高精度高重频脉冲激光测距系统

高精度高重频脉冲激光测距系统
高精度高重频脉冲激光测距系统

第40卷第8期红外与激光工程2011年8月Vol.40No.8Infrared and Laser Engineering Aug.2011

高精度高重频脉冲激光测距系统

纪荣祎,赵长明,任学成

(北京理工大学光电学院,北京100081)

摘要:在三维激光扫描探测系统中,激光测距的测量重频和测量精度是影响整个系统性能的关键参数。介绍了三维激光扫描探测系统的工作特点,设计了一种以Nios II嵌入式软处理器为核心的高重频、高精度脉冲激光测距系统。通过分析影响测量重频和测距精度的因素,采用双阈值时刻鉴别方法进行计时起止时刻的鉴别,使用TDC-GP2高精度时间间隔测量芯片进行精密计时,设计了基于Nios II嵌入式软处理器的计时控制系统以提高测量重频。实验结果表明:实现了测量重频为20000次/s、测距精度为3cm的激光测距。与传统的单片机控制的计时系统相比,该系统不仅测量重频和测量精度高,且具有更好的可扩展性和灵活性。

关键词:脉冲激光测距;精密时间测量;三维激光扫描;Nios II

中图分类号:TN247文献标志码:A文章编号:1007-2276(2011)08-1461-04

High precision and high frequency pulse laser ranging system

Ji Rongyi,Zhao Changming,Ren Xuecheng

(School of Photoelectronics,Beijing Institute of Technology,Beijing100081,China)

Abstract:In three-dimensional(3D)laser scanning detection system,the measurement repetition rate and measurement precision of laser ranging are the key parameters affecting the performance of the whole system.The work characteristics of3D laser scanning detection system were introduced,and a high repetition rate and high measurement precision pulse laser ranging system based on the Nios II soft-core was designed.According to the analysis of the factors which affected the repetition rate and precision of range measure,the double-threshold time discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2high-precision interval measuring chip was used to achieve high precision on time measure.In addition,the time measure control system based on the Nios II soft-core was designed to improve the measurement repetition rate.Experimental results show that the measurement repetition rate of20000/s and the ranging precision of±3cm are https://www.360docs.net/doc/458271273.html,pared with the traditional MCU time measure control system,the designed system owns the advantages of high repetition rate and high measurement precision,furthermore,it is more expandable and flexible.

Key words:pulse laser ranging;high precision time measure;3D laser scanning;Nios II

收稿日期:2010-12-18;修订日期:2011-01-17

基金项目:国防科技工业技术基础科研项目(J172009C001)

作者简介:纪荣祎(1984-),男,博士生,主要从事三维扫描激光探测系统的研究。Email:xiaoxiao8673@https://www.360docs.net/doc/458271273.html,。

导师简介:赵长明(1960-),男,教授,博士生导师,博士,主要从事新型激光器件与技术、光电子信息技术与系统方面的研究工作。

Email:zhaochm1@https://www.360docs.net/doc/458271273.html,

红外与激光工程第40卷

0引言

三维激光扫描是一种基于激光精密测距的主动

式三维信息获取技术,是获取空间数据的重要技术

手段。与传统的测量手段相比,它具有独特的优势:

数据获取速度快,实时性强;数据量大,精度较高;主动性强,能全天候工作;全数字特征,信息传输、处理容易。同时,三维激光扫描技术可以深入到恶劣的环境及空间中进行扫描操作,在工业、国防、医学等领域中广泛应用[1]。

三维激光扫描仪获取目标信息需要进行以下操作:在计算机的控制下,发射激光脉冲对三维物体的表面进行扫描测距,根据获得的距离点阵信息生成被测物体表面的三维图像,快速重构出目标的三维模型以及线、面、体、空间等各种制图数据。

三维激光扫描技术具有高精度测距和快速扫描的工作特点,需要对目标表面进行大量高精度的点测距工作。因此,高精度和高重频的激光测距技术的研究是开发三维激光扫描系统的关键。

1测距原理

脉冲激光测距利用测量脉冲激光的飞行时间来测量目标的距离,其原理如图1所示[2]。

图1脉冲激光测距系统简图

Fig.1Main configuration of pulse laser ranging system

图中,激光发射机向目标发射激光脉冲,同时由光学方式(探测发射的脉冲信号)或电学方式(LD驱动信号)确定发射时间,生成起始信号,开启TDC计时。探测器接收被目标反射回的激光脉冲,在接收通道生成停止信号,停止TDC计时。TDC模块测量起止信号的时间间隔t,可得目标距离R为:

R=1

2

ct(1)由公式式1可知,目标距离R的测量精度由时间间隔t的测量精度决定。

2系统组成

2.1系统整体设计

为了实现高精度和高重频的激光测距,文中设计了基于Nios II处理器的激光测距系统,其硬件结构如图2所示。

在Nios II控制系统中,由脉冲产生模块产生驱动脉冲信号,驱动脉冲发射机发射激光脉冲信号,同时,由驱动信号产生计时开始信号,启动TDC芯片开始计时。目标返回的脉冲回波信号由接收通道接收,经过放大和时刻鉴别,产生计时停止信号,结束时间间隔测量。Nios II控制系统的SPI接口模块控制计时芯片工作,读取计时数据并进行数据格式转换,并把处理过后的数据通过USB接口模块传递给上位PC机。

控制系统中使用的Nios II处理器是ALTERA 公司开发的基于SOPC嵌入式系统的32位RISC处

图2系统结构及Nios II内核设计框图

Fig.2System structure and kernel design of Nios II 1462

第8期

理器;选用ALTERA公司的Cyclone II EP2C8作为实现Nios II系统设计和生成的硬件芯片;利用SOPC Builder设计软件生成SOPC系统。

2.2高精度时间测量的实现

由脉冲激光测距原理可知,测距误差源于飞行时间的测量误差,飞行时间的测量是由起止信号控

制的时间间隔测量电路完成的。因此,减小起止时刻的鉴别误差和时间间隔测量误差,是提高测距精度的主要途径。

使用传统的前沿时刻鉴别法时,由于漂移效应,给前沿定时带来较大的定时误差[3]。降低鉴别阈值是减少漂移误差的有效措施,但鉴别阈值的减少会引起噪声误触发。为此,系统使用一种双阈值鉴别方法,如图3所示[4]。低阈值用来做定时鉴别,高阈值用来排除噪声信号。为了使高、低阈值鉴别出来的信号能产生正确的时刻鉴别信号,将低阈值鉴别输出信号延迟,使得在符合电路中,高阈值信号能“包住”低阈值信号,输出时刻鉴别信号。

图3双阈值鉴别方法原理图

Fig.3Principle of double-threshold leading edge discriminator

利用双阈值时刻鉴别方法,选择合适的高、低阈值,可以最大限度地消除幅度效应引起的时间游动和噪声引起的时间抖动。通过实验,当前放输出信号幅度为3.2~0.5V时,设置高阈值为400mV,低阈值为80mV,得到时刻鉴别的漂移误差和时间抖动误差约为70ps。

