便携式露点仪说明书

便携式露点仪说明书
便携式露点仪说明书

CERMAX IS

Issue 11, March 2003 Manual No.97046 43Pages

1.1 (4)

1.2 (5)

1.3 ATEX (5)

2.CERMAX IS (7)

2.1 (7)

2.2 (7)

2.2.1 (7)

2.2.2 (7)

2.3 (8)

2.4 (8)

2.4.1 (8)

2.4.2 (9)

3. CERMAX IS (10)

3.1 (10)

3.2 (11)

3.3 (11)

3.3.1 (12)

3.4 (12)

3.4.1 (12)

3.4.2 DEW POINT( ) (13)

3.4.3 PPM(W)( ) ( ) (14)

3.4.4 PPM(V) 1b/mmscf g/m3 %RH (14)

3.5 (14)

3.5.1 (15)

3.5.2 (15)

3.5.3 (15)

3.5.4 (16)

3.5.5 (16)

3.5.6 (17)

3.5.7 (18)

3.6 (19)

3.6.1 (Test No.) (20)

3.6.2 (20)

3.6.3 (20)

3.6.4 (21)

3.6.5 (21)

3.6.6 (21)

3.6.7 (21)

3.6.8 (22)

3.6.9 (22)

3.6.10 (23)

3.6.11 (23)

3.6.12 (23)

3.7 (24)

3.7.1 (25)

3.7.2 (26)

3.8 (27)

3.9 (29)

4.1 (31)

4.2 (31)

4.3 (32)

4.4 (32)

5. (33)

5.1 (33)

5.2 CERMAX IS (33)

5.2.1 (34)

5.2.2 (34)

5.3 (35)

6. (38)

1 (39)

2 MICHELL (40)

3 CERMAX IS (42)

1.

CERMAX IS MICHELL LCD -100 20 -120o C~+30o C

CERMAX IS CERMAX IS CERMAX IS CERMAX IS DISPLAY 3.6

CERMAX IS CERMAX IS ON ( 4.3 )

1.1

(NPL) UKAS -75 ~+20oC( 0179) (NIST)

MICHELL MICHELL MICHELL 5.0

1.2

BS EN ISO 9001:1994 Baseefa (2001)

B.S.I.&Baseefa(2001)

1.3 ATEX

CERMAX IS ATEX (94/9/EC) Baseefa (2001) Ltd (Notified body 1180) BS EN 50 014T bs en 50 020 C.E.N.E.L.E.C. Ex II 1G EEx ia IIC 155o C (T3) Baseefa 03ATEX0090X

CERMAX IS ATEX (94/9/EC) ATEX worker protection Directive (1999/92/EC)

( )

(Flat Battery)

CERMAX IS

(Logging memory full or incorrect instrument setup.) CERMAX IS CERMAX IS

/ (Sensor over/under range or inaccurate sensor measurement)

1)

2)

3)

4.

2.CERMAX IS

2.1

CERMAX IS

2.2

CERMAX IS

2.2.1

CERMAX IS 4.2

CERMAX IS SWAGELOK 1/8” 0.5~5Nl/min 30MPa(300barg) 90o

2.2.2

on/off (Default) (Previous)

3. CERMAX IS

2.3

CERMAX IS field mode laboratory mode 3.7 3.7.1

0 0

15 2 2 -80

CERMAX IS 2

LCD

2.4

CERMAX IS

2.4.1

CERMAX IS 4

CERMAX IS

CERMAX IS

CERMAX IS CERMAX IS

2.4.2

CERMAX IS RS232 3.6 3.7 3 CERMAX IS 9 D

3. CERMAX IS

3.1

10 USER SETUP DEFAULT( ) PREVIOUS( )

DEW POINT,OVER ICE

NONE

o C o F

psig

DEFAULT/PREVIOUS

CERMAX IS

SENSOR ID C123 C45 CALIBRATED 14:04:99

SOFTWARE VERSION B1.80.00 I.S.

COPYRIGHT MICHELL INSTRUMENTS LTD.

1a

USER SETUP: DEFAULT PREVIOUS

BATTERY CHECK OK

1b

3.2

(MAIN DISPLAY) (AUXILIARY DISPLAY)

2

Stable DP @ Pressure 10.2oC

10.2 °C DP

WARNING - LOW BATTERY

3

3.7

DATE 14:04:97 TIME 14:25

NO LOGGED DATA AVAILABLE

4

3.3

3

CERMAX IS

Main Display Main option

3.3.1

MENU

3.4

.

DP PPM(V)

PPM(W)

g/m 3

Ib/mmscf %RH 3.4.1

MAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)

5a

MAIN DISPLAY AUX DISPLAY LOGGING

g/m 3

lb/mmscf %RH

MAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)

6

3.4.2 DEW POINT( )

o C o F K

MAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W)

7 o F

0o C OVER WATER

0o C OVER WATER

MAIN DISPLAY AUX DISPLAY LOGGING DP °C °F K OVER WATER PPM(V) PPM(W) 8

3.4.3 PPM(W)( ) ( )

PPM(W)

MAIN DISPLAY AUX DISPLAY LOGGING DP PPM(V)

PPM(W) N 2 AIR CO 2 H 2 SF 6

9 PPM(W) 3.4.4 PPM(V) 1b/mmscf g/m 3 %RH PPM(V) 1b/mmscf g/m 3 %rh

3.5

%rh

%rh

Auxiliary Options

Main Option None

Set Temp Set Press Sensor

Display DP

x

PPM(V) x

PPM(W) x

g/m 3

x x x lb/mmscf x x

x %RH

x x

x

None. ( ) NONE( ) 21o

C

SET TEMP CERMAX IS %rh

SET PRESS ( ) Set Press

SENSOR. DISPLAY.

