Sybase_926数据库挂起、3414错误解决方法

Sybase_926数据库挂起、3414错误解决方法
Sybase_926数据库挂起、3414错误解决方法

Sybase 926数据库挂起、3414错误解决方法(Error: 926 Error: 3414)一、查看错误日志 errorlog 发现了这段记录

00:00000:00001:2009/04/28 16:13:36.46 server Error: 926, Severity: 14, State: 1

00:00000:00001:2009/04/28 16:13:36.46 server Database 'FD_JXC' cannot be opened. An earlier attempt at recovery marked it 'suspect'. Check the SQL Server errorlog for information as to the cause.

00:00000:00002:2009/04/28 16:13:36.46 kernel network name

200.100.101.100, type ether, port 5000, filter NONE

00:00000:00003:2009/04/28 16:13:36.48 kernel network name yzserver, type ether, port 5000, filter NONE

00:00000:00001:2009/04/28 16:13:36.48 server Unable to proceed with the recovery of dbid <4> because of previous errors. Continuing with the next database.

明显的 926 数据库挂起错误,即先将数据库状态修改为 -32768 然后再修改为0

/* 1、将 'allow updates' 从 0 改为 1 允许修改系统表*/

sp_configure "allow updates", 1

/* 2、将数据库状态修改为 -32768 即 bypass recovery */

update sysdatabases set status = -32768 Where name="FD_JXC"

这时需要停止Sybase服务并且重新启动Sybase

/* 3、将数据库状态修改为正常 status=0 */

update sysdatabases set status=0 where name="FD_JXC"

sp_configure "allow updates", 0

第二次停止Sybase服务并且重新启动Sybase

这步完成后一般重新设置数据库选项(例如"select into","trunc log on chkpt"等)

exec sp_dboption FD_JXC, 'select into/bulkcopy' ,true

exec sp_dboption FD_JXC, 'trunc. log on chkpt' ,true

运行dbcc命令检查数据库的一致性

dbcc checkdb(FD_JXC)

备份用户数据库

dump database FD_JXC to "D:\backup\FD_JXC0428.dump"

晕死,眼看胜利在望,服务器蓝屏,无语,破机器,只好非法关机重新启动,启动好后数据库还是无法正常使用,再查看错误日志 errorlog ,我的神啊,竟然变成3414错误了,肯定是刚才蓝屏的时候,数据库在恢复日志被中断了,这样就要重建数据库日志了

190197: Master device size: 30 megabytes, or 15360 virtual pages. (A virtual page is 2048 bytes.)

00:00000:00001:2009/04/28 16:40:14.75 server Error: 3414, Severity: 21, State: 1

00:00000:00001:2009/04/28 16:40:14.75 server Database 'FD_JXC' (dbid 4): Recovery failed. Check the SQL Server errorlog for further information as to the cause.

Error: 3414, Severity: 21, State: 1 Database 'FD_JXC' (dbid 4): Recovery failed. Check the SQL Server errorlog for further information as to the cause.

解决办法: 重建数据库日志,方法如下:

/* 1、赋予sa用户sybase_ts_role的角色 (这步最重要,我一开始没搞,费

了不少工夫) */

sp_role "grant","sybase_ts_role",sa

/* 2、将数据库状态修改为 -32768 即 bypass recovery */

sp_configure "allow updates",1

update master..sysdatabases set status =-32768 Where name="FD_JXC" 这时需要停止Sybase服务并且重新启动Sybase

/* 3、rebuild数据库日志 */

dbcc rebuild_log(FD_JXC,1,1)

第二次停止Sybase服务并且重新启动Sybase

/* 4、将数据库状态修改为正常 status=0 */

update master..sysdatabases set status=0 Where name="FD_JXC"

sp_configure "allow updates", 0

5、还要第三次停止并重启Sybase服务,如果数据库恢复正常,rebuild log工作将会成功完成,

否则要恢复数据库备份,使用dump database或bcp命令。

6、重新设置数据库选项(例如"select into","trunc log on chkpt"等)

exec sp_dboption FD_JXC, 'select into/bulkcopy' ,true

exec sp_dboption FD_JXC, 'trunc. log on chkpt' ,true

运行dbcc命令检查数据库的一致性

dbcc checkdb(FD_JXC)

备份用户数据库

dump database FD_JXC to "D:\backup\FD_JXC0428.dump"

USB设备失灵的解决方法

USB设备失灵的解决方法 当WindowsXP用户正在玩游戏的时候,突然鼠标不能动了,然后用户将鼠标换个USB接口后完了一会又不能动了。这是怎么回事呢?下面小编就为大家介绍一下关于这个问题的解决方法吧,欢迎大家参考和学习。 USB设备失灵的解决方法: 一、设置CMOS参数 对于从来没有使用过USB外接设备的朋友来说,即使正确安装了驱动程序也有可能出现系统无法检测USB硬盘的情况,这主要是由于主板默认的CMOS端口是关闭的,如果没有将其设置为开启状态,那么Windows自然无法检测到移动硬盘了。 为了解决这个问题,我们可以重新开机,进入CMOS设置窗口,并且在“PNP/PCI CONFIGURATION”栏目中将“Assign IRQ For USB”一项设置为“Enable”,这样系统就可以给USB端口分配可用的中断地址了。

