sch和壁厚对照表

sch和壁厚对照表
sch和壁厚对照表

SCH表示壁厚等级;δ表示外径。

SCH5s SCH10s SCH20s SCH20SCH30SCH40s SCH40SCH60SCH80s SCH80SCH100SCH120SCH140SCH160XXS DN外径mm

mm mm mm mm mm mm mm mm mm kg/m mm mm mm kg/m mm mm mm 1017 1.2 1.6 2.0 2.5 2.5 3.2 3.5

1522 1.6 2.0 2.5 3.0 3.0 4.0 4.0 5.0 7.5 2027 1.6 2.0 2.5 3.0 3.0 4.0 4.0 5.5 8.0 2534 1.6 2.8 3.0 3.5 3.5 4.5 4.5 6.5 9.0 (32)42 1.6 2.8 3.0 3.5 3.5 5.0 5.0 6.5 10.0 4048 1.6 2.8 3.0 4.0 4.0 5.0 5.0 7.0 10.0 5060 1.6 2.8 3.5 3.5 4.0 4.0 5.0 5.5 5.5 7.0 8.5 11.0 (65)76 2.0 3.0 3.5 4.5 5.0 5.0 6.0 7.0 7.0 8.0 9.5 14.0 8089 2.0 3.0 4.0 4.5 5.5 5.5 6.5 7.5 7.5 9.0 11.0 15.0 100114 2.0 3.0 4.0 5.0 6.0 6.0 7.0 8.5 8.5 11.0 14.0 17.0 (125)140 2.0 3.5 5.0 5.0 6.5 6.5 8.0 9.5 9.5 13.0 16.0 19.0 150168 2.8 3.5 5.0 5.5 6.5 7.0 7.0 9.5 11.0 11.0 14.0 18.0 22.0 200219 2.8 4.0 6.5 6.5 7.0 8.0 8.0 10.0 13.0 13.0 15.0 18.0 20.0 24.0 23.0

250273 3.5 4.0 6.5 6.5 8.0 9.5 9.5 13.0 15.0 15.0 18.0 22.0 25.0 28.0 25.0 300325 4.0 4.5 6.5 6.5 8.5 9.5 10.0 14.0 17.0 17.0 22.0 25.0 28.0 34.0 26.0 350356 4.0 5.0 8.0 9.5 11.0 15.0 19.0 24.0 28.0 32.0 36.0

400406 4.5 5.0 8.0 9.5 13.0 17.0 22.0 26.0 32.0 36.0 40.0 4504578.0 11.0 14.0 19.0 24.0 30.0 35.0 40.0 45.0 5005089.5 13.0 15.0 20.0 26.0 32.0 38.0 45.0 50.0 5505599.5 13.0 17.0 22.0 28.0 35.0 42.0 48.0 54.0 6006109.5 14.0 18.0 25.0 32.0 38.0 45.0 52.0 60.0

备注:①SCH**s指奥氏不锈钢,壁厚超过SCH80s按碳钢管选用

②带括号者不推荐使用

美标ASTM A182 Gr F22 对应中国

在美标材质中,A182开头的材质都是不锈钢,

GR:等级(GRADE)

F22:锻件,具体是12Cr1MoV 25Cr2MoV 20Cr1Mo1VA

PIPE,SMLS,:pipe seamless(无缝管)

BE,:beveled(坡口)

S-20,:sch20 管件的壁厚

CS:cast steel 铸铁

ASTM:American Society of Testing Materials 美国材料试验协会,

SA106:美标的一个标准

GR.B,:grade b B等级

ASME:ASME是American Society of Mechanical Engineers(美国机械工程师协会)的英文缩写.

