设备或贮存设备中清除污染物的工艺过程,以保证设备能够安全地进行下一步的产品生产,它包括清洗、消毒和贮存。 设备清洁验证的目的是通过测试证明该设备的自动清洗程序(CIP)或人工清洗程 序能够清除设备部件上的活性药物残留物,并达到可接受的合格标准,并证明此清洁程序具有稳定性和重演性。 一、设备清洁验证中常用的术语 ①人体接触剂量限度(SEL,Subject E×posure Limit)。指一个没有药理学和毒理 学经验的人可以接触的某一药物的暴露剂量。 ②允许残留浓度(ARL,Allowable Residual Limit).指某一设备经清洗后,其表面残留的药物(或清洁剂)的最大允许量。 ③活性成分(API,Active Pharmaceutical lngredient;或ADS,Active Drug Substance):指在某一药物中代表效用的物质。这种物质在制造、工艺或包装过程中就变成了一种活性成分或者药物的最终成型形式。活性成分在疾病诊断、治疗、缓解、处理或预防方面提供药理上的活力或其他直接的作用,以致影响人体或动物的组织和功能。 API 在工艺制造过程中产生,如:①化学合成;②发酵;③重组DNA 或其他 生物工艺;④从自然资源上分离或取得;⑤ 其他工艺的任何组合等。对设备清洁验证来说,API 包括中间体及成品。 一般来说,SEL、ARL 的允许值应从药物安全评价部门获取。 二、验证设计 在验证取样测试时,若发现洗过的设备明显不干净,应立即停止验证,有明显的残留物存在表明现有的清洁程序是不合适的,因此必须在验证开始前重新评价清洁程序。从某种意义上来说,清洁验证就是对清洗标准操作规程的验证。 清洁验证主要是通过擦拭取样法和冲洗取样法对活性成分APl 进行测试。另外可根据日常使用的需要,增加一些其他项目的测试,如清洁剂、酸液、溶剂、消毒剂等残留量的测试。 大部分企业在设备清洗中使用的清洁剂是水(包括饮用水、纯化水和注射用水),原因之 一就是使用化学清洁剂要作清洁剂残留量的测试,从而增加清洗的难度。 制造部门在设备清洁程序中任何关于清洁剂、溶剂、添加剂的改变必须填写变动控制表, 得到批准后执行。并非所有的设备清洁验证需做活性成分APl 的测试。根据APl 是否在特殊的清洁剂或溶剂中溶解而使设备难以清洗的程度来对APl 的浓度作 出评价o APl 允许浓度可根据公式来计 算,如果人体接触剂量限度SEL 太低无法达到时,可用替代基质来覆盖所有的 产品。 (一)验证次数

洁净区离心机清洁验证方案

洁净区离心机 (咪喹莫特用)清洁验证方案天方药业有限公司

目录 一、目的 (1) 二、适用范围 (1) 三、职责 (1) 四、内容 (1) 1、概述 (1) 2、风险评估结果 (1) 3、参考资料 (2) 4、验证小组成员 (2) 5、验证前资料检查 (3) 6、验证原理 (4) 7、清洁方法及清洁产品 (4) 8、接受标准限度 (4) 9、取样部位的确定 (5) 10、取样方法及回收率测定 (5) 11、检验方法 (7) 12、清洁验证结果 (7) 13、清洁有效期的验证 (8) 14、偏差分析与整改 (9) 15、结果分析及评价: (9) 16、再验证: (9) 17、相关文件: (9) 18、相关记录: (9) 19、文件发放范围: (9) 20、附件: (9)