二、电源不足 由于USB硬盘在工作的时候也需要消耗一定的电能,如果直接通过USB接口来取电,很有可能出现供电不足。因此,几乎所有的移动硬盘都附带了单独的外接电源或者是通过键盘取电的PS2转接口,这时只要事先连接好外接电源或者通过PS2转接线与键盘连接好,确保给移动硬盘提供足够的电能之后再试试,这时应该可以正常使用了吧。需要特别提醒大家注意的是,建议使用移动硬盘之前都确保有足够的供电,否则很可能由于供电不足导致硬盘损坏。 三、USB延长线故障 除去上述两方面原因之外还有可能是USB接口类型不符导致移动硬盘无法使用。比如计算机配置的USB接口是1.1标准的,而购买的移动硬盘是USB 2.0标准的接口,这就要求连接计算机和移动硬盘的连接线必须支持USB 2.0标准。因为高速移动设备插入低速集线器,该设备可能不被正常安装,而有些朋友在使用移动硬盘的同时还使用优盘,为了方便就直接使用优盘附送的USB 1.1标准连接线,这样就导致USB 2.0标准的移动硬盘无法正确识别。只要将连接线更换为USB 2.0标准的即可解决此故障。 四、Windows版本太低

exchange装入数据库失败解决办法.pdf

Microsoft Exchange 错误 装入数据库“xxxx”失败。 xxxx 失败 错误: Exchange 无法装入指定的数据库。指定的数据库: WIN2003\xxxx\xxxx;错误代码: MapiExceptionCallFailed: Unable to mount database. (hr=0x80004005, ec=-515) 首先声明我用的是exchange server 2007 还有类似的比如544、455错误等,主要是因为某种原因数据库的日志文件丢失或者错误造 成的。可以通过以下方法来解决。 这里要使用到eseutil.exe这个程序,他在ex的安装目录下的\bin\eseutil.exe 好下面我们来操作来恢复日志文件。 首先关掉杀毒软件,这主要是为了防止它扫描ex安装的目录造成文件锁定之类的问题,然 后在出问题的数据库所在的的目录,比如 \exchange\mailbox\firststroagegroup目录下是数据库所在目录,那么在这个文件夹上 运行cmd,然后再命令窗口中输入 eseutil -p "xxx.edb" ; 然后运行 eseutil -mh "xxx.edb",在显示出来的结果中查看状态 = 干净关闭或者state=cleanshut;然后我们进行下一步运行eseutil /r e00 ,运行后会看到很多log文件,这里最后会提示你最后一个log文件是比如 0ad,缺少了log文件0ae,这说明丢失了0AE.LOG这个文件,不要紧,进行下面操作, (注意)虽然进行后会丢失0ad之后的数据,但是也比加载不了数据库好吧!来吧继续 吧: 找到\exchange\mailbox\firststroagegroup目录下最新的LOG文件,将其改名为LOG文件的最前三个字符,比如LOG文件全名是“e000000000ad”那 么把它改成“e00”,同理如果是“e010000000ad”那么把它改成“e01”,这时你会发现本 文件夹有E01这个文件重复了,备份好原来的那个文件,然 后删除它,再吧0AD改名成E00,好啦大功告成了,去EMC里加载这个数据库试试,是不 是可以了奶? 哈哈其他数据库也这么操作,OWA又可以正常访问了嘎嘎! 下面是微软给出的官方说法,其实跟我的一样,只不过是绕口点: 使用下列方法之一恢复 Exchange 日志文件: 方法 1:如果 Exchange 日志文件被隔离 将 Exchange 日志恢复到包含生产日志文件的文件夹。 启动"Microsoft Exchange 信息存储"服务。如果不缺少任何其他日志文件,将装入数据 库。如果缺少其他日志文件,请查看缺少的日志文件是否位于 防病毒程序的隔离文件夹中。如果日志文件不在隔离文件夹中,请参阅方法 2。 如果 Exchange 日志文件被删除,则必须通过备份还原存储组数据库。然后必须重播日志 文件。若要还原可用的数据库,请执行下列步骤:

mysql实施方案

1总体结构 2*Cobar+8*(1主+1主)结构 2单mysql服务器部署 2.1 服务器的系统配置 硬件: 16台PC服务器,(CPU数)/64G内存,2*300G本地盘,RAID0+1,可用存储空间300G。 软件: 操作系统:RHEL6。 MySQL数据库:Percona最新的版本,当前是5.6.14。 基准测试工具:SysBench,模拟应用场景提供基准性能测试数据; 压力测试工具:mysqldap,指定并发用户、并发数、操作语句等测试mysql 服务器的内存、CPU、IO的性能; 2.2 Mysql的安装 1.Mysql使用Percona的5.6.14。 2.下载Percona-Server-5.6.14-rel62.0-483.Linux.x86_64.tar.gz包,解压。 3.初始化mysql,使用./scripts/mysql_install_db脚本初始化mysql,使用命令./scripts/mysql_install_db --datadir=/home/upay/mysql/data/ --defaults-file=/home/upay/mysql/https://www.360docs.net/doc/428509528.html,f。其中—datadir为数据目录, --defaults-file为配置文件。