ASME-B36.10M:这里的意思--boiler and pressure vessel code(气压标准)

by the way:

B36.10壁厚等级:Sch10、Sch20、Sch30、Sch40、Sch60、Sch80、Sch100、Sch120、Sch140、Sch160十个等级;这里就是指SCH20

公称压力MPa管道壁厚对照表

(2010年)最新公称压力(MPa)管道壁厚对照表 (一)无缝碳钢管壁厚m m

(二)无缝不锈钢管壁厚mm

(三)焊接钢管壁厚mm

内压金属直管的壁厚 根据SH 3059-2001《石油化工管道设计器材选用通则》确定:当S0< Do /6时,直管的计算壁厚为: S0 = P D0/(2[σ]tΦ+2PY) 直管的选用壁厚为: S = S0 + C 式中S0―― 直管的计算壁厚, mm; P――设计压力, MPa; D0――直管外径, mm; [σ]t―― 设计温度下直管材料的许用应力, MPa; Φ――焊缝系数,对无缝钢管,Φ=1; S――包括附加裕量在内的直管壁厚, mm; C―― 直管壁厚的附加裕量, mm;

Y――温度修正系数,按下表选取。 温度修整系数表 钢管壁厚表示方法有管子表号、钢管壁厚尺寸和管子重量三种方法 1)是以管子表号"Sch"表示壁厚。 管子表号是管子设计压力与设计温度下材料许用应力的比值乘1000,并经圆整后的数值。即: Sch=P/[σ]t×1000 ANSI B36.10壁厚等级:Sch10、Sch20、Sch30、Sch40、Sch60、Sch80、Sch100、Sch120、Sch140、Sch160十个等级; ANSI B36.19壁厚等级:Sch5s、Sch10s、Sch40s、S 2)以钢管壁厚尺寸表示中国、ISO、日本部分钢管标准采用 ch80s四个等级; 表示英制管壁厚系列: Sch.20----全称:Schedule 20 Sch.10s--带s的系列为不锈钢专用,碳钢不用。 举个例子: 2" sch.10s 表示2”接管的壁厚为2.9mm,材质为不锈钢; 2" sch.40 表示2”接管的壁厚为4.0mm。 3)是以管子重量表示管壁厚度,它将管子壁厚分为三种:

sch壁厚等级对照表格

承插焊管件(一)Socket Welding Fittings GB/T 14383、SH 3410、HG/T 21634、ASME B16.11、JIS B2316 公称通径Nominal Pipe Size 承插孔深度 Depth of Socket 壁厚 Wall Thickness 中心至承插孔底 Center to Bottom of Socket A C min 90°弯头、三通、四通 90°Elbow、Tee、Cross 45°弯头 45°Elbow DN NPS J min SCH80 3000 SCH160 6000 XXS 9000 SCH80 3000 SCH160 6000 XXS 9000 SCH80 3000 SCH160 6000 XXS 9000 6 8 10 1/8 1/4 3/8 10 10 10 3.2 3.3 4.0 3.5 4.0 4.4 --- --- --- 11 11 14 11 14 16 --- --- --- 8 8 8 8 8 11 --- --- --- 15 20 25 1/2 3/4 1 10 13 13 4.5 5.0 5.6 6.0 7.0 8.0 9.5 10.0 11.5 16 19 22 19 22 27 25 28 32 11 13 14 13 14 18 16 19 21 32 40 50 11/4 11/2 2 13 13 16 6.3 6.4 7.0 8.0 9.0 11.0 12.0 13.0 14.0 27 32 38 32 38 41 35 38 54 18 21 25 21 25 29 22 25 28 65 80 100 21/2 3 4 16 16 19 8.9 10.0 10.0 12.5 13.8 --- --- --- --- 41 57 67 57 64 --- --- --- --- 29 32 41 32 35 --- --- --- --- ·本表列出的为承插焊管件各相同部分尺寸,不同标准规定的接管尺寸及承插孔径d1、流通孔径d2尺寸见承插焊管件的接管外径、承插孔径及流 通孔尺寸表。 ·当产品为异径时,流通孔d2的尺寸用异径公称通径相对的d2尺寸、中心至承插孔底的尺寸A与同径管件相同。 ·The above list shows sizes of the same parts of SW fittings.The sizes of different codes pipes,socket diameter d1 and bore diameter d2 refer to the list of the pipe outside diameter,socket diameter and bore diameter of SW fittings. ·As to the reducing fittings,size of the bore diameter d2 applies to the relevant size d2 of the reducing norminal pipe size,size of center to the bottom of socket A issame to the straight fittings,