实现时间间隔测量的方法主要有脉冲计数法、时间-模拟量转化法和插入法[5]。插入法的时间间隔测量精度最高,其中,延迟线插入法是通过信号在延迟线上的固定时延实现时间间隔的精确测量,同时得到高测量精度和高线性,具有测量范围大、线性好、测量精度高以及测量速度快的优点,综合性能最好[6]。

TDC-GP2芯片是德国ACAM公司设计的高精度时间数字转换芯片,采用延迟线插入法技术,其主要构架如图4所示。

图4TDC-GP2芯片计时部分内部结构图

Fig.4Measurement unit framework of TDC-GP2

该芯片有两种测量模式:测量模式1的测量范围为3.5ns~1.8μs,两个Stop通道共用一个Start通道,每个通道的典型分辨率为65ps,可进行4次采样,均可选择上升沿或下降沿触发;测量模式2的测量范围为2×T ref~4ms,只有Stop1通道对应Start通道,典型分辨率为65ps,有3次采样能力,可选择上升沿或下降沿触发[7]。

综上所述,TDC-GP2芯片可实现分辨率为65ps 的时间间隔测量,是实现脉冲激光测距时间间隔测量的理想器件。

2.3高重频测距的实现

使用TDC-GP2进行激光脉冲测距时间间隔测量,需要通过SPI接口与TDC-GP2通讯,进行控制命令和计时数据的读写操作。由SPI接口的读写时序和计时测量时序可知,进行一次时间间隔测量,各步骤操作使用的时钟周期如图5所示。

图5TDC-GP2时间间隔测量工作流程

Fig.5Flow chart of timing measure by TDC-GP2

使用MSP430单片机作为控制器,通过SPI接口控制TDC-GP2计时,当主时钟Mclk为8MHz时,由图5可知,从初始化到数据读取,最少共需要83μs。而使用MSP430单片机通过串口与上位机进行数据传输时,串口最大波特率为115.2Kbps,则传输一次计时数据所需时间约为340μs。由以上分析可知,使用MSP430单片机控制TDC-GP2完成一次完整的测量时间最少为430μs,1s可测量约2000次,测量重频较低。

纪荣祎等:高精度高重频脉冲激光测距系统1463

红外与激光工程第40卷

使用Nios II控制系统进行计时控制,当系统时钟为50MHz时,SPI接口模块的传输波特率可达15Mbps;TDC-GP2的SPI接口读写传输的最大波特率为10Mbps,则SPI接口的传输速率可设置为10Mbps。根据时序分析计算,当SPI接口的传输速率为10Mbps 时,TDC-GP2的计时工作从初始化到完成测量并读取数据,最少需要10.76μs。同时,在50MHz系统时钟的驱动下,使用USB2.0接口进行数据上传,数据传输速率设置为20Mbps,则一次完整的测量所需时间约为20μs。留出一定的时间余量,则可实现20000次/s 的测量重频,既能满足TDC芯片与外界通信的时序要求,又可达到高重频测距的要求。

3实验与数据分析

使用VC++编写上位机控制软件,使用USB2.0接口传输控制命令和测量结果数据。由上位机软件定时控制测距系统的测量重频对1000ns的时间间隔进行测量,得到如下测量结果。测量重频:设置测量时间为1~6s,得到的测距次数如表1所示。计时误差:对计时结果进行统计计算,计时数据的平均值为1000074ps,标准差为87.42ps。由误差定义可得,系统误差为1000074ps-1000000ps=74ps;用所测数据减去平均值,计时数据的随机误差分布如图6所示。

表1计时测量次数

Tab.1Sample size of time measure

图6随机误差分布直方图

Fig.6Histogram of random error

图6中,随机误差大部分分布在-100~+100ps范围内,即在1000ns的时间间隔内,时间间隔测量系统的精度可达±100ps。

由实验可知,测距系统可实现±100ps的计时精度,对应3cm的测距精度,同时,可达到20000次/s 的测量重频。

4结论

根据三维激光扫描技术的工作特点,设计了一种基于Nios II处理器控制的脉冲激光测距系统。通过对起止时刻鉴别方法和时间间隔测量方法进行改进,使用双阈值时刻鉴别方法和TDC-GP2时间间隔测量芯片可获得±100ps的时间测量精度,对应3cm 的测距精度。同时,通过对计时过程的分析,使用Nios II处理器进行计时流程的控制,减小了单次测量的时间,提高了测量重频,可实现20000次/s的时间测量。实验结果表明:采用Nios II处理器系统控制TDC-GP2芯片进行时间间隔测量,不仅测量精度高,同时能够大大提高测量重频。高重频、高精度脉冲激光测距系统不仅可应用于三维激光扫描成像系统,而且可应用于脉冲激光测速等需要高重频、高精度距离测量的系统。

参考文献:

[1]Li Long.Study on test control technique and echo processing

methods for3-D laser scanner[D].Xi′an:Northwestern Polytechnic University,2004:3-4.(in Chinese)

[2]Paloj覿rvi P.Integrated electronic and optoelectronic circuits

and devices for pulsed time-of-flight laser rangefinding[D].

Finland:University of Oulu,2003.

[3]Lin Yingkan,Guo Ying,Huang Genghua,et al.Distance source

of laser range finder and its precision analysis[J].Infrared and Laser Engineering,2009,38(6):1089-1093.(in Chinese) [4]Guo Jianhua.The design and implement of BESIII TOF

readout electronic system[D].Anhui:University of Science

and Technology of China,2007:63-64.(in Chinese)

[5]Yang Chengwei,Chen Qiansong,Lin Yan,et al.Measurement

on time-interval in pulsed laser ranging and error analysis

[J].Infrared and Laser Engineering,2003,32(2):123-126.