AUX DISPLAY LOGGING MAIN DISPLAY None

Set Temp Set Press

10a

AUX DISPLAY LOGGING MAIN DISPLAY Set Press Sensor Display

10b ( ) 3.5.1

AUX DISPLAY LOGGING MAIN DISPLAY None

Set Temp °C °F K Set Set Press

11 3.5.2

%rh (Set temp)

(Set Temp) (Set)

AUX DISPLAY LOGGING MAIN DISPLAY

None

Set Temp °C °F K Set Set Press

12 F 3.5.3

(Set)

Maximum allowable values Minimum allowable values +200°C -100°C +392°F -148°F 473K +173K

AUX DISPLAY LOGGING MAIN DISPLAY None

Set Temp

°C °F K Set -25 Set Press

13 -25 3.5.4

%rh Set Press PSIG BARG bar

kPa kPa kPa

(Set Press) (Set)

AUX DISPLAY LOGGING MAIN DISPLAY None

Set Temp

Set Press PSIG BARG kPa Set 1000

14 BARG 3.5.5

Maximum

allowable values Minimum allowable values 5880 PSIG 0 PSIG 400 BARG 0 BARG 40,000 kPa 50 kPa

AUX DISPLAY LOGGING MAIN DISPLAY None

Set Temp

Set Press PSIG BARG kPa Set 38

17 38

1b/mmscf g/m 3 CERMAX IS 1b/mmscf CERMAX IS 1958 kPa bar

0 50psig 10 psig 75~300 psig 25 psig 350 500 psig 50 psig 600 1000 psig 100 psig 1200 1500 psig

300 psig

CEREMAX 13psig bar kPa 10psig CERMAX IS 540psig 500psig 3.5.6

( 3.5.4) AUXILIARY DISPLAY( ) (Sensor)

%RH

g/m 3 lb/mmscf AT PRESS

AUX DISPLAY LOGGING MAIN DISPLAY Set Temp Set Press

Sensor At Press At Atm

16 3.5.7

(Auxiliary Display)

(Sensor)

%RH

g/m 3 lb/mmscf PRESS

AUX DISPLAY LOGGING MAIN DISPLAY Set Press Sensor

Display Press DP

17

DP @ Pressure 36.5°C

10.2

°C DP

FIELD MODE CAL DUE 04:98

18

Set Pressure 550 PSIG 10.2

°C DP

FIELD MODE CAL DUE 04:98

23

3.6

CERMAX IS 1000 10000 PC 3.7

(LOGGING)

Test No. Interval Samples

Start/Stop

LOGGING MAIN DISPLAY AUX DISPLAY Test No. Text

Interval.

20a

LOGGING MAIN DISPLAY AUX DISPLAY

Interval

Samples

Start/Stop

20b ( )

3.6.1 (Test No.)

0 TEST NO 0 Test No.

3.6.2

15 /-

TEXT3

LOGGING MAIN DISPLAY AUX DISPLAY

Test No.

Text QUALITY TESTS 3THIS IS MY TEST

Interval.

21

3.6.3

LOGGING MAIN DISPLAY AUX DISPLAY

Test No.

Text

Interval 1 2 3 5 10 15 30 45 60 mins

22

便携式露点仪说明书

CERMAX IS Issue 11, March 2003 Manual No.97046 43Pages

1.1 (4) 1.2 (5) 1.3 ATEX (5) 2.CERMAX IS (7) 2.1 (7) 2.2 (7) 2.2.1 (7) 2.2.2 (7) 2.3 (8) 2.4 (8) 2.4.1 (8) 2.4.2 (9) 3. CERMAX IS (10) 3.1 (10) 3.2 (11) 3.3 (11) 3.3.1 (12) 3.4 (12) 3.4.1 (12) 3.4.2 DEW POINT( ) (13) 3.4.3 PPM(W)( ) ( ) (14) 3.4.4 PPM(V) 1b/mmscf g/m3 %RH (14) 3.5 (14) 3.5.1 (15) 3.5.2 (15) 3.5.3 (15) 3.5.4 (16) 3.5.5 (16) 3.5.6 (17) 3.5.7 (18) 3.6 (19) 3.6.1 (Test No.) (20) 3.6.2 (20) 3.6.3 (20) 3.6.4 (21) 3.6.5 (21) 3.6.6 (21) 3.6.7 (21) 3.6.8 (22) 3.6.9 (22) 3.6.10 (23) 3.6.11 (23) 3.6.12 (23) 3.7 (24) 3.7.1 (25) 3.7.2 (26) 3.8 (27) 3.9 (29)

4.1 (31) 4.2 (31) 4.3 (32) 4.4 (32) 5. (33) 5.1 (33) 5.2 CERMAX IS (33) 5.2.1 (34) 5.2.2 (34) 5.3 (35) 6. (38) 1 (39) 2 MICHELL (40) 3 CERMAX IS (42)

XP3110,3140,3160,3120气体检测仪说明书

宇宙式检测器系列 ■XP-3110 (可燃性气体检测器) 便携式气体检测器 ■XP-3140 (高浓度气体检测器) 使用说明书 ■XP-3160 ■ XP-3120 (高灵敏度气体检测器) 本使用说明书记载有左面所示4种机型的使用方法。 ●请妥善保管本使用说明书,以便随时取阅。 ●请认真阅读本使用说明书再加以使用。 新宇宙电机株式会社 NEW COSMOS ELECTRIC CO.,LTD. 规格文件编号XP-3000T

目录 包装内容物的说明 (1) 1.前言 (2) 防爆相关事项 (2) 符号图标的说明 (2) 安全使用说明 (3) 2.各部的名称与功能 (4) 3.使用方法 (7) 使用程序 (7) 气体报警 (10) 各种功能与设定方法 (11) 峰值保持的设定 (12) 报警蜂鸣器静音设定 (13) 对象气体的切换 (14) 记录执行 (15) 数据记录通信画面 (16) 时间设定 (17) 4.报错信息(故障报警) (18) 5.消耗品的更换方法 (19) 过滤片的更换 (19) 更换电池 (20) 充电电池(选购) (21) AC电源(选购)的使用方法 (22) 6.维护检查 (23) 日常检查 (23) 定期检查 (23) 主要更换部件 (23) 7.故障、原因与对策 (24) 8.保证书与登记卡 (25) 9.规格 (26) 10.检测原理 (27) 11.术语的说明 (28)

—包装内容物的说明— 包装箱内装有下述物品。使用前务请检查是否齐全。作业时要采取万全对策,万一产品出现破损和缺失,请致电销售店或本公司。我们将为您寄送。 ※电脑最低配置要求: ·OS:MS-Winddows?XP (其它版本下将无法运行) ·硬盘空间:剩余空间6M以上 ·CD-ROM驱动器:可读CD-R的CD-ROM驱动器(软件从CD-R安装) ·USB接口:Windows可使用的USB1.1标准以上,可连接连接器类型A。