公称压力(MPa)管道壁厚对照表66741

(2010年)最新公称压力(MPa)管道壁厚对照表(一)无缝碳钢管壁厚m m

(二)无缝不锈钢管壁厚mm (三)焊接钢管壁厚mm

内压金属直管的壁厚 根据SH 3059-2001《石油化工管道设计器材选用通则》确定:当S0< Do /6时,直管的计算壁厚为: S0 = P D0/(2[σ]tΦ+2PY) 直管的选用壁厚为: S = S0 + C 式中 S0――直管的计算壁厚, mm; P――设计压力, MPa; D0――直管外径, mm; [σ]t――设计温度下直管材料的许用应力, MPa; Φ――焊缝系数,对无缝钢管,Φ=1; S――包括附加裕量在内的直管壁厚, mm; C――直管壁厚的附加裕量, mm; Y――温度修正系数,按下表选取。 温度修整系数表 钢管壁厚表示方法有管子表号、钢管壁厚尺寸和管子重量三种方法1)是以管子表号"Sch"表示壁厚。

管子表号是管子设计压力与设计温度下材料许用应力的比值乘1000,并经圆整后的数值。即: Sch=P/[σ]t×1000 ANSI B36.10壁厚等级:Sch10、Sch20、Sch30、Sch40、Sch60、Sch80、Sch100、Sch120、Sch140、Sch160十个等级; ANSI B36.19壁厚等级:Sch5s、Sch10s、Sch40s、S 2)以钢管壁厚尺寸表示中国、ISO、日本部分钢管标准采用 ch80s四个等级; 表示英制管壁厚系列: Sch.20----全称:Schedule 20 Sch.10s--带s的系列为不锈钢专用,碳钢不用。 举个例子: 2" sch.10s 表示2”接管的壁厚为2.9mm,材质为不锈钢; 2" sch.40 表示2”接管的壁厚为4.0mm。 3)是以管子重量表示管壁厚度,它将管子壁厚分为三种: a.标准重量管,以STD表示 b加厚管,以XS表示 c.特厚管,以XXS表示。 对于DN≤250mm的管子,Sch40相当于STD,DN<200mm的管子,Sch80相当于XS。 钢管壁厚的分级,在不同标准中所表示的方法也各不相同。 ANSI B36.10和JIS标准中的管子表号为;Schl0、20、30、40、60、80、100、120、140、160。 ANSI B36.19中的不锈钢管管子表号为:5S、10S、40S、80S。 管表号(Sch.)并不是壁厚,是壁厚系列。实际的壁厚,同一管径,在不同的管子表 号中其厚度各异。不同管子表号的管壁厚度,在美国和日本是应用计算承受内压薄壁管厚度