2.3 Mysql的配置参数 [mysqld] #basedir=/disk1/weblogic/lcecs7/mysql-5.6.14-linux-glibc2.5-x86_64 basedir=/home/upay/Percona-Server-5.6.14-rel62.0-483.Linux.x86_64 datadir=/home/upay/mysql/data port=33306 socket = /home/upay/mysql/mysql.sock #lower_case_table_names = 1 #binlog_cache_size = 4M #max_heap_table_size = 128M #sort_buffer_size = 16M innodb_additional_mem_pool_size = 128M innodb_buffer_pool_size = 48G innodb_file_io_threads = 4 innodb_flush_log_at_trx_commit = 1 [mysqld_safe] log-error=/home/upay/mysql/mysqld.log pid-file=/home/upay/mysql/mysqld.pid 2.4 MySQL服务器的性能 2.4.1简单性能测试 Mysqlslap指令:./mysqlslap -h10.20.38.11 -P33306 -ucobar -pcobar -a -x5 -y5 -i 5 --number-of-queries=5000 -c50(5000简单语句,50并发)

USB设备无法识别故障排除

USB设备无法识别故障排除 当你想用闪存或移动硬盘来和电脑交换数据时,但插上USB口时你却发现系统居然无法识别出USB 设备,这是什么原因造成的呢?其实这样的现象我们时常见到,接下来介绍一下简单的处理方法。 一、在排除USB存储设备本身故障后,出现无法识别现象的原因一般是由以下几个方面所造成的: 一是USB接口电压不足。这种故障通常存在于移动硬盘身上,当把移动硬盘接在前置USB口上时就有可能发生系统无法识别出设备的故障,原因是移动硬盘功率比较大要求电压相对比较严格,前置的USB 接口是通过线缆连接到机箱上的,在传输时便会消耗大掉的电压,因此,在使用移动硬盘时,要注意尽量接在后置主板自带的USB接口上,否则也可以通过外接的电源适配器来提供单独供电。当然,在一些老的主板上,必须要使用独立供电才能供正常使用USB设备。 二是前置USB线接错。当主板上的USB线和机箱上的前置USB接口对应相接时把正负接反就会发生这类故障,这也是相当危险的,因为正负接反很可能会使得USB设备烧毁,严重还会烧毁主板。三是主板和系统的兼容性问题。这类故障中最著名的就是NF2主板与USB的兼容性问题。假如你是在NF2的主板上碰到这个问题的话,则可以先安装最新的nForce2专用USB2.0驱动和补丁、最新的主板补丁和操作系统补丁,还是不行的话尝试着刷新一下主板的BIOS一般都能解决。四是系统或BIOS问题。当你在BIOS或操作系统中禁用了USB时就会发生USB设备无法在系统中识别。解决方法是开启与USB设备相关的选项。 二、U盘插入电脑,提示“无法识别的设备”故障 维修思路:对于此现象,首先的一点说明U盘的电路基本正常,而只是跟电脑通信方面有故障,而对于通信方面有以下几点要检查: (1)U盘接口电路,此电路没有什么特别元件就是两根数据线D+ D-,所以在检查此电路时只要测量数据线到主控之间的线路是否正常即可,一般都在数据线与主控电路之间会串接两个小阻值的电阻,以起到保护的作用,所以要检查这两个电阻的阻值是否正常。 (2)时钟电路,因U盘与电脑进行通信要在一定的频率下进行,如果U盘的工作频率和电脑不能同步,那么系统就会认为这是一个“无法识别的设备”了。这时就要换晶振了。而实际维修中真的有很多晶振损坏的实例! (3)主控,如果上述两点检查都正常,那就可以判断主控损坏了。 三、Windows XP操作系统下,系统提示已经找到新的硬件并且硬件正常被安装可以使用,但无法找到闪存盘的盘符,且闪存盘的灯在不停的闪亮 故障分析:这种故障一般是由于非法操作所造成的,认为闪存盘是可以支持热插拔的,于是在没有正确删除移动设备的情况下,直接进行了插拔操作,不正确的操作是导致闪存消失的根本原因。 故障排除:进入Windows 98系统,用鼠标右击“我的电脑”,选择属性进入“设备管理器”,在“磁盘驱动器”下看到比原来多了一个“Netac Onlydisk”的设备,双击进入,在弹出的新窗口中看到了四个新的选项:“断开”、“可删除”、“同步数据传输”和“Int 13单元”,仔细观察发现“可删除”前面的选项是没有打勾的。在“可删除”选项前的空格内打入勾并单击确定后重新启动电脑。 故障小结:此故障依然是由于误操作使用闪存盘导致的问题,可以看出由于不正常使用闪存盘而导致故障出现的机率是非常大的,因此大家在使用中一定要遵循规格,以保证闪存的正常使用。 四、可以认U盘,但打开时提示“磁盘还没有格式化”但系统又无法格式化,或提示“请插入磁盘”,打开U盘里面都是乱码、容量与本身不相符等。 维修思路:对于此现象,可以判断U盘本身硬件没有太大问题,只是软件问题而以了。 解决方法:找到主控方案的修复工具搞一下就可以了。这个就要大家自己看U盘的主控是什么方案的来决定了。 U盘故障大概也就是这些主要问题了。而对于无法写文件、不存储等现象,一般都是FLASH性能不良或有坏块而引起的。大家看完之后有没有一个清晰的思路了呢。随便说明一下,U盘不同于MP3,他不存在固件之说,但有些厂家把自己的软件放到里面,低格一下就会没有的。 告诉大家一个非常简单的方法,就是在碰到主控损坏或找不到相应的修复工具时,可以用U盘套件来重新搞一个新的U盘,方法就是把故障机的FLASH拆下来,放到新的PCB板上就可以了。U盘套件包括(PCB带主控(分1.1和2.0之分)及外壳一套),维修起来非常简单,做数据恢复就更方便了。