(in Chinese)

[6]Liu Feng.Development and application of the pulsed LD

rangefinder[J].Infrared and Laser Engineering,2003,32

(2):118-122.(in Chinese)

[7]Zhang jianwu,Zhang Shuming.Applications of TDC-GP2in

laser range sensor[J].Instrument Technique and Sensor,2009, 8:74-76.(in Chinese)

Measure time/s123456 Sample size20002400036000580002100007120008 1464

激光脉冲的平均功率和功率

激光脉冲的平均功率和功率, 设脉冲激光器输出的单个脉冲持续时间(脉冲宽度)为:t,(实际为FWHM宽度) 单个脉冲的能量:E, 输出激光的脉冲重复周期为:T, 那么,激光脉冲的平均功率Pav = E/T,(即在一个重复周期内的单位时间输出的能量) 脉冲激光讲峰值功率(peak power)Ppk = E/t 能量密度=(单脉冲能量*所用频率)/光斑面积算 通常也用单位时间内的总能量除以光斑面积 峰值功率=脉冲能量除以脉宽 平均功率=脉冲能量*重复频率(每秒钟脉冲的个数) 脉冲激光器的能量换算 脉冲激光器的发射激光是不连续,一般以高重频脉冲间隔发射。发射能量以功的单位焦耳J) 计,即每次脉冲做功多少焦耳。 连续激光器发射的能量以功率单位瓦特(W)计量,即每秒钟做功多少焦耳,表示单位时间内 做功多少。 瓦和焦耳的关系:1W=1J/秒。 一台脉冲激光器,脉冲发射能量是1焦耳/次,脉冲频率是50Hz,则每秒钟发射激光50次,每秒钟内做功的平均功率为:50X 1焦耳=50焦耳,所以,平均功率就换算为50瓦。再举例 说明峰值功率的计算,一台绿光脉冲激光器,脉冲能量是0.14mJ/次,每次脉宽20 ns,脉冲 频率100kHz, 平均功率为:0.14mJ X 100k=14J/s=14W,即平均功率为14瓦;峰值功率是每次脉冲能量与脉宽之比,即 峰值功率:0.14mJ/20ns=7000W=7kW,峰值功率为7千瓦。 要想知道镜片的脉冲激光损伤阈值是否在承受极限内,既要计算脉冲激光的峰值功率,也要计算脉冲激光的平均功率,综合考虑。 如某ZnSe镜片的激光损伤阈值时是500MW/cm2,使用在一台脉冲激光器中,脉冲激光器的 脉冲能量是10J/cm2,脉宽10ns,频率50kHz。首先,计算平均功率:10J/cm2 X 50kHz =0.5MW/cm2 其次,再计算峰值功率:10J/cm2 / 10ns = 1000MW/cm2 从脉冲激光器的平均功率看,该镜片是能承受不被损伤的,但从脉冲激光器的峰值功率看, 是大于该镜片的激光损伤阈值的。所以,综合判断,该ZnSe镜片不宜用于此脉冲激光器。如果有条件,对脉冲激光器镜片,应当分别测试平均功率和峰值功率的激光损伤阈值。 Ave. Power :平均功率Pulse energy :脉冲能量Pulse Width :脉宽Peak Power:峰值功率Rep. Rate :脉冲频率ps:皮秒,10-12 S ns:纳秒,10-9S M: 兆, 106 J:焦耳W:瓦 氙灯作为激光设备一个常用光源,通常被人们也叫做激光氙灯、脉冲氙灯。氙灯是一 种填充氙气的光电管或闪光电灯。氙气化学性质不活泼,不能燃烧,也不助燃。是天然的稀

日本尼康激光测距仪1200S中文说明书和操作指南

L ASER 1200S C OMPACT R ANGEFINDER 激光测距仪 使用说明书 ——为了得到最佳性能和最长的使用寿命,使用前请仔细阅读此说明 【生产商】 ◆日本尼康 【主要特点】 ◆ 利用红外激光进行简单、快速的距离量测,并以数字形式显示 ◆适合各种条件的4种目标模式的选择,加上观测不同目标的快速扫描模式,牢固,轻巧的设计 ◆从仪器至目标的可量测距离:10--1100m (Laser1200S ),好的反射目标可测得更远 【量测模式】 有4种目标模式加一种扫描模式可适用于各种情况。只要按Mode 键即可在仪器的视场中选择模式。

【目标模式】 ◆标准模式(无指示器)用于典型的距离和中等的反射目标 ◆反射模式(REFL)用于高反射目标(反射器、停止标记等) ◆扫描模式(SCAN)当不同的目标扫描时,并开关3秒钟调用此功能 【技术指标】 规格Laser1200S; 放大率7 X ; 有效孔径25 mm; 视场5°; 瞳孔3.6 mm; 眼调节18 .6mm; 距离显示在LCD视场中显示数字; 量测精度± 0.5m; 量测范围10-1100 m (11-1200yd.); 照准器调节±4dpt; 电源CR2锂电池(DC3V)电源自动关闭功能(8秒后); 尺寸(L×W×H)145 x 47 x 82mm; 重量280g(包括电池); 仪器准备: 拧下仪器底部螺钮——》打开电池后盖——》装入CR2电池(注意)极性——》旋上电池后盖。

常见故障的排除: 仪器没有显示 ——压下发射按纽; ——如果有必要,请更换电池; 转换测量目标时没有清除上一次的测量值 ——上一次测量值不需清除,只需把十字叉对准新的目标,按下发射按纽并保持,直到出现测量值。 光学系统中出现黑点 ——是正常情况,在加工过程中无法完全消除。 无法得到测量值 ——确保LCD有显示 ——确保压下发射按纽 ——确保没有任何物体遮住目镜 ——确保压下发射按纽时仪器稳定 ——低反射率的目标要扫描其表面以找到反射率比较高的点。按住发射按纽,使十字叉在待测物体表面移动,LCD显示的待测物体信号比较强时,把仪器固定在这个位置,按住发射按纽,直到测量值出现 ——确保模式选择正确

高精度高重频脉冲激光测距系统

第40卷第8期红外与激光工程2011年8月Vol.40No.8Infrared and Laser Engineering Aug.2011 高精度高重频脉冲激光测距系统 纪荣祎,赵长明,任学成 (北京理工大学光电学院,北京100081) 摘要:在三维激光扫描探测系统中,激光测距的测量重频和测量精度是影响整个系统性能的关键参数。介绍了三维激光扫描探测系统的工作特点,设计了一种以Nios II嵌入式软处理器为核心的高重频、高精度脉冲激光测距系统。通过分析影响测量重频和测距精度的因素,采用双阈值时刻鉴别方法进行计时起止时刻的鉴别,使用TDC-GP2高精度时间间隔测量芯片进行精密计时,设计了基于Nios II嵌入式软处理器的计时控制系统以提高测量重频。实验结果表明:实现了测量重频为20000次/s、测距精度为3cm的激光测距。与传统的单片机控制的计时系统相比,该系统不仅测量重频和测量精度高,且具有更好的可扩展性和灵活性。 关键词:脉冲激光测距;精密时间测量;三维激光扫描;Nios II 中图分类号:TN247文献标志码:A文章编号:1007-2276(2011)08-1461-04 High precision and high frequency pulse laser ranging system Ji Rongyi,Zhao Changming,Ren Xuecheng (School of Photoelectronics,Beijing Institute of Technology,Beijing100081,China) Abstract:In three-dimensional(3D)laser scanning detection system,the measurement repetition rate and measurement precision of laser ranging are the key parameters affecting the performance of the whole system.The work characteristics of3D laser scanning detection system were introduced,and a high repetition rate and high measurement precision pulse laser ranging system based on the Nios II soft-core was designed.According to the analysis of the factors which affected the repetition rate and precision of range measure,the double-threshold time discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2high-precision interval measuring chip was used to achieve high precision on time measure.In addition,the time measure control system based on the Nios II soft-core was designed to improve the measurement repetition rate.Experimental results show that the measurement repetition rate of20000/s and the ranging precision of±3cm are https://www.360docs.net/doc/458271273.html,pared with the traditional MCU time measure control system,the designed system owns the advantages of high repetition rate and high measurement precision,furthermore,it is more expandable and flexible. Key words:pulse laser ranging;high precision time measure;3D laser scanning;Nios II 收稿日期:2010-12-18;修订日期:2011-01-17 基金项目:国防科技工业技术基础科研项目(J172009C001) 作者简介:纪荣祎(1984-),男,博士生,主要从事三维扫描激光探测系统的研究。Email:xiaoxiao8673@https://www.360docs.net/doc/458271273.html,。 导师简介:赵长明(1960-),男,教授,博士生导师,博士,主要从事新型激光器件与技术、光电子信息技术与系统方面的研究工作。 Email:zhaochm1@https://www.360docs.net/doc/458271273.html,