钢管Sch S S STD 壁厚及压力对照表

公称直径管外 径 ANSI B36.10 B36.19 mm in mm Sch5s Sch10s Sch10Sch20Sch30Sch40s STD Sch40Sch60Sch80XS Sch80s Sch100Sch120Sch140Sch160XXS 61/810.29- 1.24--- 1.73 1.73 1.73- 2.41 2.41 2.41-----81/413.7- 1.65--- 1.73 1.73 1.73- 3.02 3.02 3.02-----103/817.1- 1.65--- 2.31 2.31 2.31- 3.2 3.2 3.2-----151/22134 1.65 2.11--- 2.77 2.77 2.77- 3.73 3.73 3.73--- 4.787.47 203/426.7 1.65 2.11--- 2.87 2.87 2.87- 3.91 3.91 3.91--- 5.567.82 25133.4 1.65 2.77--- 3.38 3.38 3.38- 4.55 4.55 4.55--- 6.359.09 32 1 1/442.2 1.65 2.77--- 3.56 3.56 3.56- 4.85 4.85 4.85--- 6.359.7 40 1 1/248.3 1.65 2.77--- 3.68 3.68 3.68- 5.08 5.08 5.08---7.1410.16 50260.3 1.65 2.77--- 3.91 3.91 3.91- 5.54 5.54 5.54---8.1411.07 65 2 1/273 2.11 3.05--- 5.16 5.16 5.16-7.017.017.01---9.5214.02 80388.9 2.11 3.05--- 5.49 5.49 5.49-7.627.627.62---11.1215.24 90 3 1/2102 2.11 3.05--- 5.74 5.74 5.74-8.088.088.08-----1004114.3 2.11 3.05--- 6.02 6.02 6.02-8.568.568.56-11.12-13.4917.12 1255141.3 2.77 3.4--- 6.55 6.55 6.55-9.539.539.53-12.7-15.8819.05 1506168.3 2.77 3.4---7.117.117.11-10.9710.9710.97-14.27-18.2621.94 2008219.1 2.77 3.4- 6.357.048.188.188.1810.3112.712.712.715.0918.2620.6223.0122.22 25010273.1 3.4 3.76- 6.357.89.279.279.2712.712.712.715.0918.2621.4425.428.5825.4 30012323.9 3.96 4.57- 6.358.389.529.5210.314.2712.712.717.4821.4425.428.5833.32-35014356.6 3.96 4.78 6.357.929.52*9.529.5211.1315.0912.712.719.0523.8327.7931.7535.71-40016406.4 4.19 4.78 6.357.929.52*9.529.5212.716.6612.712.721.4426.1930.9636.5240.49-45018457 4.19 4.78 6.357.9211.12*9.529.5214.2719.0512.712.723.8229.3634.9239.4745.24-50020508 4.78 5.54 6.357.9212.7*9.529.5215.0920.6212.712.726.1932.5438.144.4550.01-55022559 4.78 5.54 6.357.9212.7*9.529.52-22.2212.712.728.5834.9241.2847.6253.98-60024610 5.54 6.35 6.357.9214.27*9.529.5217.4824.6112.712.730.9638.8946.0252.3759.54-

sch和壁厚对照表 已阅

SCH表示壁厚等级;δ表示外径。 SCH5s SCH10s SCH20s SCH20SCH30SCH40s SCH40SCH60SCH80s SCH80SCH100SCH120SCH140SCH160XXS DN外径mm mm mm mm mm mm mm mm mm mm kg/m mm mm mm kg/m mm mm mm 1017 1.2 1.6 2.0 2.5 2.5 3.2 3.5 1522 1.6 2.0 2.5 3.0 3.0 4.0 4.0 5.0 7.5 2027 1.6 2.0 2.5 3.0 3.0 4.0 4.0 5.5 8.0 2534 1.6 2.8 3.0 3.5 3.5 4.5 4.5 6.5 9.0 (32)42 1.6 2.8 3.0 3.5 3.5 5.0 5.0 6.5 10.0 4048 1.6 2.8 3.0 4.0 4.0 5.0 5.0 7.0 10.0 5060 1.6 2.8 3.5 3.5 4.0 4.0 5.0 5.5 5.5 7.0 8.5 11.0 (65)76 2.0 3.0 3.5 4.5 5.0 5.0 6.0 7.0 7.0 8.0 9.5 14.0 8089 2.0 3.0 4.0 4.5 5.5 5.5 6.5 7.5 7.5 9.0 11.0 15.0 100114 2.0 3.0 4.0 5.0 6.0 6.0 7.0 8.5 8.5 11.0 14.0 17.0 (125)140 2.0 3.5 5.0 5.0 6.5 6.5 8.0 9.5 9.5 13.0 16.0 19.0 150168 2.8 3.5 5.0 5.5 6.5 7.0 7.0 9.5 11.0 11.0 14.0 18.0 22.0 200219 2.8 4.0 6.5 6.5 7.0 8.0 8.0 10.0 13.0 13.0 15.0 18.0 20.0 24.0 23.0