洁净区离心机 (咪喹莫特用)清洁验证方案 一、目的 建立《洁净区离心机(咪喹莫特用)清洁验证方案》,确认用于咪喹莫特产品离心甩滤时,按《离心机(34)清洁标准操作规程》清洗后,设备上的的残留物不超过规定的清洁限度要求,不会对将生产的产品造成交叉污染,证明《离心机(34)清洁标准操作规程》的有效性,保证药品质量。 二、适用范围 适用于《离心机(34)的清洁标准操作规程》的验证。 三、职责 1、验证小组成员负责《洁净区离心机(咪喹莫特用)清洁验证方案》的起草与实施。 2、质量管理部负责验证方案的审核与验证过程的监督。 四、内容 1、概述 合成车间洁净区离心机(34)是咪喹莫特离心甩滤所用设备,在药品生产中主要通过高速旋转使结晶液固液分离。其规格型号为PSL-1000。本次验证对《离心机(34)清洁标准操作规程》的可行性进行确认,评价在整个设备内表面(或与物料所接触部位)的潜在残留量和微生物污染情况,以保证药品的生产是在符合GMP要求的情况下生产的。使用该设备生产产品时没有来自上批产品及清洗过程所带来污染的风险,从而制造出安全、符合质量标准的原料药。 2、风险评估结果 清洁验证实施前,对影响清洁验证效果的风险因素进行评估,评估结果如下: 低风险点:人员因素中人员培训不到位及身体健康状况不能满足卫生要求,设备因素中设备材质及维护、清洁剂的清洗设计参数不合理,原辅料因素中清洁剂残留量超标,环境因素中环境洁净度超标造成微生物污染、设备使用后清洁之前污染情况过于严重导致无法使用。 中风险点:人员因素中人员清洁操作失误、人员取样位置不具有代表性,原辅料

某制药厂药品生产清洁验证规程

清洁验证规程 1适用范围 本标准适用于公司药品生产中所有与产品接触的设备、容器具清洗效果的验证。包括化学和微生物两项指标。 2清洁验证的目的 通过对制定的清洁SOP进行验证,考察清洁过程是否能始终如一地符合预定标准,降低交叉污染的风险。 3职责 生产技术部:负责清洁验证方案的起草及验证的实施。 质量部QC:负责按计划完成清洁验证中的相关检验任务,确保检验结论正确可靠。 QA验证管理员:负责验证工作的管理,协助清洁验证方案的起草,组织协调验证工作,并总结验证结果,起草验证报告。 质量部经理:负责清洁验证方案及报告的审核。 质量总监:负责清洁验证方案及报告的批准。 4内容 4.1清洁验证小组成员 生产技术部技术人员、QC主管、QC检验员、设备管理员、QA验证管理员。

4.2清洁验证范围的确定 所有与产品直接接触的生产设备、容器、工具。 4.3清洁验证前应明确: 4.3.1制造产品的类型和数目。 4.3.2产品处方/材料的特性。 4.3.3设备的特性。 4.3.4设备在生产过程中的作用。 4.3.5评价清洗过程的潜在问题。 4.4清洁验证的前提条件 4.4.1检查是否起草清洁SOP,清洁SOP应包括以下内容:4.4.1.1 SOP名称 4.4.1.2 SOP适用范围 4.4.1.3职责(本SOP涉及的责任部门或责任人) 4.4.1.4 SOP的操作步骤或程序 4.4.1.5清洁的范围或对象 4.4.1.6清洁实施的条件及频次 4.4.1.7进行清洁的地点 4.4.1.8清洁用的设备及设施 4.4.1.9清洁所用的清洁剂及其配制方法 4.4.1.10清洁方法及清洁用水 4.4.1.11清洁设备及器具的干燥与存放 4.4.1.12消毒剂及其配制 4.4.1.13消毒频次及方法 4.4.1.14清洁(及消毒)效果的评价 4.4.2清洁SOP的执行检查 4.4.2.1对照SOP检查是否有效执行。 4.4.2.2保证对所有关键步骤进行监控。 4.4.2.3通过不同操作人员进行对照确认。 4.4.2.4修订SOP并培训所有操作人员。 4.5清洁验证步骤

原料药清洁验证方案

原料药清洁验证方案 目的: 1 生产过程中,由于存在产品的残留,容易对下次生产的产品造成污染,影响产品质量。这种污染主要来自于对设备清洁不彻底,极易造成微量污染。因此需要在连续生产一段时间后及换品种时,制定切实可行的设备清洁操作程序并按该程序进行清洁,设备上的残留物(可见的与不可见的,包括前一批次或前一品种的残留物及清洗过程中的残留溶剂)达到了规定的清洁限度要求,不会对将生产的产品造成交叉污染,以保证产品的质量。 2 为再验证提供数据资料。 范围: 责任: 工程设备部负责验证过程中设备的正常运行,对设备和设备系统的取样和操作提供帮助。人力资源部负责对验证相关人员组织培训。生技部负责指派生产人员按对应设备相应的设备清洁操作规程,对设备进行清洁,确保清洁操作满足规范要求,为验证操作及取样提供帮助。质量部负责组织起草验证方案并组织相关部门、人员实施验证。 内容: 1、验证实施小组成员