高重频双波长复合干扰激光器设计

高重频双波长复合干扰激光器设计* 叶庆1,范一松1 2,王磊1,卞进田1 (1. 国防科技大学 脉冲功率激光技术国家重点实验室 安徽 合肥 230037;2.中国科学院安徽光学精密机械研究所 安徽光子器件与材料省级实验室 安徽 合肥 230031) 摘要:为解决基频光高重频与倍频光高平均功率之间的矛盾,设计了一台干扰用高重频双波长复合输出激光器。静态仿真了泵浦源效率、激光晶体受热和受力分布、激光高斯模式特征,得到了该激光器的复合输出特性。动态仿真调Q 频率、倍频晶体长度对复合输出的影响以及分析倍频晶体热效应,发现在泵浦功率和谐振腔结构不变的前提下,需先满足基频光高重频工作,再优化倍频晶体长度和控制倍频晶体温度可提高倍频光的输出功率。按上述仿真结论开展验证实验表明:当KTP 晶体长度为12mm ,输出镜透过率为10%,重复频率为50kHz 时,设计的激光器基频光平均功率为18.98W ,倍频光平均功率为2.22W ,与仿真结论一致。 关键词:固体激光器;双波长复合输出;高重频;仿真与实验 中图分类号:TN242 文献标志码:A 文章编号: Design of the Dual-wavelength Composite Jamming Laser with High-repetitive Frequency YE Qing 1, FAN Yisong 1 2, WANG Lei 1, BIAN Jintian 1 (1. State Key Laboratory of pulsed power laser technology, National University of Defense Technology, Hefei 230037, China ;2.Anhui Provincial Key Laboratory of Photonic Devices and Materials, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China) Abstract: In order to solve the contradiction between high repetition rate of fundamental wave (FW) and high average power of second-harmonic wave (SHW), a new 1064nm/532nm dual-wavelength composite jamming laser with high-repetitive frequency was designed. Firstly, the composite output characteristics of the laser were obtained by the static analysis of t he pump source’s efficiency, heat and force distribution of crystal, and the Gauss mode of laser. Then, the influence on the dual-wavelength composite output was analyzed by changing the Q-switching frequency, the length of the second harmonic generation (SHG) crystal and by simulating the thermal effect of SHG crystal. It is found that the high frequency of FW should be satisfied first, and the output power of SHW can be improved by optimizing the length of the SHG crystal and controlling the temperature of SHG crystal under the condition of the constant pumping power and the structure of the resonator. Finally, the simulation conclusion was verified by experiment. The experimental results show that when the length of KTP crystal is chosen as 12mm, the transmissivity of the output mirror is fixed to 10%, and the Q-switching frequency is selected as 50KHz, the average output power of the FW is 18.98W, and the average power of the output of SHW is 2.22W. Keywords: solid-state laser; dual-wavelength composite output; high-repetitive frequency; simulation and experiment *收稿日期:2018-01-15 基金项目:脉冲功率激光技术国家重点实验室主任基金资助项目(SKL2015ZR01) 作者简介:叶庆(1981-),男,四川泸州人,博士,助理研究员,E-mail :yeqing0518@https://www.360docs.net/doc/458271273.html, 范一松(通信作者),男,安徽萧县人,硕士,工程师,E-mail :fan_ys01@https://www.360docs.net/doc/458271273.html,. 1064nm 和532nm 的双波长全固态激光器在激光清洗、激光医疗、激光探测等领域具有重要的应用价值[1-3]。不同的应用领域对激光器的性能指标要求不同,在激光对抗领域首先需要两路激光同时输出,从而减少干扰激光器的数量以提高设备的紧凑性[4],其次需要532nm 倍频激光平均功率尽可能大,以饱和干扰电视成像侦察与制导系统,1064nm 基频激光频率应尽可能高,以对抗基于波门识别原理的激光测距或半主动制导系统[5-7]。

激光测距仪操作规程

激光测距仪操作规 程

1.使用方法触按电源开关,接通电源,“电源、测试指示灯”为绿色。触按档位选择开关,选择适合的档位。 2.将仪表测量端子的两个电流输出端子用两根测试线接到被测导体的两个端子,两个电压输入端子也接到被测导体的两个端子。 3. 如图所示,电压端子应位于电流端子的内侧,并尽量靠近被测试品,以减少引线电阻引入的误差。 4.接线完毕后,触按一下 TESTE 键,“电源、测试指示灯”为红色,显示屏显示的值即为测得的电阻值。 5.当被测导体开路或阻值大于选定量程时, 显示屏首位显示“1”,后三位数字熄灭。 6.注意事项 a)本仪表使用6 节1.5V(LR6,AA)电池供电。当显示屏出现欠压符号“”时,请更换电池,以保障得到正确的试值。换下的旧电池请勿乱扔,以免造成污染。B)仪器应避免受潮、雨淋、跌落、暴晒等。

1.目的: 建立超声波测厚仪标准操作规程。 2.适用范围: 试验室所有检验人员执行本规程,部门领导监督,检查本规程的执行。 一、操作规程 1、机器校准 仪器壳下方有一个厚度为4mm的试块,按“菜单”键进入菜单,经过“上下”箭头选择“声速”,在选择“声速设置”,把声速设置为5920m/s,并在试块上涂抹耦合剂,把探头放在试块中央轻轻压紧,按一下“下箭头”,能够看到仪器显示试块厚度为4.000mm,如果试块厚度测试值不为4.000mm请在进行校准,直到试块测量厚度为 4.000mm。仪器校准完成后即能够正常测量了。 2、测试块准备 准备50mm的测试医用消毒超声耦合剂样品三份,以备测试。 3、声速测试 将探头与已准备好的测试样品耦合,确保探头不晃动并耦合良好,此时能够看到显示屏上耦合标志。选择声速测试界面,输