COD在线检测仪使用说明书

COD在线检测仪使用说明书 目录 一、 JHC-Ш型CODcr在线检测仪使用说明书 (3) 1. 主要技术指标 (3) 2. 有机化合物的测定国标方法 (4) 3. 仪器结构简介 (5) 4. COD自动检测仪工作步骤 (6) 5. 各子系统功能工况祥解 (9) 6. 微机控制系统原理 (11) 7. 主菜单选择及功能 (12) 8. 仪器维护与保养 (13) 9. 仪器故障显示及处理 (14) 二、 COD 在线分析仪试剂配比 (15) 三、易损易耗件一览表 (16) 一、主要技术参数与特点 1.技术参数 测量范围(mg/L):30~950(扩展型1000~4000或4000~10000) 测量误差:≤±10% 重复误差:≤±5% 适用环境温度:5~40℃ 电源电压(v) :220±10% 功率(kw):1.5 主机类型:日本三菱公司原装PLC 显示方式:彩色触摸显示屏 打印机:16位微打(并行口) 数据远传接口:RS232,Modem 注:根据GB11914-89国家标准,检测COD在50mg/L以下的水样时,需要用低浓度标准溶液。其测量误差大于本指标。 2.技术特点: ⑴仪器测试原理、方法、步骤完全符合国家标准,检测数据准确可靠。 ⑵仪器主机采用三菱PLC、彩色触摸屏,图形画面活泼多彩,生动直观,全中文显示,一目了然,操作更方便。 ⑶仪器具有较强的远程通讯功能。通过电话线或无线电与远程终端联系。 ⑷仪器若发生故障,现场主机会自动拨通值班电话,向终端计算机报告故障情况。终端计算机可随时拨通现场电话与现场主机通讯,监控现场仪器的工作情况,调取现场主机一月内任意时间的检测数据结果。 ⑸仪器采用全气动移液、定量、加液结构,解决了强腐蚀性药剂对自控元器件的影响,使系统运行更可靠。 ⑹仪器集水样采集与COD检测于一体,回流消解采用独特的风冷加静止水套冷却方式,无需自来水水源,使现场应用更为方便。 ⑺由PLC控制的精密注射泵完成氧化还原滴定的数据计量,由光电信号准确测得滴定终点,

DRL600故障录波及测距装置技术说明书(国电南自)

国电南自 Q/SDNZ.J.51.02-2005 标准备案号:1213-2005-K DRL600 微机型电力系统故障录波及测距装置 技术说明书国电南京自动化股份有限公司

DRL600 微机型电力系统故障录波及测距装置 技术说明书 编写: 审核: 批准: V 6.0.00 国电南京自动化股份有限公司 2006年12月

为保证安全、正确、高效地使用装置,请务必阅读以下重要信息: (1)装置的安装调试应由专业人员进行; (2)装置上电使用前请仔细阅读说明书,应遵照国家和电力行业相关规程,并参照说明书对装 置进行操作、调整和测试,如有随机材料,相关部分以资料为准; (3)装置上电前,应明确连线与正确示图相一致; (4)装置应该可靠接地; (5)装置施加的额定操作电压应该与铭牌上标记的一致; (6)严禁无防护措施触摸电子器件,严禁带电插拔模件; (7)接触装置端子,要防止电触击; (8)如要拆装装置,必须保证断开所有地外部端子连接,或者切除所有输入激励量,否则,触 及装置内部的带电部分,将可能造成人身伤害; (9)对装置进行测试时,应使用可靠的测试仪; (10)请勿随意修改各配置文件,为了保证录波软件的正确性和完整性,在MMI模块内均备份了 该工程的数据配置文件和安装程序,配置文件如有修改,请立刻更新,便于在发生问题时能够及时恢复; (11)由于本装置的MMI模块是windows2000平台,为了保证装置能够安全的运行,请勿在MMI模 块内安装其它任何应用软件; (12)详细的使用维护说明请参见“使用说明书”。

本说明书适用于DRL600微机型电力系统故障录波及测距装置V6.0.00版本 产品说明书版本修改登记表 * 本说明书可能会被修改,请注意核对实际产品与说明书的版本是否相符 * 由于产品的升级,可能会存在与本说明书不一致的情况,恕不另行通知

HNWS型智能露点仪(SF6智能微水仪)说明书

HNWS型 智能型露点仪 产品说明书 武汉华能联创电气有限公司 单位地址:武汉市洪山区武南路12号网址:https://www.360docs.net/doc/0d7807752.html,

HNWS 智能型露点仪 第 1 页

HNWS 智能型露点仪 目录 敬告 (3) 一、技术特点及参数 (4) 1、技术特点 (4) 2、技术参数 (5) 二、仪器面板说明 (6) 1、前面板 (6) 2、后面板 (8) 3、液晶屏 (8) 三、测量 (9) 四、菜单操作 (10) 1、打印 (11) 2、保存数据 (11) 3、查看记录 (12) 4、删除记录 (12) 5、修改时间 (12) 五、注意事项 (13) 附录:(六氟化硫断路器含水量测量要求) (14) 第 2 页

HNWS 智能型露点仪 敬告 尊敬的HNWS型智能型露点仪用户: 如果您是第一次使用本产品,敬请注意以下事项: 1.仪器开机自动进入测量状态,测量开始,首先全部打开面 板上的流量阀,然后用仪器上的测量管道的针型阀调节流量。测量结束,则反之操作。 2.本设备内置大容量锂电池,充满电后可连续工作10小时以 上。 3.露点仪放置长时间不使用时,在测试管道和气室中会剩有 部分空气,因此在第一次测试时,其中的高湿气体会影响其测试速度,因为被测SF6气体达到饱和前需要先要将空气中的湿气带走。所以我们会发现当测试第二台SF6电气设备及以后再测量的速度就会很快(3-5分钟)。 4.打印数据时,建议插上AC220V电源,增加电池使用时间(打 印机选配)。 5.如遇高温天气需做测量,我们建议尽量将测量时间安排在 早晨温度较低时,因为较高的气温会影响测量的准确性。 参考标准:中华人民共和国电力行业标准 DL/T506-2007《六氟化硫电气设备中绝缘气体湿度测量方法》 6.对测量环境温度与湿度的要求 环境温度:5℃~35℃(尽可能在10℃~30℃间测量) 谢谢合作! 第 3 页