钢管壁厚等级对照表

钢管壁厚等级对照表 公 外径(D) 公称壁厚 称 直 径 DN A 系列 B 系列 Sch Sch Sch LG Sch Sch STD Sch Sch XS Sch Sch Sch Sch Sch 5s 10s 20s 20 30 40 60 80 100 120 140 180 15 21.3 18 1.6 2.1 2.6 - - - 2.77 2.9 - - 3.6 - - - 4.5 20 26.9 25 1.6 2.1 2.6 - - - 2.87 2.9 - - 4 - - - 5.6 25 33.7 32 1.6 2.8 3.2 - - - 3.38 3.2 - - 4.5 - - - 6.3 32 42.4 38 1.6 2.8 3.2 - - - 3.56 3.6 - - 5 - - - 6.3 40 48.3 45 1.6 2.8 3.2 - - - 3.68 3.6 - - 5 - - - 7.1 50 60.3 57 1.6 2.8 3.6 - 3.2 - 3.91 4 - - 5.6 - - - 8.8 65 76.1 76 2 3 3.6 - 4.5 - 5.16 5 - - 7.1 - - - 10 80 88.9 89 2 3 4 - 4.5 - 5.49 5.6 - - 8 - - - 11 90 101.6 - 2 3 4 - 4.5 - 5.74 5.6 - - 8 - - - 12.5 100 114.3 108 2 3 4 - 5 - 6.02 5.9 - - 8.8 - 11 - 14.2 125 13 9.7 133 2.9 3.4 5 - 5 - 6.55 6.3 - - 10 - 12.5 - 16 150 168.3 159 2.9 3.4 5 - 5.6 - 7.11 7.1 - - 11 - 14.2 - 17.5 200 219.1 219 2.9 4 6.3 - 6.3 7.1 8.18 8 10 - 12.5 16 17.5 20 22.2

消防系统各种工作压力镀锌钢管壁厚对照表

消防系统各种工作压力镀锌钢管壁厚对照表 消防系统各种工作压力镀锌钢管壁厚对照表本文由小口径厚壁钢管生产供应商,自动喷水灭火系统各种工作压力镀锌钢管壁厚对照表壁厚工作压力P≤ 1.0MPa工作压力公称直径 1.0MPa≤P≤ 1.6MPa≤P≤ 1.6MPa 2.5MPaDN 2522.5 3.2DN 3222.5 3.5DN 402.2 52.7 53.5DN 502.2 52.7 53.75DN 652.534DN 802.534DN 10033.54DN 12533.54DN

1503.5 44.5注: 表中壁厚单位为毫米,壁厚不超过规定值的±10%工作压力P> 2.5MPa 444.5 4.5 4.5 5.56管道壁厚设计说明应该有,图纸上没有的话,你可以查通用说明,给你个我自己的表格,这个系列应该是国标管。 管壁厚度误差公差你可以查相关标准。 国标规定一般消防用镀锌无缝钢管都是内径65,100,150的钢管,壁厚3MM~ 4.5MM之间规格外径mm壁厚mm最小壁厚mm焊管(6米定尺)镀锌管(6米定尺)米重kg根重kg公称内径英寸DN15 1/2 21.3 2.8 2.45 1.28 7.68 1.357 8.14DN20 3/4 26.9