mysql 安装到最后一步时,start service 为失败状态

mysql 安装到最后一步时,start service 为失败状态请问是什么原因 使用services.msc打開服務窗口,查看MySQL service是否已經存在。如已经存在并已启动,则先停止该服务,然后到注冊表("HKEY_LOCAL_MACHINE\SYSTEM \CurrentControlSet\Services")中刪除對應服務,并使用命令sc delete MySQL,然后繼續進行安裝,就能成功。 MYSQL安装出现could not start the service mysql error:0处理收藏 当各位在安装、重装时出现could not start the service mysql error:0 的错误时,可以尝试下面两种方法。 一、方式1 MySQL安装是出现could not start the service mysql error:0 提示错误,解决方法: 首先,在管理工具->服务里面将MySQL的服务给停止,然后打开cmd 进入你的MySQL bin目录下,例如 C:\Program Files\MySQL\MySQL Server 5.0\bin 然 后使用如下命令mysqld-nt -remove 然后就会显示......success! 好了下面进入添加删除程序,找到MySQL选择卸载,记得选择remove。最后将MySQL目录 删除,还有数据库的目录也删除。 一、方式2 查看服务中有没有mysql,如果有将该服务停掉; 安装mysql 5.1.33,在运行Server Instance Configuration wizard时的Execute configurattion步骤中的第三项Start Service进出错,错误提示为Could not start the service MySQL (出现这种情况一般是因为装过mysql,卸载不干净 造成的。卸载后重启后再重装。注意看下服务,如果未能卸载,可以用mysqld-nt -remove卸载)。 在控制面板中运行添加删除程序,将mysql卸载; 卸载后打开注册表,查看 HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services 下的键值,如果有 相关mysql键值(mysql、mysqladmin)则删掉,即可; 重启,将mysql的安装残余目录删掉 (查看服务,此时服务中已没有mysql); 重新安装mysql.安装后先不要运行Server Instance Configuration wizard, 重启后在开始菜单中运行该向导,即可。 windowsxp系统 mysql-5.0.81 提示:1045 access denied for user 'root'@'localhost'using password yes MySQL 5.1 安装过程中报apply security setting错误的解决办法收藏 Mysql安装错误apply security settings 解决方法

数据库项目组日常运维与应急故障处理手册范本

常见问题及处理方案 CPU使用率高的问题 通过操作系统命令top topas glance等查看top进程号,确认是系统进程还是oracle应用进程,查询当前top进程执行的操作和sql语句进行分析。 根据进程号获取正在执行的sql SELECT a.osuser, https://www.360docs.net/doc/428509528.html,ername,b.address,b.hash_value, b.sql_text from v$session a, v$sqltext b, v$process p where p.spid = &spid and p.addr = a.paddr and a.STATUS = 'ACTIVE' and a.sql_address =b.address order by address, piece; 数据库无法连接 数据库无法连接,一般可能是如下原因造成: (1)数据库宕了 (2)监听异常 (3)数据库挂起 (4)归档目录满 (5)数据库或应用主机的网卡出现问题不能正常工作 (6)应用主机到数据库主机的网络出现问题。 1、数据库宕了 立即启动数据库。 2、监听异常 此时一般体现为: 监听进程占用CPU资源大; 监听日志异常。 此时,立即重启监听,监听重启一般能在1分钟之完成。 3、数据库挂起 立即重启数据库。 4、归档目录满 (1)在没有部署OGG数据同步的情况下,立即清理归档日志文件。

(2)如果部署了OGG数据同步,查看OGG正在读取的归档日志文件,立即 清理OGG不再需要的日志文件。 5、数据库或应用主机的网卡出现问题不能正常工作。 立即联系主机工程师处理。 6、应用主机到数据库主机的网络出现问题。 立即联系网络维护人员查看。 CRS/GI无法启动 对于10g及11gR1版本的CRS问题 1、进入/tmp目录下,看是否产生了crsctl.xxxxx文件 如果有的话,看文件容,一般会提示OCR无法访问,或者心跳IP无法 正常绑定等信息。 2、如果/tmp目录下没有crsctl.xxxxx文件 此时查看ocssd.log文件,看是否能从中得到有价值的信息。 可能的问题:网络心跳不通。 3、/tmp目录无crsctl.xxxxx且日志中没有报错信息,只有停CRS时的日志信 息。 此时可能是RAC两个节点对并发裸设备的访问有问题,此时考虑: (1)停掉两个节点的CRS。 (2)两个节点先同时去激活并发VG,然后再激活VG。 (3)重新启动CRS。 对于11gR2的GI问题 分析$GRID_HOME/log/nodename目录下的日志文件,看是否能从中找出无法启动的原因。常见问题: 1、心跳IP不同。 2、ASM实例无法启动。 对CRS的故障诊断和分析,参加本文档中RAC部分的MOS文档. 数据库响应慢