静电测试仪使用说明书

Hand-held static sensor locates and meas-ures static voltages, tests air ionizers.New from 3M,the 718 Static Sensor can help companies competing in the global high-tech marketplace prevent cost-ly losses due to electro static discharge (ESD) damage by playing a vital and valuable role in their own ESD control program. Easy to use,the hand-held 3M ?718 Static Sensor is designed to measure static voltages on objects and sur-faces arising from electrostatic charge buildups,and can help identify ESD trouble-spots — ensuring product relia-bility and customer satisfaction which translates into com-pany profits. As a bonus,when used in conjunction with the 3M TM Model 718A Air Ionizer Test Kit,the 718 can also be used to verify the operation of air ionizers.718 Static Sensor Features ? Small-size,lightweight,conductive plastic housing ? Membrane switches for Power,Range/Zero,and Hold functions. ? Digital,LCD (liquid-crystal) display is easy to read and updates quickly. ? Ranging system assists user in making quick and easy measurements ? Measurements accurate to 5% ? Output jack available for continuous measurements Convenient Size/Low Power Requirements The 718 is small enough to be carried in a pocket and weighs less than 5 oz. (142 g),including battery. The light-weight plastic housing is conductive,allowing a properly-grounded user to dissipate all electrostatic charges from the surface of the meter.Meter Functions The meter is equipped with three membrane switches which control different functions. The POWER switch turns the instrument on and off. The RANGE/ZERO button performs two functions; when pressed momentarily it switches between the two measurement ranges of 0-2,000 volts and 0-20,000 volts,and if held for longer than 3 seconds,it resets the voltage display to 0 volts. The HOLD button allows the user to freeze a measurement on the LCD for later review.Ranging System Included with the 3M 718 Static Sensor is a ranging system consisting of two light-emitting diodes (LEDs) which each emit a circular red light onto the surface being measured for static. When the two lights intersect and form a single focused light,the measurement distance is the prescribed 1 inch (2.54 cm). Accuracy The Model 718 Static Sensor is accurate to within ±5% of the displayed measurement,at a distance of one inch (2.54 cm) from the target. Accuracy will vary as the dis-tance between measured object and instrument changes from the one inch (2.54 cm) specification.Analog Output Jack The analog output jack located in the front of the unit pro-vides a convenient hook-up,via a 3/32 inch (2.5 mm)monophone jack,to a recorder/data acquisition console. The 3M 718 Static Sensor may then be used for remote monitoring or permanent recording of electrostatic voltage readings. 3M 718 Static Sensor Specifications Dimensions 0.85" (H) x 2.4" (W) x 4.15" (L) 2.2 cm (H) x 6.1 cm (W) x 10.5 cm (L)Weight 4.5 oz. (128 g) with battery Power Requirements One 9-volt alkaline battery Measurement Ranges 0 – 2 kV Low Range 0 - 20 kV High Range V oltage Display 3) digit liquid crystal display V oltage Output 1/1000 of measured voltage @ low range 1/10,000 of measured voltage @ high range Distance Indicator LED targets. Aligned targets indicate 1 in. (2.54 cm) measurement distance Measurement Accuracy Within 5% of actual voltage Certifications UL,C-UL,CE,CB-scheme,NOM 3 718 Static Sensor 718A Air Ionizer Test Kit 718 Range Finder Unfocused 718 Range Finder at 1" away 3M 718 Static Sensor 1 2 3

DRL600(8.3) 电力系统故障录波与测距装置说明书

DRL600 电力系统故障录波及测距装置说明书 Q/GDNZ.JB.183-2010 DRL600 电力系统故障录波与测距装置 说明书 XXX自动化股份有限公司

DRL600 电力系统故障录波及测距装置说明书 DRL 600 电力系统故障录波与测距装置 说明书 编写 审核 批准 V :8.3.00 XXX自动化股份有限公司 2018年07月

安全声明 为保证安全、正确、高效地使用装置,请务必阅读以下重要信息: (1) 装置的安装调试应由专业人员进行; (2) 装置上电使用前请仔细阅读说明书,应遵照国家和电力行业相关规程,并参照说明书对装置进行 操作、调整和测试,如有随机材料,相关部分以资料为准; (3) 装置上电前,应明确连线与正确示图相一致; (4) 装置应该可靠接地; (5) 装置施加的额定操作电压应该与铭牌上标记的一致; (6) 严禁无防护措施触摸电子器件,严禁带电插拔模件; (7) 接触装置端子,要防止电触击; (8) 如要拆装装置,必须保证断开所有地外部端子连接,或者切除所有输入激励量,否则,触及装置 内部的带电部分,将可能造成人身伤害; (9) 对装置进行测试时,应使用可靠的测试仪; (10) 请勿随意修改各配置文件,为了保证录波软件的正确性和完整性,在HMI模块内均备份了该工程 的数据配置文件和安装程序,配置文件如有修改,请立刻更新,便于在发生问题时能够及时恢复; (11) 由于本装置的HMI模块是通用操作系统平台,为了保证装置能够安全的运行,请勿在HMI模块内 安装其它任何应用软件。

DRL600 电力系统故障录波及测距装置说明书 版本声明 本说明书适用于DRL600电力系统故障录波与测距装置V8.0.00版带HMI硬件 产品说明书版本修改登记表 序号说明书版本号修改摘要产品版本号修改日期 1 V6.0.00 按6.0软硬件重新编写V6.0.00 2007/09 按V8.0.00版带HMI(MCU)通用装置 V8.0.00 2014/06 2 V8.2.00 硬件修改 3 4 5 * 技术支持电话:(025)51183239 传真:(025)51183220 * 本说明书可能会被修改,请注意核对实际产品与说明书的版本是否相符 * 由于产品的升级,可能会存在与本说明书不一致的情况,恕不另行通知 * 2014年6月第1版第1次印刷感谢您购买南京国电南自电网自动化系统有限公司的产品

M40气体检测仪使用说明

M40气体检测仪使用说明 目录 1 范围 (2) 2 规范性引用文件 (2) 3 术语和定义 (2) 4 操作内容 (2) 5 风险提示 (3) 6 应急处置 (4) 7 附件 (4)