部门姓名备注 2、验证计划 2.1生产过程中,待生产完后,设备中残留的物料为,残留的物料有可能对下批产品产生影响。因此,在生产完以后按清洁操作规程对设备进行大清洁,清洁后组织实施验证,以确保清洁规程能确实有效的对釜内残留的物料进行清除。 2.2验证时间:与生产时同步进行,记录连续三次大清洁检测结果 3、验证内容: 验证所需文件3.1. 原料药清洁验证方案

原料药清洁验证方案

振动筛:

2,按500g残留产品平均分配到各个设备表面,其中物料接触设备的总面积为98m 残留限量为: a.擦拭测试:擦拭面积以10㎝×10㎝的区域计 500g×1000 2×10%(保险系数)×―――――――――×100㎝70%(取样回收=残留限量A2×98m10000 率)2 ㎝/100=3.57㎎2/25ml=0.14mg/ml ㎝/100残留限度定为:3.57㎎对棉签溶出液照紫外可见分光光度法,在257nm 波长处检测吸光度(磺胺甲恶处有最大吸收),按吸光度计算出残留浓度。257nm 的氢氧化钠溶液中在3%唑在. 原料药清洁验证方案 b.清洗液测试:清洁结束后,向脱色釜中加入500L的溶液,搅拌0.5小时,压滤至中和釜、结晶釜通过离心机,转至干燥机、振动筛、周转桶,在各设备、器具的出口处收集洗淋溶液,检测限度,其残留限量为:500g×1000 浓度限量B=――――――---―×10%(保险系数)=0.10㎎/ml 500L×1000 对于清洗液取样,照紫外可见分光光度法,在257nm波长处检测吸光度,按吸光度计算残留浓度。 3.2.2.2 微生物残留可接受标准:清洗的微生物验证和清洗的化学验证同步进行,菌落数≤50个/棉签 3.2.2.3 按相应设备清洁操作规程进行清洁后,对设备表面残留物擦拭取样,然后样品进行残留物(紫外分光光度法)检测或微生物限度检查,将所得结果与可接受限度比较,若不高于可接受限度,则可证实清洁程序的有效性。 3.3 清洗剂的选择 清洁规程中规定使用的清洁溶剂为纯化水,但从取样回收率考虑,在水中的溶解度很低,取样回收率达不到要求,而易溶于碱性溶液中,且精制过程中使用了碱性溶液,故清洁验证中清洁后取样用溶剂选为3%的氢氧化钠溶液。精制过程中所用的材质为不锈钢。因此,擦拭法回收率验证使用的模具为10 cm×10cm的不锈钢片。 3.4 清洁程序

药厂提取工序清洁验证方案

百度文库- 让每个人平等地提升自我 目录 1.概述 2.验证目的 3.适用范围 4.职责 5.验证内容 相关文件 清洁方法描述 验证方法 异常情况及偏差处理 验证结论与评定 6.附件 表1 清洁记录 表2 取样记录 表3 实验记录 表4 回收率实验记录 表5 异常情况及偏差处理记录

1.概述 本公司生产的产品以片剂、颗粒剂为主,属于非无菌固体口服制剂,提取工艺基本相同,均为水提取,仅投料、加水量有区别,清洁方式相同,对提取工序的设备(提取罐1套,静止罐2套)进行清洁验证。 2. 验证目的 通过对提取操作的验证,确认提取各岗位的清洁规程适用性,证明在生产过程中按清洁规程可以有效的控制微生物的污染,可以控制不同批次的交叉污染,确保产品的质量稳定性和均一性。 验证过程应严格按照本方案规定的内容进行,若因特殊原因需变更时,应填写验证方案变更申请及批准书,报验证领导小组批准。 3.适用范围 本验证方案适用于XXXXXXXXXX有限公司提取工序的清洁验证。 4. 职责 验证小组成员、姓名、职责如下 部门姓名职责签名日期 生产部组织生产、清洁、验证操作 质量部现场监督及取样 质量部化验检测 生产部方案及报告起草、培训 验证领导小组成员、姓名、职责如下 部门姓名职责签名日期 生产部负责清洁过程的管理和评价 质量部负责取样和检验的管理和评价 总经理负责验证的最终评价