2.45 1.66 9.96 1.76 10.56DN25 1 33.7 3.2 2.8 2.41 14.46 2.554 15.32DN32 1.25 42.4 3.5 3.06 3.36 20.16 3.56 21.36DN40

48.3 3.5 3.06 3.87 23.22 4.10 24.60DN50 2 60.3 3.8 3.325 5.29 31.74 5.607 33.64DN65 2.5 76.1 4.0 3.5 7.11 42.66

各种材质钢管SCH壁厚对照表

公称直径INCH 壁厚 Kg/m 壁厚 Kg/m 壁厚 Kg/m 壁厚Kg/m 壁厚 Kg/m 壁厚Kg/m 壁厚 Kg/m 壁厚 Kg/m 壁厚 Kg/m 壁厚Kg/m 1/221.3 2.9 1.32 3.6 1.57 4.5 1.863/426.9 2.9 1.724 2.26 5.6 2.94133.7 3.2 2.41 4.5 3.24 6.3 4.2611/442.4 3.6 3.445 4.61 6.3 5.6111/248.3 3.6 3.975 5.347.17.21260.3 3.2 4.514 5.55 5.67.558.811.1821/276.1 4.57.9558.777.112.081016.3388.9 4.59.37 5.611.5815.961121.134114.3513.48 6.316.788.822.891128.0214.235.055139.7516.61 6.320.721031.8912.539.211648.816168.3 5.622.477.128.221142.6714.253.9617.565.088219.1 6.333.067.137.12841.651051.5612.563.681680.1417.5872098.222.2107.7910273 6.341.43852.288.857.3312.580.316101.417.5110.2622.2137.325137.4828169.1712323.9 6.349.348.868.381077.4114.2108.4517.5132.2322.2165.1725184.2728204.3132230.3414355.6 6.354.27868.571085.221193.4816133.9920165.5225203.8128226.232255.3636283.7316406.4 6.362.16878.61097.7512.5121.4217.5167.8322.2210.3328261.2830278.4536328.8340361.4118457 6.370.02888.5811120.9814.2155.0620215.5325266.3330315.8936373.7540411.3345457.220508 6.377.9410122.8112.5152.7416194.1220240.6828331.4332375.6240461.6445513.7950564.7122559 6.385.8710135.3812.5168.4625329.2128366.6436464.340511.9450627.655683.5824 610 6.3 93.79 10 147.96 14.5 208.03 17.5 255.69 25 360.6532 456.11 40 562.25 45 626.98 55 752.75 60 813.78 SCH20SCH30碳 钢.合 金 钢 管 道 壁 厚 对 照 表 SCH120SCH140SCH160外径SCH40SCH60SCH80SCH100SCH10

SCH英寸对照表

SCH英寸对照表(2009/07/29 15:31) sch是美标钢管的壁厚系列 钢管壁厚的分级,在不同标准中所表示的方法也各不相同。但主要有三种表示方法。 1.以管子表号(Sch.)表示壁厚系列 这是1938年美国国家怔准协会ANSIB36.10(焊接和无缝钢管)标准所规定的。 管子表号(Sch.)是设计压力与设计温度下材料的许用应力的比值乘以1000,并经圆 整后的数值。即 Sch .=P/[ó]t×1000(1-2-1) 式中 P—设计压力,MPa; [ó]t—设计温度下材料的许用应力,MPa。 无缝钢管与焊接钢管的管子表号可查资料确定。 ANSI B36.10和JIS标准中的管子表号为;Schl0、20、30、40、60、80、100、120、140、160。 ANSI B36.19中的不锈钢管管子表号为:5S、10S、40S、80S。 管表号(Sch.)并不是壁厚,是壁厚系列。实际的壁厚,同一管径,在不同的管子表 号中其厚度各异。不同管子表号的管壁厚度,在美国和日本是应用计算承受内压薄壁管厚度 的Barlow公式计算并考虑了腐蚀裕量和螺纹深度及壁厚负偏差-12.5%之后确定的,如公式 (1-2-2)和(1-2-3)所示。tB=D0P/2[ó]t(1-2-2) t=[D0/2(1-0.125)×P/[ó]t]+2.54(1-2-3) 式中 tB t——分别表示理论和计算壁厚,mm D0————管外径,mm P——设计压力,MPa [ó]t——在设计温度下材料的许用压力,MPa

计算壁厚径圆整后才是实际的壁厚。 如果已知钢管的管子表号,可根据式(1-2-1)计算出该钢管所能适应的设计压力,即 P=Sch..× [ó]t/1000(1-2-4) 例如,库存Sch40,碳素钢20无缝钢管,当设计温度为350oC时给钢管所能适应设计压力为: P=40×92/1000①=3.68 MPa 中国石化总公司标准SHJ405规定了无缝钢管的壁厚系列并Sch.5S②, Sch.10, Sch.10s,Sch.20,Sch.20s,Sch.30,Sch.40,Sch。40s,Sch.60,Sch.80,Sch.100, Sch.120,Sch.140,Sch。160,如表1-2-9所示。 2.以管子重量表示管壁厚度的壁厚系列 美国MSS和ANSI规定的以管子重量表示壁厚方法,将管子壁厚分为;种: (1)标准重量管以STD表示; (2)加厚管以XS表示; (3)特厚管以XXS表示。