1 范围 本作业指导书适用于指导M40可燃气体气体检测仪操作维护工作。 2规范性引用文件 3 术语和定义 M40可燃气体气体检测仪:是一款便携式的可燃气体检测仪,它能连续检测LEL的浓度,气体浓度的读数都会显示在液晶显示屏(LCD)上。仪器提供用户可自行设置的低浓度/高浓度报警,及STEL/TW A报警功能。当检测结果超出预先设置的报警设定值,仪器便以声、光及振动报警提醒用户。 ppm:表示百万分之一,环境大气(空气)中污染物浓度的表示方法之一。大部分气体检测仪器测得的气体浓度都是体积浓度(ppm)。mg/m3=(M/22.4)×ppm×(273/(273+T))×P/101325,其中,M为气体分子量,T为温度,P为压力。 4 操作内容 4.1操作步骤 4.1.1 取出气体检测仪,按下开关键。然后等待仪器准备就绪,注意电池电量。

4.1.2 待仪器准备就绪后,显示屏上会出现当前所测的气体含量数值。 4.1.3 将仪器的出口导管放置需要测量的地方,仪器即开始测量工作。在正常范围内,则仪器无报警;如所测气体超过标准范围,仪器则开始报警。 4.1.4 使用完毕后,长按开关键,关闭仪器。 4.2注意事项 4.2.1 注意经常性的校准和检测。 4.2.2 注意检测仪器的浓度测量范围。 4.2.3 要注意各类传感器的寿命。各类气体传感器都具有一定的使用年限,即寿命。因此,要随时对传感器进行检测,尽可能在传感器的有效期内使用,一旦失效,及时更换。以免造成不必要的损失。4.2.4 注意各种不同传感器间的检测干扰。 4.2.5 注意仪器采样口通畅,切忌堵塞。 5 风险提示

xpdm便携式露点仪分析操作指导书

XPDM便携式露点仪分析操作指导书 ----------------------------------------------------------------------------------- 一、引用标准: 本操作指导书依据Q/HS LH 1047-2008 气中水含量测定法(露点仪法) 标准和XPDM便携式露点仪分析仪器操作手册制定。 二、操作步骤: 1.正常分析(无需校正)步骤 1.1 按电源键打开仪器,等1分钟使仪器读数稳定。 1.2 使用和上下键选择所需的工程单位(一般选择 .XXX PPM )。 DEWPOINT PSI 1.3 当传感器仍处于干燥室中时,注意仪器显示的读数(湿度应低于要测气体的估计湿度)。 1.4 打开仪器连接口,选择合适的连接管路连接仪器和样气源,打开阀门把样气引进仪器。等一分钟,使测试室和样气管路干燥。 1.5 堵住仪器出气口。测量室内的气压足以推动活塞并使传感器进入测量室。如果压力不够,可用手慢慢拉动位于仪器前部的传感器传动装置(即仪器显示屏右侧的红色旋钮),同时仍堵住样气出口。 1.6 观察仪器读数变化。如果露点逐步增加,读数将在3分钟内稳定;如果露点逐步下降,将需要更长的稳定周期。当读数基本上稳定后,读取读数并利用传动装置把传感器推回到干燥室干燥以备下次使用。 2.当管道有压力,需要压力校正,则需按如下步骤进行: 。 2.1打开电源,短按一下 POWER ,出现 -101.1 ℃ DEWPOINT 2.2短按 PRESSURE 一下,出现 -101.1℃ CORRECT DEWPOINT PSI 2.3长按 PRESSURE ,出现 SET 14.7 ,此为标准值,一般不改。 CORRECT PSI 2.4 短按键一下,交替闪烁出现 SET CRS (14.77) 。 PSI 2.5用和上下键调节14.7(原始数值)到所需的压力数值

检测仪使用说明书

检测仪使用说明书 一.概述 核酸蛋白检测仪、紫外检测仪是液湘色谱仪中的一种紫外检测装置,核酸蛋白检测仪、紫外检测仪是根据生命科学的发展对于现代色谱仪器的要求而改进设计的一种新型紫外检测仪。该仪器在创新方面的主要特点为: 1.该仪器除配有输出10mV记录仪信号外,还配有输出适合计算机积分仪的输口,这 样很方便构成色谱工作站系统。(可同时进行计算机和记录仪信号输出,亦可省去记录仪) 2.该仪器的数字显示设计为固定光吸收,A显示计算机用和可变量程光吸收A显示记 录仪用两种可选模式,这样可方便于规范化读数(特别是可应用于药品生产的GMP 工艺规范化管理),同时亦可根据科研需要进行可变量程的高灵敏度读数,这样可方便于对低浓度样品检测。 3.该仪器采用新型进口IP28光电倍增管和改进型电路结构,使仪器工作更为稳定可 靠。 该仪器配有上层析柱、恒流泵、部分收集器等等,即组成一套完整的液色湘色谱分离分析系统。它可应用于现代生物学研究,药物测定、农业科研、化工、食品及医疗单位对具有紫外吸收的样品作定量分析。本仪器主要元器件均采用进口,仪器全部采用LED数字显示,使用方便。 二.主要技术性能 (1)核酸蛋白检测仪提供波长:254nm、280nm。 (2)紫外检测仪提供波长:220nm、254nm、280nm、340nm。 (3)量程范围:0~100%T、0~2A、0~1A、0~0.5A、0~0.2A、0~0.1A、0~0.05A。 (4)流式样品池:容积100微升、光程3毫米。 微量样品池:容积30微升、光程10毫米。 (5)记录仪输出:10mV (6)积分仪输出:0.1A/mV (7)数显模式:固定A量程读数(0~2.0A);可变A量程读数(0~2.0A、0~1.0A、0~0.5A、0~0.2A、0~0.1A、0~0.05A)。 (8)量程在0.05A档时:噪音≦0.002A。 (9)工作环境温度:0℃~35℃。 (10)仪器可连续工作。 (11)电源:220VAC±10%50HZ。 (12)单体外形尺寸:280×180×158(mm)。 (13)主机重量:5㎏。 三.工作原理 从光源发出的光经狭缝,滤色器聚焦到样品池上,此单色光通过样品池射到光电倍增管的光阴极面上,使光束由于样品浓度不同所引起透光强度的变化转换成光电流变化,此光电流经放大器放大,并输入到对数转换器、使透光率T转换成光吸收A输出即A=lgT/1=ε·CL式中ε为待测样品的摩尔消光系数,C为样品浓度,采用摩尔/升单位,L为光程,用厘米作单位。根据上式只要测出了A、L和ε就可求出样品浓度C。若从放大器直接输入到记录仪,则在记录仪上绘出的是样品透光率T变化的图谱,若从对数转换器输入到记录仪上,在记录仪上绘出的是样品光吸收变化的图谱。 四.仪器结构 核酸蛋白检测仪、紫外检测仪是单光路结构,由紫外检测器、和记录仪部分组成现将其构造分别说明如下: 1.紫外检测仪: 它由光源、干涉滤色片、样品池、光电倍增管、放大和对数板、低压板和高压板等组成。面板上有四氟塑料管的进样口和出样口,A调零以及调节“光量”大小旋(光