5. 验证内容 相关文件 文件名称文件编号存放地点 1 提取岗位标准操作规程LR-JS-08 办公室 2 DT-2000型多功能提取罐清洁规程LR-SC-45 办公室 清洁方法描述 5.2.1 打开出渣门. 5.2.2 用饮用水清洁提取设备,通过高压水枪冲洗投料仓及出渣门. 5.2.3 将提取储液罐进液阀关闭,打开输液管与排污管的连接阀,开启循环泵的饮用水阀门,用清水清洗输液管路。 5.2.4清洗过程中,阀门连续打开关闭10次,清洗阀门;各支管、排污管阀门打开1分钟,进行清洗。 5.2.5 用清洁专用抹布蘸饮用水擦拭设备、管道外壁污痕. 5.2.6 填写清洁记录,记录见表1 验证方法 5.3.1 验证方法选择 选用棉签擦拭和饮用水冲洗,棉签擦拭法为清洁验证的常用方法,该方法可靠性强,简单易行。饮用水冲洗和实际清洁操作相同,有代表性。将两种方法相结合可以真实有效的反应清洁实际情况。 5.3.2 验证关键部位 提取罐内壁,管路内径,过滤器内壁。 5.3.3 最难清洁部位的确定: 1)A部位:提取罐内壁底部均为筛网,表面最粗糙,为不易清洗的地方。 2)B部位:管路选择位置较低的循环阀处,由于该处液位较低同时有循环阀,为不易清洁的部位。 3)C部位:过滤器内壁底部,因为此处液位最低,同时所有药液均从此通过。4)D部位:贮液罐底部截门,因药液在此处停留时间较长,并且该位置液位最低。

APIC颁布原料药工厂清洁验证指南

APIC颁布原料药工厂清洁验证指南 An APIC multinational working group has compiled a new guidance on cleaning validation with the title "APIC Guidance on Aspects of Cleaning Validation in Active Pharmaceutical Ingredients Plants". Publication date is May 2014 and the document can be downloaded from the APIC website. The following is a summary description of the document. The document contains 55 pages and is subdivided into 13 chapters. APIC多国工作组汇编了新的清洁验证指南,题为“APIC原料药工厂清洁验证指南面面观”。颁布日期为2014年5月,文件可以从APIC官网下载。以下是该文件的摘要。文件包括55页,分为13章。 Foreword 前言 Objective 目的 Scope 范围 Acceptance Criteria 可接受标准 Levels of Cleaning 清洁水平 Control of Cleaning Process 清洁工艺控制 Bracketing and Worst Case Rating 括号法和最差情况分类法 Determination of the Amount of Residue 残留量的检测 Cleaning Validation Protocol 清洁验证方案 Validation Questions 验证问题 References 参考文献 Glossary 术语 Copyright and Disclaimer 版权和声明 The topic cleaning validation gained new importance in the EU with the publication of the EMA Guideline "Guideline on setting health based exposure limits for use in risk identification in the manufacture of different medicinal products in shared facilities" and with the chapter Cleaning Validation in the draft of the revision of Annex 15. The foreword refers to the integration of cleaning validation within a quality system supported by quality risk management processes in order to protect the patients. According to the authors the document is aligned with ISPE Risk-MaPP

清洁验证要求

(1) 清洁验证的一般要求 清洁验证是通过文件证明清洁程序有效性的活动,它的目的是确保产品不会受到来自于同一设备上生产的其他产品的残留物、清洁剂以及微生物污染。 为了证明清洁程序的有效性,在清洁验证中应至少执行连续三个成功的清洁循环。 对于专用设备,清洁验证可以不必对活性成分进行考察,但必须考虑清洁剂残留以及潜在的微生物污染等因素,对于一些特殊的产品,还应考査降解产物。 对于没有与药物成分接触的设备(如加工辅料用的流化床或包衣片所使用的包装设备),清洁验证可以不必对活性成分进行考察,但必须考虑清洁剂残留及微生物污染等因素。 清洁验证中需对下列放置时间进行考察,进而确定常规生产中设备的放置时间: ? 设备最后一次使用与清洁之间的最大时间间隔(“待清洁放置时间”); ? 设备清洁后至下一次使用的最大时间间隔(“清洁后放置时间”)。 (2) 清洁验证的前提条件 进行清洁验证的前提条件是: ? 清洁程序已批准,其中包括关键清洁程序的参数范围; ? 完成风险评估(对于关键操作、设备、物料包括活性成分、中间体、试剂、辅 料、清洁剂、以及其他可能影响到清洁效果的参数); ? 分析方法经过验证; ? 取样方法已经批准,其中包括取样规程和取样点; ? 验证方案已经批准,其中包括接受标准(根据不同设备制定)。 (3) 测试项目 清洁验证中涉及的测试项目应根据产品的类型通过风险分析而定,通常需考虑以下 内容: 參目测检查; ? 活性成分残留; ? 清洁剂残留; ? 微生物污染; ? 难清洁并可能对后续产品造成不良影响的辅料(如色素或香料)。 ( 4 ) 取样 清洁验证中应用的取样方法应详细规定并且经过批准,选择取样方法时应考虑残留物和生产设备的特性。 3 产品质量实现的要素 化学成分残留取样:

QA-SOP-031-01 清洁验证管理规程 - 副本

公司班组安全活动管理制度 目录 1定义 (2) 2 清洁验证流程图 (2) 3 设备的评估 (3) 4 验证项目的确定 (4) 5 清洁参照物质的选择 (4) 6 取样方法和取样点的确认 (4) 7 设备内表面积的确定 (5) 8 产品残留限度的确定 (5) 9 检验方法及检验方法的验证 (5) 10 取样方法验证 (6) 11 设备清洁有效期 (6) 12 异常情况处理及注意事项 (6) 13 再验证 (6) 14 文件变更历史 (6) 页脚内容

公司班组安全活动管理制度 【目的】 规范清洁验证程序,指导清洁验证的操作方法。防止药品的交叉污染,通过验证确定上批产品残留在设备中的物质减少到不会影响下批产品质量和安全性的程度。【范围】 本规程适用于在公司发生的所有清洁验证行为。本规程描述了清洁验证的具体方法,包括清洁验证流程、设备的评估、取样点的选择、设备内表面积的计算、参照物质的选择、取样方法、标准要求、清洁剂的残留、检验方法的验证、取样回收率试验、设备清洁有效期等。 【制定依据】 企业标准及相关法律法规。 【职责】 干燥包装车间负责制定本规程,各相关部门执行、检查。 【内容】 1定义 清洁:指设备中各种残留物(包括微生物及其代谢)的总量低至不影响下批产品的规定的质量和安全性的状态。 在线清洁(CIP):指系统或较大型的设备在原安装位置不作拆卸及移动的条件下的清洁工作。 最终淋洗水:指设备清洁程序最后一步淋洗即将结束时的水样,也指在淋洗完成后在设备中加入一定量的工艺用水,用量需小于生产批量,使其在系统内循环后的水样。 2 清洁验证流程 页脚内容

公司班组安全活动管理制度 3 设备的评估 设备的评估由质量部负责进行。评估内容在验证总计划中体现,根据设备用途的不同,设备评估用来确定哪些设备是多个活性成分共同接触的,即公用设备;哪些设备是和某个产品单独接触的,即专用设备。 设备评估是确定哪些设备包括在清洁验证中,哪些设备不包括在清洁验证中,按 页脚内容

中英对照-APIC 原料药厂清洁验证指南:7.0 分组法(括号法)

APIC 201405原料药厂清洁验证指南:7.0 分组法(括号法)和最差情况分级(中英文) 2014-07-15julia翻译蒲公英 7.0 Bracketing and Worst Case Rating 分组法(括号法)和最差情况分级 7.1 Introduction 介绍 The cleaning processes of multiple product use equipment in API facilities are subject to requirements for cleaning validation. The validation effort could be huge. In order to minimize the amount of validation required, a worst case approach for the validation can be used. 原料药工厂中的多产品设备清洁要求进行清洁验证。清洁工作量会比较大。为了减少验证的工作量,可以采用最差情形方法进行验证。 By means of a bracketing procedure the substances are grouped. 采用分组法时,物质按类进行分组。 A worst case rating procedure is used to select the worst case in each group. 然后在每组中采用最差情形分级法选择各组中最差的情况。 Validation of the worst case situation takes place. However, it is of utmost importance that a documented scientific rational for the chosen worst cases exists. 对最差情形进行验证。至关重要的是,选择最差情形的科学合理性要进行记录。This chapter gives an overview of the suggested work to be carried out, the acceptance criteria and the methodology for evaluation of the data. It should be emphasized that this is only an example to give guidance. The equipment, the substances produced and the procedures in place may vary; and this results in other solutions than those given in this example.