自制低成本3D激光扫描测距仪(3D激光雷达)

来自CSK的低成本3D scanner。Very Impressive! 在开始介绍原理前,先给出一些扫描得到的3D模型以及演示视频,给大家一个直观的认识。视频链接 相关的图片: 扫描得到的房间一角(点击查看原始尺寸) 扫描的我(点击查看原始尺寸)

扫描仪实物 本文结构 1. 简单介绍了激光雷达产品的现状 2. 激光三角测距原理 3. 线状激光进行截面测距原理 4. 3D激光扫描仪的制作考虑 5. 参考文献 简介-激光扫描仪/雷达 这里所说的激光扫描测距仪的实质就是3D激光雷达。如上面视频中展现的那样,扫描仪可以获取各转角情况下目标物体扫描截面到扫描仪的距离,由于这类数据在可视化后看起来像是由很多小点组成的云团,因此常被称之为:点云(Point Clould)。 在获得扫描的点云后,可以在计算机中重现扫描物体/场景的三维信息。 这类设备往往用于如下几个方面: 1) 机器人定位导航 目前机器人的SLAM算法中最理想的设备仍旧是激光雷达(虽然目前可以使用kinect,但他无法再室外使用且精度相对较低)。机器人通过激光扫描得到的所处环境的2D/3D点云,从而可以进行诸如SLAM 等定位算法。确定自身在环境当中的位置以及同时创建出所处环境的地图。这也是我制作他的主要目的之一。 2) 零部件和物体的3D模型重建

3) 地图测绘 现状 目前市面上单点的激光测距仪已经比较常见,并且价格也相对低廉。但是它只能测量目标上特定点的距离。当然,如果将这类测距仪安装在一个旋转平台上,旋转扫描一周,就变成了2D激光雷达(LIDAR)。相比激光测距仪,市面上激光雷达产品的价格就要高许多: 图片: Hokuyo 2D激光雷达 上图为Hokuyo这家公司生产的2D激光雷达产品,这类产品的售价都是上万元的水平。其昂贵的原因之一在于他们往往采用了高速的光学振镜进行大角度范围(180-270)的激光扫描,并且测距使用了计算发射/反射激光束相位差的手段进行。当然他们的性能也是很强的,一 般扫描的频率都在10Hz以上,精度也在几个毫米的级别。 2D激光雷达使用单束点状激光进行扫描,因此只能采集一个截面的距离信息。如果要测量3D的数据,就需要使用如下2种方式进行扩充: 1. 采用线状激光器 2. 使用一个2D激光雷达扫描,同时在另一个轴进行旋转。从而扫描出3D信息。 第一种方式是改变激光器的输出模式,由原先的一个点变成一条线型光。扫描仪通过测量这束线型光在待测目标物体上的反射从而一次性获得一个扫描截面的数据。这样做的好处是扫描速度可以很快,精度也比较高。但缺点是由于激光变成了一条线段,其亮度(强度)将随着距离大幅衰减,因此测距范围很有限。对于近距离(<10m)的测距扫描而言,这种方式还是 很有效并且极具性价比的,本文介绍的激光雷达也使用这种方式,

激光测距仪使用教程

美国LaserCraft高精度激光测距仪-Contour XLRic型,这款激光测距仪是高精度和远量程的结合体,是目前市场性能最好的一款手持激光测量系统。它能成功地在保持良好精度的前提下测量以下目标到前所未有的距离:175米到电力线,400米到电线杆,800米到建筑物。同时,它是一款坚固防水的仪器,遇到下雨,下雪,大雾或沙尘暴天气时,您只把工作模式选择到“坏天气”模式,您的工作就不会受到任何影响。在坏天气下使用它,就如同在好天气下使用一样方便,好用。如果装配了三脚架,它就可以用来进行更远距离的精确测量和进行精密的倾斜测量。 Contour XLR采用最新激光技术,小巧、轻便、使用方便,可准确测量目标距离。有恶劣天气工作模式保证仪器在仪器在雨、雪、雾、沙尘暴天气条件下仍可可靠工作。仪器配备HUD显示器,可边瞄准边测量。是建筑结构规划等通用距离测量的得力仪器。最大测量距离1850米,精度0.1米。 Contour XLRi具有XLR系列的全部特点,同时增加360度倾角传感器。有六种工作模式,分别是距离、角度、水平距离、垂直距离、二点高度、三点高度。有串行口,可通过计算机或数据记录器记录数据。典型应用:矿山地形测量、森林资源调查、倾斜测量、高度测量、水平杆测量、塔高测量。 Contour XLRic将XLRi和GPS以及数据采集器结合起来,可测量不易达到目标的参数。内置软件可计算树高、倾斜、面积、周长、不见线的长度、水平距离等。XLRic内部有数字罗盘和倾角传感器,是测绘的得力仪器。

ContourMAX最大测量距离达到3000米,重仅1.6公斤,首/末目标可选,门控能力、恶劣天气模式、手持/平台安装可选。典型应用:火灾控制系统、遥测、GPS偏移测、航空测量等。和Contour 系列手持激光测量系统中的Contour XLRi比较起来,Contour XLR ic在内部又集成了一个高精度磁通量数字罗盘。配合高精度磁通量数字罗盘,XLR ic在功能就比XLR和XLRi多了不少。有了Contour XLRic,您就可以把它和您的GPS系统连接起来,去测量那些无法到达或不容易到达的地方的坐标信息,省时又省钱。或者您也可以使用它内置的软件计算:树高,倾斜度,面积,周长,空间线段的长度,水平距离,高差等等数据。由于Contour XLRic配置了数字罗盘和倾斜角度测量仪,所以它完全可以被看作是一个手持式全站仪,可以协助您进行测绘和测量工作。一级人眼安全的激光测距仪精确地向您报告以下测量数据:距离,方位,倾斜角。技术特点-测量距离到: 1850米;-测量精度达到:10厘米;-倾斜角度测量;-方位角测量;-周长测量;-面积测量;-电力线高度和垂度测量;- 3D空间尺寸测量;-连接GPS工作;-高度测量功能;-“点到点”斜距测量;-水平距离测量和垂直距离测量;-独特的坏天气模式:一般的测距仪在天气不好的情况下,测量的距离往往会大大缩短,甚至无法工作。Contour系列激光测距仪的“坏天气模式”消除了这种现象。当天气情况不好的时候,比如:多云,大雾,扬尘,潮湿等,启动该模式,测量起来就和好天气时测量一样轻松快速!工作模式(详细功能)模式一标准测量模式:该模式测量仪