氢气露点仪使用说明(建议稿)

露点仪使用方法(建议稿) PANAMETRICS MOISTURE TARGET SERIES 5+ (仪器上盖的标识,不知是否英文名) 郑州光力科技发展公司露点仪 一、现场测试 1,进入现场前,将直流电源开关拨至“ON”位置,PC指示灯亮,此时直流电在工作。 2,将连接软管连接至现场取样接口,打开取样阀,冲洗取样软管3-5分钟。 3,将仪器进气开关关紧,然后打开干燥器(手柄按顺时针方向转动90°,让手柄上红点对应至“TEST”),同时将进气口、排气口堵头拧下,将取样软管接入仪器进气口,然后调节流量调节阀转轮,使气体流量达到1.2—1.6 L/Min。 4,打开主机“POWER”键,进入测量状态,此时数值显示屏应有数值显示。 5,当显示读数稳定时,记录测量值T1,测量完毕,关闭主机按“POWER”键和“ENTER” 键,而后关闭氢气取样阀,将流量调节阀转轮按顺时针方向将阀门关紧,拧下取样软管连接螺母,同时将进气以及排气口的堵头拧上。 6,干燥器取样系统的手柄按逆时针方向转动90°,让手柄上红点对应“DRY”,这样即可使仪器进入干燥状态。 7,离开现场后,将开关键拨至“OFF”位置。 二、发电机氢气露点的计算方法 1,露点仪测得的发电机氢气露点为T1, 2,露点仪所处的氢气绝对压力P1(0.1MPa), 3,发电机中氢气的表压P2, 4,发电机中氢气的绝对压力P3= P1+ P2=0.1+ P2 5,根据露点仪测得的发电机氢气露点为T1查“冰的饱和水蒸汽压表”得出露点为T1时所对应的饱和水蒸汽压es1, 6,发电机运行氢压下的饱和水蒸汽压es2= es1(P3/ P1) 7,根据es2在“冰的饱和水蒸汽压表”查得的对应露点值即为发电机运行氢压下的露点T2。8,根据露点T2查“露点、绝对湿度换算表”所对应的绝对湿度,即发电机中氢气的绝对湿度。 三、充电使用方法 1,接通充电器电源,使仪器开关拨至“OFF”位置。 2,将充电器输出开关插入仪器的充电口,此时标有“CHG”的指示灯亮,表示已进入快充状态。 3,待4小时后,拔掉充电器插头,切断电源即可结束充电过程。 四、注意事项 1,测试H2气体时,一定要使用直流电源。 2,测量H2气体时,务必在进入现场前,将直流电源开关拨至“ON”位置,测量现场不能打开或者关闭此键。 3,长时间不用直流电源时,一定要将开关键拨至“OFF”位置。 4,当仪器自动报警时,表示电池电源不足,请及时充电

全自动生化仪使用说明书.doc

便携式生化检测仪 340 使用说明书便携式生化检测仪

【产品名称】便携式生化检测仪 【型号】340 【产品性能】 便携式生化检测仪(以下简称POC)。 POC专用于检测本公司体外诊断试剂盒“同型半胱氨酸检测试剂盒”,用于定量检测临床血清或血浆样本中同型半胱氨酸(HCY)。 POC是集样本处理、检测及分析报告一体化的便携式生化检测仪,无需外置电脑和安装软件。一次检测一份样本,约15分钟内完成检测并报告定量检测结果,具有机体小巧、携带及安装简便,操作简单快捷的特点。 POC控制过程:将含有检测试剂及样本的专用检测管放入测试盒内后,通过触摸屏控制,读取RFID 卡上的参数,自动完成搅拌、孵育、检测;自动计算样品中被检物的浓度并报告检测结果。 产品主要性能参数如下: 重量:3.5kg 外形尺寸:260×145×140cm 检测波长:340nm 自动控温:37℃ 电源:由电源适配器将电网电源AC100-240V,50/60Hz转换为DC12V电流4.0 A。 额定功率:30VA 工作温度:15℃~30℃ 相对湿度:40%~85% 大气压力:86.0 kPa~106.0 kPa 储存:经包装后的POC应存储在0℃~40℃,相对湿度不超过85%,无腐蚀性气体和通风良好的环境内。 运输:运输过程中应防止受到剧烈冲击、雨淋和曝晒。 【适用范围】 本仪器仅与本公司生化检测试剂盒“同型半胱氨酸检测试剂盒”配套使用,用于定量检测临床血清或血浆样本中生化成分检测。 【禁忌症】 无。 【主要结构】 由主机和电源适配器组成,仪器外观见图1,接口见图2。

图2仪器背面接口 【注意事项、警示以及提示性内容】 1.严禁非授权维修人员自行拆开机体。 2.禁止使用非专用管,以免损坏仪器。 3.检测操作时,放入检测管以前,确认管盖盖严,拭净管体外残留液体。 4.当系统工作时,切勿接触系统上的运动部件。 5.不可手动开检测盖。 6.使用触摸屏,只能用手指接触,禁止使用笔或尖锐物体接触。 7.必须使用专用的试剂盒,使用前确认试剂盒的适用性。 8.必须使用专用的试剂盒专用RFID卡,否则无法检测。 9.必须在有效期内使用试剂盒和RFID卡。 10.使用试剂、样本应严格按照相关管理规范执行。 11.剩余试剂、样本及废弃物的处理严格执行国家有关医疗废弃物处理规范执行。 12使用过的仪器进行运输、维修或储存前,应用75%的酒精对检测盒及仪器表面仔细清洁消毒,以防止污染及可能的生物风险。 【图形、符号、缩写的解释】 图形、符号、缩写名称解释 警告指本部位存在一定的危险,操作时应小心。 参考说明书参考说明书 怕晒表明运输包装件不能直接照晒 怕雨表明包装件怕雨淋 禁止翻滚表明不能翻滚运输包装