连接数据库出错处理办法

https://www.360docs.net/doc/428509528.html,没学好,又要学jsp了.... 1. 安装:SQL Server 2000 Driver for JDBC Service Pack 3 下载安装JDBC SP3 https://www.360docs.net/doc/428509528.html,/downloads/details.aspx?familyid=07287B11-0502-461 A-B138-2AA54BFDC03A&displaylang=en 里面的SetUp.exe 按照提示安装可以了.成功后有三个文件要使用: c:\program files\Microsoft SQL Server 2000 Driver for JDBC\lib\msbase.jar c:\program files\Microsoft SQL Server 2000 Driver for JDBC\lib\msutil.jar c:\program files\Microsoft SQL Server 2000 Driver for JDBC\lib\mssqlserver.jar 2.测试代码 新建类文件Connect.java. package test; import java.*; import java.sql.Driver; public class Connect{ private java.sql.Connection con = null; private final String url = "jdbc:m icrosoft:sqlserver://"; private final String serverName= "localhost"; private final String port Number = "1433"; private final String databaseName= "DBtest"; private final String userName = "sa"; private final String password = "123456"; // Informs the driver to use server a side-cursor, // which permits m ore than one active statem ent // on a connection. private final String selectMethod = "cursor"; // Constructor public Connect(){} private String getConnectionUrl(){ return

Mysql服务无法启动的1067错误解决

无论安装何版本的mysql,在管理工具的服务中启动mysql服务时都会在中途报错。内容为:在本地计算机无法启动mysql服务错误1067:进程意外中止。 经过多方求教,得解决方法如下 查找系统(后来验证应该为windows目录)目录下的my.ini文件,编辑内容(如果没有该文件,则新建一个),至少包含basedir,datadir这两个基本的配置。 [mysqld] # set basedir to installation path, e.g., c:/mysql # 设置为MYSQL的安装目录 basedir=D:/www/WebServer/MySQL # set datadir to location of data directory, # e.g., c:/mysql/data or d:/mydata/data # 设置为MYSQL的数据目录 datadir=D:/www/WebServer/MySQL/data 另外,要主意 [WinMySQLadmin] Server=D:/www/WebServer/MySQL/bin/mysqld-nt.exe user=root password=xxxxxxxx #以上是设置WinMySQLadmin的配置 [Client] user=root password=xxxxxxxx hehe~ :) 解决了 my.ini 文件内容如下.我自己改的,就好了,嘿嘿 [mysqld] # set basedir to installation path, e.g., D:/mysql # 设置为MYSQL的安装目录 basedir=D:/mysql # set datadir to location of data directory, # e.g., d:/mysql/data or d:/mysql/mydata/data

usb打不开解决方法

为什么U盘插上USB口后,电脑不认,没有出现“可移动磁盘”? 原因可能有: USB口接触不好 处理办法:拔下,等十秒钟再插上USB口,使接触完好; 电脑的USB功能没有打开, 处理办法:启动电脑进去BIOS设定,找到USB功能选项,选“使能”; 为什么启动型优盘在我的电脑上无法实现启动 可能是主板型号不支持 如何判断一块主板是否支持闪存盘启动系统 启动型优盘是采用模拟USB软驱和USB硬盘的方式启动电脑的。只要电脑主板支持USB设备启动,即BIOS的启动选项中有USB-FDD、USB-HDD或是其它类似的选项,就可以使用启动型优盘启动电脑。 第一次在电脑上使用优盘,未出现提示发现新硬件的窗口,驱动程序无法安装 原因可能是: 1、主板usb controller未启用, 解决办法: 在电脑主板BIOS中启用此功能 2、usb controller已经启用但运行不正常, 解决办法: 在设备管理器中删除”通用串行控制器”下的相关设备并刷新。 3、优盘被电脑识别异常,在设备管理器中表现为带有黄色?或!的”其它设备”或”未知设备”, 解决办法: 删除此设备并刷新 大容量的U盘(例如兼具MP3播放器或录音功能的U盘)或移动硬盘在电脑上无法正常使用,虽然系统提示找到了未知的USB设备,但无法正确识别U盘或移动硬盘 原因可能是: 1. USB接口供电不足: 系统为每个USB接口分配了500mA的最大输出电流,一般的U盘只需要100mA的工作电流,因此在使用过程中不会出现什么问题。大多数移动硬盘所使用的是普通的英寸硬盘,其工作电流介于500mA~1000mA之间,此时假如仅仅通过USB接口供电,当系统中并无其他USB设备时,那么还是可以勉强使用的,但如果电压不稳的话,就随时可能出现供电不足的问题。特别是使用支持USB 的移动硬盘时,情况最为严重。另外,如果你的笔记本电脑使用电池供电,那么USB接口所分配的电量就更小了。 2.使用了外接的USB 扩展卡: 在笔记本电脑中使用USB 的U盘或移动硬盘时,如果笔记本电脑不支持USB 技术,一般必须通过PCMCIA卡转USB 的扩展卡来间接实现支持,这些扩展卡基本上都采用NEC公司的D720100AGM USB控制芯片,少则提供两个USB 接口,多则提供五个USB 接口,对一般用户而言足够使用了。由于PCMICA接口提供的电源功率比板载USB 接口要小,这样就会由于供电不足而导致移动硬盘工作的出现问题。 解决方案:

USB简介及USB设备常见问题的解决方案

USB通用串行总线(英文:Universal Serial Bus,简称USB)是连接外部装置的一个串口汇流排标准,在计算机上使用广泛,但也可以用在机顶盒和游戏机上,补充标准On-The-Go(OTG)使其能够用于在便携装置之间直接交换资料。USB是一个外部总线标准,用于规范电脑与外部设备的连接和通讯。USB接口支持设备的即插即用和热插拔功能。USB接口可用于连接多达127种外设,如鼠标、调制解调器和键盘等。USB是在1994年底由英特尔、康柏、IBM、Microsoft等多家公司联合提出的,自1996年推出后,已成功替代串口和并口,并成为当今个人电脑和大量智能设备的必配的接口之一。从1994年11月11日发表了USB V0.7版本以后,USB版本经历了多年的发展,到现在已经发展为3.0版本。(摘自百度百科) 传输速率 在了解USB的传输速率之前先来看一下几个常见单位 1字节=1B(Byte)=8位=8b(bit) 1KB(Kilobyte 千字节)=1024B, 1MB(Megabyte 兆字节简称“兆”)=1024KB, 1GB(Gigabyte 吉字节又称“千兆”)=1024MB, 1TB(Trillionbyte 万亿字节太字节)=1024GB, 其中1024=2^10( 2 的10次方),后面还有不再多说。看图 . b/s 一般表示位传输速度,bps 表示位传输速率,数值上相等。B/s与b/s,BPS(字节每秒)与bps(位每秒)不能混淆。1MB/s(兆字节/秒)=8Mbps(兆位/秒), 12Mbps=1.5MB/s,大部分MP3为此类接口类型。USB 1.0是在1996年出现的,速度只有1.5Mb/s(位每秒); 1998年升级为USB 1.1,速度也大大提升到12Mb/s,在部分旧设备上还能看到这种标准的接口。USB1.1是较为普遍的USB规范,其高速方式的

Oracle数据库常见异常的诊断方法

目录 第1章 Oracle数据库常见问题诊断方法 (1) 1.1 常见错误篇 (1) 1.1.1 ORA-12571、ORA-03113、ORA-03114、ORA-01041 (1) 1.1.2 ORA-01000 (1) 1.1.3 ORA-01545 (2) 1.1.4 ORA-0165x (2) 1.1.5 ORA-01555 (3) 1.1.6 ORA-04031 (3) 1.1.7 ORA-04091 (3) 1.1.8 ORA-01242、ORA-01113 (4) 1.2 内部错误篇 (4) 1.2.1 ORA-00600【12330】错误 (4) 1.2.2 ORA-00604【xxx】错误 (5) 1.2.3 ORA-00600【3339】错误 (5) 1.2.4 ORA-00600【13004】错误 (5) 1.3 分布式事务篇 (6) 1.3.1 诊断分布式事务 (6) 1.3.2 检查其它节点的事务(DBA_2PC_NEIGHBORS) (6) 1.3.3 通过DBA_2PC_PENDING字典表检查事务的状态 (6) 1.3.4 检查处理结果 (7) 1.3.5 COMMIT FORCE或ROLLBACK FORCE命令 (7) 1.4 OPS或RAC篇 (8) 1.4.1 准备工作 (8) 1.4.2 紧急情况下的状态备份 (8) 1.4.3 OPS设计、配置准则 (9) 1.4.4 OPS常见问题 (9) 1.4.5 诊断分析步骤 (9) 1.5 非OPS篇 (18) 1.5.1 ORACLE数据库系统常见问题:空间方面问题 (18) 1.5.2 ORACLE数据库系统常见问题:性能方面问题 (18) 1.5.3 ORACLE数据库系统常见问题:锁争用方面问题 (19) 1.5.4 ORACLE数据库系统常见问题:内存方面问题 (20) 1.5.5 ORACLE问题分析脚本 (20) 1.5.6 SQL*NET篇 (24) 1.5.7 TNS-12154 Error 或ORA-12154 (24) 1.5.8 NL-00462 Error 或ORA-00462 (25) 1.5.9 NL-00405 Error 或ORA-00405 (26)

mysqlerror2003

安装ipv6后再安装mysql配置时提示:error nr.2003 can't connect to mysql server on 'localhost'(10061) 说来惭愧啊,其实前段时间遇到过此问题,可是后来稀里糊涂的就解决了,详情可以找找我前面发表过的文章.这不这次就又遇到了, error nr.2003 can't connect to mysql server on 'localhost'(10061) 还是解决不了,学习这事会就是会,不会就是不会啊............感触颇深. 苍天不负有心人啊,最后还是让我找到了解决方法. 首现ping localhost 出现了下面的截图,有没有感到奇怪呢?为什么出现的地址不是 127.0.0.1 前端时间研究利用IPv6登个国外网站什么的,就给自己电脑安装了ipv6(我的电脑是xp),唉你猜对了,问题就出在这ipv6上. 关闭它! 用下面附录的方法可以关闭ipv6(win7) 也可以用修改HOST文件的方式使localhost与127.0.0.1等同,如下: 从 WinVista 和 Win7 的 hosts 文件里可以看出,localhost 并没有直接被解析为 127.0.0.1 ,而是 DNS 将根据当前连接的协议来自动选择将其解析为 v4 地址还是 v6 地址: # localhost name resolution is handled within DNS itself. # 127.0.0.1 localhost # ::1 localhost 而在此我们为了解决 localhost 的连接问题,可以给 host 加上这么一条,以告诉系统强制使用IPv4 连接。直接在 hosts 文件的末尾加上 127.0.0.1 localhost 这一条语句(需要修改文件权限)。再次 Ping 一下 localhost: 正在 Ping WinSeven-PC [127.0.0.1] 具有 32 字节的数据: 来自 127.0.0.1 的回复: 字节=32 时间<1ms TTL=128 来自 127.0.0.1 的回复: 字节=32 时间<1ms TTL=128