脉冲激光器的能量换算-波长光电

脉冲激光器的能量换算 南京波长光电科技股份有限公司王国力 脉冲激光器的发射激光是不连续,一般以高重频脉冲间隔发射。发射能量以功的单位焦耳(J)计,即每次脉冲做功多少焦耳。 连续激光器发射的能量以功率单位瓦特(W)计量,即每秒钟做功多少焦耳,表示单位时间内做功多少。 瓦和焦耳的关系:1W=1J/秒。 一台脉冲激光器,脉冲发射能量是1焦耳/次,脉冲频率是50Hz,则每秒钟发射激光50次,每秒钟内做功的平均功率为:50X 1焦耳=50焦耳,所以,平均功率就换算为50瓦。 再举例说明峰值功率的计算,一台绿光脉冲激光器,脉冲能量是0.14mJ/次,每次脉宽20ns, 脉冲频率100kHz, 平均功率为:0.14mJ X 100k=14J/s=14W,即平均功率为14瓦; 峰值功率是每次脉冲能量与脉宽之比,即 峰值功率:0.14mJ/20ns=7000W=7kW, 峰值功率为7千瓦。 要想知道镜片的脉冲激光损伤阈值是否在承受极限内,既要计算脉冲激光的峰值功率,也要计算脉冲激光的平均功率,综合考虑。 如某ZnSe镜片的激光损伤阈值时是500MW/cm2, 使用在一台脉冲激光器中,脉冲激光器的脉冲能量是10J/cm2,脉宽10ns,频率50kHz。 首先,计算平均功率:10J/cm2 X 50kHz =0.5MW/cm2 其次,再计算峰值功率:10J/cm2 / 10ns = 1000MW/cm2 从脉冲激光器的平均功率看,该镜片是能承受不被损伤的,但从脉冲激光器的峰值功率看,是大于该镜片的激光损伤阈值的。所以,综合判断,该ZnSe 镜片不宜用于此脉冲激光器。 如果有条件,对脉冲激光器镜片,应当分别测试平均功率和峰值功率的激光损伤阈值。 Ave. Power :平均功率 Pulse energy :脉冲能量 Pulse Width:脉宽 Peak Power::峰值功率 Rep. Rate :脉冲频率 ps:皮秒,10-12 S ns:纳秒,10-9S M:兆,106 J:焦耳 W:瓦

激光扫描测量系统的应用及发展

激光扫描测量系统的应用及发展 发表时间:2019-08-13T17:07:08.937Z 来源:《防护工程》2019年9期作者:张帆 [导读] 随着激光扫描测量系统在理论算法和硬件需求方面的不断完善与发展,势必在相关应用领域内引起新一轮的技术革新,不难看出其应用前景将十分广阔。 身份证号码:13040419910120**** 摘要:激光扫描仪作为一种新的空间数据获取手段,可高速、高精度获取物体表面点云的三维坐标值和实体纹理信息。从激光扫描测量系统的工作原理、激光扫描仪的分类、激光扫描测量系统的应用领域出发,阐述了激光扫描测量系统的应用现状,并指出该技术的未来发展趋势。 关键词:激光扫描测量:测量系统;应用发展 激光扫描测量系统通过后处理软件对采集的点云数据或者影像数据进行处理,进而转换成空间坐标系中的位置坐标或模型,并可以以多种不同的格式输出,以提供满足空间信息数据库建库的数据源和不同行业应用的需要。是集成了多种新技术的新型空间信息数据获取的手段与工具。激光扫描测量系统是继全站仪和GNSS之后,测绘领域又一次技术新突破。作为一种新的数据获取手段,以其非接触性、高效率、精确、高时效性和可获得大量测量目标物的三维坐标数据的优势广泛应用于各个研究领域,克服了传统测量技术的局限性,在国内外都有很好的发展和应用。 一、激光扫描测量系统概述 1.激光扫描测量技术原理 激光扫描仪的工作原理是通过发射红外线光束到旋转式镜头的中心,旋转检测环境周围的激光,一旦接触到物体,光束立刻被反射回扫描仪,由记录器记录并计算出激光发射点与物体的距离,最后再配合扫描的水平和垂直方向角,以获得每个点的X、Y、Z坐标。设测点到目标点的观测距离为S,精密时钟编码器同步测量获得每个激光脉冲的水平方向扫描角度观测值α和垂直方向扫描角度观测值θ。一般采用内部坐标系统,X轴在水平扫描面内,Y轴在垂直扫描面内与X轴垂直,Z轴与横向扫描面垂直。扫描过程中,在每个站点上都可以获取大量的点云测量数据,且每个点云的位置信息在扫描坐标中均以极坐标(α,ζ,d)的形式来存储。如果是用传统测量手段获取了控制点的大地坐标,则可以将将点云数据的扫描数据转换为大地坐标,然后应用到测绘领域的各项工程建设中。 2.激光扫描仪分类 现阶段扫描仪在扫描距离、扫描精度、点间距和数量、光斑点的大小等指标有所不同。按照系统运行平台,机载型激光扫描系统可以在短时间内采集大范围内详细的三维点云数据和影像信息。具有测量范围广、速度快的特点,但其测量精度相对较低,且造价昂贵。车载激光扫描系统主要用于城市的建设和维护。地面激光扫描系统是一种固定式扫描系统,精度可以达到变形监测精度的要求。现阶段,地面激光扫描系统在如矿区开采沉降、隧道变形等变形监测中已得到越来越广泛的应用[1]。便携式激光扫描系统是一种手持式激光测距系统,主要应用于测量物体的长度、面积、体积等。 二、激光扫描测量系统应用现状 近年来,随着电子信息技术的不断进步,激光扫描测量系统产业化应用方面的研究也在不断深入,其应用领域日益扩大,逐步从科学研究进入到人们的日常生活。 1.工程应用领域 大型土木工程测量:主要是在道路、桥梁、地下坑道等施工工程现场,对施工之前的地形图进行扫描,提高准确的数据支持,建立施工后目标三维图形,对施工进行质量上的把控,并进行相关数据的记录。复杂工业设备测量:工业设备一般管线林立,纵横交错,因此对工业设备进行规划、改造过程中,可以对激光扫描测量系统进行利用,生成高精度3d模型,为数据测量提供依据。地质应用:可以在地质方面的地质调查、编录、环境监测、安全监测以及裂缝研究中提供技术支持。变形监测:相较于常规变形监测技术,激光扫描测量系统可以得到精度均匀、密度高的数据,可以发现许多细节变化,数据中包含任意截取断面,能够对目标的整体稳定性分析。 2.文物保护领域 通过激光扫描测量仪的高精度、无缝隙测量实现对古建筑的高精度模拟存储、古建筑结构探测和古建筑修复性测量等。同时,还能够通过高精度测量对文物进行真伪鉴别,因此激光扫描测量仪是考古技术发展的重要突破。 3.空间信息技术领域 激光扫描技术与全球定位系统(GPS)、惯性导航系统(INS)、电荷耦合(CCD)等技术相结合,在大范围内高精度数字高程模型(DTM)的实时获取、城市三维模型重建、局部区域地理信息数据的获取等方面均表现出强劲的优势,成为测绘科学与技术的一个重要补充。 4.其他领域 激光扫描测量系统还有一些应用,在制造业中,基于激光扫描仪数据的快速原型法为产品模型设计开发提供了另一种思路,与虚拟制造技术(VirtualManufacturing)一起,被称为未来制造业的两大支柱技术。基于激光扫描测量系统重建的三维模型,可直接应用到国防、执行机关及政府机构等社会安全辨认上。在电脑游戏业方面,利用激光扫描仪获取数据构建三维场景。在电影特技制作方面,也有着广泛的应用[2]。激光扫描测量系统的介入促进了相关应用领域的发展,同时应用领域的大量需求也成为促进研究的动力。 三、激光扫描测量系统发展趋势 随着激光扫描测量系统、三维建模算法及技术的研究和计算机硬件环境的不断发展,结合其自身所具备的特点,激光扫描测量系统也将在以下方面取得较大的发展和应用。1)点云数据处理软件的多功能化和公用化,实现海量数据处理及实时数据共享。2)在硬件设备不变的情况下,测量方法和算法上提高精度,多种方法相结合。3)进一步扩大扫描范围,实现全圆球扫描,获得被测景物空间三维虚拟实体显示[3]。4)能够与其他测量设备(如IMU、GPS、全站仪等)进行联合测量,实现实时导航,定位、并扩大测程和提高精度。5)激光扫