铝塑泡罩包装机清洁验证方案2014

DPP-250C平板式铝塑泡罩包装机 清洁验证方案 编号:SVP-QJ-1308-01 制订人:日期: 审核人:日期: 日期: 日期: 批准人:日期: 设备名称:平板式铝塑泡罩包装机 型号:DPP-250C 制造厂商:**** 出厂日期:2014年10月 使用部门:固体制剂车间 安装位置:铝塑包装间 设备编号:S-GT-011

目录 1. 概述 (4) 1.1 验证目的 (4) 1.2 设备简介 (4) 1.3 验证描述 (4) 1.4 验证小组组成及分工 (4) 1.5 验证培训 (4) 1.6 验证时间安排 (4) 2. 验证内容 (5) 2.1 主要检验仪器确认 (5) 2.2 关键部位、参照产品、残留限度 (5) 2.3 清洁验证 (6) 3. 再验证周期 (8) 4. 确认评价及建议 (8) 5. 最终审核意见 (8) 6. 附验证检查记录 (8)

验证项目小组会签单 职责姓名部门时间项目组长 QA QC 计量管理员 操作人员 操作人员 操作人员

1 概述: 1.1 验证目的:为了防止污染和交叉污染,确保清洁完全彻底,采用物理外观检查、活性成分残留检查、清洁剂残留、微生物限度检查,对清洁效果进行综合评价,确认清洁、消毒程序能符合生产工艺要求,没有来自上批产品及清洗过程所带来的污染风险。 1.2 设备简介:平板式铝塑泡罩包装机,用于片剂、胶囊剂等固体制剂的泡罩式密封包装生产。由机械传动装置,包材传送系统,电加热系统,热合、冲裁机构,控制系统及药品输送系统组成。PVC/PVDC经包材传送系统进入热合机构,药品通过输送系统进入泡罩后热压成型,经冲裁机构分成所需板块。 1.3 验证描述:目前该设备主要用于扎来普隆片、星瑙灵片的内包装。确认生产结束后至清洁进行时的放置时间DHT;按《平板式铝塑泡罩包装机清洁、消毒操作规程》进行清洁、消毒。对设备最难清洗部位进行擦拭取样、分析、评价,确认所制订的清洁消毒操作规程能满足工艺要求;确认清洁过程对产品生产无污染。若不能满足,则应及时进行方法的调整,同时提出修正方案,并重新验证。清洁消毒后, 48,72,96小时分别取样检测微生物,进行清洁有效期验证。若出现偏差,进行必要的偏差处理。清洗效果验证须连续进行3批。 1.4 验证小组组成及分工: 部门责任人职责 固体制剂车间车间主任验证方案的起草、实施,验证数据的收集,验证报告的起草 生产技术部负责人验证方案的审核,验证工作的协调 质量管理部负责人验证方案的审核,验证过程的监督,样品的采集、分析,验证报告的审核1.5 验证培训: 培训内容日期签名 平板式铝塑泡罩包装机清洁、消毒标准操作规程 清洁工具的使用和清洁消毒操作规程 消毒液配制、贮存、发放操作规程 平板式铝塑泡罩包装机清洁验证方案 设备清洁擦拭取样回收率验证方案 1.6 验证时间安排: 2014年··月20日~··月··日进行方案培训,进行技术准备。 2014年··月··日~··月··日进行方案实施。

固体制剂车间清洁验证方案

文件编号:TS-VD-QJ(P)-003-00 生效日期: 页码:共页 固体制剂车间口服固体制剂生产线 清洁验证方案 ****药业有限公司

确认方案起草 部门起草人职务签字日期质量部 固体制剂车间 生产技术部 确认方案审核 部门姓名职务签字日期质量部 生产副总 确认方案批准 批准人职务签字日期

目录 1. 目的-------------------------------------------------------------------- 2.概述-------------------------------------------------------------------- 3. 产品选择及风险分析------------------------------------------------------ 4. 确认小组---------------------------------------------------------------- 5. 确认用仪器及仪表的校准-------------------------------------------------- 6. 相关文件和人员培训的确认------------------------------------------------ 6.1 验证所需文件的确认----------------------------------------------------- 6.2 人员培训的确认--------------------------------------------------------- 7. 验证内容---------------------------------------------------------------- 8. 偏差分析及处理---------------------------------------------------------- 9. 结果与评价--------------------------------------------------------------

相关文档
最新文档