智能型手持式便携式三合一气体检测仪说明书

三合一气体检测仪 (手持式、便携式) 操 作 手 册 2014年12月05日

声明: 本手册是多合一气体检测仪的通用操作手册,本手册中提到某些功能和界面,会因为检测仪实际配置的传感器不同而不同,在阅读时应注意区分。 软件升级后,界面和操作方法可能会有所变动。纸质说明书通常都是批量印刷,所以如果有变动,不另行通知。升级后我们仅提供最新版本的电子版本说明书,敬请谅解! 本手册中所包含的所有数据和信息如有变更,恕不另行通知。保留勘误权。

目录 装箱单 (5) 注意事项 (5) PID光离子传感器注意事项 (8) 仪器参数 (10) 校正采用的标准 (11) 统计值的计算方法 (11) 仪器报警的判断条件 (11) VOC气体规则 (12) 仪器正面图解 (13) 开机关机重启待机硬重启 (14) 关于电池充电 (15) 文字输入方法 (16) 使用采样管和粉尘过滤器 (17) 开始工作 (18) 开始检测 (19) 按钮示意 (20) 菜单 (21) 设置检测地点、检测时长、定时检测 (22) 锁定与解锁 (23) 查询数据 (24) 使用电脑查询的操作方法 (26) 打印检测结果 (27) 启动打印 (27) 设置打印机 (28) 设置打印样式 (29) 数据备份 (30) 配置 (31) 修改时间 (31) 仪器工作方式 (32) 传感器配置和标定 (33) 配置模拟信号传感器 (34) 模拟信号传感器的标定操作 (34) 串口信号传感器 (36) PWM脉冲信号传感器 (37) 气象环境传感器 (38) 检测项目 (39) 基本参数 (39) 自定义公式 (40) 【自定义公式应用案例】 (40)

露点仪的使用与维护

露点仪的使用与维护 目前,国内外在使用的露点仪有许多种。但从测量原理来分主要的有㈠镜面冷凝式光电精密露点仪。是作为计量标准器具来使用的,主要分布在国家计量院和各省市的技术监督局的计量所。㈡电解式微量水湿度仪,在国内只有成都仪器厂和上海唐山仪表厂生产。主要用在一些化肥厂坐在线测量。这两个厂家的仪器一般在一到两年就要更换一次电解池。㈢阻容式露点仪,目前在我们国内的用户,除了我们公司生产有此类仪器外,国外仪器如:英国xx,英国xxx都是采用此种原理。 阻容式原理的露点仪实质上是仪器的传感器采用陶瓷薄膜阻容 式湿度传感器。 阻容式湿度传感器: 阻容式湿度传感器的敏感元件为湿敏电阻,其主要材料为半导体,高分子聚合物和多孔陶瓷,这些材料对水的吸附性较强,其吸附水分多少随湿度而变化,材料的电阻率也随吸附水分的多少而变化。这样,湿度的变化可导致湿敏电阻阻值的变化,电阻值的变化就可以转化为需要的电信号。 电容式湿度传感器: 电容式微量水份传感器主要由感湿膜、电极和绝缘基板组成。先在绝缘基板上镀上一个梳状金电极,然后再在梳状金电极上涂敷一层感湿膜,最后再在感湿膜层上喷涂一层梳状金电极。被测气体中的水蒸气通过感湿膜吸附来改变电容式湿度传感器的阻抗值或者说电容

量实现微量水份含量的测量。当被测气体中的水蒸气多或者说被测气体的露点高时,感湿膜吸附的水份就多,湿度传感器的阻抗值就低,或者说电容量大;反之,当被测气体中的水蒸气少或者说被测气体的露点低时,感湿膜吸附的水份就少,湿度传感器的阻抗值就高,或者说电容量小。由此,电容式湿度传感器就完成了水分含量的多少到电量的大小的转换。 阻容式露点仪的特点: 阻容式微量水分析仪(露点仪)的优点:①具有较宽的响应范围,可准确测量一80℃一+20℃的露点;②既可以远程安装,也可以现场使用;③性能相对稳定,响应较快,温度系数较小,与流量变化无关;④对水分有较高的选择性,可以在较宽的温度和压力范围内使用;⑤除供电电池外无任何消耗品;⑥日常维护量较小,使用寿命长,一般使用寿命在5年以上;⑦设有自动校准功能,可以随时自动校准。阻容式微量水分析仪的缺点是:采用间接测量方式,在较高的温度下操作容易引起仪器漂移,仪器工作一定时期后要进行校准。 使用阻容式露点仪建议: 1)由于市面上销售的露点仪器均采用了阻容式原理测量露点的。为保证仪器测量的准确性,必须定期校准,以减少仪表老化、滞后及污染的影响。仪器必须一年标定一次,传感器根据现场的实际使用情况3至4年需重新更换。仪器使用7年后需报废。 2)由于温度,湿度,压力,电磁环境等效应的综合影响,可引起露点仪湿度传感器零点漂移和灵敏度的变化。因此露点仪的存放位置尽量

XPDM型便携式露点仪安全操作SOP

XPDM型便携式露点仪安全操作SOP 分发部门 生产部□一车间□二车间□三车间□四车间□五车间□六车间□七车间□质量部□QA □QC □供应部□仓库□工程部□行政部□销售部□研发部□安全环保部□财务部□