SCH10、SCH40、SCH80系列对应的钢管壁厚

SCH10、SCH40、SCH80系列对应的钢管 sch, ASTM 主要看附件 ASTM管道标准对照表(公制) 钢管的壁厚系列 钢管壁厚的分级,在不同标准中所表示的方法也各不相同。但主要有三种表示方法。1.以管子表号(Sch.)表示壁厚系列 这是1938年美国国家怔准协会ANSIB36.10(焊接和无缝钢管)标准所规定的。 管子表号(Sch.)是设计压力与设计温度下材料的许用应力的比值乘以1000,并经圆 整后的数值。即 Sch .=P/[ó]t×1000(1-2-1) 式中P—设计压力,MPa; [ó]t—设计温度下材料的许用应力,MPa。 无缝钢管与焊接钢管的管子表号可查资料确定。 ANSI B36.10和JIS标准中的管子表号为;Schl0、20、30、40、60、80、100、120、140、160。 ANSI B36.19中的不锈钢管管子表号为:5S、10S、40S、80S。 管表号(Sch.)并不是壁厚,是壁厚系列。实际的壁厚,同一管径,在不同的管子表号中其厚度各异。不同管子表号的管壁厚度,在美国和日本是应用计算承受内压薄壁管厚度 的Barlow公式计算并考虑了腐蚀裕量和螺纹深度及壁厚负偏差-12.5%之后确定的,如公式 (1-2-2)和(1-2-3)所示。tB=D0P/2[ó]t(1-2-2) t=[D0/2(1-0.125)×P/[ó]t]+2.54(1-2-3) 式中tB t——分别表示理论和计算壁厚,mm D0————管外径,mm P——设计压力,MPa [ó]t——在设计温度下材料的许用压力,MPa 计算壁厚经圆整后才是实际的壁厚。 如果已知钢管的管子表号,可根据式(1-2-1)计算出该钢管所能适应的设计压力,即P=Sch..× [ó]t/1000(1-2-4) 例如,库存Sch40,碳素钢20无缝钢管,当设计温度为350oC时给钢管所能适应设计压力为: P=40×92/1000①=3.68 MPa

工业管道sch壁厚等级对照表

工业管道sch壁厚等级对照表

C·SH5s、10s、40s、80s用于不锈钢管件。·SCH5s、10s、40s、80s applies for stainless steel. 公称通径Nominal Pipe Size 外径 Outside Diameter 公称壁厚T Norminal Wall Thickness NPS DN D SCH5s SCH10s SCH10 SCH20 SHC30 SCH40s STD SCH40 SCH60 SCH80s XS SCH80 SCH100 SCH120 SCH104 SCH160 XXS 1/8 1/4 3/8 6 8 10 10.3 13.7 17.1 --- --- --- 1.24 1.65 1.65 --- --- --- --- --- --- --- --- --- 1.73 2.24 2.31 1.73 2.24 2.31 1.73 2.24 2.31 --- --- --- 2.41 3.02 3.20 2.41 3.02 3.20 2.41 3.02 3.20 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 1/2 3/4 1 15 20 25 21.3 26.7 33.4 1.65 1.65 1.65 2.11 2.11 2.77 --- --- --- --- --- --- --- --- --- 2.77 2.87 3.38 2.77 2.87 3.38 2.77 2.87 3.38 --- --- --- 3.73 3.91 4.55 3.73 3.91 4.55 3.73 3.91 4.55 --- --- --- --- --- --- --- --- --- 4.78 5.56 6.35 7.47 7.82 9.09 11/4 11/2 2 32 40 50 42.2 48.3 60.3 1.65 1.65 1.65 2.77 2.77 2.77 --- --- --- --- --- --- --- --- --- 3.56 3.68 3.91 3.56 3.68 3.91 3.56 3.68 3.91 --- --- --- 4.85 5.08 5.54 4.85 5.08 5.54 4.85 5.08 5.54 --- --- --- --- --- --- --- --- --- 6.35 7.14 8.74 9.70 10.15 11.07