(完整版)如何安全弹出您的USB设备

如何安全弹出您的USB设备 2007-03-09 19:30 症状一 有时候 Explorer 进程因发生错误关闭,导致系统托盘的USB设备图标丢失的时候。怎样安全把 USB 设备弹出? 解决方法一:适用U盘:在“资源管理器”里面,右键点击U盘,选择“弹出”。 解决方法二:点击“开始→ 运行”,输入以下字符并回车,就可以看到“安全删除硬件”窗口弹出了: %windir%\system32\rundll32.exe shell32.dll,Control_RunDLL hotplug.dll 症状二 U盘或移动硬盘接在弹出时出现:“无法停止通用卷....” 注销后也无法停止。 情况分析: 首先,可能是杀毒软件的实时监控(这一点是网友们首先想到的原因,但虫子还未验证,欢迎大家提出异议^_^); 其次,可能是硬盘分区的时候使用了NTFS格式,并且使用了文件压缩,这可能要使用系统文件才能实现; 第三,可能是由于进行了大容量文件的剪切、删除、复制等操作,在系统中存留了缓存或临时文件,造成无法停止; 第四,考虑是不是供电不足,把两条USB线都连接上试试。 解决方法一: 1、双击任务栏上的安全删除硬件图标,出现图1所示“安全删除硬件”画面; 2、按下Ctrl + Alt + Del 组合键调出“任务管理器”; 3、结束其中的explorer.exe进程,此时桌面上的“任务栏”消失; 4、单击“安全删除硬件”对话框的“停止”键,当系统提示“安全地移除硬件”文字提示时,即可拔下USB插头;

5、然后在“任务管理器”菜单上依次点击“文件(F)”→“新建任务(运行...)” ,输入“explorer.exe”,然后回车,此时任务栏出现。 解决方法二: 开始==>运行==>services.msc 打开“服务”停用shell hardware detection 项,移动设备将不再自动播放,也可以解决无法删除硬件的问题。 解决方法三: 在设备管理器中的“磁盘驱动器”(U盘的找USB Flash Drive USB Device 不同品牌的闪存名称可能不同)找到移动硬盘名称列表,双击打开“属性”对话框。切换到“策略”选项卡,选中“为快速删除而优化”,单击“确定”退出。此时可能会要求系统重新启动。 以后不用理会系统托盘中的“安全删除硬件”图标,只要没有对闪存进行数据读写操作(即闪存的指示灯不闪动),就可以直接将闪存从USB 接口拔下来了。 虫子的总结: 此总结纯属虫子个人看法,因为USB设备设计初衷就是热拔插,这意味着不必非要进行安全弹出,只要移动设备的工作状态指示灯不闪,未进行读写操作,直接拔出即可。我用着的这个U盘经常这样拔,已经用了两三年了,容量是小点,但也从没有遇见过数据丢失的情况,也没因为乱拔而损坏。 以上分析和解决方法,大家仁者见仁,智者见智,因为这种无法弹出的情况会因机器或设备而异,虫子提供的仅仅是一个方法和思想,还希望大家根据实际情况来解决。

速达软件常见问题处理方法 解决方法

速达软件问题处理锦集----安装与启动 1、在安装MSDE数据库时,出现安装程序倒退的情况 产品名称:MSDE 版本信息:速达所有版本 模块名称:这是以前装过SQL Server数据库或MSDE数据库,没有卸载干净. 解决方案:解决办法重装操作系统 2、安装MSDE数据库时,系统出现“读取文件C:\program files\Microsoft sql sever\mssql\data\msdbata.mdf时出错”的提示信息。 产品名称:MSDE 版本信息:SQL SERVER2000 模块名称:安装 解决方法:退出安装程序,删除C盘里SQL Server文件夹,删除后再重新安装数据库。 3、安装MSDE数据库时,提示安装程序被挂起。 产品名称:MSDE 版本信息:SQL SERVER2000 模块名称:安装 解决方法:重新启动电脑。 4、打开软件时,系统出现以下的提示信息:“未设置登录账号和密码”,请问如何解决? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:系统维护 解决方案:1、以管理员身份登录;2、关闭防火墙; 3、再次登陆时会提示输入用户名与密码; 4、到微软网站下载MSDE最新版本。 5、在启用过程中提示:“数据库用户及密码错误”? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:数据库 解决方案:1、确定是否在数据库中设置了用户名和密码,准确录入;2、重装SQL-SERVER个人版。 3、在SQL-Server 2000中,打开企业管理器,重新注册一个数据库用户组。 6、登陆软件时,系统提示“无法连接数据库,请检查SQL服务器或网络连接是否正常”,请问如何解决? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:日常维护 解决方法:在控制面板添加硬件中添加虚拟网卡。(进入添加硬件向导,添加新硬件,检测过后选择添加新设备,再选择从列表中选取,选中网卡下一步,查找制造商Microsoft有一个设备Microsoft Loopback Adapter,选中它,安装完成后,查看硬件管理器,会多出一个新网卡,这就是虚拟网卡。) 7、启动服务器时提示:通常每个套节字地址(协议网络地址/端口)只允许使用一次,无法登陆,如何解决? 产品名称:速达所有产品 版本信息:速达所有产品 模块名称:服务器设置 解决方案:1、注意电脑上有没有在已打开服务器情况下再进行多次打开服务器。 2、客户多次点击软件造成的,重新启动电脑,双击软件即可; 3、注意我们所有速达3000系列都用3001端口,我们的7000与5000系列都用5001端口在所有默认设置下,不能打开多个速达3000服务器,也不能