目的:制定XPDM型便携式露点仪标准操作程序,规范操作行为。 应用范围:适用于XPDM型便携式露点仪的使用。 责任人:QA主管、QA检查员、质量部负责人。 内容: 1设备介绍 1.1设备用途 XPDM型露点仪是由电池供电的便携式仪表,可以在﹣100℃~+20℃的范围内快速准确地测量干燥空气或其他气体的湿度。 1.2设备原理介绍 仪器内部有一根内芯为高纯度铝棒的传感器,表面氧化成氧化铝薄膜,其余涂着一层多孔的金膜,该金膜与内芯之间形成电容,由于氧化铝薄膜的吸水特性,当水蒸气分子被吸入其中时,导致电容值发生变化,检测并放大该电信号即可得到湿度大小。 2安全操作程序 2.1开机前准备 2.1.1接口连接 根据不同的应用设备,仪器可采用不同的连接接口。仪器本身的气样入口为1/4”VCO母螺纹接口,连接时英密封好以确保较低露点气体的准确测量。 连接实际设备,可以采用下列连接方法: VCO→VCO:此方法对应所有应用都非常理想,如易弯不锈钢软管。 VCO→Swagelok:此方法适用于刚性连接管的场合。(随仪器提供该接口) VCO→Barbed hose:此方法适用于露点高于﹣65℃气体的测量,仅可以用PTFE管连接。(随仪器提供该接口) 2.1.2管路连接 对低于﹣65℃的露点气体,应使用内抛光的不锈钢的不锈钢管道(可向厂家订购),且该连接管道的长度应尽可能的短,以确保最快达到湿度平衡。对于低流速的待测样气,可以在出口处连接不锈钢弯管,以避免外界空气的回流。 注:在任何情况下,都不能使用橡胶或者塑料管,因为它们都具有吸湿性和可渗透性,会产生较大的测量误差。 2.1.3采样条件 前级过滤器:当测量低于﹣65℃露点的气体时,不要使用任何用油、颗粒或水的前级过滤器。因为这样的过滤器会存储并释放水蒸气,从而减慢或影响测量效果。 压力调机器:不能把含有不锈钢之外的任何材料的压力调节阀使用在低于﹣65℃的露点情况下。 2.2开机测试 2.2.1当管道有压力 如果传感器周围气体(测试室内)和测试气体存在较大压力差时,需要进行压力校正,步骤如下:注:根据定义PPM、LBS和G/M3的读数不受压力修正影响,所以单位是℃和℉才用压力校正。 短按POWER键,打开电源,出现 ﹣℃ DEWPOINT

空气质量检测仪使用说明书

分光打印室空气检测仪 (电脑版可调式六合一中文显示分光光度打印室空气检测仪器) 数据可调型 使用说明书

尊敬的客户: 您好!为保证您在使用过程中具有更好的安全性和有效性,请您务必注意以下事项: 1.为了确保您能够正常操作,在使用仪器前,请仔细阅读仪器使用说明书。2.我公司仪器以便于携带和现场快速检测为其主要特点,对被测样品的品质和安全能够实现快速现场检测;其检测结果可以作为法律裁决的前期基础参考数据。 3.仪器所用试剂为化学药品,绝对禁止儿童及无关人员接触试剂,否则发生意外责任恕请自负。 4.使用仪器须知: 检测结束后,必须关闭所有仪器设备的电源,以免发生以外。 注意吸收瓶和仪器的连接,防止倒吸,损毁仪器。 启动仪器之前注意胶管位置,避免触地,防止异物吸入。 不要在没有流量或流量很小的情况下长时间让气泵处于工作状态,以免影响机器寿命。 仪器工作时要保持水平。 防止仪器剧烈振动。 切开检测管时注意伤手,玻璃渣要妥善处理。 使用三脚架时注意平衡。 仪器特点 ▲多功能:可检测室空气中的甲醛、苯、氨、甲苯、二甲苯、TVOC有害气体。▲流量稳定:为了适应室环境监测的需要,该仪器采用了大流量泵,可调阻力流量计,具有流量稳定,精度较高的特点,能很好适应苯、氨、甲苯、二甲苯、TVOC 等检测管有较大采样阻力的情况; ▲自动控制:可在0~99小时任意设定时间,操作方便、直观。在控制面板设定采样时间,采样结束时自动停止工作。时间精度高,采样误差不超过0.1秒; ▲温、湿度指示:面板上可以显示检测现场的温度及湿度,可以直观地反映采样现场的环境状况(可选)。 ▲现场测定甲醛含量。 ▲甲醛超限声、光报警提示。 ▲现场热敏打印定制格式的检测报告。 ▲轻便:本仪器体积小,重量轻,携带方便。 ▲电源:接220V交流电,强电、弱电分别独立控制。 ▲包装:仪器的外包装为小型铝合金手提箱。

北京博电MR1200D便携式故障录波器技术参数

北京博电MR1200D便携式故障录波器技术参数 1.同步采样模拟通道 A / D分辨率:16位 有效值计算精度:0.2% MR1200D标准配置 模拟量通道数:8路 模拟量通道配置: 交/直流(AC/DC)电压通道: 4 x 1000V 外接电流钳式电流输入通道: 4 x 100A 直流通道: 1x ±1000V 1x -10~10V 1x 0~200mV 1x 4~20mA 开量输入路数:16 开关量输出路数:4 最高采样频率:100 KS/s (2000点/周波) 最大记录容量:200GB GPS B码绝对时间接入:支持 信号调理模块的种类配置也可根据用户要求调整,可供配置的变换器类型如下表所示,软件可自动识别;每个模块有多个量程,用户可通过软件分别设置各模块量程。 2. 同步采样开关通道 通道数为16路 开关量分辨率:0.01ms 信号类型:既可以是无源触点也可以是有源触点,软件自设; 3. 实时计算量误差 有效值误差:0.2% 频率误差:±0.01Hz 相位误差:±0.2° 4. 同步采样开关通道 同步采样频率:1kS/s~100kS/s,用户可通过软件设置采样频率

5. 长时间连续记录波形原始数据 记录仪在全通道同步采样、采样率为1kS/s时的记录时间不低于3000小时,时间如下表所示: 采样率为50KS/S 60小时 采样率为10KS/S 300小时 采样率为1KS/S 3000小时 6. 波形编辑: 可以对波形进行幅度调整、选时段、选通道、用光标显示某一时刻各通道值; 7. 故障启动方式 模拟量启动 瞬时值、有效值、频率的过量、欠量、突变量启动 开关量启动 开关量变位启动(包括开关量的断开和闭合) 定时启动 用户可通过软件设定录波启动时间 手动启动 用户可通过软件设定手动启动是否使能 高级启动 负序、零序启动等 8. 发电机-变压器组电气试验功能 励磁试验,包括灭磁试验、10%阶跃试验等。 同期试验 用户要求的其它试验(如变压器试验等) 9. 录波容量 录波存储容量最大可达200GB 10. 通讯接口 网络接口:1个10Mbps/s网络接口 通用串行总线接口:4个USB接口 11. 显示屏

相关文档