脉冲激光器的能量换算

脉冲激光器的发射激光是不连续,一般以高重频脉冲间隔发射。发射能量以功的单位焦耳(J)计,即每次脉冲做功多少焦耳。 连续激光器发射的能量以功率单位瓦特(W)计量,即每秒钟做功多少焦耳,表示单位时间内做功多少。 瓦和xx的关系:1W=1J/秒。 一台脉冲激光器,脉冲发射能量是1焦耳/次,脉冲频率是50Hz,则每秒钟发射激光50次,每秒钟内做功的平均功率为:50X 1焦耳=50焦耳,所以,平均功率就换算为50瓦。 再举例说明峰值功率的计算,一台绿光脉冲激光器,脉冲能量是 0.14mJ/次,每次脉宽20ns,脉冲频率100kHz, 平均功率为: 0.14mJ X 100k=14J/s=14W,即平均功率为14瓦; 峰值功率是每次脉冲能量与脉宽之比,即 峰值功率: 0.14mJ/20ns=7000W=7kW,峰值功率为7千瓦。 要想知道镜片的脉冲激光损伤阈值是否在承受极限内,既要计算脉冲激光的峰值功率,也要计算脉冲激光的平均功率,综合考虑。 如某ZnSe镜片的激光损伤阈值时是500MW/cm2,使用在一台脉冲激光器中,脉冲激光器的脉冲能量是10J/cm2,脉宽10ns,频率50kHz。 首先,计算平均功率:10J/cm2 X 50kHz = 0.5MW/cm2 其次,再计算峰值功率: 1/ 3

从脉冲激光器的平均功率看,该镜片是能承受不被损伤的,但从脉冲激光器的峰值功率看,是大于该镜片的激光损伤阈值的。所以,综合判断,该ZnSe 镜片不宜用于此脉冲激光器。 如果有条件,对脉冲激光器镜片,应当分别测试平均功率和峰值功率的激光损伤阈值。 Ave. Power : 平均功率 Pulse energy : 脉冲能量 Pulse Width: 脉宽 Peak Power: 峰值功率 Rep. Rate : 脉冲频率 ps: xx,10-12 S ns: xx,10-9S M: 兆,106 J: 2/ 3

XR01 360度二维激光扫描雷达测距系统产品介绍

一、简介 新软汇通XR01 360度二维激光扫描雷达测距系统:是一款低成本二维激光雷达解决方案。它可以实现360度6米范围内的激光测距扫描,产生所在空间的平面点云地图信息用于地图测绘、机器人定位导航、物体/环境建模等应用。 在进行360点采样/周的设置下,XR01扫描频率达6hz,并且最高可达10hz的扫描频率。 XR01采用的激光三角测距系统,可以在各类室内环境以及无日光直接照射的室外环境下应用。产品图片: 规格(长*宽*高):170 *150*80 二、说明 供电与动力 XR01自身带有转速检测与自适应系统,雷达的扫描频率会自动随着实际的电机转速做出调整。无需使用者为XR01提供复杂的供电系统,降低了总体成本。并且外部系统可以通过通讯接口获取当

前雷达的实际转速。 ?安全性与适用范围 采用低功率(<5mW)的红外线激光器作为发射源,并采用调制脉冲方式驱动,激光器仅在极短的时间内进行发射动作。因而可以确保对人类及宠物的安全性,可以达到Class I级别的激光器安全标准。调制的激光可以有效避免在测距扫描过程当中的环境光与日光干扰。可以在各类室内环境以及无日光直接照射的室外环境下应用 ?输出数据 在XR01工作时,每次采样的数据将通过通讯接口输出。每个采样点的数据将包括如下的信息。如果需要具体的数据格式和通讯接口的协议,请与新软汇通联系联系。

三、测量性能 *注:三角测距系统距离分辨率将随着实际距离值变化,XR01的理论具体变化情况如下图所示: 四、光学信息

五、工作环境 ?预热与最佳工作时间 由于测距核心在工作中将产生热量,建议在XR01工作(开启扫描模式、扫描电机开始运转)2分钟后使用。此时测距精度将达到最佳水平。 ?环境温度 当环境温度与常温差距过大将影响测距系统的精度,并可能对扫描系统的结构产生损害。请避免在高温(>40摄氏度)以及低温(<-10摄氏度)的条件中使用。 ?环境光照 XR01的理想工作环境为室内,室内环境光照(包含无光照)不会对XR01工作产生影响。但请避免使用强光源(如大功率激光器)直接照射XR01的视觉系统。 如果需要在室外使用,请避免XR01的视觉系统直接面对太阳照射,这将这可能导致视觉系统的感光芯片出现永久性损伤,从而使测距失效。XR01标准版本在室外强烈太阳光反射条件下的测距范围将缩短。