mysql卸载重新安装文档

卸载mysql报错解决方法1 dpkg: error processing mysql-server (--configure): dependency problems - leaving unconfigured start: Job failed to start invoke-rc.d: initscript mysql, action "start" failed. dpkg: error processing mysql-server-5.5 (--configure): subprocess installed post-installation script returned error exit status 1 dpkg: dependency problems prevent configuration of mysql-server: mysql-server depends on mysql-server-5.5; however: Package mysql-server-5.5 is not configured yet. dpkg: error processing mysql-server (--configure): dependency problems - leaving unconfigured No apport report written because the error message indicates its a followup error from a previou s failure. Errors were encountered while proces sing: mysql-server-5.5 mysql-server E: Sub-process /usr/bin/dpkg returned an error code (1) 解决方法: 删除mysql前先删除一下 /var/lib/mysql 还有 /etc/mysql sudo rm /var/lib/mysql/ -R sudo rm /etc/mysql/ -R sudo apt-get autoremove mysql* --purge sudo apt-get remove apparmor sudo apt-get install mysql-server mysql-common UBUNTU 彻底删除MYSQL 然后重装MYSQL 删除mysql sudo apt-get autoremove --purge mysql-server-5.0 sudo apt-get remove mysql-server sudo apt-get autoremovemysql-server sudo apt-get remove mysql-common //这个很重要 上面的其实有一些是多余的。 清理残留数据 dpkg -l |grep ^rc|awk '{print $2}' |sudoxargsdpkg -P

win7USB安装出现错误解决

在32位WIN7电脑上装64位系统出现错误如何做file copied successfully however we were unable to run boot 转自: https://www.360docs.net/doc/428509528.html,/wenglsqs/blog/item/42c8d6cf510fb026f9dc61bd.html ========================================= 在32位电脑上,用Windows 7 USB DVD Download Tool创建64位win7系统。(提供32位bootsect下载) 第一张图片呈示如下: Files copied successfully. However, we were unable to run bootsect to make the usb device bootable. If you need assistence with bootsect, please click the "Online Help" link above for more information. 文件复制成功。然而,我们无法运行bootsect,使USB设备启动。如果您需要bootsect assistence,请点击查看详细信息的“在线帮助”链接。 中间解密: 第一步:用cn_windows_7_ultimate_x86_dvd_x15-65907\boot\bootsect。文件bootsect即是“32位ISO”大小95KB。 第二步:复制bootsect到 C:\Users\username\AppData\Local\Apps\Windows 7 USB DVD Download Tool。返回到Windows 7的USB DVD工具来创建可引导的USB 设备。

Mysql常见错误提示及解决方法

Mysql常见错误提示及解决方法 130 :文件格式不正确。(还不是很清楚错误的状况) 145 :文件无法打开。 1005:创建表失败。 1006:创建数据库失败。 1007:数据库已存在,创建数据库失败。 1008:数据库不存在,删除数据库失败。 1009:不能删除数据库文件导致删除数据库失败。 1010:不能删除数据目录导致删除数据库失败。 1011:删除数据库文件失败。 1012:不能读取系统表中的记录。 1016:文件无法打开,使用后台修复或者使用phpmyadmin 进行修复。 Quote: 开始=>所有程序=>附件=>命令提示符 输入mysql 所在硬盘盘符 cd mysql 所在目录 cd bin 输入myisamchk -f D:usr/local/mysql/data/bbs/PW_members.MYI ps : D:usr/local/mysql/data/bbs 是你论坛数据库的路径 -f 根据具体情况选择,一般也可以选择-r 注意你的系统C盘或放数据库的硬盘空间是否足够,一般小于1G 很容易出现错误。或用mysqlcheck命令进行修复。具体的方法:利用命令行进入mysql/bin目录,执行mysqlcheck -o -r phpwind -uroot -p 其中phpwind是你数据库的名称,root是你的数据库用户名,然后会提示你输入密码。然后就会修复你的数据库。 1017:服务器非法关机,导致该文件损坏。 1020:记录已被其他用户修改。 1021:硬盘剩余空间不足,请加大硬盘可用空间。 1022:关键字重复,更改记录失败。

1023:关闭时发生错误。 1024:读文件错误。 1025:更改名字时发生错误。 1026:写文件错误。 1030:可能是服务器不稳定。(具体原因不是很清楚) 1032:记录不存在。 1036:数据表是只读的,不能对它进行修改。 1037:系统内存不足,请重启数据库或重启服务器。 1038:用于排序的内存不足,请增大排序缓冲区。 1040:已到达数据库的最大连接数,请加大数据库可用连接数。 Quote: 在my.ini 修改max_connections=100为max_connections=1000或更大,重启mysql 1041:系统内存不足。 1042:无效的主机名。 1043:无效连接。 1044:数据库用户权限不足,请联系空间商解决。 1045:数据库服务器/数据库用户名/数据库名/数据库密码错误,请联系空间商检查帐户。Quote: 方法:确保论坛data目录下的sql_config.php用户名与密码都正确.如果用户忘记了数据库的密码,可以按如下方式进行密码的修改: 如果MySQL 正在运行,首先停止。 启动MySQL :bin/safe_mysqld --skip-grant-tables & 就可以不需要密码就进入MySQL 了。 然后就是 >use mysql >update user set password=password("new_pass") where user="root"; >flush privileges; 1046:没有选择数据库。 1048:字段不能为空。

相关文档
最新文档