激光测距仪原理

激光测距仪激光测距基本原理 激光测距是光波测距中的一种测距方式,如果光以速度c在空气中传播在A、B两点间往返一次所需时间为t,则A、B两点间距离D可用下列表示。 D=ct/2 式中:D——测站点A、B两点间距离;c——光在大气中传播的速度;t——光往返A、B 一次所需的时间。 由上式可知,要测量A、B距离实际上是要测量光传播的时间t,根据测量时间方法的不同,激光测距仪通常可分为脉冲式和相位式两种测量形式。 相位式激光测距仪 相位式激光测距仪是用无线电波段的频率,对激光束进行幅度调制并测定调制光往返测线一次所产生的相位延迟,再根据调制光的波长,换算此相位延迟所代表的距离。即用间接方法测定出光经往返测线所需的时间。 相位式激光测距仪一般应用在精密测距中。由于其精度高,一般为毫米级,为了有效的反射信号,并使测定的目标限制在与仪器精度相称的某一特定点上,对这种测距仪都配置了被称为合作目标的反射镜。 若调制光角频率为ω,在待测量距离D上往返一次产生的相位延迟为φ,则对应时间t 可表示为: t=φ/ω 将此关系代入(3-6)式距离D可表示为 D=1/2 ct=1/2 c·φ/ω=c/(4πf) (Nπ+Δφ) =c/4f (N+ΔN)=U(N+) 式中:φ——信号往返测线一次产生的总的相位延迟。 ω——调制信号的角频率,ω=2πf。 U——单位长度,数值等于1/4调制波长 N——测线所包含调制半波长个数。 Δφ——信号往返测线一次产生相位延迟不足π部分。 ΔN——测线所包含调制波不足半波长的小数部分。 ΔN=φ/ω

在给定调制和标准大气条件下,频率c/(4πf)是一个常数,此时距离的测量变成了测线所包含半波长个数的测量和不足半波长的小数部分的测量即测N或φ,由于近代精密机械加工技术和无线电测相技术的发展,已使φ的测量达到很高的精度。 为了测得不足π的相角φ,可以通过不同的方法来进行测量,通常应用最多的是延迟测相和数字测相,目前短程激光测距仪均采用数字测相原理来求得φ。 由上所述一般情况下相位式激光测距仪使用连续发射带调制信号的激光束,为了获得测距高精度还需配置合作目标,而目前推出的手持式激光测距仪是脉冲式激光测距仪中又一新型测距仪,它不仅体积小、重量轻,还采用数字测相脉冲展宽细分技术,无需合作目标即可达到毫米级精度,测程已经超过100m,且能快速准确地直接显示距离。是短程精度精密工程测量、房屋建筑面积测量中最新型的长度计量标准器具。

激光测距仪品牌种类

激光测距仪的品牌很多,很多人都在问激光测距仪到底哪个牌子好其实这个问题很难回答,每个牌子有每个牌子的优势和特点,应该是根据自身的需求,选择最适合的品牌和型号。下面将主要介绍一下激光测距仪各品牌及主要型号的各自优缺点。 一.激光测距仪的品牌 室内用的手持式短距离激光测距仪,其实主要就两个品牌,徕卡和博世,这两个品牌其实差不多,选择一款适合自己的型号和适合自己的价格就可以了。 长距离的望远镜测距仪,目前最为知名的品牌也是世界排名前四大品牌是图雅得,博士能,奥尔法和尼康这四个品牌,下面简单介绍一下这4个品牌: 1.图雅得 全球长距离望远镜式激光测距仪第一品牌,已经连续多年蝉联销量第一的宝座。图雅得激光测距仪主要特点是操作简单,测量精准,测距速度超快。 另外图雅得在多功能测距仪上面拥有巨大的优势,在技术上是另外品牌无法抗衡了,在多功能激光测距仪方面拥有多达20项专利技术。 图雅得是目前唯一一个可以生产,测距+测高+测角+水平测距+两点测高+连续测距+连续测高+连续测角+连续测水平距离机型的厂家。如果你需要选择多功能测距仪,那图雅得有可能是您最好的选择。 2.博士能 历史最为悠久的望远镜式激光测距仪品牌,在2006年前一直是全球望远镜式激光测距仪第一品牌,虽然近几年被图雅得所取代,退居第二。但是2012年,博士能在全球发布了其最新的激光测距仪产品:博士能201965和博士能205107,加上其全球单品总销量第一的ELITE 1500(205100),大有在2013年赶超图雅得的趋势。 博士能在2013年前,主要销售其测距仪产品205106销量表现一般,虽然205100的销量突出,但是仅仅依靠一款ELITE 1500的销量,很难维持其品牌总销量第一的位置,以前几年销量一路下滑成为全球第二品牌。 博士能新产品201965采用了最新的ESP技术,大大提高的测距仪的测量距离,测量精度,以及抗干扰能力,在全球销售中取得突出表现。而其优势产品ELITE 1500(205100)依然保持出强劲的销售势头。使得其2013年有能力和图雅得相抗衡。 博士能测距仪一直以做工精美著称,另外博士能测距仪在高尔夫领域拥有非常高的美誉度,其独特的高尔夫功能,成为高尔夫爱好者的首选品牌。

脉冲激光器的能量换算

脉冲激光器的能量换算 脉冲激光器的发射激光是不连续,一般以高重频脉冲间隔发射。发射能量以功的单位焦耳(J)计,即每次脉冲做功多少焦耳。 连续激光器发射的能量以功率单位瓦特(W)计量,即每秒钟做功多少焦耳,表示单位时间内做功多少。 瓦和焦耳的关系:1W=1J/秒。 一台脉冲激光器,脉冲发射能量是1焦耳/次,脉冲频率是50Hz,则每秒钟发射激光50次,每秒钟内做功的平均功率为:50X 1焦耳=50焦耳,所以,平均功率就换算为50瓦。 再举例说明峰值功率的计算,一台绿光脉冲激光器,脉冲能量是0.14mJ/次,每次脉宽20ns, 脉冲频率100kHz, 平均功率为:0.14mJ X 100k=14J/s=14W,即平均功率为14瓦; 峰值功率是每次脉冲能量与脉宽之比,即 峰值功率:0.14mJ/20ns=7000W=7kW, 峰值功率为7千瓦。 要想知道镜片的脉冲激光损伤阈值是否在承受极限内,既要计算脉冲激光的峰值功率,也要计算脉冲激光的平均功率,综合考虑。 如某ZnSe镜片的激光损伤阈值时是500MW/cm2, 使用在一台脉冲激光器中,脉冲激光器的脉冲能量是10J/cm2,脉宽10ns,频率50kHz。 首先,计算平均功率:10J/cm2 X 50kHz =0.5MW/cm2 其次,再计算峰值功率:10J/cm2 / 10ns = 1000MW/cm2 从脉冲激光器的平均功率看,该镜片是能承受不被损伤的,但从脉冲激光器的峰值功率看,是大于该镜片的激光损伤阈值的。所以,综合判断,该ZnSe镜片不宜用于此脉冲激光器。如果有条件,对脉冲激光器镜片,应当分别测试平均功率和峰值功率的激光损伤阈值。 ?Ave. Power :平均功率 ?Pulse energy :脉冲能量 ?Pulse Width:脉宽 ?Peak Power: 峰值功率 ?Rep. Rate :脉冲频率 ?ps:皮秒,10-12 S ?ns:纳秒,10-9S ?M: 兆,106 ?J: 焦耳 ?W: 瓦

相关文档
最新文档